FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sensus Metering Systems Inc./
  3. SDBCL202

SDBCL202Command Link II Wireless Interface

Sensus Metering Systems Inc.
Command Link II Wireless Interface - FCC ID SDBCL202 - Sensus Metering Systems Inc.
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Mar 09, 2026
Application Purpose
Original Equipment
Equipment Note
Command Link II Wireless Interface
Frequency Range
896.00000000 - 901.00000000
Company
Sensus Metering Systems Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Quick Guide AQG-10087-06 1FlexNet CommandLink II Quick Guide FlexNet CommandLink II The CommandLink® II wireless interface provides access to a complete suite of functional controls within a gas, water, or electric SmartPoint® transceiver. This Bluetooth® enabled device, coupled with a handheld, can perform activations, deactivation, meter read, on demand reads and audits of the SmartPoint module. FieldLogic connects wirelessly (using Bluetooth®) through the CommandLink® (CL) to communicate with SmartPoint modules installed in the FlexNet network. CommandLink II Kit components • FlexNet® CommandLink II • Bungee straps (2) • Charging adapter (AC/DC) • Vehicle charging adapter (DC/DC) • Case Step 1: Charge the CommandLink II You must charge the CommandLink II completely before first use. 1. Plug the charging adapter into a power outlet and connect to the Charging Port located next to the Mag Loop on top of the Command Link II. The red LED indicator illuminates, indicating the unit is charging. 2. Unplug the unit when the red LED is no longer illuminated, indicating the CommandLink II is fully charged. 3. To power down the CommandLink II immediately, press and hold the power button located on the side of the CommandLink II until the PWR LED turns off. Step 2: Turn on the CommandLink II 1. Press the power button. 2. The green LED light illuminates when the CommandLink II is successfully powered. Step 3: Create a Bluetooth Partnership To use the CommandLink II, establish a Bluetooth partnership with a Windows Mobile, Android or iOS equipped handheld device (HHD). See page 2. Step 4: Attach the Strap Slide the provided strap in between the slots on the sides of the unit. 1 Key: 1) Mag Loop 2) Charging Port 3) Battery Cover 4) Strap Clip 5) LED Indicators 6) Power LEDDescription CHG (Red)Charging LNK (Blue)Bluetooth connected PWR (Green)Solid: power on Flash: needs charge/poor battery connection/defective battery Battery Usage Note: Make sure you have rechargeable batteries installed before using a power outlet. Units that have non- rechargeable batteries should never be plugged into a power outlet for charging. 2FlexNet CommandLink II Quick Guide Connect via an Android field device 1. From the FieldLogic Tools home screen, select the three-dot menu icon. 2. Select Options from the drop-down menu. 3. Select FlexNet. FieldLogic Tools scans for and displays the available Bluetooth devices. 4. Select + to pair with an available Bluetooth device. The operating system Bluetooth connections screen opens. 5. Select the CommandLink II to pair it. It will have CL as the Bluetooth prefix. 6. If prompted to select a PIN, choose a PIN number. You may need to enter this PIN number in future when pairing the device. After pairing, the device displays in the Paired Devices list. 7. Select the back arrow to return to FieldLogic. 8. Select the icon beside your device. FieldLogic displays a connection success message. Note: Do not select devices with “_BLE” appended to the device name. 9. Select the back arrow to return to the main screen. Connect via an iOS field device 1. From the FieldLogic Tools home screen, select the three-dot menu icon. 2. Select Options from the drop-down menu. 3. Select FlexNet. FieldLogic Tools scans for and displays the available Bluetooth devices. 4. Select the CommandLink II to pair it. It will have CL as the Bluetooth prefix. Then select the information icon. Note: Make sure that the device name you select has “_BLE” appended to the device name. 5. FieldLogic Tools connects to the device and displays a success message. 6. Select Close to return to Options. 7. Select the back arrow to return to the main screen. Connect via a Windows 11 App field device 1. From the FieldLogic Tools home screen, select the three-dot menu icon. 2. Select Options from the drop-down menu. 3. Select FlexNet. FieldLogic Tools scans for and displays the available Bluetooth devices. 4. Select the CommandLink II to pair it. It will have CL as the Bluetooth prefix. 5. If prompted to select a PIN, choose a PIN number. You may need to enter this PIN number in future when pairing the device. After pairing, the device displays in the Paired Devices list. 6. Select the icon beside your device. FieldLogic displays a connection success message. Note: Do not select devices with “_BLE” appended to the device name. 7. Select the back arrow to return to the main screen. All information presented herein is believed reliable and in accordance with accepted engineering practices. Xylem makes no warranties as to the completeness of this information. Users are responsible for evaluating individual product suitability for specific applications. Xylem assumes no liability whatsoever for any special, indirect or consequential damages arising from the sale, resale or misuse of its products. Subject to change without notice. © 2026 Xylem Inc. or its affiliates. All rights reserved. FlexNet® is a trademark of Xylem or one of its subsidiaries. AQG-10087-06 Xylem 639 Davis Drive Morrisville, NC 27560 Tel +1 800.638.3745 xylem.com xylem.com/sensus Compliance Statements Attention! Any modifications made to this device that are not approved by Sensus may void the authority granted to the user by the FCC to operate equipment. Attention! For Class B - Unintentional Radiators:This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Attention! ICES-003 Class B Notice—Avis NMB-003, Class B This Class B digital apparatus complies with Canadian ICES-003. Attention! Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equi…

Text truncated - open the document above for the full version.

Attestation Statements

Hardware Test-Regulatory T: 919-665-7878 639 Davis Drive F: 919-317-6210 Morrisville, NC 27560 USA www.sensus.com To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: February 25, 2026 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: SDBCL202 Sensus (“the applicant”) certifies that, as of the date of the filing of the application, Ray Britt is our designated U.S. agent for service of process for the above referenced FCC ID. Sensus accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Sensus accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Sensus USA Inc. Address: 637 Davis Drive, Morrisville, NC 27560 USA Contact Person: Ray Britt Tel.: 919-665-7878 Email: [email protected] FRN: 0003180007 Sincerely, Ray Britt | Sr. Director, Global System Test 637 Davis Drive | Morrisville, NC 27560 USA T: 919-665-7878 | F: 919-317-6210 | [email protected] | www.sensus.com

Attestation Statements

Hardware Test-Regulatory T: 919-665-7878 637 Davis Drive F: 919-317-6210 Morrisville, NC 27560 USA www.sensus.com Date: February 25, 2026 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(5)(i) and Part 2.911(d)(5)(ii) Filing Re. KDB 986446 D01 FCC ID: SDBCL202 Dear Sir or Madam, Sensus (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. We further attest that the equipment for which authorization is sought does not contain, nor will it ever contain, integrated Kaspersky cybersecurity and/or anti-virus software produced by Kaspersky Lab Inc. or any of its successors and assignees. If you have any questions, please contact us. Sincerely, Contact name: Ray Britt Company name: Sensus USA Inc. Address: 637 Davis Drive, Morrisville, NC 27560 USA E-mail: [email protected] Tel: 919-665-7878

Cover Letter(s)

Hardware Test-Regulatory T: 919-665-7878 637 Davis Drive F: 919-317-6210 Morrisville, NC 27560 USA www.sensus.com Date 02/25/2026 TUV SUD America Inc. 401 Edgewater Drive Ste 500 Wakefield MA 01880 Dear Sir or Madam, We, Sensus, 637 Davis Drive, Morrisville, NC 27560 hereby authorize Anes Dahmane of TUV SUD America, 5945 Cabot Parkway, Alpharetta, GA 30005 to act as our agent in all matters relating to application FCCID: SDBCL202 and IC: 2220A-CL202 for equipment authorization, including the signing of all documents relating to these matters. Sincerely, Contact name: Ray Britt Company name: Sensus USA Inc. Address: 637 Davis Drive, Morrisville, NC 27560 USA E-mail: [email protected] Tel: 919-665-7878

Cover Letter(s)

Hardware Test-Regulatory T: 919-665-7878 637 Davis Drive F: 919-317-6210 Morrisville, NC 27560 USA www.sensus.com February 25, 2026 Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: SDBCL202 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type Justification Schematic Proprietary Information and Trade Secret Parts List Proprietary Information and Trade Secret Theory of Operation Proprietary Information and Trade Secret Internal Photos Proprietary Information and Trade Secret Block Diagram Proprietary Information and Trade Secret Tune Up Procedure Proprietary Information and Trade Secret Confidentiality of the Internal Photos is being requested because this is a non-consumer device which is not accessible by the general public and is only serviceable by the applicant or designated technicians. Internal photos are not distributed except for regulatory filings or manufacturing documentation. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The product covered by this Confidentiality Request may or may not be sold to any OEM and is only installed in Sensus Products by Sensus Employees or Contractors. All sales of this non-consumer product are to third parties that are subject to the NDA. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Ray Britt | Sr. Director, Global System Test 637 Davis Drive | Morrisville, NC 27560 USA T: 919-665-7878 | F: 919-317-6210 | [email protected] | www.sensus.com

Cover Letter(s)

Confidential 0 NON- DISCLOSURE AGREEMENT This Non-Disclosure Agreement (“Agreement”) is made this DATE (“Effective Date”), between Sensus USA Inc., of 8601 Six Forks Road, Suite 700, Raleigh, North Carolina, 27615 (“Discloser”) and COMPANY NAME, located at ADDRESS (“Recipient”). Whereas, the parties wish to engage in binding contracts that involve BUSINESS REASON FOR NDA; Whereas, the Discloser may disclose Confidential Information, as defined herein, to the Recipient in the course of these activities; Whereas, both parties desire to protect the Confidential Information which may be disclosed to the Recipient. IT IS AGREED: 1. Confidential Information. “Confidential Information” means any and all non-public information disclosed by the Discloser to the Recipient for the Purpose including, without limitation, all technical information about the Discloser’s products or services, product specifications, pricing, marketing, other business or financial information or plans of the Discloser, and all trade secrets of the Discloser. The Confidential Information may be transmitted orally, in writing or electronically. Notwithstanding the foregoing, “Confidential Information” shall not include, (i) any information that is in the public domain other than due to a breach of this Agreement, (ii) any information in the possession of the Recipient prior to disclosure by the Discloser hereunder, or (iii) any information independently developed by the Recipient without reliance on the information disclosed hereunder by the Discloser. 2. Protection. For three (3) years after the date of disclosure, the Recipient shall keep all Confidential Information of the Discloser confidential, provided that trade secret information shall be maintained in confidence until the longer of (i) three years from the date of disclosure; or (ii) until the information is no longer a trade secret under applicable law. Except as provided in Section 3, the Recipient shall not, directly or indirectly, disclose the Confidential Information to any third party, and the Recipient shall take reasonable care to protect the Discloser’s Confidential Information. The Recipient shall not make any copies of any tangible documentation or materials provided hereunder, except to the extent necessary for the Purpose. The Recipient shall not use the Confidential Information of the Discloser for any reason other than for the Purpose. 3. Permitted Disclosures. The Recipient may only disclose the Confidential Information provided hereunder to its employees, agents, consultants and contractors who are directly involved in the Purpose and whom the Recipient has legally bound to comply with reasonable confidentiality obligations. The Recipient may also disclose Confidential Information to the extent it is obliged to do so under applicable laws, so long as it gives the Discloser reasonable notice to enable the Discloser to take protective steps. 4. Return. Upon request of the Discloser, the Recipient shall either (i) return all Confidential Information (including all copies) to the Discloser; or (ii) destroy all Confidential Information (including all copies) and provide written certification of their destruction to the Discloser 5. Term. This Agreement shall commence on the Effective Date and shall continue for three (3) years after the Effective Date. The provisions of this Agreement that are applicable to Confidential 1 circumstances occurring after termination or expiration shall survive such termination or expiration. 6. Warranty. Both parties represent and warrant that they have the right to engage in the discussions, and the Discloser represents that it has the right to disclose all information disclosed in the discussions. Notwithstanding the above, the Discloser does not make any representation or warranty as to the accuracy or completeness of the Confidential Information. 7. No Obligations. The Discloser is under no obligation to disclose Confidential Information. Nothing in this Agreement obligates either party (i) to offer for sale any product or service using or incorporating the Confidential Information; or (ii) to purchase any product or service from the other party. 8. Ownership. All rights in the Confidential Information disclosed remain the property of the Discloser. The Recipient does not acquire any intellectual property rights to the Discloser’s Confidential Information. 9. Entire Agreement. This Agreement constitutes the entire agreement between the parties related to the subject matter hereof, and it supersedes any and all prior agreements, understanding or other communications, whether written or oral, formal or informal, between them. No consent, waiver, alteration, amendment, or modification shall be binding unless in writing and signed by both parties. 10. Assignment. Neither party may assign its rights or delegate its duties or obligations under this Agreement without the prior written consent of the other party. 11. Governing Law and Jury Waiver. This Agreement shall be governed by, construed and enforced in accordance with the laws of the State of Delaware, USA. TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE PARTIES AGREE TO A BENCH TRIAL AND THAT THERE SHALL BE NO JURY IN ANY DISPUTES. 12. Injunctive Relief. Both parties acknowledge that a breach of this Agreement can cause the Discloser to suffer irreparable harm. IF ANY SUCH BREACH OCCURS OR IS THREATENED, THE DISCLOSER MAY SEEK INJUNCTIVE RELIEF, SPECIFIC PERFORMANCE AND OTHER EQUITABLE REMEDIES (IN ADDITION TO ANY AND ALL OTHER REMEDIES AT LAW) WITHOUT PROOF OF MONETARY DAMAGES OR THE INADEQUACY OF OTHER REMEDIES, AND THE RECIPIENTWAIVES ITS RIGHT TO ALL SUCH DEFENSES. 13. Limitation of Liability. The Discloser’s liability in any cause of action arising under, out of, or in relation to this Agreement, its negotiation, performance, breach or termination (collectively, “Cause of Action”) shall be limited to direct damages. The Discloser shall not be liable for any indirect,…

Text truncated - open the document above for the full version.

External Photos

Figure 1: View 1 Figure 2: View 2 Figure 3: View 3 Figure 4: View 4 Figure 5: View 5

ID Label/Location Info

Label Label Location

RF Exposure Info

© 2026 RF Exposure Lab, LLC This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. 802 N. Twin Oaks Valley Road, Suite 105 • San Marcos, CA 92069 • U.S.A. TEL (760) 471-2100 • FAX (760) 471-2121 http://www.rfexposurelab.com CERTIFICATE OF COMPLIANCE SAR EVALUATION Sensus USA Inc. Dates of Test: February 25, 2026 639 Davis Drive Test Report Number: SAR.20260220 Morrisville, NC 27560 Lab Designation Number: US1195 This wireless mobile and/or portable device has been shown to be compliant for localized specific absorption rate (SAR) for uncontrolled environment/general exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in IEC 62209- 1528:2020 and KDB 447498 (See test report). I attest to the accuracy of the data. All measurements were performed by myself or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. RF Exposure Lab, LLC certifies that no party to this application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Jay M. Moulton Vice President Testing Cert. # 2387.01 FCC ID: SDBCL202 Model(s): CL202 Test Sample: Engineering Unit Same as Production Serial Number: Eng 1 Equipment Type: Wireless Receiver/Transmitter Classification: Portable Transmitter Next to Body TX Frequency Range: 2402 – 2480 MHz; 896 – 960 MHz Frequency Tolerance: ± 2.5 ppm Maximum RF Output: 2450 MHz – 12.00 dBm; 900 MHz – 21.00 dBm Conducted Signal Modulation: 2-GFSK, GFSK Antenna Type: Internal Antenna Application Type: Certification FCC Rule Parts: Part 2, 15 KDB Test Methodology: KDB 447498 D01 v06 Maximum SAR Value: 0.54 W/kg Reported Maximum Simultaneous SAR: 0.61 W/kg Reported Separation Distance: 0 mm Report Number: SAR.20260220 © 2026 RF Exposure Lab, LLC Page 2 of 72 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Table of Contents 1. Introduction ................................................................................................................................................ 4 SAR Definition [5] .......................................................................................................................................... 5 2. SAR Measurement Setup .......................................................................................................................... 6 Robotic System ............................................................................................................................................. 6 System Hardware .......................................................................................................................................... 6 System Electronics ........................................................................................................................................ 7 Probe Measurement System ......................................................................................................................... 7 3. Probe and Dipole Calibration ................................................................................................................... 14 4. Phantom & Simulating Tissue Specifications ........................................................................................... 15 Head Simulating Mixture Characterization ................................................................................................... 15 5. ANSI/IEEE C95.1 – 1992 RF Exposure Limits [2] .................................................................................... 16 Uncontrolled Environment ............................................................................................................................ 16 Controlled Environment ............................................................................................................................... 16 6. Measurement Uncertainty ........................................................................................................................ 17 7. System Validation .................................................................................................................................... 18 Tissue Verification ....................................................................................................................................... 18 Test System Verification .............................................................................................................................. 18 8. SAR Test Data Summary ......................................................................................................................... 19 Procedures Used To Establish Test Signal .................................................................................................. 19 Device Test Condition .................................................................................................................................. 19 9. Simultaneous Transmission Analysis ....................................................................................................... 24 10. Test Equipment List ............................................................................................................................. 25 11. Conclusion ........................................................................................................................................... 26 12. References .......................................................................................................................................... 27 Appendix A – System Validation Plots and Data .............................................................................................. …

Text truncated - open the document above for the full version.

Test Report

DOCUMENT CONTROL NUMBER Non-Specific Radio Report Shell Rev. January 2025 © 2025 INTERTEK SENSUS METERING SYSTEMS INC. TEST REPORT SCOPE OF WORK RADIO TESTING – COMMANDLINK II (CL202) REPORT NUMBER 106487294ATL-001 ISSUE DATE REVISED DATE 27 February 2026 05 March 2026 PAGES 68 RADIO TEST REPORT Report Number: 106487294ATL-001 Project Number: G106487294 Report Revised Date: 05 March 2026 Model(s) Tested: CL202 FCC ID: SDBCL202 IC: 2220A-CL202 Standards: 47 CFR Part 24 Subpart D 47 CFR Part 90 Subpart I 47 CFR Part 101 Subpart C RSS-119, Issue 12 RSS-134, Issue 2 ANSI C63.26-2015 RSS-GEN, Issue 5 Test Location Client Intertek 1950 Evergreen Blvd., Suite 100 Duluth, GA 30096 USA FCC Designation: US1046 ISED CAB Designator: US0128 Sensus Metering Systems Inc. 639 Davis Drive Morrisville, NC 27560 USA Report prepared by Report reviewed by Jeremy Pickens / Senior Staff Engineer Michael Carlson / Staff Engineer This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Report Number: 106487294ATL-001 Revised: 05 March 2026 Non-Specific Radio Report Shell Rev. January 2025 Page 3 of 68 Sensus Metering Systems Inc. / Model CL202 Table of Contents 1 Introduction and Conclusion .............................................................................................................. 4 2 Test Summary ...................................................................................................................................... 4 3 Client Information ................................................................................................................................ 5 4 Description of Equipment Under Test and Variant Models ............................................................. 5 5 System Setup and Method .................................................................................................................. 7 6 RF Output Power .................................................................................................................................. 9 7 Out of Band Unwanted Emissions ................................................................................................... 12 8 Occupied Bandwidth ......................................................................................................................... 27 9 Spurious Emissions at Antenna Terminals .................................................................................... 41 10 Field Strength of Spurious Emissions ......................................................................................... 48 11 Frequency Stability ........................................................................................................................ 57 12 Measurement Uncertainty ............................................................................................................. 67 13 Revision History ............................................................................................................................. 68 Intertek Report Number: 106487294ATL-001 Revised: 05 March 2026 Non-Specific Radio Report Shell Rev. January 2025 Page 4 of 68 Sensus Metering Systems Inc. / Model CL202 1 Introduction and Conclusion The tests indicated in Section 2 were performed on the product constructed as described in Section 4. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. Intertek does not make any claims of compliance for samples or variants which were not tested. 2 Test Summary Section Test Description Test Specification Result FCC Rule Part ISED RSS 6 RF Output Power 2.1046 24.132 90.204 101.113(a) RSS-GEN S6.12 RSS-119 S5.4 RSS-134 S4.3(a),(b) Compliant 7 Out of Band Unwanted Emissions 2.1051 24.133(a)(1),(2) 90.210(i) 101.111(a)(5) 101.111(a)(6) RSS-Gen S6.13 RSS-119 S5.8.3 RSS-119 S5.8.6 RSS-134 S4.4 Compliant 8 Occupied Bandwidth 2.1049 24.131 90.209(b)(5) 101.109 RSS-GEN S6.7 RSS-119 S5.5 RSS-134 S4.1 Compliant 9 Spurious Emissions at Antenna Terminals 2.1051 24.133(a)(1),(2) 90.210(i) 101.111(a)(5) 101.111(a)(6) RSS-Gen S6.13 RSS-119 S5.8.3 RSS-119 S5.8.6 RSS-134 S4.4 Compliant 10 Field Strength of Spurious Emissions 2.1053 24.133(a)(1),(2) 90.210(i) 101.111(a)(5) 101.111(a)(6) RSS-Gen S6.13 RSS-119 S5.8.3 RSS-119 S5.8.6 RSS-134 S4.4 Compliant 11 Frequency Stability 2.1055 24.135 90.213 101.107 RSS-GEN S6.11 RSS-119 S5.3 RSS-134 S4.5 Compliant Intertek Report Number: 106487294ATL-001 Revised: 05 March 2026 Non-Specific Radio Report Shell Rev. January 2025 Page 5 of 68 Sensus Metering Systems Inc. / Model CL202 3 Client Information This evaluation was performed at the request of: Client: Sensus Metering Systems Inc…

Text truncated - open the document above for the full version.

Test Setup Photos

Sensus Metering Systems, Inc. Test Setup Photographs FCC ID: SDBCL202 IC: 2220A-CL202 Antenna Port Conducted Emissions Frequency Stability Radiated Spurious Emissions 30MHz-1GHz Radiated Spurious Emissions 30MHz-1GHz Radiated Spurious Emissions 1GHz-10GHz Radiated Spurious Emissions 1GHz-10GHz

Contact Information

Applicant

Ray Britt(Senior Director, Global System Test)
[email protected]Fax: 919-317-6210

Technical Contact

Sensus a Xylem BrandRay Britt
[email protected]

637 Davis Dr · Morrisville, 27560 · United States

Test Firm

Intertek Testing Services NA Inc.Jeff Hiday
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
124D901 MHz - 902 MHz109.00 mW5K90F1D1ppm
224D901 MHz - 902 MHz109.00 mW11K8F1D1ppm
324D901 MHz - 902 MHz109.00 mW14K8F1D1ppm
424D901 MHz - 902 MHz85.00 mW10K3F2D1ppm
524D930 MHz - 931 MHz98.00 mW5K90F1D1ppm
624D930 MHz - 931 MHz98.00 mW11K8F1D1ppm
724D930 MHz - 931 MHz98.00 mW14K8F1D1ppm
824D930 MHz - 931 MHz98.00 mW10K3F2D1ppm
924D940 MHz - 941 MHz95.00 mW5K90F1D1ppm
124D940 MHz - 941 MHz95.00 mW11K8F1D1ppm
1124D940 MHz - 941 MHz95.00 mW14K8F1D1ppm
1224D940 MHz - 941 MHz76.00 mW10K3F2D1ppm
139896 MHz - 901 MHz115.00 mW5K90F1D1ppm
149896 MHz - 901 MHz115.00 mW11K8F1D1ppm
159896 MHz - 901 MHz115.00 mW14K8F1D1ppm
169935 MHz - 940 MHz96.00 mW5K90F1D1ppm
179935 MHz - 940 MHz96.00 mW14K8F1D1ppm
18101C928.85 MHz - 929 MHz98.00 mW5K90F1D1ppm
19101C928.85 MHz - 929 MHz98.00 mW11K8F1D1ppm
2101C928.85 MHz - 929 MHz98.00 mW14K8F1D1ppm
21101C928.85 MHz - 929 MHz79.00 mW10K3F2D1ppm
22101C932 MHz - 932.5 MHz96.00 mW5K90F1D1ppm
23101C932 MHz - 932.5 MHz96.00 mW11K8F1D1ppm
24101C932 MHz - 932.5 MHz96.00 mW14K8F1D1ppm
25101C932 MHz - 932.5 MHz78.00 mW10K3F2D1ppm
26101C941 MHz - 941.5 MHz95.00 mW5K90F1D1ppm
27101C941 MHz - 941.5 MHz95.00 mW11K8F1D1ppm
28101C941 MHz - 941.5 MHz95.00 mW14K8F1D1ppm
29101C941 MHz - 941.5 MHz76.00 mW10K3F2D1ppm
3101C959.85 MHz - 960 MHz90.00 mW5K90F1D1ppm
31101C959.85 MHz - 960 MHz90.00 mW11K8F1D1ppm
32101C959.85 MHz - 960 MHz90.00 mW14K8F1D1ppm
33101C959.85 MHz - 960 MHz72.00 mW10K3F2D1ppm
Confidentiality
Long Term
Grant Notes
Power listed is average conducted. This device is valid for professional use only. End-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Device is co-located with FCC ID: QOQ-BT122. The highest reported SAR values for body-worn accessory and simultaneous transmission exposure conditions are 0.54 W/kg and 0.61 W/kg, respectively.

Other Applications from Sensus Metering Systems Inc.

Remote Telemetry Module - FCC ID SDBWFL3 - Sensus Metering Systems Inc.
SDBWFL3

Remote Telemetry Module

Mar 04, 2026

Equipment Class

DTS - Digital Transmission System
SDBIDTB007

Stratus IQ+ Radio Module

Sep 28, 2023

Equipment Class

PCB - PCS Licensed Transmitter
Base Station Transceiver - FCC ID SDBM420V01 - Sensus Metering Systems Inc.
SDBM420V01

Base Station Transceiver

Jan 05, 2023

Equipment Class

PCB - PCS Licensed Transmitter
Base Station Transceiver - FCC ID SDBM420V00 - Sensus Metering Systems Inc.
SDBM420V00

Base Station Transceiver

Jan 05, 2023

Equipment Class

PCB - PCS Licensed Transmitter
SDBFLXI2102

Remote Telemetry Module

Apr 13, 2022

Equipment Class

PCB - PCS Licensed Transmitter