Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Stollmann E + V GmbH BlueMod+P24 / BlueMod+P25 Hardware reference BlueMod+P24 BlueMod+P25 Hardware reference Author: jw Date of Saving: 03.04.06 Ref: BlueMod+P2_HW_reference_V1_5.doc Revision: 1.5 Page 1 of 35 Stollmann E + V GmbH BlueMod+P24 / BlueMod+P25 Hardware reference Note This device was developed for purposes of communication in an office environment. It is intended solely for our industrial clients who will physically integrate them into their own technical products after having them careful examined for their suitability for the intended purpose by experienced technical personnel. The device was not developed for or intended for use in any specific customer application. The firmware of the device may have to be adapted to the specific intended modalities of use or even replaced by other firmware in order to ensure flawless function in the respective field of applications. Performance data (range, power requirements, etc.) may depend on the operating environment, the field of application, the configuration, and method of control as well as other conditions of use; they may deviate from the technical specifications, the Design Guide specifications or other product documentation. The exact performance characteristics can be determined only by measurements subsequent to integration. Variations in the performance data of mass-produced devices may occur due to individual differences between such devices. Device samples were tested in a reference environment for compliance with the legal requirements applicable to the reference environment. No representation is made regarding the compliance with legal, regulatory, or other requirements in other environments. No representation can be made and no warranty can be assumed regarding the suitability of the device for a specific purpose as defined by our customers. Stollmann reserves the right to make changes to the hardware or firmware or to the specifications without prior notice or to replace the device with a successor model. Of course, any changes to the hardware or firmware of any devices for which we have entered into a supply agreement with our customers will be made only if, and only to the extent that, such changes can reasonably be expected to be acceptable to our customers. No general commitment will be made regarding periods of availability; these must be subject to individual agreement. All agreements are subject to our Terms and Conditions for Deliveries and Payments which you can request from us at any time. Copyright © 2005-2006 Stollmann E+V GmbH Trademarks The Bluetooth Âź word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks by Stollmann E+V GmbH is under license. Other trademarks and trade names are those of their respective owners. Author: jw Date of Saving: 03.04.06 Ref: BlueMod+P2_HW_reference_V1_5.doc Revision: 1.5 Page 2 of 35 Stollmann E + V GmbH BlueMod+P24 / BlueMod+P25 Hardware reference TABLE OF CONTENTS 1 Key Features ......................................................................................................6 2 Applications for the Modules...............................................................................6 3 Description of the Modules.................................................................................6 4 Scope of this Document......................................................................................7 5 Terminal Layout..................................................................................................7 5.1 General Pin Assignment..............................................................................8 5.2 Application specific pin multiplexing............................................................9 5.2.1 SPP configuration.................................................................................9 5.2.2 AudioGateway/Headset â SPP configuration.....................................10 6 Block Diagram...................................................................................................12 7 Terminal Specifics.............................................................................................12 7.1 Power supply.............................................................................................12 7.2 RF-ANTENNA............................................................................................12 7.2.1 Typical Radiation Pattern...................................................................13 7.2.2 BlueMod+P25.....................................................................................13 7.3 Reset.........................................................................................................13 7.4 UART Interface â TXD, RXD, CTS, RTS...................................................13 7.5 USB Interface ............................................................................................14 7.5.1 D+, D-.................................................................................................14 7.5.2 USB Pull-Up Resistor.........................................................................14 7.5.3 USB Self-Powered Mode....................................................................15 7.5.4 USB Bus-Powered Mode....................................................................15 7.6 GPIO Interface...........................................................................................16 7.7 PCM Interface............................................................................................17 8 Test Conditions.................................................................................................17 9 Absolute Maximum Ratings (1) ..........................................................................18 10 Electrical Requirements....................................................................................18 11 I/O Operating Characteristics............................................................................19 1âŠ
Text truncated - open the document above for the full version.
Stollmann E+V GmbH, Mendelssohnstr. 15, D-22761 Hamburg, Germany Page 1 of 1 Tel: ++49-40-890 88-0, Fax: ++49-40-890 88-444, http://www.stollmann.de Dear Gerald, Stollmann Bluetooth Adapter BlueMod+P24/25 FCC ID: RFR-BRSI2 We would like to approve the above product as a limited modular approval specific to FCC Public Notice DA 00-1407, released June 26, 2000, titled Part 15 Unlicensed Modular Transmitter Approval for low power transmitter modules, here a Class 2 Bluetooth Adapter with typ. 0dBm output power. The requirements of the Public Notice DA 00-1407 are met as follows: 1. The module has no own RF shielding. Therefore we apply for a Limited Modular Approval (LMA), constrained to be sold to OEM manufacturers only. This product is designed for being built into measurement devices or machine control devices enabling OEMâs to offer Bluetooth functionality for their products. The interface is working on TTL level and the connector is only made for being soldered on a PCB. Therefore this product cannot be used by end users. There is no user manual, but a Design Guide available, which instructs the OEM how to use this module such that compliance of the end product is always ensured. 2. The BlueMod+P24/25 has buffered data inputs, since the complete Bluetooth protocol stacks is implemented on the BlueMod+P24/25 3. The BlueMod+P24/25 has no own voltage regulator. OEM are instructed on supply voltage range and ripple ratings in the data sheet, DS-1450-2400-102-1.01.pdf. 4. A Hirose unique antenna connector or an internal antenna is used. The Design Guide gives exact instructions on how to implement an internal or external antenna. 5. The EUT was tested in a standalone type configuration as can be seen on pages 62 to 65 of the CETECOM Test Report No. 2-4266-01-03/06. It was mounted on different PCBâs to be identified with â52324 PCB Iâ and â52323 PCB Eâ. Both PCBâs are referenced in the test report. Placed on the base board are only level shifters for translating the serial TTL signals to RS232 level, so that a connection to a PC COM port could be made, and further a connector for a mains plug adaptor for having supply. There was no RF shielding at all necessary to be conform to the FCC part 15 requirements. 6. An exhibit label (including FCC ID) has been included in the Design Guide and the OEM manufacturer has been instructed on how to label the end product. 7. The BlueMod+P24/25 is compliant with all applicable FCC rules. Instructions for maintaining compliance are given in the Design Guide. 8. The BlueMod+P24/25 is compliant with all applicable RF exposure requirements for modular transmitter devices. OEM manufactures are given instructions in the Design Guide for maintaining compliance to RF exposure requirements. Yours faithfully i.A. Jens Jensen Manager of Compliance Engineering
CONFIDENTIALITY REQUEST Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 24.04.2006 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commissionâs Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, Company requests confidentiality for the following products: FCC ID Number Product Title/Model FCC ID: RFR-BRSI2 BlueMod+P24, BlueMod+P25 For the product stated above, we request that the following information be held confidential: 1. Circuit diagrams, BOM, and PCBs submitted as Equipment Authorization Electronic Filing attachment: "schematicsâ. 2. Block diagram submitted as Equipment Authorization Electronic Filing attachment: âblockdiagramâ. 3. Operational description submitted as Equipment Authorization Electronic Filing attachment: âoperational descriptionâ The above exhibits contain Company trade secrets and proprietary information that could be of benefit to our competitors regarding the design of our mobile handset. This material is not customarily available to the general public and we request that it be withheld from public inspection. If you have any questions, please feel free to contact me at the address shown below. Sincerely, i.A. Name: i.A. Jens Jensen Company: Stollmann E+V GmbH Address: Mendelssohnstr. 15d, 22761 Hamburg, Germany Phone: ++49.40.89088.498 Email: [email protected]
CETECOM ICT Services GmbH UntertĂŒrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4266-01-03-A/06 Date: 2006-03-21 Page 62 of 65 5 Photographs of EUT Photo 1: wih external antenna
BlueMod+P25 Label CETECOM ICT Services GmbH UntertĂŒrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4266-01-03-A/06 Date: 2006-03-21 Page 64 of 65 Photo 3: with internal antenna
CETECOM ICT Services GmbH UntertĂŒrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4266-01-03-A/06 Date: 2006-03-21 Page 63 of 65 Photo 2: CETECOM ICT Services GmbH UntertĂŒrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4266-01-03-A/06 Date: 2006-03-21 Page 64 of 65 Photo 3: with internal antenna CETECOM ICT Services GmbH UntertĂŒrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4266-01-03-A/06 Date: 2006-03-21 Page 65 of 65 Photo 4:
CETECOM ICT Services GmbH UntertĂŒrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4266-01-03/06 Date: 2006-03-21 Page 1 of 65 \\ut55\2_PROJEKTE\06\4266_1\2-4266-01-03_06 FCC 15-247.doc Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: 3463 (IC) TCB ID: DE 0001 Accredited by the German Accreditation Council DARâRegistration Number DAT-P-176/94-D1 Independent ETSI compliance test house ETSI Accredited Bluetooth Âź Test Facility (BQTF) Test report no. : 2-4266-01-03/06 Applicant : Stollmann E+V GmbH Type : BlueMod+P24/25 Test Standard : FCC Part 15.247 RSS-210 issue 6 FCC ID : RFR-BRSI2 Certification No. IC : 4957A-BRSI2 CETECOM ICT Services GmbH UntertĂŒrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4266-01-03/06 Date: 2006-03-21 Page 2 of 65 Table of contents 1. ADMINISTRATIVE DATA ...................................................................................................................................... 3 1.1. ADMINISTRATIVE DATA OF THE TEST FACILITY..................................................................................................... 3 1.1.1 Identification of the testing laboratory ......................................................................................................... 3 1.1.2 Organizational items..................................................................................................................................... 3 1.1.3 Applicant Ìs details ........................................................................................................................................ 4 1.2 ADMINISTRATIVE DATA OF MANUFACTURER / MEMBER........................................................................................ 4 1.3 DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT) .......................................................................................... 5 1.3.1 EUT: Type, S/N etc. ...................................................................................................................................... 5 1.3.2 If RF component testing only, describtion of additional used HW/SW ......................................................... 5 1.3.3 Additional EUT information For IC Canada (appendix 2)...........................................................................6 1.3.4 EUT operating modes ................................................................................................................................... 7 1.3.5 Extreme conditions testing values................................................................................................................. 7 2. TESTSTANDARD & SUMMARY LIST OF ALL PERFORMED TEST CASES .............................................. 8 3. RF MEASUREMENT TESTING ............................................................................................................................. 9 3.1 DESCRIPTION OF TEST SET-UP................................................................................................................................9 3.1.1 Radiated measurements ................................................................................................................................ 9 3.1.2 Conducted measurements ............................................................................................................................. 9 3.2 REFERENCED DOCUMENTS................................................................................................................................... 10 3.3 ADDITIONAL COMMENTS..................................................................................................................................... 10 3.4 ANTENNA GAIN................................................................................................................................................... 10 3.5 CARRIER FREQUENCY SEPARATION §15.247(A)(1) .............................................................................................. 11 3.6 NUMBER OF HOPPING CHANNELS §15.247(A)(1).................................................................................................. 12 3.7 TIME OF OCCUPANCY (DWELL TIME) §15.247(A)(1)(III)...................................................................................... 13 3.8 POWER SPECTRAL DENSITY (HYBRID SYSTEM IN INQUIRY MODE/PAGE SCAN) §15.247(E) ................................. 14 3.9 SPECTRUM BANDWIDTH OF A FHSS SYSTEM / 20DB BANDWITH §15.247(A)(1)................................................. 15 3.10 MAXIMUM OUTPUT POWER (CONDUCTED) § 15.247 (B)(1) .................................................................................. 17 3.11 MAX. PEAK OUTPUT POWER (RADIATED) § 15.247 (B)(1) .................................................................................... 19 3.12 BAND-EDGE COMPLIANCE OF CONDUCTED EMISSIONS §15.247 (D) ..................................................................... 20 3.13 BAND-EDGE COMPLIANCE OF RADIATED EMISSIONS §15.205 (EXTERNAL ANTENNA) .......................................... 23 3.14 BAND-EDGE COMPLIANCE OF RADIATED EMISSIONS §15.205 (INTERNAL ANTENNA)........................................... 26 3.15 SPURIOUS EMISSIONS - CONDUCTED (TRANSMITTER) § 15.247 (C)(1) ................................................................ 29 3.16 SPURIOUS EMISSIONS > 30 MHZ- RADIATED (TRANSMITTER) § 15.247 (C)(1) (EXTERNAL ANTENNA) ................ 32 3.17 SPURIOUS EMISSIONS > 30 MHZ- RADIATED (TRANSMITTER) § 15.247 (C)(1) (INTERNAL ANTENNA)................. 39 3.18 SPURIOUS EMISSIONS - RADIATED (RECEIVER) § 15.109 (EXTERNAL ANTENNA) ................................................. 46 3.19 SPURIOUS EMISSIONS - RADIATED (RECEIVER) § 15.109 (INTERNAL ANTENNA)....................âŠ
Text truncated - open the document above for the full version.
CETECOM ICT Services GmbH UntertĂŒrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4266-01-03-A/06 Date: 2006-03-21 Page 56 of 65 4 Photographs of Test Set-up External antenna Photo 1: Radiated Emissions CETECOM ICT Services GmbH UntertĂŒrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4266-01-03-A/06 Date: 2006-03-21 Page 57 of 65 Photo 2: Radiated Emissions CETECOM ICT Services GmbH UntertĂŒrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4266-01-03-A/06 Date: 2006-03-21 Page 58 of 65 Photo 3: Conducted Emissions CETECOM ICT Services GmbH UntertĂŒrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4266-01-03-A/06 Date: 2006-03-21 Page 59 of 65 Internal antenna Photo 1: Radiated Emissions CETECOM ICT Services GmbH UntertĂŒrkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4266-01-03-A/06 Date: 2006-03-21 Page 60 of 65 Photo 2: Radiated Emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.26 mW |

Bluetooth Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
BT Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
BT Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter