FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TCT Mobile Limited/
  3. RAD326

RAD326GSM dual band mobile phone

TCT Mobile Limited
GSM dual band mobile phone - FCC ID RAD326 - TCT Mobile Limited
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Apr 23, 2013
Application Purpose
Original Equipment
Date of Application
Apr 22, 2013
Equipment Note
GSM dual band mobile phone
Frequency Range
1850.20000000 - 1909.80000000
Company
TCT Mobile Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

IP4545_1030A_QG_Eng_USA_02_130409.indd 1 2013-4-9 18:21:00 ALCATEL 1030A Quick Start Guide For more information about how to use the phone, please go to www.alcatelonetouch.com to download complete user manual (English version only). Also on our website you can 1 Your mobile .............. 1.1 Keys Navigation key Confirm an option (press the middle of the key) Answer/Send a call In idle screen: Access call log (Redial) (press) Switch on/Switch off the telephone (press and hold) End call Return to idle screen Left softkey Right softkey 1.2 Main screen icons (1) Battery charge level. Vibrate alert: your phone vibrates, but does not ring or beep. Headset connected. Call forwarding activated: your calls are forwarded. Alarm or appointments programed. Level of network reception. Voicemail message arrived. 2 Getting started ......... 2.1 Set-up Removing and installing the back cover Removing and installing the battery Charging the battery Connect the battery charger to your phone and outlet respectively. • The charging may take about 20 minutes to start if the battery is flat. • Be careful not to force the plug into the socket. • Make sure the battery is correctly inserted before connecting the charger. • The outlet must be near to the phone and easily accessible 3 Calls .......................... 3.1 Making a call Dial the desired number then press the key to place the call. If you make a mistake, you can delete the incorrect digits by pressing the right softkey. To hang up the call, press the key. Making an emergency call If your phone is covered by the network, dial emergency number and press the key to make an emergency call. This works even without a SIM card and without typing the PIN code. find helpful FAQs (English version only). 1 4 7 2 5 3 6 Access your voicemail (press and hold) In Edit mode: - Press: access the symbols table - Press and hold: enter zero In Edit mode: - Press: change input methods - Press and hold: access the language list In idle screen: - Press: # Missed calls. Radio is on. Roaming. SIM card missing. Music activated. Silence mode: your phone does not ring, beep or vibrate with the exception of the alarm. Inserting and removing the SIM card Place the SIM card with the chip facing downwards and slide it (avoid electric extension cables). • When using your telephone for the first time, charge the battery fully (approximately 3 hours). You are advised to fully charge the battery ( ). • To reduce power consumption and energy waste, when battery is fully charged, disconnect your charger from the plug; switch off Bluetooth when not in use; reduce the backlight time, etc. The charge is complete when the animation stops. 3.2 Calling your voicemail (1) To access your voicemail, hold down the key. 3.3 Receiving a call When you receive an incoming call, press the key to talk and then hang up using the key. 3.4 Available functions during the call During a call, you can use your directory, your calendar, text messages, etc. without hanging up or dropping the call. PROTECT YOUR HEARING To prevent possible hearing damage, do not listen at 1 Left softkey 2 Answer/Send call Call log 6 Vibrate alert (press and hold) 7 Navigation key: - Press and hold: activate/deactivate the vibrate mode In Edit mode: SMS unread. Flight mode. into its housing. Make sure that it is correctly inserted. To remove the card, press it and slide it out. 2.2 Power on your phone Hold down the key until the phone powers on. high volume levels for long periods. Exercise caution when holding your device near your ear while the loudspeaker is in use. 3 Voicemail (press and hold) 4 Right softkey 5 Switch on/Switch off End call Menu/Confirm an option Messages Calendar Profiles Alarm - Press: (space) 2.3 Power off your phone Hold down the key from the main screen. 1 2 3 (1) The icons and illustrations in this guide are provided for information purposes only. 4 (1) 5 6 Contact your network operator to check service availability. 7 4 Contacts ............ 4.1 Consulting your contacts To access the Contacts from the main screen, press the 6 Call log ................ 6.1 Access You can access the function using the following options: 8 FM radio ............. Your phone is equipped with a radio (1) with RDS functionality. You can use the application as a traditional radio with saved 10 Settings .............. From the main menu, select the menu icon and select the function of your choice in order to customize your telephone: 11.4 Voice alarm With this menu, you may create the voice file and set it as the alarm. 11.5 Notes You can create a note in text format by accessing “Tools\ 13 Making the most of your mobile ............. key and select the icon from the menu. • Select from main menu channels or with parallel visual information related to the radio Phone settings, Call settings, Security, Network, Restore Notes” from the main menu. ONE TOUCH Upgrade 4.2 Adding a contact You can add a new contact to phone or SIM card by selecting "Add contact". 5 Messages ........... 5.1 Create message From the main menu select "Messages" to create text message. You can type a message and you can also modify a predefined message in Templates. While writing a message, select "Options" to access all the messaging options. You can save your messages that you send often to Drafts. Specific letters (accent) will increase the size of the SMS, this may cause multiple SMS to be sent to your recipient. • Press the send key from Home screen 6.2 Available options When you press "Options", you can have access to View, Send SMS, Save to Contacts, Edit before call, Add to blacklist, Add to whitelist, Delete etc. 7 Music.................... Access this feature from the main menu by selecting “Music”. You will have full flexibility of managing music on memory card. Make sure your memory card well inserted before activating music. program on the display if you tune to stations that offer Visual Radio service. You can listen to it while running other …

Text truncated - open the document above for the full version.

Cover Letter(s)

5F, C building, No. 232, Liang Jing Road ZhangJiang High-Tech Park, Pudong Area Shanghai, P.R. China. 201203 TEL: +86(0)21 61460666 FAX: +86(0)21 61460602 Date 2013-3-29 To: Federal Communications Commission, Authorization & Evaluation Division, 7345 Oakland Mills Road Columbia, MD 21046 And American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: TMC (Telecommunication Metrology Center of MIIT) is authorized to act on our behalf, until otherwise notified, for applications to American Telecommunications Certification Body, Inc. (ATCB). We certify that we are not subject to denial of federal benefits, which includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR1.2002 (b) to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you. Regards, Gong Zhizhou Approval Team Leader TCT Mobile Limited

Cover Letter(s)

5F, C building, No. 232, Liang Jing Road ZhangJiang High-Tech Park, Pudong Area Shanghai, P.R. China. 201203 TEL: +86(0)21 61460666 FAX: +86(0)21 61460602 2013-03-29 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: Permanent Confidentiality request for FCC ID: RAD326 To Whom It May Concern, Pursuant to sections 0.457 and 0.459 of CFR 47, the applicant requests permanent confidential treatment of the following information accompanying this application: - Block Diagram - Schematics - Operational Description - BOM list/Tune-Up-Procedure The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. Yours Sincerely, Zhizhou Gong Approval Team Leader TCT Mobile Limited

External Photos

EUT photograph

ID Label/Location Info

FCC ID: RAD326 Label

Internal Photos

EUT Interior photograph

RF Exposure Info

No.2013SAR00051 Page 1 of 80 ©Copyright. All rights reserved by TMC Beijing. SAR TEST REPORT No. 2013SAR00051 For TCT Mobile Limited GSM dual band mobile phone Model name: Ginger US Marketing name: ALCATEL 1030A With Hardware Version: PIO Software Version: v52B FCC ID: RAD326 Issued Date: 2013-04-07 Note: The test results in this test report relate only to the devices specified in this report. This report shall not be reproduced except in full without the written approval of TMC Beijing. Test Laboratory: TMC Beijing, Telecommunication Metrology Center of MIIT No. 52, Huayuan Bei Road, Haidian District, Beijing, P. R. China 100191. Tel:+86(0)10-62304633-2079, Fax:+86(0)10-62304633 Email:[email protected]. www.emcite.com No. 2013SAR00051 Page 2 of 80 Revision Version Report Number Revision Date Memo 2013SAR00051 00 2013-04-07 Initial creation of test report No. 2013SAR00051 Page 3 of 80 TABLE OF CONTENT 1 TEST LABORATORY .................................................................................................................... 5 1.1 TESTING LO C AT I O N ........................................................................................................................................ 5 1.2 TESTING ENVIRONMENT ................................................................................................................................. 5 1.3 PROJECT DATA ............................................................................................................................................... 5 1.4 SIGNATURE ..................................................................................................................................................... 5 2 STATEMENT OF COMPLIANCE .................................................................................................. 6 3 CLIENT INFORMATION ................................................................................................................ 7 3.1 APPLICANT INFORMATION .............................................................................................................................. 7 3.2 MANUFACTURER INFORMATION ..................................................................................................................... 7 4 EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ................................. 8 4.1 ABOUT EUT ................................................................................................................................................... 8 4.2 INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST .......................................................................... 8 4.3 INTERNAL IDENTIFICATION OF AE USED DURING THE TEST ............................................................................ 8 5 TEST METHODOLOGY ................................................................................................................ 9 5.1 APPLICABLE LIMIT REGULATIONS .................................................................................................................. 9 5.2 APPLICABLE MEASUREMENT STANDARDS ...................................................................................................... 9 6 SPECIFIC ABSORPTION RATE (SAR) ...................................................................................... 10 6.1 INTRODUCTION ............................................................................................................................................. 10 6.2 SAR DEFINITION .......................................................................................................................................... 10 7 TISSUE SIMULATING LIQUIDS ................................................................................................. 11 7.1 TARGETS FOR TISSUE SIMULATING LIQUID .................................................................................................... 11 7.2 DIELECTRIC PERFORMANCE ......................................................................................................................... 11 8 SYSTEM VERIFICATION ............................................................................................................ 14 8.1 SYSTEM SETUP ............................................................................................................................................. 14 8.2 SYSTEM VERIFICATION ................................................................................................................................. 15 9 MEASUREMENT PROCEDURES .............................................................................................. 16 9.1 TESTS TO BE PERFORMED ............................................................................................................................. 16 9.2 GENERAL MEASUREMENT PROCEDURE ........................................................................................................ 17 9.3 POWER DRIFT ............................................................................................................................................... 18 10 AREA SCAN BASED 1-G SAR ................................................................................................. 19 10.1 REQUIREMENT OF KDB .............................................................................................................................. 19 10.2 FAST SAR ALGORITHMS ............................................................................................................................ 19 11 CONDUCTED OUTPUT POWER .............................................................................................. 20 11.1 MANUFACTURING TOLERANCE ................................................................................................................... 20 11.2 GSM MEASUREMENT RESULT .................................................................................................................... 20 No. 2013SAR00051…

Text truncated - open the document above for the full version.

Test Report

No.2013TAR284 Page1 of 61 TEST REPORT No. 2013TAR284 for TCT Mobile Limited GSM dual band mobile phone Model Name: Ginger US Marketing Name:ALCATEL 1030A FCC ID : RAD326 with Hardware Version: PIO Software Version: v52B Issued Date: 2013-04-03 Note: The test results in this test report relate only to the devices specified in this report. This report shall not be reproduced except in full without the written approval of TMC Beijing. Test Laboratory: DAR accreditation (DIN EN ISO/IEC 17025): No. D-PL-12123-01-01 FCC 2.948 Listed: No.733176 IC O.A.T.S listed: No.6629B TMC Beijing, Telecommunication Metrology Center of Ministry of Industry and Information Technology 3/F Shou Xiang Technology Building, No.51 Xueyuan Road, Hai Dian District, Beijing, P. R. China,100191. Tel:+86(0)10-62304633-2604, Fax:+86(0)10-62304793, Email:[email protected], web: www.emcite.com No.2013TAR284 Page2 of 61 CONTENTS 1. TEST LABORATORY ......................................................................................................................... 3 1.1. TESTING LOCATION .................................................................................................................... 3 1.2. TESTING ENVIRONMENT ........................................................................................................... 3 1.3. PROJECT DATA .............................................................................................................................. 3 1.4. SIGNATURE ..................................................................................................................................... 3 2. CLIENT INFORMATION ................................................................................................................... 4 2.1. APPLICANT INFORMATION ....................................................................................................... 4 2.2. MANUFACTURER INFORMATION ............................................................................................ 4 3. EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ............................. 5 3.1. ABOUT EUT ..................................................................................................................................... 5 3.2. INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST .................................... 5 3.3. INTERNAL IDENTIFICATION OF AE USED DURING THE TEST ....................................... 5 3.4. NORMAL ACCESSORY SETTING ............................................................................................... 6 3.5. GENERAL DESCRIPTION ............................................................................................................ 6 4. REFERENCE DOCUMENTS ............................................................................................................. 7 4.1. REFERENCE DOCUMENTS FOR TESTING ............................................................................. 7 5. LABORATORY ENVIRONMENT ..................................................................................................... 8 6. SUMMARY OF TEST RESULTS ....................................................................................................... 9 7. TEST EQUIPMENTS UTILIZED .................................................................................................... 10 ANNEX A: MEASUREMENT RESULTS ................................................................................................. 11 A.1 OUTPUT POWER ............................................................................................................................ 11 A.2 EMISSION LIMIT ........................................................................................................................... 17 A.3 CONDUCTED EMISSION ............................................................................................................. 23 A.4 FREQUENCY STABILITY ............................................................................................................ 29 A.5 OCCUPIED BANDWIDTH .............................................................................................................. 31 A.6 EMISSION BANDWIDTH ................................................................................................................ 35 A.7 BAND EDGE COMPLIANCE .......................................................................................................... 39 A.8 CONDUCTED SPURIOUS EMISSION............................................................................................ 41 No.2013TAR284 Page3 of 61 1. Test Laboratory 1.1. Testing Location Company Name: TMC Beijing, Telecommunication Metrology Center of MIIT Address: 3/F Shou Xiang Technology Building, No.51 Xueyuan Road, Hai Dian District, Beijing, P. R. China Postal Code: 100191 Telephone: 00861062304633 Fax: 00861062304793 1.2. Testing Environment Normal Temperature: 15-35°C Relative Humidity: 20-75% 1.3. Project data Testing Start Date: 2013-03-21 Testing End Date: 2013-04-03 1.4. Signature Zi Xiaogang (Prepared this test report) Sun Xiangqian (Reviewed this test report) Lu Bingsong Deputy Director of the laboratory (Approved this test report) No.2013TAR284 Page4 of 61 2. Client Information 2.1. Applicant Information Company Name: TCT Mobile Limite Address /Post: 5F, C building, No. 232, Liang Jing Road ZhangJiang High-Tech Park, Pudong Area Shanghai, P.R. China. 201203 City: Shanghai Postal Code: 201203 Country: China Telephone: 0086-21-61460890 Fax: 0086-21-61460602 2.2. Manufacturer Information Company Name: TCT Mobile Limited Address /Post: 5F, C building, No. 232, Liang Jing Road ZhangJiang High-Tech Park, Pudong Area Shanghai, P.R. China. 201203 City: Shanghai Postal Code: 201203 Country: China Telephone: 0086-21-61460890 Fax: 0086-21-61460602 No.2013TAR284 Page5 of 61 3. Equipment Under Test (EUT) and Ancillary Equipment (AE) 3.1. About EUT Description GSM dual band mobile phone Model N…

Text truncated - open the document above for the full version.

Test Setup Photos

EUT Set-up photos 1. Radiated Spurious Emission 2. Conducted Emission(Charging) 3. Conducted Emission(USB) 4. Radiated Emission(Charging) 5. Radiated Emission(USB)

Test Setup Photos

©Copyright. All rights reserved by TMC Beijing. The Photos of SAR test No. 2013SAR00051 For TCT Mobile Limited GSM dual band mobile phone Model name: Ginger US Marketing name: ALCATEL 1030A With Hardware Version: PIO Software Version: v52B FCC ID: RAD326 Issued Date: 2013-04-07 The test results in this test report relate only to the devices specified in this report. This report shall not be reproduced except in full without the written approval of TMC Beijing. Test Laboratory: TMC Beijing, Telecommunication Metrology Center of MIIT No. 52, Huayuan Bei Road, Haidian District, Beijing, P. R. China 100191. Tel:+86(0)10-62304633-2079, Fax:+86(0)10-62304633 Email:[email protected]. www.emcite.com Picture 1: Constituents of the sample Picture 2: Left Hand Touch Cheek Position Picture 3: Left Hand Tilt 15° Position Picture 4: Right Hand Touch Cheek Position Picture 5: Right Hand Tilt 15° Position Test positions for body: The Body SAR is tested at the following 3 test positions all with the distance =10mm between the EUT and the phantom bottom: Picture 6: Toward Phantom - Fold Picture 7: Toward Ground - Fold Picture 8: Toward Ground with Headset - Fold Picture 9: Toward Ground - Unfold

Contact Information

Applicant

Zhizhou Gong
[email protected]+86(0)2151798260Fax: +86(0)2161460600

Technical Contact

TMC Beijing, Telecommunication Metrology Center ofXue Zhen
[email protected]0086-10-62304633

No. 52, Huayuan Bei Road, Haidian District, · Beijing · China

Test Firm

TMC-Telecommunication Metrology Center of M.I.I.TChongwen Song
[email protected]0086-10-62303288Fax: 0086-10-62304793

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz1.8836 W300KGXW0.1 ppm
Confidentiality
Long Term
Grant Notes
Power Output is ERP for Part 22 and EIRP for Part 24. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 1.0 cm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for head and body-worn accessory conditions are 1.28 W/kg and 0.86 W/kg, respectively.

Other Applications from TCT Mobile Limited

HSUPA/HSDPA/UMTS tribands / GSM quadbands/LTE 6-band mobile phone - FCC ID RAD558 - TCT Mobile Limited
RAD558

HSUPA/HSDPA/UMTS tribands / GSM quadbands/LTE 6-band mobile phone

Nov 15, 2015

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
CDMA 1X BC0/BC1/BC10 mobile phone - FCC ID RAD556 - TCT Mobile Limited
RAD556

CDMA 1X BC0/BC1/BC10 mobile phone

Sep 08, 2015

Equipment Class

PCE - PCS Licensed Transmitter held to ear
GSM Quadband / UMTS Triband mobile phone - FCC ID RAD552 - TCT Mobile Limited
RAD552

GSM Quadband / UMTS Triband mobile phone

Jun 20, 2015

Equipment Class

PCE - PCS Licensed Transmitter held to ear
HSDPA/HSUPA/HSPA+/UMTS quad band /GSM quad band/LTE 4 band mobile phone - FCC ID RAD550 - TCT Mobile Limited
RAD550

HSDPA/HSUPA/HSPA+/UMTS quad band /GSM quad band/LTE 4 band mobile phone

Jun 06, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
WCDMA tri band / GSM quad band Moblie phone with BT, Wi-Fi functionality. - FCC ID RAD549 - TCT Mobile Limited
RAD549

WCDMA tri band / GSM quad band Moblie phone with BT, Wi-Fi functionality.

May 13, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter