FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Mertik Maxitrol GmbH & Co. KG/
  3. RTD-G6R

RTD-G6Re-Flame

Mertik Maxitrol GmbH & Co. KG
e-Flame - FCC ID RTD-G6R - Mertik Maxitrol GmbH & Co. KG
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 10, 2004
Application Purpose
Original Equipment
Date of Application
Mar 10, 2004
Equipment Note
e-Flame
Frequency Range
315.00000000 - 315.00000000
Company
Mertik Maxitrol GmbH & Co. KG
Country
Germany

Documents & Files

Select a file to view

Users Manual

β†—

Block Diagram

β†—

Cover Letter(s)

β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Operational Description

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

FCC ID: RTD-G6R File No. T 24275-02-03 XF , Page E 1 of E 4 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 Appendix E1 Complete system with receiver, transmitter and combination control GV60 T 24275-02-03 XF FCC ID: RTD-G6R File No. T 24275-02-03 XF , Page E 2 of E 4 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 Appendix E2 Remote control for the combination control GV60 T 24275-02-03 XF External Photo Front view External Photo Rear view

ID Label/Location Info

FCC ID: RTD-G6R File No. T 24275-02-03 XF , Page E 2 of E 4 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 Appendix E2 Remote control for the combination control GV60 T 24275-02-03 XF External Photo Front view External Photo Rear view

Internal Photos

FCC ID: RTD-G6R File No. T 24275-02-03 XF , Page E 3 of E 5 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 Appendix E3 Remote control for the combination control GV60 T 24275-02-03 XF Internal Photo Open view FCC ID: RTD-G6R File No. T 24275-02-03 XF , Page E 4 of E 5 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 Appendix E4 Remote control for the combination control GV60 T 24275-02-03 XF Internal Photo Front view PCB Internal Photo Rear view PCB FCC ID: RTD-G6R File No. T 24275-02-03 XF , Page E 5 of E 5 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 Appendix E5 Remote control for the combination control GV60 T 24275-02-03 XF Internal Photo Part view of PCB Internal Photo Part view of PCB

Test Report

FCC ID: RTD-G6R DAT - P-011 / 91-02 TTI - P-G 089 / 94-11 File No. T 24275-02-03 XF , Page 1 of 14 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 E M I S S I O N -- T E S T R E P O R T Test Report File No. : T 24275-02-03 XF ________________ Date : February 25, 2004 of issue ________________ Type Designation : e-Flame ______________________________________________ Kind of Product : Electronic remote ignition and control system ______________________________________________ Applicant : Mertik Maxitrol GmbH & Co. KG ______________________________________________ Manufacturer : Mertik Maxitrol GmbH & Co. KG ______________________________________________ Licence holder : Mertik Maxitrol GmbH & Co. KG ______________________________________________ Address : Warnstedter Strasse 3 ______________________________________________ 06502 Thale, Germany ______________________________________________ Test result accdg. to the regulation(s) at page 3 : Positive This test report with attachment consists of 29 pages. The test result only corresponds to the tested sample. It is not permitted to copy this report, in part or in full, without the permission of the test laboratory. FCC ID: RTD-G6R File No. T 24275-02-03 XF , Page 2 of 14 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 D I R E C T O R Y Page Documentation Directory 2 ________ Test regulations 3 ________ General information 4-5 ________ Discovery of worst case condition -- ________ Equipment under Test 13 ________ Summary 14 ________ Test data Conducted emissions 10/150 kHz - 30 MHz 6 ________ Spurious emissions (magnetic field) 9 kHz - 30 MHz 7-8 ________ Spurious emissions (electric field) 30 MHz - 1000 MHz 9 ________ Spurious emissions (electric field) 1 GHz - 18 GHz 10 ________ Radiated power of the fundamental wave 11 ________ Conducted power of the fundamental wave measured on 12 the antenna terminals ________ Attachment A) Test data A1 ________ B) List of Test Equipment B1 ________ C) Photos of the test setup C1-C5 ________ D) Technical description of the test sample D1-D3 (e.g. CDF, Declaration) ________ E) Photos of the EuT E1-E5 ________ F) Measurement Protocol for FCC, VCCI and AUSTEL -- ________ FCC ID: RTD-G6R File No. T 24275-02-03 XF , Page 3 of 14 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 T E S T R E G U L A T I O N S The tests were performed according to following regulations : o - EN 50081-1 / 2.1991 o - EN 50081-2 / 7.1993 -------------------------------------------------------------------------------- o - EN 55011 / 3.1991 o - Group 1 o - Group 2 o - class A o - class B o - EN 55014 / 4.1993 o - Household appliances and similar o - tools o - Semiconductor devices o - EN 55014 / A2:1990 o - EN 55104 / 5.1995 Category: o - EN 55015 / A1:1990 o - EN 55015 / 12.1993 o - EN 55022 / 5.1995 o - class A o - class B o - prEN 55103-1 / 3.1995 o - prEN 50121-3-2 / 3.1995 o - EN 60601-1-2 / 4.1994 o - VCCI o - class 1 o - class 2 o - Part 15 Subpart C (15.209) Β„ - Part 15 Subpart C (15.231) FCC ID: RTD-G6R File No. T 24275-02-03 XF , Page 4 of 14 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 A D D R E S S O F T H E T E S T L A B O R A T O R Y - MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 D - 94342 Strasskirchen E N V I R O N M E N T A L C O N D I T I O N S Temperature: 15-35 Β° C ____________ Humidity 45-60 % ____________ Atmospheric pressure 860-1060 mbar ____________ POWER SUPPLY SYSTEM UTILIZED Power supply system Transmitter: Β„ 9,0 V DC STATEMENT OF MEASUREMENT UNCERTAINTY SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EuT) The EuT is a transmitter for electronic remote ignition and control system. It is designed for gas appliances with pilot burners including ODS. Number of received/tested samples: 2 / 2 Serial Number: G6R DEFINITIONS FOR SYMBOLS USED IN THIS TEST REPORT Β„ The black square indicates that the listed condition, standard or equipment is applicable for this report. o Blank box indicates that the listed condition, standard or equipment was not applicable for this report. FCC ID: RTD-G6R File No. T 24275-02-03 XF , Page 5 of 14 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 M E A S U R E M E N T P R O T O C O L F O R F C C , V C C I A N D A U S T E L Test Methodology Conducted and radiated emission testing is performed according to the procedures in International Special Committee on Radio Interference (CISPR) Publication 22 (1993), European Standard EN 55022 and Australian Standard AS 3548 (which are based on CISPR 22). The Japanese standard, "Voluntary Control Council for Interference (VCCI) by Data Processing Equipment and Electronic Office Machines, Technical Requirements" is technically equivalent to CISPR 22 (1993). For official compliance, a conformance report must be sent to and accepted by the VCCI. In compliance with FCC Docket 92-152, "Harmonization of Rules for Digital Devices Incorporate International Standards", testing for FCC compliance may be done following the ANSI C63.4-1992 procedures and using the FCC limits or the CISPR 22 Limits. Measurement Uncertainty The test system for conducted emissions is defined as the LISN, tuned receiver or spectrum analyzer, and coaxial cable. The test system for radiated emissions is defined as the antenna, the pre-amplifier, the spectrum analyzer and the coaxial cable. These test systems have a measurement uncertainty of Β±4.5 dB. The equipment comprising the test systems are calibrated on an annual basis. Justification The Equipment Under Test (EuT) is configured in a typical user arrangement in accordance with the manufacturer's instructions. A cable is connected to each available port and either terminated with a peripher…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: RTD-G6R Attachment C: Photos of the test setup File No. T 24275-02-03 XF , Page C 1 of C 5 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 SPURIOUS EMISSIONS (electric field) 30 MHz - 1000 MHz (front view) FCC ID: RTD-G6R Attachment C: Photos of the test setup File No. T 24275-02-03 XF , Page C 2 of C 5 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 SPURIOUS EMISSIONS (electric field) 30 MHz - 1000 MHz (rear view) FCC ID: RTD-G6R Attachment C: Photos of the test setup File No. T 24275-02-03 XF , Page C 3 of C 5 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 SPURIOUS EMISSIONS (electric field) 30 MHz - 1000 MHz (side view) FCC ID: RTD-G6R Attachment C: Photos of the test setup File No. T 24275-02-03 XF , Page C 4 of C 5 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 SPURIOUS EMISSIONS (electric field) 1000MHz – 10-harmonics (front view) FCC ID: RTD-G6R Attachment C: Photos of the test setup File No. T 24275-02-03 XF , Page C 5 of C 5 MIKES BABT PRODUCT SERVICE GmbH Ohmstrasse 2-4 94342 Strasskirchen Tel.:+9424-9407-0 Fax:+9424-9407-60 Rev. No. 9.3 SPURIOUS EMISSIONS (electric field) 1000MHz – 10-harmonics (rear view)

Contact Information

Applicant

Barbara Happe(Group Leader Development Gas Controls)
[email protected]49 3947 400 335Fax: 49 3947 400 200

Test Firm

MIKES BABT Product Service GmbHHarald Buchwald
[email protected]49-9424-9481-150Fax: 49-9424-9481-240

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231315 MHz - 315 MHz-
Confidentiality
Long Term

Other Applications from Mertik Maxitrol GmbH & Co. KG

Handset of remote electronic ignition and control system for gas applications - FCC ID RTD-G6RH - Mertik Maxitrol GmbH & Co. KG
RTD-G6RH

Handset of remote electronic ignition and control system for gas applications

Feb 12, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Handset of remote electronic ignition and control system for gas applications - FCC ID RTD-B6R - Mertik Maxitrol GmbH & Co. KG
RTD-B6R

Handset of remote electronic ignition and control system for gas applications

Mar 04, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
e-Flame - FCC ID RTD-G6RT - Mertik Maxitrol GmbH & Co. KG
RTD-G6RT

e-Flame

May 10, 2004

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter