FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Leica Geosystems AG/
  3. RFD-RH18

RFD-RH18RadioHandle RH18

Leica Geosystems AG
RadioHandle RH18 - FCC ID RFD-RH18 - Leica Geosystems AG
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Dec 06, 2022
Application Purpose
Original Equipment
Date of Application
Dec 06, 2022
Equipment Note
RadioHandle RH18
Frequency Range
2402.00000000 - 2480.00000000
Company
Leica Geosystems AG
Country
Switzerland

Documents & Files

Select a file to view

Users Manual

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Leica TS16 User Manual Version 5.0 English Introduction Congratulations on the purchase of the Leica TS16. This manual contains important safety directions as well as instructions for setting up the product and operating it. Refer to 9 Safety Directions for fur- ther information. Read carefully through the User Manual before you switch on the product. The content of this document is subject to change without prior notice. Ensure that the product is used in accordance with the latest version of this docu- ment. The content of this document is subject to change without prior notice. Ensure that the product is used in accordance with the latest version of this docu- ment. Updated versions are available for download at the following Internet address: https://myworld.leica-geosystems.com > myProducts. The model and serial number of your product are indicated on the type label. Always refer to this information when contacting your agency or Leica Geo- systems authorised service centre. •Windows® is a registered trademark of Microsoft Corporation in the United States and other countries •Bluetooth® is a registered trademark of Bluetooth SIG, Inc. • SD Logo is a trademark of SD-3C, LLC. All other trademarks are the property of their respective owners. This manual applies to the TS16. NameDescription/Format TS16 Quick GuideProvides an overview of the product together with technical data and safety directions. Intended as a quick reference guide. üü TS16 User ManualAll instructions required in order to operate the product to a basic level are contained in the User Manual. Provides an overview of the product together with technical data and safety directions. - ü Purchase ☞ Product identification Trademarks Validity of this manual Available documentation 2 NameDescription/Format Captivate Technical Reference Manual Overall comprehensive guide to the product and apps. Included are detailed descriptions of special soft- ware/hardware settings and soft- ware/hardware functions intended for technical specialists. - ü Refer to the following resources for documentation/software: • the Leica Captivate USB documentation card • https://myworld.leica-geosystems.com Video tutorials are available on: http://www.leica-geosystems.com/captivate-howto On the last page of this manual, you can find the address of Leica Geosystems headquarters. For a list of regional contacts, please visit http://leica-geosystems.com/contact-us/sales_support. https://myworld.leica-geosystems.com offers a wide range of services, inform- ation and training material. With direct access to myWorld, you are able to access all relevant services whenever it is convenient for you. The availability of services depends on the instrument model. ServiceDescription myProductsAdd all products that you and your company own and explore your world of Leica Geosystems: View detailed information on your products and update your products with the latest software and keep up- to-date with the latest documentation. myServiceView the current service status and full service his- tory of your products in Leica Geosystems service centres. Access detailed information on the services performed and download your latest calibration cer- tificates and service reports. mySupportCreate new support requests for your products that will be answered by your local Leica Geosystems Support Team. View the complete history of your support requests and view detailed information on each request in case you want to refer to previous support requests. myLearningWelcome to the home of Leica Geosystems online learning! There are numerous online courses – avail- able to all customers with products that have valid CCPs (Customer Care Packages). myTrustedServicesAdd your subscriptions and manage users for Leica Geosystems Trusted Services, the secure software services, that assist you to optimise your workflow and increase your efficiency. Leica Geosystems address book 3 ServiceDescription mySmartNetExclusive to GS systems, HxGN SmartNet Global is a family of trustworthy correction services that are easily accessible, and they automatically enable the best possible accuracy everywhere. HxGN SmarNet Global family consists of three services: HxGN Smart- Net Pro, HxGN SmartNet+ and HxGN SmartNet PPP. myDownloadsDownloads of software, manuals, tools, training material and news for Leica Geosystems products. 4 Table of Contents PART 1 TS16 1Safety Directions9 1.1General Introduction9 1.2Definition of Use10 1.3Limits of Use10 1.4Responsibilities11 1.5Hazards of Use11 1.6Laser Classification15 1.6.1General15 1.6.2Distancer, Measurements with Reflectors15 1.6.3Distancer, Measurements without Reflectors16 1.6.4Red Laser Pointer18 1.6.5Automatic Target Aiming (ATRplus)19 1.6.6PowerSearch (PS)20 1.6.7Electronic Guide Light (EGL)21 1.6.8Laser Plummet21 1.6.9AutoHeight Laser Plummet22 1.6.10Laser Guide23 1.7Electromagnetic Compatibility (EMC)25 2Description of the System27 2.1System Components27 2.2System Concept30 2.2.1Software Concept30 2.2.2Power Concept31 2.2.3Data Storage Concept31 2.3Container Contents32 2.4Instrument Components36 3User Interface39 3.1Keyboard39 3.2Operating Principles40 4Operation42 4.1Setting Up the TS Instrument42 4.2Setting Up SmartStation43 4.3Setting Up SmartPole44 4.4Setting up for Remote Control44 4.4.1Setting up for Remote Control (with the RadioHandle)44 4.4.2Setting up for Remote Control (with the TCPS30)44 4.4.3Fixing the Field Controller to a Holder and Pole45 4.4.4Fixing the CS35 Tablet to a Holder and Pole47 4.5Connecting to a Personal Computer48 4.6Power Functions51 4.7Batteries52 4.7.1Operating Principles52 4.7.2Battery for the TS Instrument52 4.8Working with the Memory Device53 4.9LED Indicators54 4.10Guidelines for Correct Results57 5Check & Adjust59 5.1Overview59 5.2Preparation60 Table of Contents5 5.3Combined Adjustment (l, t, i, c and ATRplus)61 5.4Tilting Axis Adjustment (a)63 5.5Adjusting the Circular Level of the Instrument and Tribrach65 5.6Adjust…

Text truncated - open the document above for the full version.

Users Manual

4.2Setting Up SmartStation 008640_001 008641_002 1.Place the GAD110 adapter for the GS15/GS16 antenna onto the instrument by simultaneously pressing and holding-in the four push buttons. ☞ Ensure that the interface connection on the underside of the adapter is on the same side as the Communication side cover. 2.Place the GS15/GS16 antenna onto the adapter by simultaneously pressing and holding-in the two press clips. SmartStation setup step-by-step Operation43 4.3Setting Up SmartPole 008642_003 a c d b f g e h i a GS16 antenna b 360° prism c Field controller on GHT66 holder (Alternative, not illustrated: tablet on GHT78 holder) d GHT63 clamp e GLS31 pole with snap-lock positions f RH17/RH18 RadioHandle g Instrument h Communication side cover, integrated i Tripod 4.4Setting up for Remote Control 4.4.1Setting up for Remote Control (with the RadioHandle) 008643_001 a b c d e f g h a 360° prism b Prism pole c Field controller on GHT66 holder (Alternative, not illustrated: tablet on GHT78 holder) d GHT63 clamp e RH17/RH18 RadioHandle f Instrument g Communication side cover h Tripod 4.4.2Setting up for Remote Control (with the TCPS30) 008644_001 a b c d e f g h i a 360° prism b Prism pole c Field controller on GHT66 holder (Alternative, not illustrated: tablet on GHT78 holder) d GHT63 clamp e Instrument f Tripod g TCPS30 h External battery GEB373 i Y-cable 1.The GHT43 tripod adapter is used to mount the TCPS30 to all Leica standard tripods, and to optimise the radio transmission perform- ance. Attach the TCPS30 to the adapter and then attach the adapter to the tripod leg. SmartPole setup using GS16 Setup for remote control with RadioHandle Setup for remote control with TCPS30 Mounting base radio to tripod step-by- step 44Operation 2.Adjust the angle of TCPS30 until it is vertical. 3.Adjust the location of the adapter on the tripod leg so that there are no metallic objects in the horizontal plane around the antenna. ☞ Metallic objects near the antenna disturb radio transmis- sions. 4. ☞ To achieve the best performance from the TCPS30, mount it in a vertical position on the tripod leg, approximately 30cm from the top. ~ 30 cm 008645_001 ☞ If the adapter is no longer able to retain its angle position, the adjustment bolt at the hinge can be tightened slightly. 4.4.3Fixing the Field Controller to a Holder and Pole The GHT66 holder consists of the following components: 008545_001 a b c f d e g h i GHT63 clamp a Plastic sleeve b Pole clamp c Clamp bolt GHT66 holder d Locking pin e Top clip f Mounting plate g Bottom clip h Tightening screw i Mounting arm ☞ For an aluminium pole, fit the plastic sleeve to the pole clamp. 1.Insert the pole into the clamp hole. 2.Attach the holder to the clamp using the clamp bolt. 3.Adjust the angle and the height of the holder on the pole to a comfortable position. 4.Tighten the clamp with the clamp bolt. Components of the GHT66 holder Fixing the field controller and GHT66 to a pole step-by- step Operation45 5.Before placing the CS field controller onto the mounting plate, ensure that the locking pin is put into the unlocked position. To unlock the locking pin, push the locking pin to the left. 008546_001 6.Hold the CS field controller above the holder and lower the end of the CS field controller into the mounting plate. 7.Apply slight pressure in a downward direction and then lower the top part of the CS field controller until the unit is clicked into the holder. The guides of the mounting plate aid in this action. 7c 7a 7b 008547_001 8.After the CS field controller is placed onto the mounting plate, ensure that the locking pin is put into the locked position. To lock the locking pin, push the locking pin to the right. 008549_001 1.Unlock the locking pin by pushing the locking pin to the left of the mounting plate. 2.Place your palm over the top of the field controller. 3.While in this position, lift the top of the field controller from the holder. 2 3 1 008551_001 Detaching the field controller from a pole step-by-step 46Operation 4.4.4Fixing the CS35 Tablet to a Holder and Pole For fixing the CS35 tablet to a pole you need the following components: 009241_001 a b c f d e h g GHT63 clamp a Plastic sleeve b Pole clamp c Clamp bolt GHT78 holder d Locking lever e Mounting arm f Mounting brackets g Removable inserts h Mounting plate ☞ For an aluminium pole, fit the plastic sleeve to the pole clamp. ☞ If the 833343 hand strap with high corner guards is attached to the tablet, remove the inserts from the mounting brackets before fixing the tablet to the mounting plate. To untighten the screws of the removable inserts, use a 2.5 mm allen key. 1.Insert the pole into the clamp hole. 2.Attach the holder to the clamp using the clamp bolt. 3.Adjust the angle and the height of the holder on the pole to a comfortable position. 4.Tighten the clamp with the clamp bolt. 5. 009244_001 Before placing the CS35 tablet onto the mounting plate, ensure that the locking lever is set to the unlocked position (see illustration). 6. 6b 6a 009246_001 Lower the left side of the tablet and slide it from right to left into the mounting brackets of the holder. Components of GHT63 clamp and GHT78 holder Fixing the CS35 tablet and GHT78 to a pole step-by-step Operation47 7. 7 009248_001 After placing the tablet onto the mounting plate, set the locking lever to the locked position (see illustration). 1. 1 009249_001 Set the locking lever of the GHT78 holder to the unlocked position. 2. 2b 2a 009250_001 Lift the right side of the tablet and slide the tablet to the right and out of the holder. 4.5Connecting to a Personal Computer Windows Mobile Device Center for PC with Windows 7/Windows 8/Windows 10 operating system is the synchronization software for Windows mobile-based pocket PC. WMDC enables a PC and a Windows mobile-based pocket PC to communicate. Leica USB drivers support Windows 7, Windows 8 (8.1) and Windows 10 oper- ating systems. Cables Leica USB drivers support: Name Description GEV223USB da…

Text truncated - open the document above for the full version.

Users Manual

Standard useReversed use CRP10 attached on reflector 23080_001 c a 23081_001 b c d a a GLS51 b MPR122 c GRZ122 d CRP10 with optional CRP13* PoleHeight** ✓ − Tilt Compensation** ✓✓ Refer to the manual of the field soft- ware for information about the set- ting. TargetID** ✓✓ *Feet adapter for the CRP10 tip **Features depending on AP20 variant ☞ For reversed use, the target height must be entered manually. ReflectorTarget height with exchangeable pole tip CRP10CRP10 + CRP13 Unit[m][ft][m][ft] MPR1220.2000.6560.3051.000 GRZ1220.2280.7480.3331.093 Pole handling Setting Up AutoPole109 12Battery for the AP20 ☞ GEB321 batteries must be used in the AP20. GEB211/GEB212 do NOT work with AP20. 23314_001 c b a a Battery holder b Notch of battery holder c Battery GEB321 23315_001 5 4 3 2 1 1.Push the slide fastener of the battery holder in the direction of the arrow with the open-lock symbol. 2.Remove the battery holder from the compartment. Remove the bat- tery from the holder. 3.To insert the battery, attach the battery to the batter holder. Align the battery to fit notch of battery holder. 4.Insert the battery holder into the compartment. 5.Push the slide fastener in the direction of the arrow with the close- lock symbol. Change battery step- by-step 110Battery for the AP20 13Software Update In case a software upload for AP20 is indicated, the correct firmware file has to be selected. The firmware file depends on the AP20 model. ModelSoftware type AP20 H AP20 ID AP20H_ID_Firmware.swu Covers all functions required. AP20 T AP20 AP20_T_Firmware.swu Covers all functions required. ☞ Uploading software can take some time. Ensure that the battery is at least 20% full before you start the upload. Do not remove the battery during the upload process. Software update instructions for all AP20 models: 1.Download the most recent firmware file from https://myworld.leica-geosystems.com to your local PC. 2.Connect AP20 to PC using GEV284 cable. 3.Copy the firmware file onto the AP20 memory device. 4.Disconnect GEV284 cable. 5.Switch AP20 off. 6.Switch AP20 on. 7.The upload starts automatically. During the upload, all three LEDs are flashing consecutively. 8.The update is complete when the Power LED on AP20 is constantly lit. Software upload Software Update111 14Working with the AutoPole 14.1Overview Functionalities are listed according to the individual sales variants. FunctionalityAP20 HAP20 IDAP20 TAP20 PoleHeight ü − üü Tilt Compensation −− üü TargetID − ü − ü ☞ AP20 can only be used in combination with an AP Reflector Pole (CRP4, CRP5, GLS51 and GLS51F). ☞ Establish a Bluetooth connection between the AP20 and the field controller or the total station in order to be operative. Use the con- nection wizard. AutoPole functionalities are supported in 2-person operation and 1-person operation. Use the field software on the total station or field controller to establish a Bluetooth connection. In case of 1-person operation, first establish a connection between field con- troller and total station. Then use the field software on the field controller to establish a connection to the AutoPole. ☞ AP20 T and AP20 require a RH18 attached to total station. 14.2PoleHeight The AP Reflector Pole can be extended to any of the given snap-lock positions in order to overcome obstacles. As soon as a snap-lock position is reached, the attached AP20 receives the detected height from the AP Reflector Pole and transmits it to the field soft- ware of the connected total station or field controller. The transmitted height corresponds to the current length between prism centre and pole tip, which is equivalent to the printed scale on the pole and the height input field within the field software. ☞ Valid height detection is limited to the snap-lock positions. Interme- diate positions are indicated as invalid. Enter the height manually. ☞ Optional pole extensions are not taken into account. ☞ Transmitted heights can be overwritten manually. AutoPole functional- ity Supported connection types Description 112Working with the AutoPole 23363_001 a a Snap-lock positions Action ☞ PoleHeight is only supported with sales variants AP20 H, AP20 T and AP20. ☞ PoleHeight can be used with: • Total station only (2-person operation) • Total station and field controller (1-person operation) 1.Enter a survey app, for example Measure or Stake points. 2.Physically extend or compress the pole to overcome obstacles. ☞ The height input field within Captivate will automatically update to current snap-lock height. ☞ 3D viewer is updated with the current height of the pole. 3.Measure or stake a point. The current height is applied to the coordinate calculation. 14.3Tilt Compensation The AP Reflector Pole can be held in a slanting position over the point to be measured without checking the circular bubble on the pole. When measuring a point, the pole tip must be stable on the point while the pole should be in slight movement. Tilt compensation is indicated by an icon and the Tilt LED and is maintained by natural pole movement, for example while moving to the next point to be measured. Measurements are reliable and accurate even if the pole is not levelled as the tilt values are calculated by an Inertial Measurement Unit. Tilt values contain information about the 3D position of the pole. Diagram PoleHeight step-by- step Description Working with the AutoPole113 23365_001  α Tilt ActionResult ☞ Tilt Compensation is only supported with sales variants AP20 T and AP20 connected via RH18 to an automated total station supporting Target Lock. ☞ Tilt Compensation can be used with total station only (2-person operation) or with an additional field controller connected to a total station (1-person operation). 1.Leica Captivate - Home: Set- tings\TS instrument\Measure & target 2.AP tilt compensation 3.OK 4.Enter a survey app, for example Measure or Stake points. ☞ Tilt Compensation is not suppor- ted within the Setup app. 5.Press Start tilt. Diagram Tilt Compensation step-by-s…

Text truncated - open the document above for the full version.

Internal Photos

Antenna 1 Antenna 2 NINA-B301 OBS421

RF Exposure Info

Test report No. : 4790121321-US-R0-V0 Page : 1 of 9 Issued date : 2022/11/22 FCC ID : RFD-RH18 Underwriters Laboratories Taiwan Co., Ltd. Building B and Building E, No. 372-7, Sec. 4, Zhongxing Rd., Zhudong Township, Hsinchu County, Taiwan Telephone :+886-2-7737-3000 Facsimile (FAX) :+886-3-583-7948 Doc No: 17-EM-F0864 / 5.0 Maximum Permissible Exposure Report Product : Dragon staff Model Name : RH18, CCD18 FCC ID : RFD-RH18 Test Regulation : 47 CFR FCC Part 2.1093 Received Date : 2021/10/27 Test Date : 2021/10/29 Issued Date : 2022/11/22 Applicant : Leica Geosystems AG Heinrich Wild Strasse, 9435 Heerbrugg, Switzerland Issued By : Underwriters Laboratories Taiwan Co., Ltd. Building B and Building E, No. 372-7, Sec. 4, Zhongxing Rd., Zhudong Township, Hsinchu County, Taiwan The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report are responsible of the test sample(s) provided by the client only and are not to be used to indicate applicability to other similar products. Test report No. : 4790121321-US-R0-V0 Page : 2 of 9 Issued date : 2022/11/22 FCC ID : RFD-RH18 Underwriters Laboratories Taiwan Co., Ltd. Building B and Building E, No. 372-7, Sec. 4, Zhongxing Rd., Zhudong Township, Hsinchu County, Taiwan Telephone :+886-2-7737-3000 Facsimile (FAX) :+886-3-583-7948 Doc No: 17-EM-F0864 / 5.0 REVISION HISTORY Original Test Report No.: 4790121321-US-R0-V0 Rev. Test report No. Date Page revised Contents Original 4790121321-US-R0-V0 2022/11/22 - Initial issue Test report No. : 4790121321-US-R0-V0 Page : 3 of 9 Issued date : 2022/11/22 FCC ID : RFD-RH18 Underwriters Laboratories Taiwan Co., Ltd. Building B and Building E, No. 372-7, Sec. 4, Zhongxing Rd., Zhudong Township, Hsinchu County, Taiwan Telephone :+886-2-7737-3000 Facsimile (FAX) :+886-3-583-7948 Doc No: 17-EM-F0864 / 5.0 Table of Contents 1. Attestation of Test Results ......................................................................................... 4 2. Test Methodology and Reference Procedures ......................................................... 5 3. Facilities and Accreditation ...................................................................................... 5 4. Equipment Under Test .............................................................................................. 6 4.1. Description of EUT .............................................................................................. 6 4.2. Description of Available Antennas ...................................................................... 7 5. Requirement ............................................................................................................... 8 6. Radio Frequency Radiation Exposure Evaluation ................................................. 9 Test report No. : 4790121321-US-R0-V0 Page : 4 of 9 Issued date : 2022/11/22 FCC ID : RFD-RH18 Underwriters Laboratories Taiwan Co., Ltd. Building B and Building E, No. 372-7, Sec. 4, Zhongxing Rd., Zhudong Township, Hsinchu County, Taiwan Telephone :+886-2-7737-3000 Facsimile (FAX) :+886-3-583-7948 Doc No: 17-EM-F0864 / 5.0 1. Attestation of Test Results APPLICANT: Leica Geosystems - Part of Hexagon Heinrich Wild Strasse, 9435 Heerbrugg, Switzerland MANUFACTURER: Graf Elektronik GmbH In Steinen 5, 6850 Dornbirn, Austria EUT DESCRIPTION: Dragon staff BRAND: Leica MODEL: RH18, CCD18 SAMPLE STAGE: Mass-Production APPLICABLE STANDARDS STANDARD Test Results 47 CFR FCC PART 2.1093 PASS Underwriters Laboratories Taiwan Co., Ltd. tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by Underwriters Laboratories Taiwan Co., Ltd. based on interpretations and/or observations of test results. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by Underwriters Laboratories Taiwan Co., Ltd. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by Underwriters Laboratories Taiwan Co., Ltd. will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of the Federal Government, or any agency of any government. Prepared By: Approved and Authorized By: Sally Lu Date : 2022/11/22 Kent Liu Date : 2022/11/22 Project Handler Senior Laboratory Engineer Test report No. : 4790121321-US-R0-V0 Page : 5 of 9 Issued date : 2022/11/22 FCC ID : RFD-RH18 Underwriters Laboratories Taiwan Co., Ltd. Building B and Building E, No. 372-7, Sec. 4, Zhongxing Rd., Zhudong Township, Hsinchu County, Taiwan Telephone :+886-2-7737-3000 Facsimile (FAX) :+886-3-583-7948 Doc No: 17-EM-F0864 / 5.0 2. Test Methodology and Reference Procedures The tests documented in this report were performed in accordance with KDB 447498 D01 General RF Exposure Guidance v06. 3. Facilities and Accreditation Test Location Underwriters Laboratories Taiwan Co., Ltd. Address Building B and Building E, No. 372-7, Sec. 4, Zhongxing Rd., Zhudong Township, Hsinchu County, Taiwan Accreditation Certificate Underwriters Laboratories Taiwan Co., Ltd. is accredited by TAF, Laboratory Code 3398. Test report No. : 4790121321-US-R0-V0 Page : 6 of 9 Issued date : 2022/11/22 FCC ID : RFD-RH18 Underwriters Laboratories Taiwan Co., Ltd. Building B and Building E, No. 372-7, Sec. 4, Zhongxing Rd., Zhudong Township, Hsinchu County, Taiwan Telephone :+886-2-7737-3000 Facsimile (FAX) :+886-3-583-7948 Doc No: 17-EM-F0864 / 5.0 4. …

Text truncated - open the document above for the full version.

Test Report

The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned at the time of the testing period only and are not to be used to indicate applicability to other similar products. This report does not imply that the product(s) has met the criteria for certification. FCC PART 15 SUBPART C ISED RSS-247 ISSUE 2 TEST REPORT For Dragon Staff MODEL NUMBER: RH18, CCD18 REPORT NUMBER: UL20211019-000517-WFC FCC ID: RFD-RH18 IC: 3177A-RH18 ISSUE DATE: 7/22/2022 Prepared for Leica Geosystems AG Prepared by UL INTERNATIONAL-SINGAPORE PTE LTD 20 KIAN TECK LANE SINGAPORE 627854 Website: www.ul.com REPORT No.: UL20211019-000517-WFC Page 2 of 49 UL INTERNATIONAL-SINGAPORE PTE LTD FORM NO: 16-EM-F0861 Rev2 This report shall not be reproduced except in full, without the written approval of UL INTERNATIONAL-SINGAPORE PTE LTD Revision History Rev. Issue Date Revisions Revised By 0 7/22/2022 Initial Issue REPORT No.: UL20211019-000517-WFC Page 3 of 49 UL INTERNATIONAL-SINGAPORE PTE LTD FORM NO: 16-EM-F0861 Rev2 This report shall not be reproduced except in full, without the written approval of UL INTERNATIONAL-SINGAPORE PTE LTD Summary of Test Results Clause Test Items FCC Requirements Test Results 1 20dB Bandwidth FCC 15.247 (a) (1) RSS-247 Clause 5 .1 Pass 2 Frequency Separation FCC 15.247 (a)(1) RSS-247 Clause 5 .1 Pass 3 Number of Hopping Frequencies FCC 15.247 (a)(1)(iii) RSS-247 Clause 5 .1 Pass 4 Dwell Time FCC 15.247 (a)(1)(iii) RSS-247 Clause 5 .1 Pass 5 Peak and Average Conducted Power FCC 15.247 (b) (3) RSS-247 Clause 5.4 Pass 6 Conducted Band edge And Spurious emission FCC 15.247 (d) RSS-247 Clause 5.5 Pass 7 Radiated Band edge And Radiated Spurious Emission FCC 15.247 (d) FCC 15.209 FCC 15.205 RSS-247 Clause 5.5 RSS-GEN Clause 8.9 Pass 8 Conducted Emission Test for AC Power Port * FCC 15.207 RSS-GEN Clause 8.8 Not Applicable 9 Antenna Requirement * FCC 15.203 RSS-GEN Clause 8.3 Pass * Conducted Emission Test is not applicable due to battery operated product * The EUT uses a permanently attached antenna, with gain 1dBi and 2.3dBi, in accordance with 47 CFR § 15.203, it shall be considered sufficient to comply with the provisions of this section. REPORT No.: UL20211019-000517-WFC Page 4 of 49 UL INTERNATIONAL-SINGAPORE PTE LTD FORM NO: 16-EM-F0861 Rev2 This report shall not be reproduced except in full, without the written approval of UL INTERNATIONAL-SINGAPORE PTE LTD TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ..................................................................................................5 2. TEST METHODOLOGY ..................................................................................................................6 3. FACILITIES AND ACCREDITATION .................................................................................................6 4. CALIBRATION AND UNCERTAINTY ...............................................................................................7 4.1. MEASURING INSTRUMENT CALIBRATION ..................................................................................... 7 4.2. MEASUREMENT UNCERTAINTY ..................................................................................................... 7 5. EQUIPMENT UNDER TEST ............................................................................................................8 5.1. DESCRIPTION OF EUT .................................................................................................................... 8 5.2. MAXIMUM OUTPUT POWER......................................................................................................... 9 5.3. CHANNEL LIST................................................................................................................................ 9 5.4. TEST CHANNEL CONFIGURATION ................................................................................................ 10 5.5. THE WORSE CASE POWER SETTING PARAMETER ....................................................................... 10 5.6. DESCRIPTION OF AVAILABLE ANTENNAS .................................................................................... 10 5.7. DESCRIPTION OF TEST SETUP ...................................................................................................... 11 6. MEASURING INSTRUMENT AND SOFTWARE USED ..................................................................... 12 7. MEASUREMENT METHODS ....................................................................................................... 12 8. TEST PROCEDURES AND RESULTS .............................................................................................. 13 8.1. NORMAL AND EXTREME CONDITIONS ........................................................................................ 13 8.2. 20 dB BANDWIDTH ..................................................................................................................... 14 8.3. FREQUENCY SEPARATION ........................................................................................................... 19 8.4. NUMBER OF HOPPING FREQUENCIES ......................................................................................... 22 8.5. DWELL TIME ................................................................................................................................ 24 8.6. PEAK AND AVERAGE CONDUCTED OUTPUT POWER .................................................................. 27 8.7. CONDUCTED BANDEDGE AND SPURIOUS EMISSIONS ................................................................ 29 8.8. RADIATED BAND EDGE AND RADIATED SPURIOUS EMISSION ..................................................... 34 8.9. AC POWER LINE CONDUCTED EMISSIONS ..........................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Hannes Juen(Director Global Quality Management)
[email protected]0041717273098Fax: 0041717265098

Test Firm

Underwriters Laboratories Taiwan Co., Ltd.Roy Chen
[email protected]+886-2-7737-3450Fax: +886-3-583-7948

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz10.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Leica Geosystems AG

RFD-BELUGA

Total Station

Oct 01, 2025

Equipment Class

PCB - PCS Licensed Transmitter
CS20 Basic - FCC ID RFD-CSNGP - Leica Geosystems AG
RFD-CSNGP

CS20 Basic

Jun 27, 2024

Equipment Class

JAB - Part 15 Class B Digital Device
RFD-ICG120

iCG120 GNSS Receiver

Jan 25, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
GNSS Reference Server with Wlan - FCC ID RFD-GR50W - Leica Geosystems AG
RFD-GR50W

GNSS Reference Server with Wlan

Jan 11, 2024

Equipment Class

DTS - Digital Transmission System
iCG160 GNSS Receiver - FCC ID RFD-ICG160 - Leica Geosystems AG
RFD-ICG160

iCG160 GNSS Receiver

Mar 26, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter