Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Automatic Arm Type Blood Pressure Monitor KP-7590 I N S T R U C T I O N M A N U A L Manufacturer: K-Jump Health Co., Ltd. No. 56, Wu Kung 5th Rd. , New Taipei Industrial Park, New Taipei City 24890, Taiwan www.kjump.com EU Authorized Representative: Polygreen Germany GmbH Ruhlsdorfer Straβe 95, D-14532, Stahnsdorf, Germany Precautions for Use..................................................1 Product Description and Intended Use.....................2 About Blood Pressure...............................................2 Device and Display Overview....................................5 Explanation of Symbols............................................6 Preparation for Use Battery Installation................................................7 Setting the Clock...................................................8 Attaching the Cuff and Measuring Posture...........8 Taking a Measurement.............................................9 Operating with Smartphone/teblet........................10 Memory Function....................................................10 Care and Maintenance.............................................11 Clean / DisinfectionProduct....................................12 Trouble shooting..................................................12 Product Specifications ...........................................13 Warranty Information ..............................................15 Ta b l e o f C o n t e n t s 1 P r e c a u t i o n s f o r U s e ※WARNINGS: 1. The device is not intended for neonatal use. 2. Consult your physician for health status and blood pressure range before taking measurement at home with this device. 3. Always consult your physician for interpretation of blood pressure measurements and follow their directions. 4. The performance of this device can be influenced as severe arrhythmias such as atrial or ventricular premature beats or atrial fibrillation are presented during measurement. 5. If the cuff causes any discomfort during measurement, press the POWER button to turn off the device immediately. 6. Avoid prolonged over-inflation of the bladder to prevent harmful physical injury. 7. Pull off the Velcro strap to detach the cuff if the cuff pressure exceeds 300mmHg without an automatic rapid exhaust. 8. The system might not meet its performance specifications if stored or used outside the temperature and humidity ranges specified in the product specification sheet. 9. Remove all batteries if the device is not likely to be used for a long period of time. 10. Do not modify this device or cuff without authorization of the manufacturer. 11. Keep blood pressure monitor (including cuff and batteries) away from children to avoid misusing. Children should not use the device without the supervision of an adult. 12. Only use the blood pressure monitor indoors and do not use it near such as microwave ovens. In the case of devices whose maximum power exceeds 2 W, the minimum distance from blood pressure monitor should be 3.3 meters. 13. Discard old battery carefully, out of reach of young children. Swallowing the battery may be fatal. If the battery or other small parts are swallowed, contact a hospital immediately to have it removed. 14. Any known restrictions on use or contra-indication(s): Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. 2 P r e c a u t i o n s f o r U s e ※CAUTIONS: 1. Read and follow the entire instruction manual before operating blood pressure monitor. 2. Do not press the POWER button if the cuff has not been properly wrapped. 3. Do not press the POWER button on blood pressure monitor if the cuff has not been properly wrapped. 4. The malfunctions of display can be determined by pressing and holding the POWER button under power-off mode. 5. Dispose of the device and batteries according applicable local regulations for environmental protection. 6. The accuracy of the blood pressure monitor is recommended to be verified every two years. Contact authorized agent or laboratory for inspection/calibration service. 7. For Bluetooth / NFC, please make sure Smartphone / Tablet have Bluetooth / NFC function available and enable Bluetooth / NFC before operating from Smartphone / Tablet. D e v i c e D e s c r i p t i o n a n d I n t e n d e d U s e The blood pressure monitor is an electronic device intended to make human blood pressure and pulse rate at upper arm of adult population utilizing non-invasive oscillometric method. In household environment. If the device model has connection function with Smartphone / Tablet, User also can upload data to Smartphone/Tablet for reviewing by graph, sharing by E-mail, etc. A b o u t B l o o d P r e s s u r e ● What is blood pressure? Blood pressure is produced by the force of blood flowing against artery walls after the heart ejects blood into vessel system. ● What are systolic and diastolic pressures? Systolic pressure represents the highest pressure during heart contraction and diastolic pressure is the lowest pressure while heart is resting. 3 A b o u t B l o o d P r e s s u r e ● What is MOMI? MOMI (Measurement on Multiple Intelligence) is a new blood- pressure-measuring technology. MOMI, unlike the general technology which takes measurement during either cuff inflation or deflation, it takes measurements both during inflation and deflation then output a weighted value. ● WHO-ISH classification Your blood pressure measurement can be compared with classification categories defined by 1999 World Health Organization – International Society of Hypertension Guidelines for Management of Hypertension for preliminary evaluation. Please consult your physician for interpretation of blood pressure measurement and follow their directions. ● What about low blood pressure? In general, lower blood pressure reading is better unless it causes some uncomfortable symptoms such as fa…
Text truncated - open the document above for the full version.
Appendix P Photo Documentation Page 1 of 3 10050598 001; 10050599 001 Product: Bluetooth module for medical device Type Identification: KP-7590 Appendix P Photo Documentation Page 2 of 3 10050598 001; 10050599 001 Product: Bluetooth module for medical device Type Identification: KP-7590 Appendix P Photo Documentation Page 3 of 3 10050598 001; 10050599 001 Product: Bluetooth module for medical device Type Identification: KP-7590
Label here
Appendix P Photo Documentation Page 1 of 2 10050598 001; 10050599 001 Product: Bluetooth module for medical device Type Identification: KP-7590 Appendix P Photo Documentation Page 2 of 2 10050598 001; 10050599 001 Product: Bluetooth module for medical device Type Identification: KP-7590
Produkte Products Prüfbericht - Nr.: Test Report No. 10050599 001 Seite 30 von 34 Page 30 of 34 6. Safety Human exposure 6.1 Radio Frequency Exposure Compliance 6.1.1 Electromagnetic Fields RESULT: Passed Test standard : FCC KDB Publication 447498 D01 v05 The maximum peak output power of the transmitter is 3.3473 mW. Hence the EUT is excluded from SAR evaluation. Please also refer to FCC KDB publication 447498 D01 v05: Mobile Portable RF Exposure
Produkte Products Prüfbericht - Nr.: Test Report No. 10050599 001 Seite 2 von 34 Page 2 of 34 TEST SUMMARY 5.1.1 ANTENNA REQUIREMENT RESULT: Passed 5.1.2 PEAK OUTPUT POWER RESULT: Passed 5.1.3 6DB BANDWIDTH RESULT: Passed 5.1.4 POWER DENSITY RESULT: Passed 5.1.5 CONDUCTED SPURIOUS EMISSIONS AND FREQUENCY BAND EDGE MEASURED IN 100KHZ BANDWIDTH RESULT: Passed 5.1.6 SPURIOUS EMISSION RESULT: Passed 6.1.1 ELECTROMAGNETIC FIELDS RESULT: Passed Produkte Products Prüfbericht - Nr.: Test Report No. 10050599 001 Seite 3 von 34 Page 3 of 34 Contents 1. GENERAL REMARKS ............................................................................................... 4 1.1 COMPLEMENTARY MATERIALS ................................................................................. 4 2. TEST SITES ............................................................................................................ 5 2.1 TEST FACILITIES ..................................................................................................... 5 2.2 LIST OF TEST AND MEASUREMENT INSTRUMENTS ...................................................... 6 2.3 TRACEABILITY ........................................................................................................ 7 2.4 CALIBRATION ......................................................................................................... 7 2.5 MEASUREMENT UNCERTAINTY ................................................................................. 7 3. GENERAL PRODUCT INFORMATION ........................................................................... 8 3.1 PRODUCT FUNCTION AND INTENDED USE ................................................................. 8 3.2 SYSTEM DETAILS AND RATINGS ............................................................................... 8 3.3 INDEPENDENT OPERATION MODES ........................................................................... 9 3.4 NOISE GENERATING AND NOISE SUPPRESSING PARTS .............................................. 9 3.5 SUBMITTED DOCUMENTS ......................................................................................... 9 4. TEST SET-UP AND OPERATION MODES ................................................................... 10 4.1 PRINCIPLE OF CONFIGURATION SELECTION ............................................................ 10 4.2 TEST OPERATION AND TEST SOFTWARE................................................................. 10 4.3 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ............................................... 10 4.4 COUNTERMEASURES TO ACHIEVE EMC COMPLIANCE .............................................. 11 4.5 TEST SETUP DIAGRAM .......................................................................................... 11 5. TEST RESULTS ..................................................................................................... 13 5.1 TRANSMITTER REQUIREMENT & TEST SUITES ......................................................... 13 5.1.1 Antenna Requirement ................................................................................................................ 13 5.1.2 Peak Output Power .................................................................................................................... 14 5.1.3 6dB Bandwidth ........................................................................................................................... 17 5.1.4 Power Density ............................................................................................................................ 22 5.1.5 Conducted spurious emissions and Frequency Band Edge measured in 100kHz Bandwidth ................................................................................................................................... 25 5.1.6 Spurious Emission ..................................................................................................................... 29 6. SAFETY HUMAN EXPOSURE ................................................................................... 30 6.1 RADIO FREQUENCY EXPOSURE COMPLIANCE ......................................................... 30 6.1.1 Electromagnetic Fields ............................................................................................................... 30 7. PHOTOGRAPHS OF THE TEST SET-UP ..................................................................... 31 Produkte Products Prüfbericht - Nr.: Test Report No. 10050599 001 Seite 4 von 34 Page 4 of 34 8. LIST OF TABLES ................................................................................................... 34 9. LIST OF PHOTOGRAPHS......................................................................................... 34 1. General Remarks 1.1 Complementary Materials All attachments are integral parts of this test report. This applies especially to the following appendix: Appendix P: Photo Documentation internal view (File Name: 10050599APPENDIX P) Appendix D: Test Result of Radiated Emissions (File Name: 10050599APPENDIX D) Test Specifications The following standards were applied. Table 1: Applied Standard and Test Levels Radio NCC Low-power Radio-frequency Devices Technical Regulations LP0002(2011)(100年6月28日) FCC CFR47 Part 15: Subpart C Section 15.247 RSS-210 Issue 8, December 2010 RSS-Gen, Issue 4, November 2014 ANSI C63.4:2009, ANSI C63.10:2009, ANSI C63.10:2013 KDB558074 D01 DTS Meas Guidance v02 Produkte Products Prüfbericht - Nr.: Test Report No. 10050599 001 Seite 5 von 34 Page 5 of 34 2. Test Sites 2.1 Test Facilities TUV Rheinland Taiwan Ltd. 11F. No.758, Sec. 4, Bade Rd., Songshan Dist. Taipei City 105 Taiwan (R.O.C.) FCC Registration No.: 365730 IC Canada Registration No.: 9465A-1 TAF Accredited NCC Test Lab. No.:0759 TAF ISO17025 Certification effective periods: 2013-Jul-1st to 2016-Jun-30th Produkte Products Prüfbericht - Nr.: Test Report No. 10050599 001 Seite 6 von 34 Page 6 of 34 2.2 List of Test and Measurement Instruments Table 2: List of Test …
Text truncated - open the document above for the full version.
Test Report No.10050599 001 Appendix D: Radiated Spurious Emission Data (File: 10050599AppendixD) Contents Spurious Emissions, Band Edges, 2.35-2.5G ................................................................................................. 2 Spurious Emissions, TX Mode, 1-18G ........................................................................................................... 6 Spurious Emissions, TX Mode, 18-26G ....................................................................................................... 12 Spurious Emissions, TX Mode, 30M-1G ..................................................................................................... 18 Spurious Emissions, Band Edge, 2.35-2.5G 2 Spurious Emissions, Band Edges, 2.35-2.5G Radiated Bandedge (GFSK) Low Channel (Hor) Spurious Emissions, Band Edge, 2.35-2.5G 3 Low Channel (Ver) Spurious Emissions, Band Edge, 2.35-2.5G 4 Radiated Bandedge (GFSK) High Channel (Hor) Spurious Emissions, Band Edge, 2.35-2.5G 5 High Channel (Ver) Spurious Emissions, TX Mode, 1-18G 6 Spurious Emissions, TX Mode, 1-18G Service No.: 114031999-FCC Test Distance: 3m Test Standard: FCC Above 1G PEAK Ant. Polarization: Horizontal Test item: Radiation Emission Test Time: 2015/4/2 14:13:50 Applicant: K-Jump Test Rating: DC 6V Product: Bluetooth module for medical device Temp.(°C °C°C °C)/Hum.(%): 22(°C °C°C °C)/58% Model No.: KB-0310 Test Engineer: Hugo Chang Test Mode: 2402-TX Remark: No. Frequency (MHz) Factor (dB/m) Reading (dBuV) Level (dBuV/m) Limit (dBuV/m) Margin (dB) Det. Height (cm) Azimuth (。 。。 。) Remark 1 4804.000 -2.79 47.17 44.38 74.00 -29.62 peak 0 2 5862.000 2.73 46.37 49.10 74.00 -24.90 peak 100 133 3 7206.000 5.44 43.53 48.97 74.00 -25.03 peak 0 Tel:+886-2172-7000 fax:+886-2528-0018 11F., No.758, Sec.4 Bade Road. Songshan Dist, Taipei City 105 TUV Taiwan Spurious Emissions, TX Mode, 1-18G 7 Service No.: 114031999-FCC Test Distance: 3m Test Standard: FCC Above 1G PEAK Ant. Polarization: Vertical Test item: Radiation Emission Test Time: 2015/4/2 14:14:53 Applicant: K-Jump Test Rating: DC 6V Product: Bluetooth module for medical device Temp.(°C °C°C °C)/Hum.(%): 22(°C °C°C °C)/58% Model No.: KB-0310 Test Engineer: Hugo Chang Test Mode: 2402-TX Remark: No. Frequency (MHz) Factor (dB/m) Reading (dBuV) Level (dBuV/m) Limit (dBuV/m) Margin (dB) Det. Height (cm) Azimuth (。 。。 。) Remark 1 4804.000 -2.79 48.70 45.91 74.00 -28.09 peak 2 6406.000 5.10 44.47 49.57 74.00 -24.43 peak 100 69 3 7206.000 5.44 43.05 48.49 74.00 -25.51 peak Tel:+886-2172-7000 fax:+886-2528-0018 11F., No.758, Sec.4 Bade Road. Songshan Dist, Taipei City 105 TUV Taiwan Spurious Emissions, TX Mode, 1-18G 8 Service No.: 114031999-FCC Test Distance: 3m Test Standard: FCC Above 1G PEAK Ant. Polarization: Horizontal Test item: Radiation Emission Test Time: 2015/4/2 14:17:33 Applicant: K-Jump Test Rating: DC 6V Product: Bluetooth module for medical device Temp.(°C °C°C °C)/Hum.(%): 22(°C °C°C °C)/58% Model No.: KB-0310 Test Engineer: Hugo Chang Test Mode: 2440-TX Remark: No. Frequency (MHz) Factor (dB/m) Reading (dBuV) Level (dBuV/m) Limit (dBuV/m) Margin (dB) Det. Height (cm) Azimuth (。 。。 。) Remark 1 4880.000 -2.58 47.74 45.16 74.00 -28.84 peak 2 5947.000 3.32 45.77 49.09 74.00 -24.91 peak 100 95 3 7320.000 5.75 42.43 48.18 74.00 -25.82 peak Tel:+886-2172-7000 fax:+886-2528-0018 11F., No.758, Sec.4 Bade Road. Songshan Dist, Taipei City 105 TUV Taiwan Spurious Emissions, TX Mode, 1-18G 9 Service No.: 114031999-FCC Test Distance: 3m Test Standard: FCC Above 1G PEAK Ant. Polarization: Vertical Test item: Radiation Emission Test Time: 2015/4/2 14:18:36 Applicant: K-Jump Test Rating: DC 6V Product: Bluetooth module for medical device Temp.(°C °C°C °C)/Hum.(%): 22(°C °C°C °C)/58% Model No.: KB-0310 Test Engineer: Hugo Chang Test Mode: 2440-TX Remark: No. Frequency (MHz) Factor (dB/m) Reading (dBuV) Level (dBuV/m) Limit (dBuV/m) Margin (dB) Det. Height (cm) Azimuth (。 。。 。) Remark 1 4880.000 -2.58 47.76 45.18 74.00 -28.82 peak 2 6168.000 4.26 44.60 48.86 74.00 -25.14 peak 100 287 3 7320.000 5.75 42.10 47.85 74.00 -26.15 peak Tel:+886-2172-7000 fax:+886-2528-0018 11F., No.758, Sec.4 Bade Road. Songshan Dist, Taipei City 105 TUV Taiwan Spurious Emissions, TX Mode, 1-18G 10 Service No.: 114031999-FCC Test Distance: 3m Test Standard: FCC Above 1G PEAK Ant. Polarization: Horizontal Test item: Radiation Emission Test Time: 2015/4/2 14:20:36 Applicant: K-Jump Test Rating: DC 6V Product: Bluetooth module for medical device Temp.(°C °C°C °C)/Hum.(%): 22(°C °C°C °C)/58% Model No.: KB-0310 Test Engineer: Hugo Chang Test Mode: 2480-TX Remark: No. Frequency (MHz) Factor (dB/m) Reading (dBuV) Level (dBuV/m) Limit (dBuV/m) Margin (dB) Det. Height (cm) Azimuth (。 。。 。) Remark 1 4960.000 -2.37 47.34 44.97 74.00 -29.03 peak 2 6389.000 5.05 44.38 49.43 74.00 -24.57 peak 100 145 3 7440.000 6.08 42.82 48.90 74.00 -25.10 peak Tel:+886-2172-7000 fax:+886-2528-0018 11F., No.758, Sec.4 Bade Road. Songshan Dist, Taipei City 105 TUV Taiwan Spurious Emissions, TX Mode, 1-18G 11 Service No.: 114031999-FCC Test Distance: 3m Test Standard: FCC Above 1G PEAK Ant. Polarization: Vertical Test item: Radiation Emission Test Time: 2015/4/2 14:21:39 Applicant: K-Jump Test Rating: DC 6V Product: Bluetooth module for medical device Temp.(°C °C°C °C)/Hum.(%): 22(°C °C°C °C)/58% Model No.: KB-0310 Test Engineer: Hugo Chang Test Mode: 2480-TX Remark: No. Frequency (MHz) Factor (dB/m) Reading (dBuV) Level (dBuV/m) Limit (dBuV/m) Margin (dB) Det. Height (cm) Azimuth (。 。。 。) Remark 1 4960.000 -2.37 47.17 44.80 74.00 -29.20 peak 2 6015.000 3.73 44.92 48.65 74.00 -25.35 peak 100 334 3 7440.000 6.08 42.77 48.85 74.00 -25.15 peak Tel:+886-2172-7000 fax:+886-2528-0018 11F., No.758, Sec.4 Bade Road. Songshan Dist, Taipei City 105 TUV Taiwan Spurious Emissions, TX Mode, 18-26G 12 Spurious Emissions, TX Mode, 18-26G Service No.: 114031999-FCC Test Distance: 3m Test Standard: FCC Above 1G PEAK Ant. Polarization: Horizontal Test…
Text truncated - open the document above for the full version.
Produkte Products Prüfbericht - Nr.: Test Report No. 10050599 001 Seite 31 von 34 Page 31 of 34 7. Photographs of the Test Set-Up Photograph 1: Set-up for Spurious Emissions (Front View) Produkte Products Prüfbericht - Nr.: Test Report No. 10050599 001 Seite 32 von 34 Page 32 of 34 Photograph 2: Set-up for Spurious Emissions (Back View 1) Photograph 3: Set-up for Spurious Emissions (Back View 2) Produkte Products Prüfbericht - Nr.: Test Report No. 10050599 001 Seite 33 von 34 Page 33 of 34 Photograph 4: Set-up for Conducted testing
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.30 mW |

Digital Thermometer
Equipment Class
DTS - Digital Transmission System
Clinic Patch Thermometer ( Temponitor )
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter