FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TCT Mobile Limited/
  3. RAD218

RAD218HSUPA/HSDPA/UMTS dual band / GSM quad bands mobile phone

TCT Mobile Limited
HSUPA/HSDPA/UMTS dual band / GSM quad bands mobile phone - FCC ID RAD218 - TCT Mobile Limited
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Jan 17, 2012
Application Purpose
Original Equipment
Date of Application
Jan 09, 2012
Equipment Note
HSUPA/HSDPA/UMTS dual band / GSM quad bands mobile phone
Frequency Range
826.40000000 - 846.60000000
Company
TCT Mobile Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 English - CJB3211ALAAA Quick Start Guide For more information about how to use the phone, please go to www.alcatelonetouch.com to download complete user manual. Moreover, from the website you can also view FAQ, upgrade your phone's software and more. 918A IP4081_918A_QG_Eng_USA_05_1201010.indd 1IP4081_918A_QG_Eng_USA_05_1201010.indd 12012-1-10 15:08:122012-1-10 15:08:12 23 Your mobile 1 .................. Keys and connectors1.1 Back key Touchscreen LED light Home key Headset connector Micro-USB connector Volume up Volume down Power key Menu key Search key Prolonged exposure to music at full volume on the music player may damage the listener's hearing. Set your phone volume safely. Use only headphones recommended by TCT Mobile Limited and its affiliates. Table of contents 1 Your mobile ...................................................................................... 3 2 Text input ........................................................................................ 15 3 Phone call ........................................................................................ 16 4 Contacts .......................................................................................... 18 5 Messaging......................................................................................... 19 6 Email ................................................................................................. 20 7 Getting connected ........................................................................ 21 8 Locate my location using GPS satellites .................................. 23 9 Data backup .................................................................................... 24 10 Factory data reset ......................................................................... 25 11 Applications .................................................................................... 25 12 Making the most of your phone ................................................ 26 IP4081_918A_QG_Eng_USA_05_1201010.indd 2-3IP4081_918A_QG_Eng_USA_05_1201010.indd 2-32012-1-10 15:08:122012-1-10 15:08:12 45 On Home screen, press to quickly access • Settings menu or Notification panel; to launch quick search; to manage applications; to customize your Home screen by adding applications or changing wallpaper. On other screens, press to view options list.• Short press: Light up the screen Return to the Home screen or back to the central Home screen. Long press: Enter the recently used applications list. Go back to the previous menu or screen. Short press: Lock the screen Turn on Display (when in Standby mode) Long press: When phone is off, power on the phone. When phone is on, enter Phone options (Silent mode, Airplane mode, Power off) Press to adjust the Volume (in call/media playing mode) Open Search bar for searching within an application, the phone or web. Getting started1.2 Set-up1.2.1 Removing or installing the back cover Inserting or removing the SIM card You must insert your SIM card to make phone calls. Please power off your phone and remove battery before inserting or removing the SIM card. Place the SIM card with the chip facing downwards and slide it into its housing. Make sure that it is correctly inserted. To remove the card, press and slide it out. Installing or removing the battery Insert and click the battery into place, then close the phone cover.• Unclip the cover, then remove the battery.• IP4081_918A_QG_Eng_USA_05_1201010.indd 4-5IP4081_918A_QG_Eng_USA_05_1201010.indd 4-52012-1-10 15:08:122012-1-10 15:08:12 67 Installing and removing the microSD card To release the microSD card holder, slide it in the direction of the arrow and lift it. Then insert the microSD card with the golden contact downward. Finally, turn down the microSD holder and slide it in the opposite direction to lock it. Charging the battery Standard charger UK charger Connect the battery charger to your phone and outlet respectively. To reduce power consumption and energy waste, when battery is fully charged, disconnect your charger from the plug; switch off Wi-Fi, GPS, Bluetooth or background- running applications when not in use; reduce the backlight time, etc. Power on your phone1.2.2 Hold down the Power key until the phone powers on. It will take a few seconds before the screen lights up. Set up your phone for the first time The first time you power on the phone, you are prompted to set up your phone in multiple ways: language, input method, mobile data connection, account setup and synchronization, system update, etc. You are required to sign into your Google account to synchronize email, contacts, calendar and other Google applications (1) . Enter your user name and password, then touch • Sign in. If you forget your password, you can go to http://www.google.com/ to retrieve it. If you don’t own a Google Account, you are prompted to create one by touching Create. Read the setup information on the screen• . Mark/Unmark the check box to choose whether you want to take • advantage of Google's location service, then touch Next. Mark/Unmark the check box to choose whether you want to back • up data with your Google account, then touch Next. Touch • Finish setup. This initial set up can be skipped and enabled via Settings\Accounts & sync. In power on screen without SIM card inserted, you can also connect to a Wi-Fi network to sign into your Google account and to use some features. Power off your phone1.2.3 Hold down the Power key from the Home screen until the phone options appear, select Power off. (1) Application availability depends on country and operator. IP4081_918A_QG_Eng_USA_05_1201010.indd 6-7IP4081_918A_QG_Eng_USA_05_1201010.indd 6-72012-1-10 15:08:122012-1-10 15:08:12 89 Home screen1.3 You can bring all the items (applications, shortcuts, folders and widgets) you use most frequently to your home screen for quick access. Press Home key to switch to Home screen. Status bar Status/Notification indicators • Touch and Drag down to • open n…

Text truncated - open the document above for the full version.

Attestation Statements

one touch 918A Bluetooth&WIFI &GPS Antenna RF Antenna BT Antenna Gain -1.11dBi Main Antenna Gain:

Cover Letter(s)

5F, E building, No. 232, Liang Jing Road ZhangJiang High-Tech Park, Pudong Area Shanghai, P.R. China. 201203 TEL: +86(0)21 61460666 FAX: +86(0)21 61460602 Date 2011-12-13 To: Federal Communications Commission, Authorization & Evaluation Division, 7345 Oakland Mills Road Columbia, MD 21046 And American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: TMC (Telecommunication Metrology Center of MIIT) is authorized to act on our behalf, until otherwise notified, for applications to American Telecommunications Certification Body, Inc. (ATCB). We certify that we are not subject to denial of federal benefits, which includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR1.2002 (b) to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you. Regards, Gong Zhizhou Approval Team Leader TCT Mobile Limited

Cover Letter(s)

5F, E building, No. 232, Liang Jing Road ZhangJiang High-Tech Park, Pudong Area Shanghai, P.R. China. 201203 TEL: +86(0)21 61460666 FAX: +86(0)21 61460602 2011-12-10 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: Permanent Confidentiality request for FCC ID: RAD218 To Whom It May Concern, Pursuant to sections 0.457 and 0.459 of CFR 47, the applicant requests permanent confidential treatment of the following information accompanying this application: - Block Diagram - Schematics - Operational Description - BOM list/Tune-Up-Procedure The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. Yours Sincerely, Zhizhou Gong Approval Team Leader TCT Mobile Limited

External Photos

External Photos

ID Label/Location Info

Label

Internal Photos

Internal Photos

RF Exposure Info

No.2011SAR00140 Page 1 of 235 ©Copyright. All rights reserved by TMC Beijing. SAR TEST REPORT No. 2011SAR00140 For TCT Mobile Limited HSUPA/HSDPA/UMTS dual band / GSM quad bands mobile phone GIN A one touch 918 A With Hardware Version: PIO Software Version: SW317_US FCCID: RAD218 Issued Date: 2012-01-12 No. DGA-PL-114/01-02 Note: The test results in this test report relate only to the devices specified in this report. This report shall not be reproduced except in full without the written approval of TMC Beijing. Test Laboratory: TMC Beijing, Telecommunication Metrology Center of MIIT No. 52, Huayuan Bei Road, Haidian District, Beijing, P. R. China 100191. Tel:+86(0)10-62304633-2079, Fax:+86(0)10-62304793 Email:[email protected]. www.emcite.com No.2011SAR00140 Page 2 of 235 TABLE OF CONTENT 1 TEST LABORATORY..................................................................................................................3 1.1 TESTING LOCATION........................................................................................................................................ 3 1.2 TESTING ENVIRONMENT................................................................................................................................. 3 1.3 PROJECT DATA............................................................................................................................................... 3 1.4 SIGNATURE..................................................................................................................................................... 3 2 CLIENT INFORMATION..............................................................................................................4 2.1 APPLICANT INFORMATION.............................................................................................................................. 4 2.2 MANUFACTURER INFORMATION..................................................................................................................... 4 3 EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ................................4 3.1 ABOUT EUT ................................................................................................................................................... 4 3.2 INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST.......................................................................... 4 3.3 INTERNAL IDENTIFICATION OF AE USED DURING THE TEST............................................................................. 5 4 CHARACTERISTICS OF THE TEST ..........................................................................................5 4.1 APPLICABLE LIMIT REGULATIONS.................................................................................................................. 5 4.2 APPLICABLE MEASUREMENT STANDARDS...................................................................................................... 5 5 OPERATIONAL CONDITIONS DURING TEST ..........................................................................6 5.1 SCHEMATIC TEST CONFIGURATION................................................................................................................. 6 5.2 SAR MEASUREMENT SET-UP.......................................................................................................................... 6 5.3 DASY4 E-FIELD PROBE SYSTEM..................................................................................................................... 7 5.4 E-FIELD PROBE CALIBRATION........................................................................................................................ 8 5.5 OTHER TEST EQUIPMENT...............................................................................................................................9 5.6 EQUIVALENT TISSUES..................................................................................................................................... 9 5.7 SYSTEM SPECIFICATIONS.............................................................................................................................. 10 6 CONDUCTED OUTPUT POWER MEASUREMENT................................................................. 11 6.1 SUMMARY.................................................................................................................................................... 11 6.2 CONDUCTED POWER.................................................................................................................................... 11 7 TEST RESULTS ........................................................................................................................13 7.1 DIELECTRIC PERFORMANCE......................................................................................................................... 13 7.2 SYSTEM VALIDATION.................................................................................................................................... 13 7.3 SUMMARY OF MEASUREMENT RESULTS....................................................................................................... 15 7.4 SUMMARY OF MEASUREMENT RESULTS (BLUETOOTH AND WIFI FUNCTION) ............................................... 21 7.5 CONCLUSION................................................................................................................................................ 27 8 MEASUREMENT UNCERTAINTY ............................................................................................27 9 MAIN TEST INSTRUMENTS ....................................................................................................28 ANNEX A MEASUREMENT PROCESS....................................................................................29 ANNEX B TEST LAYOUT .........................................................................................................30 ANNEX C GRAPH RESULTS.............................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

No.2011SAR00140 Page 201 of 235 No.2011SAR00140 Page 202 of 235 No.2011SAR00140 Page 203 of 235 No.2011SAR00140 Page 204 of 235 No.2011SAR00140 Page 205 of 235 No.2011SAR00140 Page 206 of 235 No.2011SAR00140 Page 207 of 235 No.2011SAR00140 Page 208 of 235 No.2011SAR00140 Page 209 of 235 ANNEX F DIPOLE CALIBRATION CERTIFICATE 835 MHz Dipole Calibration Certificate No.2011SAR00140 Page 210 of 235 No.2011SAR00140 Page 211 of 235 No.2011SAR00140 Page 212 of 235 No.2011SAR00140 Page 213 of 235 No.2011SAR00140 Page 214 of 235 No.2011SAR00140 Page 215 of 235 No.2011SAR00140 Page 216 of 235 No.2011SAR00140 Page 217 of 235 No.2011SAR00140 Page 218 of 235 1900 MHz Dipole Calibration Certificate No.2011SAR00140 Page 219 of 235 No.2011SAR00140 Page 220 of 235 No.2011SAR00140 Page 221 of 235 No.2011SAR00140 Page 222 of 235 No.2011SAR00140 Page 223 of 235 No.2011SAR00140 Page 224 of 235 No.2011SAR00140 Page 225 of 235 No.2011SAR00140 Page 226 of 235 No.2011SAR00140 Page 227 of 235 2450 MHz Dipole Calibration Certificate No.2011SAR00140 Page 228 of 235 No.2011SAR00140 Page 229 of 235 No.2011SAR00140 Page 230 of 235 No.2011SAR00140 Page 231 of 235 No.2011SAR00140 Page 232 of 235 No.2011SAR00140 Page 233 of 235 No.2011SAR00140 Page 234 of 235 No.2011SAR00140 Page 235 of 235

RF Exposure Info

Appendix A: SPEAG’s new calibration certifications Appendix B: SPEAG’s Evaluation report

Test Report

No. 2011HAC00038-1 Page 1 of 53 ©Copyright. All rights reserved by TMC Beijing. HAC RF TEST REPORT No. 2011HAC00038-1 For TCT Mobile Limited HSUPA/HSDPA/UMTS dual band / GSM quad bands mobile phone GIN A one touch 918 A With Hardware Version: PIO Software Version: SW317_US FCCID: RAD218 Results Summary: M Category = M4 (for WCDMA 850/1900) M Category = M3 ( for GSM 850/1900) Issued Date: 2012-01-09 No. DGA-PL-114/01-02 Note: The test results in this test report relate only to the devices specified in this report. This report shall not be reproduced except in full without the written approval of TMC Beijing. Test Laboratory: TMC Beijing, Telecommunication Metrology Center of MIIT No. 52, Huayuan Bei Road, Haidian District, Beijing, P. R. China 100191. Tel:+86(0)10-62304633-2079, Fax:+86(0)10-62304793 Email:[email protected]. www.emcite.com No.2011HAC00038-1 Page 2 of 53 TABLE OF CONTENT 1 TEST LABORATORY..................................................................................................................3 1.1 TESTING LOCATION........................................................................................................................................ 3 1.2 TESTING ENVIRONMENT................................................................................................................................. 3 1.3 PROJECT DATA............................................................................................................................................... 3 1.4 SIGNATURE..................................................................................................................................................... 3 2 CLIENT INFORMATION..............................................................................................................4 2.1 APPLICANT INFORMATION.............................................................................................................................. 4 2.2 MANUFACTURER INFORMATION..................................................................................................................... 4 3 EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ................................4 3.1 ABOUT EUT ................................................................................................................................................... 4 3.2 INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST.......................................................................... 4 3.3 INTERNAL IDENTIFICATION OF AE USED DURING THE TEST............................................................................. 4 3.4 AIR INTERFACES / BANDS INDICATING OPERATING MODES............................................................................ 5 4 CONDUCTED OUTPUT POWER MEASUREMENT...................................................................5 4.1 SUMMARY...................................................................................................................................................... 5 4.2 CONDUCTED POWER...................................................................................................................................... 5 5. REFERENCE DOCUMENTS......................................................................................................6 5.1REFERENCE DOCUMENTS FOR TESTING........................................................................................................... 6 6 OPERATIONAL CONDITIONS DURING TEST ..........................................................................6 6.1 HAC MEASUREMENT SET-UP.................................................................................................................. 6 6.2 PROBE SPECIFICATION.................................................................................................................................... 7 6.3 TEST ARCH PHANTOM & PHONE POSITIONER................................................................................................. 8 6.4 ROBOTIC SYSTEM SPECIFICATIONS................................................................................................................. 8 7 EUT ARRANGEMENT ................................................................................................................9 7.1 WD RF EMISSION MEASUREMENTS REFERENCE AND PLANE........................................................................ 9 8 SYSTEM VALIDATION..............................................................................................................10 8.1 VALIDATION PROCEDURE............................................................................................................................. 10 8.2 VALIDATION RESULT.................................................................................................................................... 10 9 PROBE MODULATION FACTOR ............................................................................................. 11 9.1 MODULATION FACTOR TEST PROCEDURE..................................................................................................... 11 9.2 MODULATION FACTOR.................................................................................................................................. 12 10 RF TEST PROCEDUERES .....................................................................................................12 11 HAC RF TEST DATA SUMMARY............................................................................................13 11.1 MEASUREMENT RESULTS (E-FIELD)........................................................................................................... 13 11.2 MEASUREMENT RESULTS (H-FIELD) .......................................................................................................... 13 11.3 TOTAL M-RATING....................................................................................................................................... 14 12 ANSI C 63.19-2007 LIM…

Text truncated - open the document above for the full version.

Test Report

No. 2011HAC00038-2 Page 1 of 44 ©Copyright. All rights reserved by TMC Beijing. HAC T-Coil TEST REPORT No. 2011HAC00038-2 For TCT Mobile Limited HSUPA/HSDPA/UMTS dual band / GSM quad bands mobile phone GIN A one touch 918 A With Hardware Version: PIO Software Version: SW317_US FCCID: RAD218 Results Summary: T Category = T4 Issued Date: 2012-01-09 No. DGA-PL-114/01-02 Note: The test results in this test report relate only to the devices specified in this report. This report shall not be reproduced except in full without the written approval of TMC Beijing. Test Laboratory: TMC Beijing, Telecommunication Metrology Center of MIIT No. 52, Huayuan Bei Road, Haidian District, Beijing, P. R. China 100191. Tel:+86(0)10-62304633-2079, Fax:+86(0)10-62304793 Email:[email protected]. www.emcite.com No.2011HAC00038-2 Page 2 of 44 TABLE OF CONTENT 1 TEST LABORATORY..................................................................................................................3 1.1 TESTING LOCATION........................................................................................................................................ 3 1.2 TESTING ENVIRONMENT................................................................................................................................. 3 1.3 PROJECT DATA............................................................................................................................................... 3 1.4 SIGNATURE..................................................................................................................................................... 3 2 CLIENT INFORMATION..............................................................................................................4 2.1 APPLICANT INFORMATION.............................................................................................................................. 4 2.2 MANUFACTURER INFORMATION..................................................................................................................... 4 3 EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ................................4 3.1 ABOUT EUT ................................................................................................................................................... 4 3.2 INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST.......................................................................... 4 3.3 INTERNAL IDENTIFICATION OF AE USED DURING THE TEST............................................................................. 4 3.4 AIR INTERFACES / BANDS INDICATING OPERATING MODES............................................................................ 5 4 CONDUCTED OUTPUT POWER MEASUREMENT...................................................................5 4.1 SUMMARY...................................................................................................................................................... 5 4.2 CONDUCTED POWER...................................................................................................................................... 5 5. REFERENCE DOCUMENTS......................................................................................................6 5.1REFERENCE DOCUMENTS FOR TESTING........................................................................................................... 6 6 OPERATIONAL CONDITIONS DURING TEST ..........................................................................6 6.1 HAC MEASUREMENT SET-UP.................................................................................................................. 6 6.2 AM1D PROBE................................................................................................................................................. 7 6.3 AMCC ........................................................................................................................................................... 8 6.4 AMMI............................................................................................................................................................ 8 6.5 TEST ARCH PHANTOM & PHONE POSITIONER................................................................................................. 8 6.6 ROBOTIC SYSTEM SPECIFICATIONS................................................................................................................. 9 6.7 T- COIL MEASUREMENT POINTS AND REFERENCE PLANE................................................................................. 9 7 T-COIL TEST PROCEDUERES ................................................................................................ 11 8 T-COIL PERFORMANCE REQUIREMENTS ............................................................................12 8.1 T- COIL COUPLING FIELD INTENSITY.............................................................................................................. 12 8.2 FREQUENCY RESPONSE................................................................................................................................. 12 9 HAC T-COIL TEST DATA SUMMARY ......................................................................................13 9.1 T- COIL COUPLING FIELD INTENSITY............................................................................................................ 13 9.1.1 AXIAL FIELD INTENSITY............................................................................................................................ 13 9.1.2 RADIAL FIELD INTENSITY.......................................................................................................................... 13 9.2 FREQUENCY RESPONSE AT AXIAL MEASUREMENT POINT............................................................................. 14 9.3 SIGNAL QUALITY......................................................................................................................................... 14 9.4 TOTAL M…

Text truncated - open the document above for the full version.

Test Report

No. 2011TAR607 Page1 of 80 TEST REPORT No. 2011TAR607 for TCT Mobile Limited HSUPA/HSDPA/UMTS dual band / GSM quad bands mobile phone Model Name: GIN A Marketing Name:one touch 918 A FCC ID: RAD218 with Hardware Version: PIO Software Version: SW317_US Issued Date: Dec 13, 2011 Note: The test results in this test report relate only to the devices specified in this report. This report shall not be reproduced except in full without the written approval of TMC Beijing. Test Laboratory: DAR accreditation (DIN EN ISO/IEC 17025): No. DGA-PL-114/01-02 FCC 2.948 Listed: No.733176 IC O.A.T.S listed: No.6629A-1 TMC Beijing, Telecommunication Metrology Center of Ministry of Industry and Information Technology 3/F Shou Xiang Technology Building, No.51 Xueyuan Road, Hai Dian District, Beijing, P. R. China,100191. Tel:+86(0)10-62304633-2604, Fax:+86(0)10-62304793, Email:[email protected], web: www.emcite.com No. 2011TAR607 Page2 of 80 CONTENTS 1. TEST LABORATORY ......................................................................................................................... 3 1.1. TESTING LOCATION .................................................................................................................... 3 1.2. TESTING ENVIRONMENT ........................................................................................................... 3 1.3. PROJECT DATA .............................................................................................................................. 3 1.4. SIGNATURE ..................................................................................................................................... 3 2. CLIENT INFORMATION ................................................................................................................... 4 2.1. APPLICANT INFORMATION ....................................................................................................... 4 2.2. MANUFACTURER INFORMATION ............................................................................................ 4 3. EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ............................. 5 3.1. ABOUT EUT ..................................................................................................................................... 5 3.2. INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST .................................... 5 3.3. INTERNAL IDENTIFICATION OF AE USED DURING THE TEST ....................................... 5 3.4. GENERAL DESCRIPTION ..................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Zhizhou Gong
[email protected]+86(0)2151798260Fax: +86(0)2161460600

Technical Contact

Telecommunications Metrology Center of MIITXue Zhen
[email protected]+86-10-62304633

Floor 3, Shouxiang Science Building, No 51, · Beijing · China

Test Firm

TMC-Telecommunication Metrology Center of M.I.I.TChongwen Song
[email protected]0086-10-62303288Fax: 0086-10-62304793

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
422H826.4 MHz - 846.6 MHz343.60 mW4M13F9W0.1 ppm
Confidentiality
Long Term
Grant Notes
Power Output is ERP for Part 22 and EIRP for Part 24. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 1.0 cm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 0.99 W/kg; Body-worn 1.10 W/kg. This device contains GSM/WCDMA functions that are not operational in U.S. Territories. This filing is only applicable for 850 MHz Cell and 1900 MHz PCS operations. This device contains Bluetooth and WLAN transmitters. HAC Rating: M3/T4 - 2007

Other Applications from TCT Mobile Limited

HSUPA/HSDPA/UMTS tribands / GSM quadbands/LTE 6-band mobile phone - FCC ID RAD558 - TCT Mobile Limited
RAD558

HSUPA/HSDPA/UMTS tribands / GSM quadbands/LTE 6-band mobile phone

Nov 15, 2015

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
CDMA 1X BC0/BC1/BC10 mobile phone - FCC ID RAD556 - TCT Mobile Limited
RAD556

CDMA 1X BC0/BC1/BC10 mobile phone

Sep 08, 2015

Equipment Class

PCE - PCS Licensed Transmitter held to ear
GSM Quadband / UMTS Triband mobile phone - FCC ID RAD552 - TCT Mobile Limited
RAD552

GSM Quadband / UMTS Triband mobile phone

Jun 20, 2015

Equipment Class

PCE - PCS Licensed Transmitter held to ear
HSDPA/HSUPA/HSPA+/UMTS quad band /GSM quad band/LTE 4 band mobile phone - FCC ID RAD550 - TCT Mobile Limited
RAD550

HSDPA/HSUPA/HSPA+/UMTS quad band /GSM quad band/LTE 4 band mobile phone

Jun 06, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
WCDMA tri band / GSM quad band Moblie phone with BT, Wi-Fi functionality. - FCC ID RAD549 - TCT Mobile Limited
RAD549

WCDMA tri band / GSM quad band Moblie phone with BT, Wi-Fi functionality.

May 13, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter