Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 User Manual Table of Contents 1. Safety and Use ........................................................................ 2 2. Installation Guide .................................................................... 3 3. Main Interface Overview ........................................................ 4 4. Connect to Internet ................................................................ 5 5. Statistics .................................................................................. 6 6. Communication ...................................................................... 7 7. Settings ................................................................................. 10 8. Browser ................................................................................. 12 9. Warranty ............................................................................... 12 10. FAQs .................................................................................... 13 11.Certification ......................................................................... 15 2 1. Safety and Use We recommend that you read this chapter carefully before using your modem. The manufacturer disclaims any liability for damage, which may result as a consequence of improper use of the modem or of use contrary to the instructions contained herein. Traffic Safety When driving, do not use the modem: When switched on, the modem emits electromagnetic waves that can interfere with the vehicle’s electronic systems such as ABS anti‐lock brakes or airbags. To ensure that there is no problem, please do not place the modem on top of the dashboard or within an airbag deployment area. Check with your car dealer or the car manufacturer to make sure that the dashboard is adequately shielded from modem RF energy. Conditions of Use 1. Switch the modem off before boarding an aircraft. 2. Switch the modem off when you are in health care facilities, except in designated areas. As with many other types of equipment now in regular use, mobile Tele‐modems can interfere with other electrical or electronic devices, or equipment‐using radio frequencies. 3. Switch the modem off when you are near gas or flammable liquids. Strictly obey all signs and instructions posted in a fuel depot, petrol station, chemical plant, or in any potentially explosive atmosphere. 4. When the modem is switched on, it should be kept at least 15 cm from any medical device such as a pacemaker, a hearing aid or insulin pump, etc. 5. Do not let children use the modem without supervision. The modem may contain small parts that could become detached and create a choking hazard. 6. When replacing the cover, please note that the modem may contain substances that could create an allergic reaction. 7. Always handle the modem with care and keep it in a clean and dust‐free place. 8. Do not open, dismantle or attempt to repair the modem yourself. 9. Do not drop, throw or bend the modem. 10. Do not paint the modem. Collection Point: 3 This symbol on the modem means that it must be taken to collection points at the end of their life: Municipal waste disposal centers with specific bins for these items of equipment Collection bins at points of sale. They will then be recycled, preventing substances being disposed of in the environment, so that their components can be reused. In European Union countries: These collection points are accessible free of charge. All products with this symbol must be brought to these collection points. In non European Union jurisdictions: Items of equipment with this symbol are not to be thrown into ordinary bins if your jurisdiction or your region has suitable recycling and collection facilities; instead they are to be taken to collection points for them to be recycled. In the United States, please visit www.recyclewirelessphones.org for more information on recycling wireless products. Protection against theft The modem is identified by an IMEI (modem serial number) shown on the packaging label and in the modem’s dashboard. We recommend that you note the number the first time you use the modem by opening the dashboard “Settings” > “Diagnostics” to get it. Disclaimer There may be certain differences between the user manual description and the modem’s operation, depending on the software release of the modem or specific operator services. 2. Installation Guide 2.1 Installation Guide for Windows Installation procedures may vary based on the operating system installed on your PC. The following instructions are based on the Windows XP OS: Turn on your PC and plug the modem into the USB interface slot to begin software installation. Windows should automatically detect the new device and will prompt you to begin installation. 4 After following the prompts of installation setup, upon completion, a shortcut will be placed on your desktop for quick future access. Note: 1. If installation “auto‐run” does not begin, you will need to locate the “autoRun.exe)” file in the driver path, and Double‐Click on AutoRun.exe to run the installation manually. 2. A Micro‐SD card is an optional accessory. 3. Please do not remove the USIM/SIM card or the Micro‐SD card when the modem is in use. Upon successful installation of the USB modem program, the program will launch automatically. You may also double‐click the short cut icon on the desktop to launch the program. 2.2 Installation Guide for Mac This manual describes the operations of the connect application. This application requires MAC OS X10.4.9 or 10.7 1. To install the modem connect application on MAC OS X. Please double‐click the file My Connection.pkg 2. Click Continue 3. Select the Partition to install the application and click “Continue Installation” 4. When the installation is finished, you need to restart your computer to use the modem. 5. Clicking Application>My Connection to start the connect application. You may reserve this application in the Dock to access it faster. 3. Main Interface Overview Short Cut Icons Fol…
Text truncated - open the document above for the full version.
TCT Mobile Limited To Whom It May Concern: The TCT Mobile Limited, the undersigned, declared that the model One Touch X520Y support Quad-band GSM bands but 900MHz and 1800MHz bands cannot be used in US. And also it support Tri-band UMTS bands, but WCDMA 2100MHz cannot be used in US too. Thank you for your attention to this matter. Yours Sincerely, Zhizhou Gong Project Engineer
Date: Sept 15, 2011 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 To Whom It May Concern: The TCT Mobile Limited. ,the undersigned, hereby authorizes Mr. Wu Xuewen from Shenzhen Morlab Communications Technology Co., Ltd.,, to act on the behalf of the TCT Mobile Limited. solely in matters relating to the application for an FCC equipment authorization for FCC ID # RAD226 including the signing of documents in connection with this Application. Necessary acts carried out by TCT Mobile Limited.on our behalf of the TCT Mobile Limited.in connection with the Application shall have the same effect as acts of the TCT Mobile Limited.. The TCT Mobile Limited.also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Yours Sincerely, Zhizhou Gong Project Manager
Date: Sept 15, 2011 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 Re: TCT Mobile Limited FCC ID: RAD226 FCC Part 22 & 24 Certification Confidentiality Request Gentlemen: This letter is to comply with 47 CFR 0.457& 0.459 pertaining to confidentiality material. TCT Mobile Limited requests that the following documents regarding this submission for FCC ID: RAD226 be kept confidential: Exhibit Type File Name Block Diagram CONF APPENDIX RAD226_Block Diagram.pdf Schematics CONF APPENDIX RAD226_Schematics.pdf Operational Description CONF APPENDIX RAD226_Operational Description.pdf Part list CONF APPENDIX RAD226_BOM.pdf Tune-Up-Procedure CONF APPENDIX RAD226_Tune up procedure.pdf Those documents contain detailed system and equipment description and related information about the product which TCT Mobile Limited considers to be confidential proprietary, a custom design and , otherwise, not releasable to the general public. Since this design is a basis form which future technological products will evolve, TCT Mobile Limited considers this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give competitors an unfair advantage in the market. Yours Sincerely, Zhizhou Gong Project Manager
RAD226 External Photo
Label Label Location
TCT Mobile Limited Date: Sept 15, 2010 Equipment Authorization Division Office of Engineering and Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Ref: FCC ID: RAD226 Dear Sirs: TCT Mobile Limited. requests acceptance of the labeling proposal described below for HSPA+ USB Modem bearing FCC identifier RAD226. The subject HSPA+ USB Modem are compact handheld models as shown in figure 1, authorized under 47CFR Part 22H&24E for GSM and WCDMA mobile services. Figure 1. Because the majority of the HSPA+ USB Modem housing is composed of indicators, rotating USB head, there is extremely limited space available to attach the required label carrying the FCC identifier. TCT Mobile Limited. proposes placing the label carrying the FCC identifier inside product body as shown in figure 2. Figure 2. TCT Mobile Limited The consumer packaging for these models is a "gift box" which does not allow the HSPA+ USB Modem to be seen at time of purchase. In order to meet the requirements of 47CFR Part 2.925 (d), TCT Mobile Limited. will add the FCC identifier "RAD226" to the outside of the consumer "gift box" packaging. Thank you for your attention to this matter. Yours Sincerely, Zhizhou Gong Project Engineer
RAD226 Internal Photo
Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 1/26 Issue: A Date: 2010/10/06 1 COMOSAR E-FIELD PROBE CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 2/26 Issue: A Date: 2010/10/06 2 COMOSAR SEPT ISOTROPIC E-FIELD PROBE CALIBRATION REPORT DATE: 12/02/2009 REFERENCE: SN 37/08 EP80 OBJECT: COMOSAR SEPT ISOTROPIC E-FIELD PROBE MANUFACTURER: SATIMO SERIAL NUMBER: SN 37/08 EP80 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 24/09/20 10 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 3/26 Issue: A Date: 2010/10/06 3 PRODUCT DESCRIPTION Frequency Range 100 MHz - 30 GHz Probe length 330 mm Length of one dipole 4.5 mm Maximum external diameter 8 mm Probe extremity diameter 6.5 mm Distance between dipoles/probe extremity < 2.7 mm Resistance of the three dipole (at the connector) Dipole 1: R1=1.4382 MΩ Dipole 2: R2=1.4894 MΩ Dipole 3: R3=1.4683 MΩ Connector (HIROSE series SR30) 6 wire male (Hirose SR30series) The probe could be checked by measuring the resistance of the three dipoles. CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION Calibration bench CALISAR Multimeter Keithley 2000 Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 4/26 Issue: A Date: 2010/10/06 4 MEASUREMENT PROCEDURE Probe calibration is realized, in compliance with CENELEC EN 50361 and IEEE 1528 std, with CALISAR, Antennessa proprietary calibration system. The calibration is performed with the EN 50361 annexe technique using reference guide at the five frequencies. Where : P fw = Forward Power P bw = Backward Power a and b = Waveguide dimensions = Skin depth Keithley configuration: Rate = Medium; Filter =ON; RDGS=10; FILTER TYPE =MOVING AVERAGE; RANGE AUTO After each calibration, a SAR measurement is performed on a validation dipole and compared with a NPL calibrated probe, to verify it. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 5/26 Issue: A Date: 2010/10/06 5 PROBE UNCERTAINTIES Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 6/26 Issue: A Date: 2010/10/06 6 1. Calibration at 450.00 MHz A. Calibration parameters. Label GSM450 Epsilon 43.33 Sigma 0.84 S/m Temperature 21°C Antenna gain 2.03 dB Antenna S11 -10.50 dB Low limit detection (CW) 0.72 V/m (0.47 mW/kg) Calibration curves ei=f(V) (i=1,2,3) allow to obtain E-field value using the formula: 2 3 2 2 2 1 **EEEE= The following tables represent the calibration curves linearization by curve segment in CW signal. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 7/26 Issue: A Date: 2010/10/06 7 Calibration coefficients for the three dipoles in CW: v1 e1 v2 e2 v3 e3 0.584004 419.557857 -0.696059 435.622023 0.541191 412.830715 0.467833 339.207465 -0.556278 351.381991 0.469757 336.297240 0.376994 276.348283 -0.452232 288.647980 0.378826 274.224190 0.302778 224.954643 -0.359005 232.397390 0.305842 224.365698 0.241038 182.154071 -0.286978 188.889931 0.246562 183.825274 0.192549 148.484090 -0.230386 154.650994 0.195712 148.993075 0.154033 121.674762 -0.185412 127.378480 0.157543 122.783107 0.123397 100.276479 -0.147311 104.193802 0.125866 100.956090 0.099878 83.770361 -0.118637 86.660489 0.101471 84.063863 0.081165 70.553219 -0.095250 72.263937 0.082289 70.694342 0.065166 59.152028 -0.076788 60.795323 0.066427 59.538957 0.051916 49.592416 -0.061280 51.041514 0.053353 50.232492 0.041968 42.297602 -0.048746 43.022565 0.042906 42.675214 0.033724 36.126757 -0.039149 36.748110 0.034686 36.605243 0.021855 26.962568 -0.024798 27.024723 0.022272 27.149463 0.018405 23.975145 -0.020856 24.085809 0.018755 24.141334 0.015467 21.515985 -0.017534 21.515985 0.015767 21.615299 0.013018 19.309065 -0.014750 19.398191 0.013276 19.487731 0.010938 17.408496 -0.012392 17.529166 0.011157 17.569575 0.009022 15.586953 -0.010228 15.658899 0.009215 15.676938 0.007353 13.956010 -0.008328 13.988181 0.007484 14.020428 0.005989 12.466979 -0.006801 12.495719 0.006111 12.567858 0.004890 11.214019 -0.005573 11.265779 0.005003 11.330818 0.004019 10.133541 -0.004570 10.121882 0.004099 10.168601 0.003279 9.094132 -0.003739 9.157170 0.003352 9.125596 0.002660 8.095827 -0.003041 8.293946 0.002769 8.265350 0.002126 7.324219 -0.002453 7.366500 0.002188 7.358024 0.001685 6.565400 -0.001947 6.580536 0.001724 6.542765 0.001300 5.784440 -0.001511 5.718225 0.001334 5.757862 0.001123 5.245191 -0.001307 5.269400 0.001174 5.275471 0.000891 4.701768 -0.001057 4.723470 0.000924 4.728912 0.000704 4.209798 -0.000850 4.226839 0.000736 4.243862 0.000574 3.790376 -0.000689 3.791428 0.000603 3.830551 0.000457 3.396200 -0.000570 3.434303 0.000483 3.421852 0.000365 3.050686 -0.000463 3.078014 0.000389 3.079630 0.000292 2.745766 -0.000369 2.726866 0.000311 2.759206 0.000236 2.486639 -0.000312 2.489933 0.000246 2.460514 0.000…
Text truncated - open the document above for the full version.
Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 1/6 Issue: B Date: 2010/10/05 1 DIPOLE 835 MHZ CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 2/6 Issue: B Date: 2010/10/05 2 DIPOLE 835 MHz CALIBRATION REPORT DATE: 19/02/2009 REFERENCE: SN 36/08 DIPC99 OBJECT: COMOSAR IEEE REFERENCE DIPOLE MANUFACTURER: SATIMO SERIAL NUMBER: SN 36/08 DIPC99 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 2 3/09/2010 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 3/6 Issue: B Date: 2010/10/05 3 PRODUCT DESCRIPTION Dimension: L=161 mm/ h=89.8mm / d=3.6 mm CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION DATE OF CALIBRATION Vector Network Analyzer HP8753D (SN: 5410A08882) 10-05-2010 MEASUREMENT PROCEDURE We placed the dipole under the flat part of SAM phantom fill with 835 MHz head liquid. Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 4/6 Issue: B Date: 2010/10/05 4 Calibration was performed according to IEEE Std P1528-2003 and OET bulletin 65 Supplement C (Ed. 01-01) VSWR at 835 MHz: -24.77 dB. -24,77 -40 -35 -30 -25 -20 -15 -10 -5 0 0,7350,8350,935 Frequency (GHz) S11 (dB) Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 5/6 Issue: B Date: 2010/10/05 5 SAR MEASUREMENT EQUIPEMENT Voltmeter Keithley (2000, SN:1000572) Date of calibration: 01-07-2010 Signal generator Rohde&Schwarz (SML_03, SN:101868) Date of calibration: 15-11-2009 Power amplifier Nuclétudes (ALB216, SN:10800) Date of calibration: 24-10-2009 Power meter Rohde&Schwarz (NRVD, SN:101066) Date of calibration: 04-07-20 10 Probe SATIMO Bretagne (SN:EP37) CF (30.41,29.18,32.33) Date of calibration: 19-06-2010 SAR MEASUREMENT CONDITION Software OpenSAR V3 Phantom SATIMO Bretagne (SN: SN_20_07_SAM42) Liquid SATIMO Bretagne (Last Calibration: 18 09 08) Head Liquid Values: eps’ : 41,20 sigma : 0,872 Distance between the center of the dipole and the liquid (set with a spacer) 15 mm Area scan resolution dx=8mm/dy=8mm Zoom scan resolution dx=8mm/dy=8m/dz=5mm Frequency 835 MHz Input power 30 dBm Expanded uncertainty (K=1) 8.09% SAR MEASUREMENT RESULT 10g 1g SAR measured Liquid : HL Input power : 1W 6,364 W/Kg + 2,64 % 9,805 W/Kg + 3,21 % Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 6/6 Issue: B Date: 2010/10/05 6 SAR MEASUREMENT PLOTS
Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 1/6 Issue: B Date: 2010/10/05 1 DIPOLE 1800 MHZ CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 2/6 Issue: B Date: 2010/10/05 2 DIPOLE 1800 MHz CALIBRATION REPORT DATE: 19/02/2009 REFERENCE: SN 36/08 DIPF101 OBJECT: COMOSAR IEEE REFERENCE DIPOLE MANUFACTURER: SATIMO SERIAL NUMBER: SN 36/08 DIPF101 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 2 3/09/2010 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 3/6 Issue: B Date: 2010/10/05 3 PRODUCT DESCRIPTION Dimension: L=72 mm/ h=41.7 mm / d=3.6 mm CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION DATE OF CALIBRATION Vector Network Analyzer HP8753D (SN: 5410A08882) 10-05-2010 MEASUREMENT PROCEDURE We placed the dipole under the flat part of SAM phantom fill with 1800 MHz head liquid. Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 4/6 Issue: B Date: 2010/10/05 4 Calibration was performed according to IEEE Std P1528-2003 and OET bulletin 65 Supplement C (Ed. 01-01) VSWR at 1800 MHz: -25.09 dB -25,09 -35 -30 -25 -20 -15 -10 -5 0 1,71,81,9 Frequency (GHz) S11 (dB) Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 5/6 Issue: B Date: 2010/10/05 5 SAR MEASUREMENT EQUIPEMENT Voltmeter Keithley (2000, SN:1000572) Date of calibration: 01-07-2010 Signal generator Rohde&Schwarz (SML_03, SN:101868) Date of calibration: 15-11-2009 Power amplifier Nuclétudes (ALB216, SN:10800) Date of calibration: 24-10-2009 Power meter Rohde&Schwarz (NRVD, SN:101066) Date of calibration: 04-07-2010 Probe SATIMO Bretagne (SN:EP37) CF (35.35,34.93,37.42) Date of calibration: 19-06-2010 SAR MEASUREMENT CONDITION Software OpenSAR V3 Phantom SATIMO Bretagne (SN: SN_20_07_SAM42) Liquid SATIMO Bretagne (Last Calibration: 19 09 08) Head Liquid Values: eps’ : 39,80 sigma : 1,45 Distance between the center of the dipole and the liquid (set with a spacer) 10 mm Area scan resolution dx=8mm/dy=8mm Zoom scan resolution dx=8mm/dy=8m/dz=5mm Frequency 1800 MHz Input power 30 dBm Expanded uncertainty (K=1) 8.09% SAR MEASUREMENT RESULT 10g 1g SAR measured Liquid : HL Input power : 1W 20,05 W/Kg + 1,24 % 39,32 W/Kg + 3,20 % Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 6/6 Issue: B Date: 2010/10/05 6 SAR MEASUREMENT PLOTS
SZ11080094S02 Page 2 of 99 DIRECTORY 1. TESTING LABORATORY.......................................................................................................4 1.1. Identification of the Responsible Testing Laboratory.........................................................4 1.2. Identification of the Responsible Testing Location..............................................................4 1.3. Accreditation Certificate........................................................................................................4 1.4. List of Test Equipments..........................................................................................................4 2. TECHNICAL INFORMATION ...............................................................................................5 2.1. Identification of Applicant.....................................................................................................5 2.2. Identification of Manufacturer..............................................................................................5 2.3. Equipment Under Test (EUT)................................................................................................5 2.3.1. Photographs of the EUT..................................................................................................5 2.3.2. Identification of all used EUTs........................................................................................5 2.4. Applied Reference Documents...............................................................................................6 2.5. Device Category and SAR Limits..........................................................................................6 2.6. Test Environment/Conditions................................................................................................7 3. SPECIFIC ABSORPTION RATE (SAR) ................................................................................8 3.1. Introduction.............................................................................................................................8 3.2. SAR Definition.........................................................................................................................8 4. SAR MEASUREMENT SETUP ...............................................................................................9 4.1. The Measurement System......................................................................................................9 4.2. Probe........................................................................................................................................9 4.3. Phantom................................................................................................................................. 11 4.4. Device Holder........................................................................................................................ 11 5. TISSUE SIMULATING LIQUIDS.........................................................................................12 6. UNCERTAINTY ASSESSMENT ...........................................................................................14 6.1. UNCERTAINTY EVALUATION FOR HANDSET SAR TEST......................................14 6.2. UNCERTAINTY FOR SYSTEM PERFORMANCE CHECK........................................15 7. SAR MEASUREMENT EVALUATION ...............................................................................17 7.1. System Setup..........................................................................................................................17 7.2. Validation Results..................................................................................................................17 8. OPERATIONAL CONDITIONS DURING TEST ................................................................18 8.1. Informations on the testing..................................................................................................18 SZ11080094S02 Page 3 of 99 8.2. Body-worn Configurations...................................................................................................18 8.3. Measurement procedure.......................................................................................................19 8.4. Description of interpolation/extrapolation scheme............................................................19 9. 3G MEASUREMENT PROCEDURES..................................................................................21 9.1. Procedures Used To Establish Test Signal..........................................................................21 9.2. SAR Measurement Conditions for WCDMA.....................................................................21 9.3. Output Power Verification...................................................................................................21 9.4. Simple Dongle Procedures....................................................................................................21 9.5. conducted output power.......................................................................................................22 10. TEST RESULTS LIST .............................................................................................................24 ANNEX A PHOTOGRAPHS OF THE EUT ................................................................................26 ANNEX B GRAPH TEST RESULTS ...........................................................................................30 Change History Issue Date Reason for change 1.0 Sep. 14, 2011 First edition SZ11080094S02 Page 4 of 99 1. Testing Laboratory 1.1. Identification of the Responsible Testing Laboratory Company Name: Shenzhen Morlab Communications Technology Co., Ltd. Department: Morlab Laboratory Address: 3/F, Electronic Testing Building, Shahe Road, Nanshan District, Shenzhen, 518055 P. R. China Responsible Test Lab Manager: Mr. Shu Luan Telephone: +86 755 86130268 Facsimile: +86 755 86130218 1.2. Identification of the Res…
Text truncated - open the document above for the full version.
Report No.: SZ11080094W01 Page 2 of 163 TABLE OF CONTENTS 1. GENERAL INFORMATION .................................................................................................... 3 1.1 EUT Description ......................................................................................................................... 3 1.2 Test Standards and Results ........................................................................................................ 5 1.3 Facilities and Accreditations ...................................................................................................... 6 2. 47 CFR PART 2, PART 22H & 24E REQUIREMENTS ........................................................ 7 2.1 Conducted RF Output Power .................................................................................................... 7 2.2 99% Occupied Bandwidth ...................................................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 6 | 24E | 1.85 GHz - 1.91 GHz | 1.66 W | 248KG7W | 0.1 ppm |

HSUPA/HSDPA/UMTS tribands / GSM quadbands/LTE 6-band mobile phone
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
CDMA 1X BC0/BC1/BC10 mobile phone
Equipment Class
PCE - PCS Licensed Transmitter held to ear
GSM Quadband / UMTS Triband mobile phone
Equipment Class
PCE - PCS Licensed Transmitter held to ear
HSDPA/HSUPA/HSPA+/UMTS quad band /GSM quad band/LTE 4 band mobile phone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
WCDMA tri band / GSM quad band Moblie phone with BT, Wi-Fi functionality.
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter