FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Landis + Gyr, Inc./
  3. ROV-CLTR900M

ROV-CLTR900MDigital transmission transmitter

Landis + Gyr, Inc.
Digital transmission transmitter - FCC ID ROV-CLTR900M - Landis + Gyr, Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 10, 2004
Application Purpose
Original Equipment
Date of Application
Nov 10, 2004
Equipment Note
Digital transmission transmitter
Frequency Range
913.98000000 - 917.58000000
Company
Landis + Gyr, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FOCUS kWh Solid-State Meter Technical Manual Bulletin 160 Revision 2.1 i Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose without the express written permission of Landis+Gyr, Inc.. © 2003 Landis+Gyr, Inc. All rights reserved. For further information, contact: Landis+Gyr, Inc. Meter Division 2800 Duncan Road Lafayette, IN 47904-5012 USA Tel. 765-742-1001 Document History Title: FOCUS Solid State Meter Technical Manual Document Number: Bulletin 160 Revision Date Description Level Issued Original (1.0) 1/04 Initial Issue 2.0 10/19/04 Rev. Cellnet FCC# 2.1 11/8/04 add note #3 to FCC info. ii ii TABLE OF CONTENTS PURPOSE............................................................................................................................V TARGET GROUP...................................................................................................................V CONDITIONS......................................................................................................................VI SAFETY WARNINGS.............................................................................................................VI PUBLISHED SPECIFICATIONS..................................................................................................VI INSTITUTE FOR ELECTRICAL AND ELECTRONIC ENGINEERS (IEEE) ................................................VI AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ...............................................................VII UNDERWRITERS LABORATORIES (UL).....................................................................................VII CANADIAN SPECIFICATIONS..................................................................................................VII FCC INFORMATION: ...........................................................................................................VII 1. INTRODUCTION TO THE FOCUS..................................................................................... 1 BASEPLATE ASSEMBLY........................................................................................................... 2 ELECTRONIC HOUSING ASSEMBLY............................................................................................ 3 2. THE FOCUS METER FAMILY........................................................................................... 4 REGISTER TYPES.................................................................................................................. 4 3. METER ASSEMBLY........................................................................................................ 5 REMOVAL OF THE ELECTRONICS HOUSING FROM THE BASEPLATE................................................... 5 INSTALLATION OF THE ELECTRONICS HOUSING ONTO THE BASEPLATE............................................. 5 SEALING THE METER............................................................................................................. 5 4. APPLICATION INFORMATION........................................................................................... 8 AVAILABLE METER FORMS...................................................................................................... 8 4.1.1. S-BASE................................................................................................................. 8 4.1.2. K-BASE................................................................................................................. 8 METER FORM SCHEMATIC DIAGRAMS....................................................................................... 8 INSTALLATION PROCEDURES................................................................................................. 11 iii iii 4.1.3. SOCKET BASE........................................................................................................ 11 4.1.4. K-BASE............................................................................................................... 12 5. OVERVIEW OF ELECTRONIC HARDWARE.......................................................................... 13 5.1.1. LCD DISPLAY....................................................................................................... 13 5.1.2. DISPLAY SCROLL SEQUENCE: ................................................................................... 13 5.1.3. DISPLAY FORMAT.................................................................................................. 14 5.1.4. DIGITAL POWER INDICATOR.................................................................................... 14 5.1.5. POWER UP DISPLAY SEQUENCE................................................................................ 14 DIAGNOSTICS/ERROR CODES............................................................................................... 15 5.1.6. METER ERRORS..................................................................................................... 15 5.1.7. ERROR CODE MAPPING............................................ERROR! BOOKMARK NOT DEFINED. 5.1.8. ERROR DISPLAY, POWER OUTAGE COUNTER, AND USER ACCESS..................................... 15 6. CONFIGURING THE METER............................................................................................ 16 6.1. CONFIGURATION PORT............................................................................................ 16 INITIAL POWER-UP AND OPERATION...................................................................................... 16 6.1.2 BILLING DATA RESET/PRESET.................................................................................. 16 6.1.3 DISPLAY MULTIPLIER............................................................................................. 16 7. METER CALIBRATION.................................................................................................. 17 CALIBRATION LED .................…

Text truncated - open the document above for the full version.

External Photos

Authorized Agent: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] External EUT Photographs FCC ID: ROV- CLTR900M Front of EUT: Protective Cover removed Rear of EUT Authorized Agent: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] Meter mounted in Socket

ID Label/Location Info

Authorized Agent: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] ID Label/Location FCC ID: ROV-CLTR900M Photograph of FCC Label: FCC ID: ROV-CLTR900M Radiometrics Midwest Corporation (815) 293-0772 – [email protected] Label Specifications: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] Radiometrics Midwest Corporation (815) 293-0772 – [email protected] Photograph of Label as mounted on EUT

Internal Photos

Authorized Agent: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] Internal EUT Photographs FCC ID: ROV-CLTR900M Transmitter PCB Authorized Agent: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] Meter and Transmitter PCBs Connected Authorized Agent: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] Meter Board Meter Board – Shield Removed Authorized Agent: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] Inside of Front Cover Meter and Transmitter Inside Cover Authorized Agent: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] Bottom of Meter

Test Report

Authorized Agent: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] RF exposure FCC ID: The output power of the EUT is 205 mW and the gain of the antenna is 1.5 dBi The following information provides the minimum separation distance for the EUT, as calculated from FCC OET 65 Appendix B, Table 1B “Guidelines for General Population/Uncontrolled Exposure” This calculation is based on the highest EIRP possible from the EUT considering maximum power and antenna gain. The formulas were used: GP limit is = 0.61 mW/cm^2 for 917 MHz (from F/1500) Pwatts*Ggain or ERP = 10^(PdBm-30+GdBi)/10) =0.288 Watts 0.316 Watts = 24.6 dBm S= E^2/3770 mW/cm^2 E or V/m = (ERP*30)^0.5/d, (d in meters) d = ((ERP*30)/3770*S))^0.5 MSD = 0.061 meters SMaximum AntennaMSD Freq.GP limitRF power GainERPEd MHzmW/cm^2 dBmdBiwattsV/mmeters 9270.61823.11.50.28848.30.061 GP is the limit for general Population/Uncontrolled Exposure MSD is the minimum Seperation Distance NOTE: For mobile or fixed location transmitters, minimum separation distance is 20 cm, even if calculations indicate MPE distance is less

Test Report

Radiometrics Midwest Corporation (815) 293-0772 – www.radiomet.com Page 1 of 21 Electromagnetic Compatibility Test Report Tests Performed on a Landis +Gyr Focus Meter with Cellnet DSSS Radio Retrofit, Model 40-1024 Radiometrics Document RP-5378 Product Detail: FCC ID: ROV-CLTR900M Equipment type: 906 to Digitally Modulated Transmitter. Test Standards: US CFR Title 47, Chapter I, FCC Part 15 Subpart C FCC Part 15 CFR Title 47: 2004 This report concerns: Original Grant for Certification FCC Part 15.247 Tests Performed For: Test Facility: Landis +Gyr, Inc. 2800 Duncan Road Lafayette, IN 47904 Phone: (765) 429-1378 Radiometrics Midwest Corporation 12 East Devonwood Romeoville, IL 60446 Phone: (815) 293-0772 e-mail: [email protected] Test Date(s): (Month-Day-Year) September 22 and 23, 2004 Document RP-5378 Revisions: Rev. Issue Date Affected Pages Revised By Authorized Signature for Revision 0 October 6, 2004 1 October 13, 2004 9, 10, 13 Joseph Strzelecki 2 October 15, 2004 4, 5, 12, 19 Joseph Strzelecki RADIOMETRICS MIDWEST CORPORATION - EMC Test Report Testing of the Landis +Gyr, Focus Meter with Cellnet DSSS Radio Retrofit RP-5378 Rev. 0 Page 2 of 21 Table of Contents 1 ADMINISTRATIVE DATA ................................................................................................................... 3 2 TEST SUMMARY AND RESULTS .....................................................................................................3 2.1 RF Exposure Compliance Requirements ..................................................................................... 3 3 EQUIPMENT UNDER TEST (EUT) DETAILS .................................................................................... 4 3.1 EUT Description ........................................................................................................................... 4 3.1.1 FCC Section 15.203 Antenna Requirements......................................................................... 4 3.2 Related Submittals ....................................................................................................................... 4 4 TESTED SYSTEM DETAILS .............................................................................................................. 4 4.1 Tested System Configuration ....................................................................................................... 4 4.2 Special Accessories ..................................................................................................................... 5 4.3 Equipment Modifications .............................................................................................................. 5 5 TEST SPECIFICATIONS AND RELATED DOCUMENTS.................................................................. 5 6 RADIOMETRICS’ TEST FACILITIES .................................................................................................5 7 DEVIATIONS AND EXCLUSIONS FROM THE TEST SPECIFICATIONS......................................... 6 8 CERTIFICATION ................................................................................................................................ 6 9 TEST EQUIPMENT TABLE ................................................................................................................ 6 10 TEST SECTIONS ............................................................................................................................. 7 10.1 AC Conducted Emissions; Section 15.207................................................................................. 7 Figure 1. Conducted Emissions Test Setup.................................................................................... 8 10.2 Occupied Bandwidth (6 dB)........................................................................................................ 8 10.3 Power Spectral Density ............................................................................................................ 10 10.4 Peak Output Power .................................................................................................................. 11 10.5 Band-edge Compliance of RF Conducted Emissions .............................................................. 12 10.6 Spurious RF Conducted Emissions.......................................................................................... 13 10.7 Spurious Radiated RF Emissions.............................................................................................17 10.7.1 Field Strength Calculation.................................................................................................. 18 10.7.2 Spurious Radiated Emissions Test Results (Restricted Band) .......................................... 18 Figure 2. Drawing of Radiated Emissions Setup .......................................................................... 21 Notice: This report must not be reproduced (except in full) without the written approval of Radiometrics Midwest Corporation. RADIOMETRICS MIDWEST CORPORATION - EMC Test Report Testing of the Landis +Gyr, Focus Meter with Cellnet DSSS Radio Retrofit RP-5378 Rev. 0 Page 3 of 21 1 ADMINISTRATIVE DATA Equipment Under Test: A Landis +Gyr, Focus Meter with Cellnet DSSS Radio Retrofit Model: 40-1024 Serial Number: 86 703 807 This will be referred to as the EUT in this Report Date EUT Received at Radiometrics: (Month-Day-Year) Test Date(s): (Month-Day-Year) September 22, 2004 September 22 and 23, 2004 Test Report Written By: Test Witnessed By: Joseph Strzelecki Senior EMC Engineer Saieb Alrawi Landis +Gyr Radiometrics’ Personnel Responsible for Test: Test Report Approved By Joseph Strzelecki Senior EMC Engineer NARTE EMC-000877-NE Chris W. Carlson Director of Engineering NARTE EMC-000921-NE 2 TEST SUMMARY AND RESULTS The EUT (Equipment Under Test) is a Focus Meter with Cellnet DSSS Radio Retrofit, Model 40-1024, manufactured by Landis +Gyr. The detailed test results are presented in a separate section. The following…

Text truncated - open the document above for the full version.

Test Setup Photos

Authorized Agent: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] Test Setup Photographs FCC ID: ROV-CLTR900M Photographs of Radiated Emissions Test Setup Authorized Agent: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] Photograph of Conducted Emissions Test Setup Authorized Agent: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] Photograph of Antenna Conducted Emissions Test Setup

Contact Information

Applicant

Saieb AlRawi(Sr. Product Engineer)
[email protected]765-429-1378Fax: 765-429-1344

Technical Contact

Radiometrics Midwest CorporationJoseph Strzelecki
[email protected]815-293-0772

12 East Devonwood Ave · Romeoville, Illinois · United States

Non-Technical Contact

Radiometrics Midwest CorporationJoan Strzelecki
[email protected]815-293-0772

Test Firm

Radiometrics Midwest Corp.Joseph Strzelecki
[email protected]8152930772Fax: 8152930820

Technical Specifications

#Rule PartsFrequency RangePower Output
115C913.98 MHz - 917.58 MHz204.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. This device and its antenna must not be colocated or operating in conjunction with any other antenna or transmitter. End-users must be provided with specific operating instructions for satisfying RF exposure compliance.

Other Applications from Landis + Gyr, Inc.

Meter with Utilinet transmitter - FCC ID ROV-UTTR900M - Landis + Gyr, Inc.
ROV-UTTR900M

Meter with Utilinet transmitter

Aug 04, 2004

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Focus StatSignal - FCC ID ROV-1MWR9165 - Landis + Gyr, Inc.
ROV-1MWR9165

Focus StatSignal

Feb 23, 2004

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter