
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC ID: RODSI412 Ophoto1 Ophoto2
FCC ID: RODSI412 Iphoto1 Iphoto2 FCC ID: RODSI412 Iphoto3 Iphoto4 FCC ID: RODSI412 Iphoto5 Iphoto6 FCC ID: RODSI412 Iphoto7 Iphoto8
• The test results reported in this report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. • This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited. • The evaluation data of the report will be kept for 3 years from the date of issuance. FCC ID: RODSI412 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com Sun Luen Electrical Mfg. Co., Ltd. Application For Certification (FCC ID: RODSI412) RF Lighting Device 0318435 CKL/kl January 2, 2004 INTERTEK TESTING SERVICES FCC ID: RODSI412 i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1: General Description EXHIBIT 2: System Test Configuration EXHIBIT 3: Emission Results EXHIBIT 4: Equipment Photographs EXHIBIT 5: Product Labelling EXHIBIT 6: Technical Specifications EXHIBIT 7: Instruction Manual INTERTEK TESTING SERVICES FCC ID: RODSI412 ii MEASUREMENT/TECHNICAL REPORT Sun Luen Electrical Mfg. Co., Ltd. - MODEL: SI412 FCC ID: RODSI412 January 2, 2004 This report concerns (check one:) Original Grant X Class II Change Equipment Type: RF Lighting Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Report prepared by: C. K. Lam Intertek Testing Services 2/F., Garment Center, 576, Castle Peak Road, HONG KONG Phone: 852-2173-8512 Fax: 852-2742-6487 INTERTEK TESTING SERVICES FCC ID: RODSI412 iii Table of Contents 1.0 General Description..............................................................................................................2 1.1 Product Description...........................................................................................................2 1.2 Related Submittal(s) Grants.............................................................................................2 1.3 Test Methodology..............................................................................................................3 1.4 Test Facility........................................................................................................................3 1.5 Equipment List...................................................................................................................4 2.0 System Test Configuration.................................................................................................6 2.1 Justification.........................................................................................................................6 2.2 EUT Exercising Software..................................................................................................6 2.3 Special Accessories..........................................................................................................6 2.4 Equipment Modification....................................................................................................7 2.5 Support Equipment List and Description........................................................................7 3.0 Emission Results..................................................................................................................9 3.1 Line Conducted Configuration Photograph (cont’d)...................................................10 3.2 Line Conducted Emission Data....................................................................................11 4.0 Equipment Photographs..................................................................................................12 5.0 Product Labelling...............................................................................................................14 6.0 Technical Specifications..................................................................................................16 7.0 Instruction Manual.............................................................................................................18 INTERTEK TESTING SERVICES FCC ID: RODSI412 iv List of attached file Exhibit type File Description filename Test Report Test Report report.pdf Operation Description Technical Description descri.pdf Test Setup Photo Conducted Emission conducted photos.pdf Test Report Conducted Emission Test Result conducted.pdf External Photo External Photo external photos.pdf Internal Photo Internal Photo internal photos.pdf Block Diagram Block Diagram block.pdf Schematics Circuit Diagram circuit.pdf ID Label/Location Label Artwork and Location label.pdf User Manual User Manual manual.pdf INTERTEK TESTING SERVICES FCC ID: RODSI412 1 EXHIBIT 1 GENERAL DESCRIPTION INTERTEK TESTING SERVICES FCC ID: RODSI412 2 1.0 General Description 1.1 Product Description The equipment under test (EUT) is an Table Lamp. The EUT is operated with 88 KHz and powered by 120V. For electronic filing, the brief circuit description is saved with filename: descri.pdf 1.2 Related Submittal(s) Grants This is a single application for certification of a consumer RF lighting equipment. INTERTEK TESTING SERVICES FCC ID: RODSI412 3 1.3 Test Methodology Both AC mains line-conducted and radiated emission measurements were performed according to the procedures in MP-5. All measurements were performed in Open Area Test Sites. Preliminary scans were performed in the Open Area Test Sites only to determine worst case modes. For each scan, the procedure for maximizing emissions in Appendices D and E were followed. All Radiated tests were performed at an antenna to EUT distance of 3 meters, unless stated otherwise in the "Justification Section" of this Application. 1.4 Test Facility The open area test site and conducted measurement facility used to collect the emission data is located at Garment Centre, 576 Castle…
Text truncated - open the document above for the full version.
INTERTEK TESTING SERVICES Front View Side View INTERTEK TESTING SERVICES Back View
2/F., Garment Centre · Kowloon · Hong Kong
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.087 MHz - 0.089 MHz | - |

Table Lamp
Equipment Class
8CC - Part 18 Consumer Device
TABLE LAMP
Equipment Class
8CC - Part 18 Consumer Device
TABLE LAMP
Equipment Class
8CC - Part 18 Consumer Device
TABLE LAMP
Equipment Class
8CC - Part 18 Consumer Device
FLOOR LAMP
Equipment Class
8CC - Part 18 Consumer Device