FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Mertik Maxitrol GmbH & Co. KG/
  3. RTD-B6R

RTD-B6RHandset of remote electronic ignition and control system for gas applications

Mertik Maxitrol GmbH & Co. KG
Handset of remote electronic ignition and control system for gas applications - FCC ID RTD-B6R - Mertik Maxitrol GmbH & Co. KG
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Mar 04, 2014
Application Purpose
Original Equipment
Date of Application
Mar 04, 2014
Equipment Note
Handset of remote electronic ignition and control system for gas applications
Frequency Range
915.00000000 - 915.00000000
Company
Mertik Maxitrol GmbH & Co. KG
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. 1 / 28 GV60 Remote Electronic Ignition and Control System R R 8-SYMBOL .........................................................................................19 Setting Celsius or Fahrenheit ..............................................................19 Setting the Time ..................................................................................19 Modes of Operation .............................................................................19 Manual Mode .......................................................................................20 Thermostatic Mode ..............................................................................21 Countdown Timer ................................................................................21 Program Mode .....................................................................................21 Random Flame .....................................................................................22 Auxiliary Feature ..................................................................................22 Child Proof ...........................................................................................22 10-SYMBOL .......................................................................................23 Setting Celsius or Fahrenheit ..............................................................23 Setting the Time ..................................................................................23 Modes of Operation .............................................................................23 Manual Mode .......................................................................................24 Thermostatic Mode ..............................................................................25 Countdown Timer ................................................................................25 Program Mode .....................................................................................25 Circulating Fan Operation ...................................................................26 Light/Dimmer Operation ......................................................................26 Random Flame .....................................................................................26 Auxiliary Feature ..................................................................................26 Child Proof ...........................................................................................26 TOUCH PAD / WALL SWITCH ............................................................27 SWITCH PANEL ..................................................................................27 Manual Operation ................................................................................28 To Turn off Gas to Appliance ...............................................................28 Automatic Turn Down ..........................................................................28 Automatic Shut Off ..............................................................................28 INSTALLATION INSTRUCTIONS Application .............................................................................................3 Components .......................................................................................... 3 Technical Specifications ........................................................................ 4 Gas Connections ................................................................................... 5 Perform Gas Leak Test ......................................................................... 6 Wiring Connections ............................................................................... 6 Gas Control Knob Settings .................................................................. 11 Adjustment ........................................................................................... 11 Final Check .......................................................................................... 12 OPERATING INSTRUCTIONS General Notes ..................................................................................... 13 Setting the Electronic Code .................................................................13 4-SYMBOL .........................................................................................14 Setting Celsius or Fahrenheit ..............................................................14 Setting the Time ..................................................................................14 Manual Mode .......................................................................................14 Countdown Timer ................................................................................15 Child Proof ...........................................................................................15 6-SYMBOL .........................................................................................16 Setting Celsius or Fahrenheit ..............................................................16 Setting the Time ..................................................................................16 Modes of Operation .............................................................................16 Manual Mode .......................................................................................17 Thermostatic Mode ..............................................................................17 Countdown Timer ................................................................................18 Program Mode .....................................................................................18 Child Proof ...........................................................................................18 CONTENTS INSTALLATION AND OPERATING INSTRUCTIONS FOR OEM USE ONLY Draft November 4, 2013 © 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. 2 / 28 IMPORTANT SAFETY INFORMATION FOR OEM USE ONLY Read these instru…

Text truncated - open the document above for the full version.

Users Manual

OPERATING INSTRUCTIONS FOR OEM USE ONLY © 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. 16 / 28 SETTING CELSIUS OR FAHRENHEIT 1 2 ON AM PM OFF To change between °C and °F, press and buttons simultaneously. NOTE: Choosing °F results in a 12 hour clock. Choosing °C results in a 24 hour clock. SETTING THE TIME 1 2 ON AM PM OFF 1. Press and buttons simultane- ously. Hour fl ashes. 2. To select hour press or button. 3. Press and buttons simultane- ously. Minutes fl ash. 4. To select minutes press or but- ton. 5. To confi rm press and buttons simultaneously or wait. MODES OF OPERATION 1 2 ON AM PM OFF Enter Mode Press the appropriate mode button. Exit Mode 1. Press the same mode button again to change to Manual mode. 2. Press or button to change to Manual mode. 3. Press a different mode button to change to that mode. 1 2 ON AM PM OFF Thermostatic Mode The room temperature is measured and compared to the set temperature. The fl ame height is then automatically ad- justed to achieve the set temperature. 1 2 ON AM PM OFF Program Mode Programs 1 and 2, each can be pro- grammed to go ON and OFF at specifi c times at a set temperature. 6-SYMBOL Figure 21: 6-symbol Display Program Mode Temperature Time Countdown Timer Battery Status Signal Indicator Child Proof Thermostatic Mode 1 2 ON AM PM OFF °F or °C OPERATING INSTRUCTIONS FOR OEM USE ONLY © 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. 17 / 28 6-SYMBOL MANUAL MODE (HANDSET) NOTICE BEFORE OPERATING 1. Make sure MANUAL knob on the GV60 Valve is in the ON, full counterclockwise position. 2. Place the ON/OFF switch (if equipped) in the “I” (ON position). TO TURN ON FIRE When pilot ignition is confi rmed, motor turns automatically to maximum fl ame height. 1 2 ON AM PM OFF Handset ▪ Press button until a short beep con- fi rms the start sequence has begun; release button. ▪ Continuing beeps confi rm ignition is in process. ▪ Rotating circle is shown on display un- til ignition sequence is complete. ▪ There is main gas fl ow once pilot igni- tion is confi rmed. ▪ Handset automatically goes into Man- ual mode after main burner ignition. If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions “TURN OFF GAS TO APPLIANCE” (page 28). Standby Mode (Pilot Flame) Handset ▪ Press and hold button to set appliance to pilot fl ame. TO TURN OFF FIRE 1 2 ON AM PM OFF Handset ▪ Press button to turn off. NOTE: There is a 5 sec delay before the next ignition is possible. FLAME HEIGHT ADJUSTMENT 1 2 ON AM PM OFF Handset ▪ To increase fl ame height press and hold button. ▪ To decrease fl ame height or to set ap- pliance to pilot fl ame, press and hold button. DESIGNATED LOW FIRE AND HIGH FIRE AM ▪ To go to low fi re, double-click but- ton. “LO” is displayed. NOTE: Flame goes to high fi re fi rst be- fore going to low fi re. AM ▪ To go to high fi re, double-click but- ton. “HI” is displayed. If the appliance will not operate, follow the instructions “TURN OFF GAS TO APPLIANCE” (page 28). THERMOSTATIC MODE 1 2 ON AM PM OFF ON: Press button. Thermostat icon dis- played, preset temperature displayed briefl y, and then room temperature dis- played. OFF: 1. Press button. 2. Press or button to enter Manual mode. 3. Press button to enter Countdown Timer mode. 1 2 ON AM PM OFF SETTING: 1. Press button and hold until Ther- mostat icon displayed, temperature fl ashes. 2. To adjust SET temperature press or button. 3. To confi rm press button or wait. OPERATING INSTRUCTIONS FOR OEM USE ONLY © 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. 18 / 28 1 2 ON AM PM OFF Time SETTING: 1. Press button and hold until , , displayed, hour fl ashes. 2. To select hour press or button. 3. To confi rm press button. , dis- played, minutes fl ash. 4. To select minutes press or but- ton. 1 2 ON AM PM OFF 5. To confi rm press button. , , displayed, hour fl ashes. 6. To select hour, press or button. 7. To confi rm press button. , , displayed, minutes fl ash. 8. To select minutes press or but- ton. NOTE: If you stop programming at this point, program 2 remains deactivated. NOTE: Programs 1 and 2 use the same ON (Thermostatic) and OFF temperatures. 1 2 ON AM PM OFF 1. To continue to program , press button. , , displayed, hour fl ashes. 2. To select hour press or button. 3. To confi rm press button. , , displayed, minutes fl ash. 4. To select minutes, press or but- ton. 5. To confi rm press button. , , displayed, hour fl ashes. 6. To select hour, press or button. 7. To confi rm press button. , , displayed, minutes fl ash. 8. To select minutes, press or but- ton. 9. To confi rm press button or wait. NOTE: Programs and use the same ON and OFF tempera- tures. Once an ON and/or OFF temperature has been set, that temperature becomes the new default setting. CHILD PROOF 1 2 ON AM PM OFF ON: To activate press and buttons si- multaneously. Children icon displayed and the handset is rendered inoper- able, except for the OFF function. OFF: To deactivate press and buttons simultaneously. Children icon disap- pears. COUNTDOWN TIMER 1 2 ON AM PM OFF ON/SETTING: 1. Press and hold button until hour- glass icon displayed and hour fl ashes. 2. To select hour press or button. 3. To confi rm press button. Minutes fl ash. 4. To select minutes press or button. 5. To confi rm press button or wait. OFF: Press button, hourglass and count- down time disappear. NOTE: At end of countdown time period, the fi re turns OFF. The CountdownTimer only works in Manual, Thermostatic, and Random modes. Maximum countdown time is 9 hours. PROGRAM MODE NOTE: The set temperature for Thermostatic Mode is the tem- perature for the ON time in Program Mode. Changing the Thermostatic Mode set temperature also changes the ON time temperature in Program Mode. 1 2 ON AM PM OFF ON: Press button. , or , ON or OFF displayed. 1 2 ON AM PM OFF OFF: 1. Press or or button to enter Manual mode. 2. Press button to enter Thermostatic mode. 3. Press Random icon button to enter Ra…

Text truncated - open the document above for the full version.

Cover Letter(s)

Request for Confidentiality Date: 05.02.2014 Subject: Confidentiality Request for: FCC ID: RTD-B6R IC: 4943A-B6RH9 ______ Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 1 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent* User’s Manual *Note: ______(Insert Explanation as Necessary)______ MERTIK MAXITROL GmbH & Co. KG has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of (0) days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, By: Manager Certification Thomas Ring Title Name 1 - The asterisked items (*) require further justification before permanent confidentiality will be allowed. These also currently require review by the FCC under their Permit-But-Ask policy before the grant is issued and can delay completion of an application. Further justification should be added to the note above. One such example for a potted device would be: “The EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline the device before and after potting.”

External Photos

FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 6 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- 3 E Q U I P M E N T U N D E R T E S T 3.1 Photo documentation of the EUT External view:

ID Label/Location Info

B6R-H9DModel: 915 MHz amb.temp.0...60°C 3V DC date1204 B B FCC ID: RTD-B6R IC: 4943A-B6RH9 Made in Germany 3V DC date1204 B B B6R-H9TV 915 MHz amb.temp.0...60°C Model: Made in Germany IC: 4943A-B6RH9 FCC ID: RTD-B6R Full Version (Max)10 Button B6R-H9TV Thermostat,Fan,2 Burner,LED,Dimmer,Powerflue Thermostatversion (Classic) B6R-H9T 6 Button Display(Basic) B6R-H9D 4 Button Thermostatversion 2 Burner B6R-H9TL 8 Button 3V DC date1204 B B 915 MHz amb.temp.0...60°C B6R-H9TModel: Made in Germany IC: 4943A-B6RH9 FCC ID: RTD-B6R 3V DC date1204 B B 915 MHz amb.temp.0...60°C B6R-H9TLModel: Made in Germany IC: 4943A-B6RH9 FCC ID: RTD-B6R Date / Datum 15.01.2014 CONFIDENTIAL MERTIK MAXITROL INTELLECTUAL PROPERTY COPYRIGHT - VERTRAULICH GEISTIGES EIGENTUM VON MERTIK MAXITROL COPYRIGHT Application / Verwendungsbereich: Index Revision / Änderungsnr. Date / Datum Approval / Freigabe Approval / Freigabe Drawing / Erstellt Name Keil Tolerance / Zul. Abweichung: DIN ISO 2768-m Surface / Oberfläche: Scale / Maßstab: 1:1 Weight / Gewicht: 0.00 Semi-Finished Material / Halbzeug: Substance / Werkstoff Part Name / Benennung: Zeichnung Varianten Drawing-No. / Zeichungs-Nr.: B6R-SKFV 1 of / von 1 Sheet / Blatt R g

ID Label/Location Info

Position für Label

Internal Photos

FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 7 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- Internal view: FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 8 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013-

Test Report

FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 1 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- EMI − T E S T R E P O R T - FCC Part 15.249, RSS210 - Test Report No. : T36931-00-02KG 19. December 2013 ______________________________________________________________________________________________ Date of issue Type / Model Name : Handset / B6R Product Description : Handset of remote electronic ignition and control system for gas applications Applicant : Plättner Elektronik GmbH Address : Lerchenbreite 8 38889 BLANKENBURG, GERMANY Manufacturer : Mertik Maxitrol GmbH & Co. KG Address : Warnstedter Strasse 3 06502 THALE, GERMANY Licence holder : Mertik Maxitrol GmbH & Co. KG Address : Warnstedter Strasse 3 06502 THALE, GERMANY Test Result according to the standards listed in clause 1 test standards: POSITIVE The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permission of the test laboratory. FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 2 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- Contents 1 T E S T S T A N D A R D S 3 2 S U M M A R Y 4 2.1 GENERAL REMARKS: 4 2.2 Test result summery 4 2.3 FINAL ASSESSMENT: 5 3 E Q U I P M E N T U N D E R T E S T 6 3.1 Photo documentation of the EUT 6 3.2 Power supply system utilised 9 3.3 Short description of the equipment under test (EUT) 9 4 T E S T E N V I R O N M E N T 10 4.1 Address of the test laboratory 10 4.2 Environmental conditions 10 4.3 Statement of the measurement uncertainty 10 4.4 Measurement protocol for FCC and IC 11 4.5 Determination of worst case measurement conditions 11 5 T E S T C O N D I T I O N S A N D R E S U L T S 13 5.1 Conducted emissions 13 5.2 Radiated emission of the fundamental wave 13 5.3 Spurious emissions radiated 15 5.4 EBW and OBW 18 5.5 Correction for pulse operation (duty cycle) 21 6 U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S 24 FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 3 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules and Regulations Part 15, Subpart A - General (September, 2013) Part 15, Subpart A, Section 15.31 Measurement standards Part 15, Subpart A, Section 15.33 Frequency range of radiated measurements Part 15, Subpart A, Section 15.35 Measurement detector functions and bandwidths FCC Rules and Regulations Part 15, Subpart C - Intentional Radiators (September, 2013) Part 15, Subpart C, Section 15.203 Antenna requirement Part 15, Subpart C, Section 15.204 External radio frequency power amplifiers and antenna modifications Part 15, Subpart C, Section 15.205 Restricted bands of operation Part 15, Subpart C, Section 15.207 Conducted limits Part 15, Subpart C, Section 15.209 Radiated emission limits, general requirements Part 15, Subpart C, Section 15.249 Operation within the bands 902 - 928 MHz, 2400 - 2483.5 MHz, 5725 - 5875 MHz, and 24.0 - 24.25 GHz ANSI C63.4: 2003 Methods of Measurement of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. ANSI C95.1:2005 IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz CISPR 16-4-2: 2003 Uncertainty in EMC measurement CISPR 22: 2005 Information technology equipment EN 55022: 2006 FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 4 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- 2 S U M M A R Y 2.1 GENERAL REMARKS: None 2.2 Test result summery Operating in the 902 MHz – 928 MHz band: FCC Rule Part RSS Rule Part Description Result 15.35(c) RSS-Gen, 4.5 Pulsed operation passed 15.205(a) RSS-Gen, 7.2.2 Emissions in restricted bands passed 15.207(a) RSS Gen, 7.2.4 AC power line conducted emissions passed 15.215(c) -20 dBc EBW passed RSS-Gen, 4.6.1 99 % Bandwidth passed 15.249(a) RSS-210, A2.9(a) Field strength of fundamental passed 15.249(d) RSS Gen, 7.2.5 Out-of-band emission, radiated passed RSS-Gen, 7.2.6 Transmitter frequency stability not applicable The mentioned RSS Rule Parts in the above table are related to: RSS Gen, Issue 3, December 2010 RSS 210, Issue 8, December 2010 RSS 102, Issue 4, March 2010 FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 5 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- 2.3 FINAL ASSESSMENT: The equipment under test fulfills the EMI requirements cited in clause 1 test standards. Date of receipt of test sample : acc. to storage records Testing commenced on : 18. October 2013 Testing concluded on : 12. December 2013 Checked by: Tested by: Thomas Weise Dipl.-Ing.(FH) Laboratory Manager Klaus Gegenfurtner Dipl.-Ing.(FH) FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 6 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- 3 E Q U I P M E N T U N D E R T E S T 3.1 Photo documentation of the EUT External view: FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 7 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- Internal view: FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 8 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- FCC ID: RTD-B6R IC ID: 4943A-B6RH9 C…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 13 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- 5 T E S T C O N D I T I O N S A N D R E S U L T S 5.1 Conducted emissions For test instruments and accessories used see section 6 Part A 4. 5.1.1 Description of the test location Test location: NONE Remarks: Not applicable, the EUT is battery powered. 5.2 Radiated emission of the fundamental wave For test instruments and accessories used see section 6 Part CPR 2. 5.2.1 Description of the test location Test location: OATS 1 Test distance: 3 m 5.2.2 Photo documentation of the test set-up FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 15 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- 5.3 Spurious emissions radiated For test instruments and accessories used see section 6 Part SER 1, SER 2, SER 3. 5.3.1 Description of the test location Test location: OATS 1 Test location: Anechoic chamber 2 Test distance: 3 m 5.3.2 Photo documentation of the test set-up Test setup 9 kHz – 30 MHz: Test setup 30 MHz – 1000 MHz: FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 16 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- Test setup 1 GHz – 18 GHz: 5.3.3 Applicable standard According to FCC Part 15C, Section 15.249 (d): Emission radiated outside of the specified frequency bands, except harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the general radiated limit in FCC Part 15C, Section 15.209, whichever is the lesser attenuation. 5.3.4 Description of Measurement The radiated emissions from the EUT are measured in the frequency range of 9 kHz to 1000 MHz using a tuned receiver and appropriate broadband linearly polarized antennas. The setup of the EUT and the measurement procedure is in accordance to ANSI C63.4, Item 8.3. In the frequency range above 1 GHz a spectrum analyser is used with appropriate linear polarized antennas. If the emission level in peak mode complies with the average limit testing is stopped and peak values will be reported, otherwise, the emission is measured in average mode again and reported. The EUT is measured in TX continuous mode unmodulated under normal conditions. Instrument settings: 9 kHz – 150 kHz RBW: 200 Hz 150 kHz - 30 MHz RBW: 9 kHz 30 MHz – 1000 MHz: RBW: 120 kHz 1000 MHz – 10 GHz RBW: 1 MHz 5.3.1 Test result f < 30 MHz Frequency (kHz) L: PK (dBμV) L: AV (dBμV) Bandwidth (kHz) Correct. (dB) L: PK dB(μV/m) L: AV dB(μV/m) Limit AV dB(μV/m) Delta (dB) 536.8 24.1 19.7 9.0 20.0 44.1 39.7 73.0 -33.3 1073.6 23.4 18.0 9.0 20.0 43.4 38.0 67.0 -29.0 1342.0 21.6 15.9 9.0 20.0 41.6 35.9 65.0 -29.1 Note: In the frequency range 9 kHz to 30 MHz no emission from the EuT could be detected. Therefore only ambient noises are reported. FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 18 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- 5.4 EBW and OBW For test instruments and accessories used see section 6 Part MB. 5.4.1 Description of the test location Test location: AREA4 5.4.2 Photo documentation of the test set-up 5.4.3 Applicable standard According to FCC Part 15, Section 15.215(c): Intentional radiators operating under the alternative provisions to the general emission limits, as contained in Section 15.217 through Section 15.257, must be designed to ensure that the 20 dB bandwidth of the emission is contained within the frequency band designated in the rule section under which the equipment is operated. According to RSS-Gen, Section 4.6.1: When an occupied bandwidth value is not specified in the applicable RSS, the transmitted signal bandwith to be reported is to be its 99% emission bandwidth, as calculated or measured. 5.4.4 Description of Measurement The bandwidth is measured at an amplitude level reduced from the reference level by a specified ratio of -20 dB (99%). The x-dB-down (OBW) function of the analyser is used. The measurement is performed with normal modulation in TX continuous mode. FCC ID: RTD-B6R IC ID: 4943A-B6RH9 CSA Group Bayern GmbH File No. T36931-00-02KG, page 21 of 24 Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY Tel.:+49(0)9424-94810  Fax:+49(0)9424-9481440 Rev. No. 3.0, 2013- 5.5 Correction for pulse operation (duty cycle) For test instruments and accessories used see section 6 Part DC. 5.5.1 Description of the test location Test location: AREA4 5.5.2 Photo documentation of the test set-up 5.5.3 Applicable standard According to FCC Part 15A, Section 15.35(c): When the radiated emission limits are expressed in terms of average value and pulsed operation is employed, the measurement field strength shall be determined by averaging over one complete puls train, including blanking intervals, as long as the pulse train does not exceed 0.1s. in cases where the puls train exceeds 0.1s, the measured field strength shall be determined from the average absolute voltage during a 0.1s interval during which the field strength is at its maximum. The exact method of calculating the average field strength shall be submitted.

Contact Information

Applicant

Barbara Happe(Group Leader Development Gas Controls)
[email protected]49 3947 400 335Fax: 49 3947 400 200

Technical Contact

CSA Group Bayern GmbHKlaus Gegenfurtner
[email protected]

Germany

Test Firm

CSA Group Bayern GmbHFrank Scharnowski
[email protected]+49 9931 9836 140Fax: +49 9931 9836 440

Technical Specifications

#Rule PartsFrequency RangePower Output
115C915 MHz - 915 MHz-
Confidentiality
Long Term

Other Applications from Mertik Maxitrol GmbH & Co. KG

Handset of remote electronic ignition and control system for gas applications - FCC ID RTD-G6RH - Mertik Maxitrol GmbH & Co. KG
RTD-G6RH

Handset of remote electronic ignition and control system for gas applications

Feb 12, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
e-Flame - FCC ID RTD-G6RT - Mertik Maxitrol GmbH & Co. KG
RTD-G6RT

e-Flame

May 10, 2004

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
e-Flame - FCC ID RTD-G6R - Mertik Maxitrol GmbH & Co. KG
RTD-G6R

e-Flame

Mar 10, 2004

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter