FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Olympus Medical Systems Corp./
  3. S8Q-RU5808

S8Q-RU5808WIRELESS RECEIVER

Olympus Medical Systems Corp.
WIRELESS RECEIVER - FCC ID S8Q-RU5808 - Olympus Medical Systems Corp.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Sep 06, 2011
Application Purpose
Original Equipment
Date of Application
Sep 06, 2011
Equipment Note
WIRELESS RECEIVER
Frequency Range
60321.37500000 - 62798.62500000
Company
Olympus Medical Systems Corp.
Country
Japan

Documents & Files

Select a file to view

Users Manual

โ†—

Cover Letter(s)

โ†—
โ†—
โ†—

External Photos

โ†—
โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

Test Report

โ†—
โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

INSTRUCTIONS WIRELESS TRANSMITTER UWIT-Y0001-TX WIRELESS RECEIVER UWIT-Y0001-RX Labels and Symbols1 Important Information โ€” Please Read Before Use4 Chapter 1 Checking the Package Contents11 Chapter 2 Nomenclature and Functions15 Chapter 3 Installation and Connection21 Chapter 4 Inspection31 Chapter 5 Operation35 Chapter 6 Care, Storage, and Disposal37 Chapter 7 Troubleshooting39 Appendix43 USA: CAUTION:Federal law restricts this device to sale by or on the order of a physician. OPERATION MANUAL Contents i UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL Contents Labels and Symbols .......................................................................................................... 1 Important Information โ€” Please Read Before Use ......................................................... 4 Intended use .......................................................................................................................... 4 Instruction manual ................................................................................................................. 4 User qualifications ................................................................................................................. 5 Instrument compatibility ......................................................................................................... 5 Repair and modification ......................................................................................................... 5 Signal words .......................................................................................................................... 6 Dangers, warnings, and cautions .......................................................................................... 6 EMC (Electromagnetic Compatibility) .............................................................................. 8 Summary of Equipment Functions .................................................................................. 9 Transmitting function of HDTV video signal over radio frequency channel ........................... 9 Pair changing function ........................................................................................................... 9 Chapter 1 Checking the Package Contents ....................................... 11 1.1Checking the package contents ............................................................................ 11 Chapter 2 Nomenclature and Functions ............................................ 15 2.1Symbols and descriptions ..................................................................................... 15 2.2Front panel of Wireless Transmitter ..................................................................... 16 2.3Rear panel of Wireless Transmitter ...................................................................... 17 2.4Front panel of Wireless Receiver .......................................................................... 18 2.5Rear panel of Wireless Receiver ........................................................................... 18 2.6AC adapter .............................................................................................................. 19 Chapter 3 Installation and Connection ............................................... 21 3.1Precautions for installation and connection ........................................................ 21 3.2Installation of the equipment ................................................................................. 22 3.3Installation of the AC adaptor ............................................................................... 24 Installation on the Attachment for UWIT (MAJ-Y0149) ........................................................ 24 3.4Connecting AC adaptor to Wireless Transmitter or Receiver ............................ 25 3.5Connecting AC adaptor to an AC mains power supply ...................................... 26 When using the power cord of mobile workstation (WM-NP1, WM-WP1, WM-DP1) .......... 26 When using the supplied AC cord ....................................................................................... 26 3.6Connecting video cables to Wireless Transmitter .............................................. 27 Selection of video input terminal .......................................................................................... 27 Connection diagram (When using HD-SDI) ......................................................................... 28 Connection diagram (When using DVI) ............................................................................... 29 ii Contents UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL 3.7Connecting video cables to Wireless Receiver ................................................... 30 Connection diagram ............................................................................................................ 30 Chapter 4 Inspection ............................................................................ 31 4.1Inspection of the power supply ............................................................................. 31 4.2Inspection of the displayed image ........................................................................ 32 Chapter 5 Operation ............................................................................. 35 5.1Turn the Wireless Transmitter and Receiver ON ................................................. 35 When the mobile workstation (WM-NP1, WM-WP1, WM-DP1) is used .............................. 35 When the mobile workstation (WM-NP1, WM-WP1, WM-DP1) is not used ........................ 35 5.2Connection of the Wireless Transmitter and Receiver ....................................... 36 Chapter 6 Care, Storage, and Disposal .............................................. 37 6.1Care .......................................................................................................................... 37 6.2Storage ................................................................โ€ฆ

Text truncated - open the document above for the full version.

External Photos

3 2011/8/23 No data copy / No data transfer permitted External Photos TOPFront Left SideRight Side Rear Bottom OLYMPUS MEDICAL SYSTEMS CORP.Model : UWIT-Y0001-RXFCC ID : S8Q-RU5808IC : 4763B-RU5808

External Photos

AC Adapter AC Adapter

ID Label/Location Info

5 2011/8/29 No data copy / No data transfer permitted Label Position Label OLYMPUS MEDICAL SYSTEMS CORP.Model : UWIT-Y0001-RXFCC ID : S8Q-RU5808IC : 4763B-RU5808 6 2011/8/29 No data copy / No data transfer permitted Label OLYMPUS MEDICAL SYSTEMS CORP.Model : UWIT-Y0001-RXFCC ID : S8Q-RU5808IC : 4763B-RU5808 :UWIT-Y0001-RX

Internal Photos

4 2011/8/23 No data copy / No data transfer permitted Internal Photos FrontBack OLYMPUS MEDICAL SYSTEMS CORP.Model : UWIT-Y0001-RXFCC ID : S8Q-RU5808IC : 4763B-RU5808 Antenna

Test Report

Test report No. : 31JE0273-HO-01-B-R1 Page : 2 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Customer information ......................................................................................................... 3 SECTION 2: Equipment under test (E.U.T.) ........................................................................................... 3 SECTION 3: Test specification, procedures & results ............................................................................ 5 SECTION 4: Operation of E.U.T. during testing .................................................................................... 9 SECTION 5: Conducted Emission .......................................................................................................... 11 SECTION 6: Radiated Emission (Spurious Emission, Power Density) ............................................... 12 SECTION 7: Frequency Stability ........................................................................................................... 14 APPENDIX 1: Photographs of test setup ............................................................................................... 15 Conducted Emission ......................................................................................................................... 15 Spurious Emission............................................................................................................................. 16 Carrier Frequency Measurement ....................................................................................................... 17 Frequency Stability ........................................................................................................................... 18 APPENDIX 2: Data of EMI test .............................................................................................................. 21 Conducted Emission ......................................................................................................................... 21 6dB Bandwidth ................................................................................................................................. 23 26dB and 99% Bandwidth ................................................................................................................ 25 Power Density ................................................................................................................................... 27 Peak Output Power............................................................................................................................ 29 Spurious Emission............................................................................................................................. 30 Receiver Spurious Emission ............................................................................................................. 34 Frequency Stability ........................................................................................................................... 35 Group Instllation ............................................................................................................................... 36 Transmitter Identification ................................................................................................................. 36 APPENDIX 3: RF Exposure .................................................................................................................... 37 APPENDIX 4: Test instruments ............................................................................................................. 40 Test report No. : 31JE0273-HO-01-B-R1 Page : 3 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 SECTION 1: Customer information Company Name : Olympus Medical Systems Corp. Address : 2951 Ishikawa-cho, Hachiouji-shi, Tokyo, 192-8507 Japan Telephone Number : +81-42-642-2632 Facsimile Number : +81-42-642-2032 Contact Person : Hideki Tashiro SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : WIRELESS RECEIVER Model No. : UWIT-Y0001-RX Serial No. : Refer to Section 4, Clause 4.2 Rating : DC12V via AC adapter (OLP-K027-M) AC adapter : AC100-240V input Receipt Date of Sample : July 23, 2011 Country of Mass-production : Japan Condition of EUT : Engineering prototype (Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab Test report No. : 31JE0273-HO-01-B-R1 Page : 4 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 2.2 Product Description HDTV video signal (1920 x 1080 60p max. when using DVI) was transmitted over radio frequency channel with no compression and low latency between a pair of Wireless Transmitter and Receiver. By operating SELECT button of the Wireless Transmitter and Receiver, the pair of Transmitter and Receiver can be set manually. General Specification Clock frequency(ies) in the system : OSC: 54MHz, BB IC: 317MHz, CPU: 100MHz Radio Specification Radio Type : Transceiver Frequency of Operation : LRP: 60.321375GHz, 60.480000GHz, 60.638625GHz, 62.481375GHz, 62.640000GHz, 62.798625GHz Modulation : LRP: OFDM, BPSK Medium access protocol : The RF chip manufactured by Silicon Image, Inc. is mounted on the EUT. The MAC is no modification by the Olympus Medical Systems Corp. Antenna Type : Internal Antenna (embedded into the device package) Antenna Connector : None Antenna โ€ฆ

Text truncated - open the document above for the full version.

Test Report

Test report No. : 31JE0273-HO-01-B-R1 Page : 21 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 2: Data of EMI test Conducted Emission DATA OF CONDUCTED EMISSION TEST UL Japan, Inc. Head Office EMC Lab. No.4 Semi Anechoic Chamber Date : 2011/08/04 Company : Olympus Medical Systems Corp. Report No. : 31JE0273-HO-01 Kind of EUT : WIRELESS RECEIVER Power : AC 120V / 60Hz Model No. : UWIT-Y0001-RX Temp./Humi. : 24deg. C / 55% RH Serial No. : 0000004 Engineer : Hironobu Ohnishi Mode / Remarks : Tx LRP Lch 60.321375GHz LIMIT : FCC15.207 QP FCC15.207 AV CHART:WITH FACTOR,Peak hold data. CALCULATION:RESULT[dBuV]=READING[dBuV]+C.F[dB](LISN LOSS+CABLE LOSS) Except for the above table : adequate margin data below the limits. Frequency[Hz] [dBuV]<< QP/AV DATA >> L:QP:AV N:QP:AV .15M30M.2M.3M.5M.7M1M2M3M5M7M10M20M 0 10 20 30 40 50 60 70 80 Frequency Reading LevelReading LevelCorr.ResultsResultsLimitLimitMarginMargin PhaseComment Frequency QPAVFactorQPAVQPAVQPAVPhaseComment [MHz][dBuV][dBuV][dB][dBuV][dBuV][dBuV][dBuV][dB][dB] PhaseComment 0.1500022.50.913.335.814.266.056.030.241.8N 0.1737430.98.713.344.222.064.854.820.632.8N 0.1993030.216.413.343.529.763.653.620.123.9N 0.2333025.05.213.338.318.562.352.324.033.8N 3.3820020.37.813.633.921.456.046.022.124.6N 13.2844026.318.814.340.633.160.050.019.416.9N 0.1500021.70.613.335.013.966.056.031.042.1L 0.1835731.614.313.344.927.664.354.319.426.7L 0.2038030.217.313.343.530.663.553.520.022.9L 0.2363025.47.613.338.720.962.252.223.531.3L 3.4756023.69.913.637.223.556.046.018.822.5L 13.5180024.218.214.338.532.560.050.021.517.5L LRP Tx 60.321375GHz Test report No. : 31JE0273-HO-01-B-R1 Page : 22 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Conducted Emission Test place Head Office EMC Lab. No.4 Semi Anechoic Chamber Report No. 31JE0273-HO-01 Date 08/04/2011 Temperature/ Humidity 24 deg. C / 55% RH Engineer Hironobu Ohnishi Mode LRP Tx 60.321375GHz 62.481375GHz 62.798625GHz Y scale [dBuV] Chart N L Test report No. : 31JE0273-HO-01-B-R1 Page : 23 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 6dB Bandwidth Test place Head Office EMC Lab. No.4 Semi Anechoic Chamber Report No. 31JE0273-HO-01 Date 08/03/2011 Temperature/ Humidity 24 deg. C / 65% RH Engineer Hironobu Ohnishi Mode LRP Tx ModeChannelFrequency6dB Bandwidth [GHz][MHz] LRPLow60.32137590.629 Mid60.48000093.014 High60.63862590.585 LRPLow62.48137590.858 Mid62.64000090.091 High62.79862590.857 Test report No. : 31JE0273-HO-01-B-R1 Page : 24 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 6dB Bandwidth [LRP] 60.321375GHz 62.481375GHz 60.480000GHz 62.640000GHz 60.638625GHz 62.798625GHz Test report No. : 31JE0273-HO-01-B-R1 Page : 25 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 26dB and 99% Bandwidth Test place Head Office EMC Lab. No.4 Semi Anechoic Chamber Report No. 31JE0273-HO-01 Date 08/03/2011 Temperature/ Humidity 24 deg. C / 65% RH Engineer Hironobu Ohnishi Mode LRP Tx ModeChannelFrequency26dB Bandwidth99% Bandwidth [GHz][MHz][MHz] LRPLow60.321375283.588260.402 Mid60.480000269.597220.046 High60.638625299.279230.987 LRPLow62.481375322.667278.703 Mid62.640000281.882237.107 High62.798625323.510274.770 Test report No. : 31JE0273-HO-01-B-R1 Page : 26 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 26dB and 99% Bandwidth [LRP] 60.321375GHz 62.481375GHz 60.480000GHz 62.640000GHz 60.638625GHz 62.798625GHz Test report No. : 31JE0273-HO-01-B-R1 Page : 27 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Power Density Test place Head Office EMC Lab. No.4 Semi Anechoic Chamber Report No. 31JE0273-HO-01 Date 08/03/2011 Temperature/ Humidity 24 deg. C / 65% RH Engineer Hironobu Ohnishi Mode LRP Tx ModeChannelFrequency Measurement Measured Rx Antenna SystemLNAFree fieldSpecificationPower DistancePowerGainLossGainAttenuationDistanceDensityPkAv [GHz][m][dBm][dBi][dB][dB][dB][dBm] [mW][m] [uW/c m 2 ][uW/cm 2 ][uW/cm 2 ] LRPLow60.3213751.5-36.9724.2344.2527.1671.57 27.46557.23.00.493189 Mid60.4800001.5-36.2224.2544.3727.2771.60 28.22664.13.00.587189 High60.6386251.5-35.9424.2644.4927.3971.62 28.51710.23.00.628189 LRPLow62.4813751.5-40.0024.5045.0826.5071.88 25.96394.73.00.349189 Mid62.6400001.5-40.3324.5345.2726.4171.90 25.90389.23.00.344189 High62.7986251.5-40.4224.5645.4726.3371.92 26.08405.63.00.359189 Calculating formula: Free Field Attenuation = 10 * log((4 * pi * Measurement Distance / rambda) ^ 2) EIRP = Measured Power - Rx Antenna Gain + System Loss - LNA Gain + Free Field Attenuation Power Density = EIRP / (4 * pi * Specification Distance ^ 2) EIRPLimit * The peak power density complies with both peak and average limits. Test report No. : 31JE0273-HO-01-B-R1 Page : 28 of 41 Issued date : August 26, 2011 Revised date : September 2โ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Test report No. : 31JE0273-HO-01-B-R1 Page : 15 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 1: Photographs of test setup Conducted Emission Photo 1 Photo 2 Test report No. : 31JE0273-HO-01-B-R1 Page : 16 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Spurious Emission Photo 1 Photo 2 Test report No. : 31JE0273-HO-01-B-R1 Page : 17 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Carrier Frequency Measurement Photo 1 Photo 2 Test report No. : 31JE0273-HO-01-B-R1 Page : 18 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Frequency Stability Photo 1 Test report No. : 31JE0273-HO-01-B-R1 Page : 19 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 4.2 Configuration and peripherals [Conducted Emission] : Standard Ferrite Core F H G 7 8 9 10 AC 120V/60Hz AC 120V/60Hz [Radiated Emission] : Standard Ferrite Core C A F H E D 4 5 6 3 1 B G 2 7 8 9 10 AC 120V/60Hz AC 120V/60Hz AC 120V/60Hz AC 120V/60Hz 11 Terminator * Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions. Test report No. : 31JE0273-HO-01-B-R1 Page : 20 of 41 Issued date : August 26, 2011 Revised date : September 26, 2011 FCC ID : S8Q-RU5808 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Description of EUT No. Item Model number Serial number Manufacturer Remarks A WIRELESS TRANSMITTER UWIT-Y0001-TX 0000004 Olympus Medical Systems Corp. - B AC ADAPTER OLP-K027-M R/D1 117037 Olympus Medical Systems Corp. - C Personal Computer WF988AV JPA1040N5X hp - D Mouse M-UAL-96 FASTR0C5BZNEWL hp - E Keyboard KU-0316 BAUJD01VBZO1DJ hp - F WIRELESS RECEIVER UWIT-Y0001-RX 0000004 Olympus Medical Systems Corp. EUT G AC ADAPTER OLP-K027-M R/D1 117038 Olympus Medical Systems Corp. EUT H LCD RDT231WLM 01235909AJ MITSUBISHI - List of cables used No. Name Length (m) Shield Remarks Cable Connector 1 DC Cable 2.90 Unshielded Unshielded - 2 AC Cable 2.90 Unshielded Unshielded - 3 DVI-D Cable 3.00 Shielded Shielded - 4 AC Cable 1.90 Unshielded Unshielded - 5 USB Cable 1.75 Shielded Shielded - 6 USB CABLE 1.75 Shielded Shielded - 7 DC Cable 2.90 Unshielded Unshielded - 8 AC Cable 2.90 Unshielded Unshielded - 9 DVI-D Cable 3.00 Shielded Shielded - 10 AC Cable 2.90 Unshielded Unshielded - 11 75 Ohm coaxial Cable 1.00 Shielded Shielded -

Contact Information

Applicant

Mami Nakanishi
[email protected]81426422111Fax: 81426422111

Technical Contact

UL Japan, Inc.Takahiro Hatakeda
[email protected]81-596-24-8116

4383-326 Asama-cho, Ise-shi ยท Mie-ken ยท Japan

Test Firm

UL Japan, Inc. Head office EMC Lab.Tetsuya Hashimoto
[email protected]+81-596-24-8116Fax: +81-596-24-8095

Technical Specifications

#Rule PartsFrequency RangePower Output
115C60.32 GHz - 62.80 GHz17.80 mW
Confidentiality
Long Term
Grant Notes
Output power listed is Conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with specific operating instructions for satisfying RF exposure compliance.

Other Applications from Olympus Medical Systems Corp.

Low Power Transmitter - FCC ID S8QEC-S10 - Olympus Medical Systems Corp.
S8QEC-S10

Low Power Transmitter

Jul 01, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
WIRELESS TRANSMITTER - FCC ID S8Q-RU5796 - Olympus Medical Systems Corp.
S8Q-RU5796

WIRELESS TRANSMITTER

Sep 06, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Endoscope Position Detecting Unit - FCC ID S8QUPD-3 - Olympus Medical Systems Corp.
S8QUPD-3

Endoscope Position Detecting Unit

Jan 05, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Endoscope Reprocessor with RFID - FCC ID S8Q-GN4215 - Olympus Medical Systems Corp.
S8Q-GN4215

Endoscope Reprocessor with RFID

Nov 19, 2007

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
S8QEC-1

Low Power Transmitter

Jan 31, 2006

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter