Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
WARNING The manufacturer is not responsible for any Radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the userβs authority to operate the equipment.β
ONETECH Corp. http://www.onetech.co.kr 505 SK APT Factory, 223-28 Sangdaewon 1-Dong, Jungwon-Gu, Seongnam-City, Kyunggi-Do 462-121, Korea [ Tel ] 82-31-746-8500, [ Fax ] 82-31-746-8700 ONETECH August 03, 2004 FCC Laboratory 7435 Oakland Mills Road Columbia, MD 21046 Attention: Application Examiner Reviewing Engineer Re: Request for confidentiality per Section 0.459 of FCC Rules Applicant: Seoby Electronics Co., Ltd. FCC ID: SCBRCV01 To whom it may concern, Request is hereby submitted, on behalf of my client, Seoby Electronics Co., Ltd, to withhold from public review certain portions of the application for equipment certification for the referenced FCC identifier. In particular, the following sections of the application and report are requested to be kept confidential: Schematics and Block Diagram Rationale for request for confidentiality: Seoby Electronics Co., Ltd, has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the confidential portions of this application to competitors would give them competitive advantage in developing similar products. If you have questions or need further information, please contact the undersigned. Sincerely, Y.K. Kwon / Director Onetech Corp. Email: [email protected]
FCC ID.: SCBRCV01 File No.: E048R-009 ONETECH Testing & Evaluation Lab. FCC ID.: SCBRCV01 File No.: E048R-009 ONETECH Testing & Evaluation Lab. FCC ID.: SCBRCV01 File No.: E048R-009 ONETECH Testing & Evaluation Lab. FCC ID.: SCBRCV01 File No.: E048R-009 ONETECH Testing & Evaluation Lab.
FCC ID.: SCBRCV01 File No.: E048R-009 ONETECH Testing & Evaluation Lab. IDENTIFICATION LABEL: PROPOSED FCC ID LABEL Due to the product size, only the FCC ID shall be permanently affixed to the rear side of the equipment and other information shall be placed in the instruction manual. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. Made in Korea FCC ID : SCBRCV01 FC ID AREA
FCC ID.: SCBRCV01 File No.: E048R-009 ONETECH Testing & Evaluation Lab. FCC ID.: SCBRCV01 File No.: E048R-009 ONETECH Testing & Evaluation Lab. FCC ID.: SCBRCV01 File No.: E048R-009 ONETECH Testing & Evaluation Lab. FCC ID.: SCBRCV01 File No.: E048R-009 ONETECH Testing & Evaluation Lab. FCC ID.: SCBRCV01 File No.: E048R-009 ONETECH Testing & Evaluation Lab.
Operational Description 1. This receiver is a longer distance translation between IR remote to IR home appliances. 2. Normal IR remote can reach 12 - 15 meter without any obstacle or wall. 3. So, this receiver work to translate IR signal to another place or different floor using RF signal transmitting. 4. Receiver is detecting the RF signal from a RF remote far away from the receiver. IR signal of remote is uploaded in RF signal. 5. Receiver catch RF signal and decode IR signal from RF signal . 6. That is, receiver have two features. 1) catch RF signal from a RF remote and decord IR signal from RF signal 2) Transmit IR signal through LED to home appliences. 7. reaching distance 1) 75 feet free space : approx 30-40 feet inside concrete building. 2) Indoor usage : Room-to-Room Control
Page 1 of 11 FCC ID. : SCBRCV01 File No. : E048R-009 This report shall not be reproduced except in full without our written approval. FCC-004 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Kyunggi-Do, 462-121, Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Kwangju-Kun, Kyunggi-Do 464-860 Korea. (TEL: 82-31-765-8289 FAX: 82-31-766-2904) ONETECH Testing & Evaluation Lab. ELECTROMAGNETIC EMISSION C OMPLIANCE REPORT FOR SUPERREGENERATIVE RECEIVER Test report file number : E048R-009 Applicant : SEOBY ELECTRONICS CO., LTD. Address : 38-2 Anyang 2-Dong, Manan-Gu, Anayang City Gyeunggi-Do Korea Manufacturer : SEOBY ELECTRONICS CO., LTD. Address : 38-2 Anyang 2-Dong, Manan-Gu, Anayang City Gyeunggi-Do Korea Type of Equipment : Remote Control Extender FCC ID : SCBRCV01 Basic Model Name : UFO-1000 Multiple Model Name : RCV-1000 Serial number : N/A Total page of Report : 11 pages (including this page) Date of Incoming : June 09, 2004 Date of issuing : August 03, 2004 SUMMARY The equipment complies with the regulation; FCC PART 15 SUBPART B Β§15.101 This test report contains only the result of a single test of the sample supplied for the examination. It is not a general valid assessment of the features of the respective products of the mass-production. Prepared by: Reviewed by: G. W. Lee/ Chief Engineer Y. K. Kwon/ Director EMC Div. EMC Div. ONETECH Corp. ONETECH Corp. Page 2 of 11 FCC ID. : SCBRCV01 File No. : E048R-009 This report shall not be reproduced except in full without our written approval. FCC-004 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Kyunggi-Do, 462-121, Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Kwangju-Kun, Kyunggi-Do 464-860 Korea. (TEL: 82-31-765-8289 FAX: 82-31-766-2904) ONETECH Testing & Evaluation Lab. CONTENTS Page 1. VERIFICATION OF COMPLIANCE ............................................................................................................................3 2. GENERAL INFORMATION...........................................................................................................................................4 2.1 PRODUCT DESCRIPTION................................................................................................................................................4 2.2 RELATED SUBMITTAL(S) / GRANT(S)...........................................................................................................................4 2.3 TEST SYSTEM DETAILS.................................................................................................................................................5 2.4 TEST METHODOLOGY...................................................................................................................................................5 2.5 TEST FACILITY..............................................................................................................................................................5 3. SYSTEM TEST CONFIGURATION..............................................................................................................................5 3.1 JUSTIFICATION..............................................................................................................................................................5 3.2 EUT EXERCISE SOFTWARE...........................................................................................................................................5 3.3 EQUIPMENT MODIFICATIONS.......................................................................................................................................5 3.4 CONFIGURATION OF TEST SYSTEM..............................................................................................................................6 4. PRELIMINARY TEST .....................................................................................................................................................6 4.1 AC POWER LINE CONDUCTED EMISSIONS TESTS........................................................................................................6 4.2 RADIATED EMISSIONS TESTS........................................................................................................................................6 5. FINAL RESULT OF MEASURMENT ...........................................................................................................................7 5.1 CONDUCTED EMISSION TEST........................................................................................................................................7 5.2 RADIATED EMISSION TEST...........................................................................................................................................9 6. FIELD STRENGTH CALCULATION .........................................................................................................................10 7. LIST OF TEST EQUIPMENT.......................................................................................................................................11 Page 3 of 11 FCC ID. : SCBRCV01 File No. : E048R-009 This report shall not be reproduced except in full without our written approval. FCC-004 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Kyunggi-Do, 462-121, Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Kwangju-Kun, Kyunggi-Do 464-860 Korea. (TEL: 82-31-765-8289 FAX: 82-31-766-2904) ONETECH Testing & Evaluation Lab. 1. VERIFICATION OF COMPLIANCE APPLICANT : SEOBY ELECTRONICS CO., LTD. ADDRESS : 38-2 Anyang 2-Dong, Manan-Gu, Anayang City Gyeunggi-Do Korea CONTACT PERSON : Gab-Ju Jung / General Manager TELEPHONE NO : 82-31-474-8001 FCC ID : SCBRCV01 MODEL NO/NAME : UFO-1000 SERIAβ¦
Text truncated - open the document above for the full version.
FCC ID.: SCBRCV01 File No.: E048R-009 ONETECH Testing & Evaluation Lab. FCC ID.: SCBRCV01 File No.: E048R-009 ONETECH Testing & Evaluation Lab.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 433.9 MHz - 433.9 MHz | - |

RF Remote Control Unit
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
RF Remote Control Unit
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Juke Box Remote Controller
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter