INSTRUCTIONS WIRELESS TRANSMITTER UWIT-Y0001-TX WIRELESS RECEIVER UWIT-Y0001-RX Labels and Symbols1 Important Information — Please Read Before Use4 Chapter 1 Checking the Package Contents11 Chapter 2 Nomenclature and Functions15 Chapter 3 Installation and Connection21 Chapter 4 Inspection31 Chapter 5 Operation35 Chapter 6 Care, Storage, and Disposal37 Chapter 7 Troubleshooting39 Appendix43 USA: CAUTION:Federal law restricts this device to sale by or on the order of a physician. OPERATION MANUAL Contents i UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL Contents Labels and Symbols .......................................................................................................... 1 Important Information — Please Read Before Use ......................................................... 4 Intended use .......................................................................................................................... 4 Instruction manual ................................................................................................................. 4 User qualifications ................................................................................................................. 5 Instrument compatibility ......................................................................................................... 5 Repair and modification ......................................................................................................... 5 Signal words .......................................................................................................................... 6 Dangers, warnings, and cautions .......................................................................................... 6 EMC (Electromagnetic Compatibility) .............................................................................. 8 Summary of Equipment Functions .................................................................................. 9 Transmitting function of HDTV video signal over radio frequency channel ........................... 9 Pair changing function ........................................................................................................... 9 Chapter 1 Checking the Package Contents ....................................... 11 1.1Checking the package contents ............................................................................ 11 Chapter 2 Nomenclature and Functions ............................................ 15 2.1Symbols and descriptions ..................................................................................... 15 2.2Front panel of Wireless Transmitter ..................................................................... 16 2.3Rear panel of Wireless Transmitter ...................................................................... 17 2.4Front panel of Wireless Receiver .......................................................................... 18 2.5Rear panel of Wireless Receiver ........................................................................... 18 2.6AC adapter .............................................................................................................. 19 Chapter 3 Installation and Connection ............................................... 21 3.1Precautions for installation and connection ........................................................ 21 3.2Installation of the equipment ................................................................................. 22 3.3Installation of the AC adaptor ............................................................................... 24 Installation on the Attachment for UWIT (MAJ-Y0149) ........................................................ 24 3.4Connecting AC adaptor to Wireless Transmitter or Receiver ............................ 25 3.5Connecting AC adaptor to an AC mains power supply ...................................... 26 When using the power cord of mobile workstation (WM-NP1, WM-WP1, WM-DP1) .......... 26 When using the supplied AC cord ....................................................................................... 26 3.6Connecting video cables to Wireless Transmitter .............................................. 27 Selection of video input terminal .......................................................................................... 27 Connection diagram (When using HD-SDI) ......................................................................... 28 Connection diagram (When using DVI) ............................................................................... 29 ii Contents UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL 3.7Connecting video cables to Wireless Receiver ................................................... 30 Connection diagram ............................................................................................................ 30 Chapter 4 Inspection ............................................................................ 31 4.1Inspection of the power supply ............................................................................. 31 4.2Inspection of the displayed image ........................................................................ 32 Chapter 5 Operation ............................................................................. 35 5.1Turn the Wireless Transmitter and Receiver ON ................................................. 35 When the mobile workstation (WM-NP1, WM-WP1, WM-DP1) is used .............................. 35 When the mobile workstation (WM-NP1, WM-WP1, WM-DP1) is not used ........................ 35 5.2Connection of the Wireless Transmitter and Receiver ....................................... 36 Chapter 6 Care, Storage, and Disposal .............................................. 37 6.1Care .......................................................................................................................... 37 6.2Storage ................................................................…
Text truncated - open the document above for the full version.
3 2011/8/23 No data copy / No data transfer permitted External Photos TOPFront Left Side Right Side Rear Bottom OLYMPUS MEDICAL SYSTEMS CORP.Model : UWIT-Y0001-TXFCC ID : S8Q-RU5796IC : 4763B-RU5796
AC Adapter AC Adapter
5 2011/8/29 No data copy / No data transfer permitted Label Position Label OLYMPUS MEDICAL SYSTEMS CORP.Model : UWIT-Y0001-TXFCC ID : S8Q-RU5796IC : 4763B-RU5796 6 2011/8/29 No data copy / No data transfer permitted Label OLYMPUS MEDICAL SYSTEMS CORP.Model : UWIT-Y0001-TXFCC ID : S8Q-RU5796IC : 4763B-RU5796 :UWIT-Y0001-TX
4 2011/8/23 No data copy / No data transfer permitted Internal Photos FrontBack OLYMPUS MEDICAL SYSTEMS CORP.Model : UWIT-Y0001-TXFCC ID : S8Q-RU5796IC : 4763B-RU5796 Antenna
Test report No. : 31JE0273-HO-01-A-R1 Page : 2 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Customer information ......................................................................................................... 3 SECTION 2: Equipment under test (E.U.T.) ........................................................................................... 3 SECTION 3: Test specification, procedures & results ............................................................................ 5 SECTION 4: Operation of E.U.T. during testing .................................................................................... 9 SECTION 5: Conducted Emission .......................................................................................................... 11 SECTION 6: Radiated Emission (Spurious Emission, Power Density) ............................................... 12 SECTION 7: Frequency Stability ........................................................................................................... 14 APPENDIX 1: Photographs of test setup ............................................................................................... 15 Conducted Emission ......................................................................................................................... 15 Spurious Emission............................................................................................................................. 16 Carrier Frequency Measurement ....................................................................................................... 17 Frequency Stability ........................................................................................................................... 18 APPENDIX 2: Data of EMI test .............................................................................................................. 21 Conducted Emission ......................................................................................................................... 21 6dB Bandwidth ................................................................................................................................. 23 26dB and 99% Bandwidth ................................................................................................................ 26 Power Density ................................................................................................................................... 29 Peak Output Power............................................................................................................................ 32 Spurious Emission............................................................................................................................. 33 Receiver Spurious Emission ............................................................................................................. 36 Frequency Stability ........................................................................................................................... 37 Group Instllation ............................................................................................................................... 38 Transmitter Identification ................................................................................................................. 38 APPENDIX 3: RF Exposure .................................................................................................................... 39 APPENDIX 4: Test instruments ............................................................................................................. 42 Test report No. : 31JE0273-HO-01-A-R1 Page : 3 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 SECTION 1: Customer information Company Name : Olympus Medical Systems Corp. Address : 2951 Ishikawa-cho, Hachiouji-shi, Tokyo, 192-8507 Japan Telephone Number : +81-42-642-2632 Facsimile Number : +81-42-642-2032 Contact Person : Hideki Tashiro SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : WIRELESS TRANSMITTER Model No. : UWIT-Y0001-TX Serial No. : Refer to Section 4, Clause 4.2 Rating : DC12V via AC adapter (OLP-K027-M) AC adapter : AC100-240V input Receipt Date of Sample : July 23, 2011 Country of Mass-production : Japan Condition of EUT : Engineering prototype (Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab Test report No. : 31JE0273-HO-01-A-R1 Page : 4 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 2.2 Product Description HDTV video signal (1920 x 1080 60p max. when using DVI) was transmitted over radio frequency channel with no compression and low latency between a pair of Wireless Transmitter and Receiver. By operating SELECT button of the Wireless Transmitter and Receiver, the pair of Transmitter and Receiver can be set manually. General Specification Clock frequency(ies) in the system : OSC: 54MHz, BB IC: 317MHz, CPU: 100MHz Radio Specification Radio Type : Transceiver Frequency of Operation : LRP: 60.321375GHz, 60.480000GHz, 60.638625GHz, 62.481375GHz, 62.640000GHz, 62.798625GHz HRP: 60.48GHz, 62.64GHz Modulation : LRP: OFDM, BPSK HRP: OFDM, QPSK, 16-QAM Medium access protocol : The RF chip manufactured by Silicon Image, Inc. is mounted on the EUT. The MAC is no modification by the Olympus Medical Systems Corp. Antenna Type : Internal Antenna (embedded into th…
Text truncated - open the document above for the full version.
Test report No. : 31JE0273-HO-01-A-R1 Page : 21 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 2: Data of EMI test Conducted Emission DATA OF CONDUCTED EMISSION TEST UL Japan, Inc. Head Office EMC Lab. No.4 Semi Anechoic Chamber Date : 2011/08/04 Company : Olympus Medical Systems Corp. Report No. : 31JE0273-HO-01 Kind of EUT : WIRELESS TRANSMITTER Power : AC 120V / 60Hz Model No. : UWIT-Y0001-TX Temp./Humi. : 24deg. C / 55% RH Serial No. : 0000004 Engineer : Hironobu Ohnishi Mode / Remarks : Tx HRP Lch 60.480GHz LIMIT : FCC15.207 QP FCC15.207 AV CHART:WITH FACTOR,Peak hold data. CALCULATION:RESULT[dBuV]=READING[dBuV]+C.F[dB](LISN LOSS+CABLE LOSS) Except for the above table : adequate margin data below the limits. Frequency[Hz] [dBuV]<< QP/AV DATA >> L:QP:AV N:QP:AV .15M30M.2M.3M.5M.7M1M2M3M5M7M10M20M 0 10 20 30 40 50 60 70 80 Frequency Reading LevelReading LevelCorr.ResultsResultsLimitLimitMarginMargin PhaseComment Frequency QPAVFactorQPAVQPAVQPAVPhaseComment [MHz][dBuV][dBuV][dB][dBuV][dBuV][dBuV][dBuV][dB][dB] PhaseComment 0.1500025.73.213.339.016.566.056.027.039.5N 0.1748137.313.613.350.626.964.754.714.127.8N 0.2066036.020.113.349.333.463.353.314.019.9N 0.2339229.37.113.342.620.462.352.319.731.9N 3.8198023.910.713.637.524.356.046.018.521.7N 13.2680025.018.814.339.333.160.050.020.716.9N 0.1500026.94.413.340.217.766.056.025.838.3L 0.1758338.214.813.351.528.164.754.713.226.6L 0.1980036.520.313.349.833.663.753.713.920.1L 0.2335029.37.613.342.620.962.352.319.731.4L 3.4626023.711.313.637.324.956.046.018.721.1L 13.0020023.817.914.338.132.260.050.021.917.8L HRP Tx 60.48GHz Test report No. : 31JE0273-HO-01-A-R1 Page : 22 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Conducted Emission Test place Head Office EMC Lab. No.4 Semi Anechoic Chamber Report No. 31JE0273-HO-01 Date 08/04/2011 Temperature/ Humidity 24 deg. C / 55% RH Engineer Hironobu Ohnishi Mode HRP Tx 60.48GHz 62.64GHz Y scale [dBuV] Chart N L Test report No. : 31JE0273-HO-01-A-R1 Page : 23 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 6dB Bandwidth Test place Head Office EMC Lab. No.4 Semi Anechoic Chamber Report No. 31JE0273-HO-01 Date 08/01/2011 Temperature/ Humidity 25 deg. C / 75% RH Engineer Hironobu Ohnishi Mode Tx ModeChannelFrequency6dB Bandwidth [GHz][MHz] LRPLow60.32137590.347 Mid60.48000091.128 High60.63862591.407 HRP260.4800001731.000 LRPLow62.48137590.810 Mid62.64000090.874 High62.79862590.726 HRP362.6400001750.000 Test report No. : 31JE0273-HO-01-A-R1 Page : 24 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 6dB Bandwidth [HRP] 60.48GHz 62.64GHz Test report No. : 31JE0273-HO-01-A-R1 Page : 25 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 6dB Bandwidth [LRP] 60.321375GHz 62.481375GHz 60.480000GHz 62.640000GHz 60.638625GHz 62.798625GHz Test report No. : 31JE0273-HO-01-A-R1 Page : 26 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 26dB and 99% Bandwidth Test place Head Office EMC Lab. No.4 Semi Anechoic Chamber Report No. 31JE0273-HO-01 Date 08/01/2011 Temperature/ Humidity 25 deg. C / 75% RH Engineer Hironobu Ohnishi Mode Tx ModeRateChannelFrequency26dB Bandwidth99% Bandwidth [GHz][MHz][MHz] LRP-Low60.321375393.755305.236 Mid60.480000397.102299.558 High60.638625399.730301.745 HRPQuarter3489.0002192.600 Half3625.0002176.300 Full2930.0001808.300 LRP-Low62.481375399.413287.298 Mid62.640000384.673287.130 High62.798625392.538287.635 HRPQuarter3447.0002280.900 Half3446.0002289.300 Full2765.0002094.800 260.480000 362.640000 Test report No. : 31JE0273-HO-01-A-R1 Page : 27 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 26dB and 99% Bandwidth [HRP] 60.48GHz 62.64GHz Quarter rate (QPSK, 0.952Gb/s) Half rate (QPSK, 1.904Gb/s) Full rate (16-QAM, 3.807Gb/s) Test report No. : 31JE0273-HO-01-A-R1 Page : 28 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 26dB and 99% Bandwidth [LRP] 60.321375GHz 62.481375GHz 60.480000GHz 62.640000GHz 60.638625GHz 62.798625GHz Test report No. : 31JE0273-HO-01-A-R1 Page : 29 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Power Density Test place Head Office EMC Lab. No.4 Semi Anechoic Chamber Report No. 31JE0273-HO-01 Date 08/01/2011 Temperature/ Humidity 25 deg. C / 75% RH Engineer Hironobu Ohnishi Mode Tx [Peak result] ModeChannelFrequency Measurement Measured Rx Antenna SystemLNAFree fieldSpecificationPower DistancePowerGainLossGainAttenuationD…
Text truncated - open the document above for the full version.
Test report No. : 31JE0273-HO-01-A-R1 Page : 15 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 1: Photographs of test setup Conducted Emission Photo 1 Photo 2 Test report No. : 31JE0273-HO-01-A-R1 Page : 16 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Spurious Emission Photo 1 Photo 2 Test report No. : 31JE0273-HO-01-A-R1 Page : 17 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Carrier Frequency Measurement Photo 1 Photo 2 Test report No. : 31JE0273-HO-01-A-R1 Page : 18 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Frequency Stability Photo Test report No. : 31JE0273-HO-01-A-R1 Page : 19 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 4.2 Configuration and peripherals [Conducted Emission] : Standard Ferrite Core C A E D 4 5 6 3 1 B 2 AC 120V/60Hz AC 120V/60Hz 11 Terminator [Radiated Emission] : Standard Ferrite Core C A F H E D 4 5 6 3 1 B G 2 7 8 9 10 AC 120V/60Hz AC 120V/60Hz AC 120V/60Hz AC 120V/60Hz 11 Terminator * Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions. Test report No. : 31JE0273-HO-01-A-R1 Page : 20 of 43 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5796 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Description of EUT No. Item Model number Serial number Manufacturer Remarks A WIRELESS TRANSMITTER UWIT-Y0001-TX 0000004 Olympus Medical Systems Corp. EUT B AC ADAPTER OLP-K027-M R/D1 117037 Olympus Medical Systems Corp. EUT C Personal Computer WF988AV JPA1040N5X hp - D Mouse M-UAL-96 FASTR0C5BZNEWL hp - E Keyboard KU-0316 BAUJD01VBZO1DJ hp - F WIRELESS RECEIVER UWIT-Y0001-RX 0000004 Olympus Medical Systems Corp. - G AC ADAPTER OLP-K027-M R/D1 117038 Olympus Medical Systems Corp. - H LCD RDT231WLM 01235909AJ MITSUBISHI - List of cables used No. Name Length (m) Shield Remarks Cable Connector 1 DC Cable 2.90 Unshielded Unshielded - 2 AC Cable 2.90 Unshielded Unshielded - 3 DVI-D Cable 3.00 Shielded Shielded - 4 AC Cable 1.90 Unshielded Unshielded - 5 USB Cable 1.75 Shielded Shielded - 6 USB CABLE 1.75 Shielded Shielded - 7 DC Cable 2.90 Unshielded Unshielded - 8 AC Cable 2.90 Unshielded Unshielded - 9 DVI-D Cable 3.00 Shielded Shielded - 10 AC Cable 2.90 Unshielded Unshielded - 11 75 Ohm coaxial Cable 1.00 Shielded Shielded -
4383-326 Asama-cho, Ise-shi · Mie-ken · Japan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 60.48 GHz - 62.64 GHz | 34.70 mW |

Low Power Transmitter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
WIRELESS RECEIVER
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Endoscope Position Detecting Unit
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Endoscope Reprocessor with RFID
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterLow Power Transmitter