FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sensus Metering Systems Inc./
  3. SDBWFL3

SDBWFL3Remote Telemetry Module

Sensus Metering Systems Inc.
Remote Telemetry Module - FCC ID SDBWFL3 - Sensus Metering Systems Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 04, 2026
Application Purpose
Original Equipment
Equipment Note
Remote Telemetry Module
Frequency Range
902.75000000 - 914.75000000
Company
Sensus Metering Systems Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Installation Guide WIG-10020-02 1525M SmartPoint ® Module Pit-Set Installation SmartPoint ® 525M Module Pit-Set Installation Instructions Components 6 5 4 3 2 1 1) Pit housing 2) Pit locking nut 3) Probe boot 4) TR/PL adaptor (TouchCoupler enabled units only) 5) HDPE Radio 6) Boot locking clip Refer to the 525M Compatibility Quick Guide for inline connector compatibility. Refer to FieldLogic documentation for programming instructions. NOTE: This installation sheet is only for pit-set installation of the Sensus Model 525M. For instructions on installing other AMI devices, please refer to the individual installation instruction for those devices. STOP! DO NOT install a 525M on a metal pit lid. TouchCoupler Installation Step 1. Disassemble the 525M unit • Disassemble the Model 525 SmartPoint module to begin the installation procedure. Unlock the radio device by pressing down on the two tabs on the Boot locking clip facing the port side connections. Once the tabs are depressed, slide the Boot locking clip out by pushing down and out until the Pit Lid housing is released from the Boot. • Slide the Pit Lid housing off of the Boot and Boot locking clip assembly. • Remove the Pit locking nut from the underneath of the Pit Lid housing by turning the nut counter clockwise. 1 The 525M SmartPoint module is designed for pit set and wall mount environments and is available for single port operation. It must be installed through a non-metal pit lid to maximize performance in fixed base applications. The module can be installed with either a TouchCoupler connection or wire connection. 2525M SmartPoint ® Module Pit-Set Installation Step 2. Insert the Pit Lid housing • Place the Pit Lid housing thru the pre- drilled hole in the top of the Pit Lid. Pit Lid Housing Inserted Through Pit Lid (Top View) Pit Lid Housing Inserted Through Pit Lid (Bottom View) Step 3. Secure the Pit Lid Housing • Place the Pit Locking Nut at the bottom of the Pit Lid Housing aligning the Pit Locking Nut with the shaft of the Pit Lid Housing. Tighten the Pit Locking Nut by turning clockwise until the unit is firmly secured against the bottom of the Pit Lid. Step 4. Insert the Radio Device • Insert the HDPE Radio with Boot attached into the cavity of the Pit Lid Housing (see picture below). • Slide the Boot Locking Clip into the Boot while assuring alignment between the slot located on the bottom of the Pit Lid Housing and the Boot Locking Clip is achieved. • To secure the module, slide the Boot Locking Clip into the Boot until the Boot Locking Clip rests in the slot located on the bottom of the Pit Lid Housing and the Boot Locking Clip is engaged and locked. Step 5. Place the TR/PL Sensor • Perform a TouchRead on TR/PL sensor to ensure TouchRead to the encoder works. • Grasp the TR/PL sensor and place into Port 1 of the TouchCoupler TR/PL Adaptor until secured. Single Port – Wired Installation Recommended Tools and Materials: • 3M Scotchlok®UY-2 butt connector “gel-caps” • 3M Scotchlock®E-9Y stepped jaw crimping tool with wire cutter • Wire stripping tool • Three conductor solid wire (Sensus specification) 1. Strip approximately 2” off the outer jacket of the encoder wire cable. The wire colors for each module should be green, red and black. 2. The red, green and black wires must be gel-capped individually. Insert the corresponding wires, as indicated in the encoder wiring reference table, into the gel-cap with the color button of the gel-cap facing away. This provides a better view of wire positions inside the clear plastic gel-cap, enabling the installer to see the wires are completely and properly inserted. SmartPoint Terminal Sensus Register Badger ADENeptune ProRead BlackBlackBlackGreen RedRedRedBlack GreenGreenGreenRed 3. Using gel-cap pliers, squeeze the gel-cap. This will splice the two wires and release the waterproof gel to seal the connection. The splice can be checked by pulling gently on the gel-cap while holding the wires to be sure they are tight and secure. Repeat this process for the remaining two wire connections. NOTE: If any of the wire connections are not being used they should be capped at the end with a gel-cap. This is to prevent wire damage due to water intrusion via wicking through the exposed wire ends. Badger, Neptune and Elster registers must be wired directly to a 525M port. 4. Coil and secure excess cable to the body of the meter or service line in a presentable manner. 3525M SmartPoint ® Module Pit-Set Installation Compliance Statements Warning! The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter. L’antenne utilisée pour cet émetteur ne doit pas être co-localisée avec une autre antenne ou un autre émetteur. Attention! Any modifications made to this device that are not approved by Sensus may void the authority granted to the user by the FCC to operate equipment. Toute modification apportée à cet appareil qui n’est pas approuvée par Sensus peut annuler l’autorisation accordée à l’utilisateur par la FCC pour faire fonctionner l’équipement. Attention! ICES-003 Class B Notice—Avis NMB-003, Class B This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la classe B est conforme à la norme NMB-003 du Canada. Warning! DO NOT INCINERATE or subject battery cells to temperatures in excess of 212°F. Such treatment can cause cell rupture. NE PAS INCINÉRER ni exposer les cellules de la batterie à des températures dépassant 100°C (212 °F). Un tel traitement peut provoquer la rupture des cellules. Warning! There is danger of explosion if batteries are mishandled or incorrectly replaced. On systems with replaceable batteries, replace only with the same manufacturer and type or equivalent type recommended per the instructions provided in the product service manual. Do not disassemble batteries or attempt to recharge them outside the system. Do not dispose of batteries in fire. Dispose of batteries properly in accordance wi…

Text truncated - open the document above for the full version.

Attestation Statements

Hardware Test-Regulatory T: 919-665-7878 639 Davis Drive F: 919-317-6210 Morrisville, NC 27560 USA www.sensus.com To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: February 24, 2026 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: SDBWFL3 Sensus (“the applicant”) certifies that, as of the date of the filing of the application, Ray Britt is our designated U.S. agent for service of process for the above referenced FCC ID. Sensus accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Sensus accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Sensus USA Inc. Address: 637 Davis Drive, Morrisville, NC 27560 USA Contact Person: Ray Britt Tel.: 919-665-7878 Email: [email protected] FRN: 0003180007 Sincerely, Ray Britt | Sr. Director, Global System Test 637 Davis Drive | Morrisville, NC 27560 USA T: 919-665-7878 | F: 919-317-6210 | [email protected] | www.sensus.com

Attestation Statements

Hardware Test-Regulatory T: 919-665-7878 637 Davis Drive F: 919-317-6210 Morrisville, NC 27560 USA www.sensus.com Date: February 24, 2026 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(5)(i) and Part 2.911(d)(5)(ii) Filing Re. KDB 986446 D01 FCC ID: SDBWFL3 Dear Sir or Madam, Sensus (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. We further attest that the equipment for which authorization is sought does not contain, nor will it ever contain, integrated Kaspersky cybersecurity and/or anti-virus software produced by Kaspersky Lab Inc. or any of its successors and assignees. If you have any questions, please contact us. Sincerely, Contact name: Ray Britt Company name: Sensus USA Inc. Address: 637 Davis Drive, Morrisville, NC 27560 USA E-mail: [email protected] Tel: 919-665-7878

Cover Letter(s)

Hardware Test-Regulatory T: 919-665-7878 637 Davis Drive F: 919-317-6210 Morrisville, NC 27560 USA www.sensus.com LETTER OF AUTHORIZATION February 24, 2026 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: I hereby appoint Rossana Sarai of TĂśV SĂśD to act as our agent in the preparation of an application for an equipment authorization of the SDBWFL3 to the FCC Rules and Regulations. I certify that all exhibits contained within this filing properly describe the device or system for which the permissive change is sought. I further certify that appropriate arrangements have been made to assure that production units of this equipment bearing the name 525M and FCC IDENTIFIER SDBWFL3 listed in this application will continue to comply with the Commission's requirements. I further certify by signature below that no party (per 47 CFR 1.2002(b)) to the application is subject to a denial of Federal benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This appointment also includes the authority to complete FCC Form 731 on our behalf and sign the application as an authorized agent. This authorization is valid for 525M ONLY and shall not be utilized for any other matters on the behalf of Sensus. Sincerely, Ray Britt | Sr. Director, Global System Test 637 Davis Drive | Morrisville, NC 27560 USA T: 919-665-7878 | F: 919-317-6210 | [email protected] | www.sensus.com

Cover Letter(s)

Hardware Test-Regulatory T: 919-665-7878 637 Davis Drive F: 919-317-6210 Morrisville, NC 27560 USA www.sensus.com February 24, 2026 Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: SDBWFL3 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type Justification Schematic Proprietary Information and Trade Secret Parts List Proprietary Information and Trade Secret Theory of Operation Proprietary Information and Trade Secret Internal Photos Proprietary Information and Trade Secret Block Diagram Proprietary Information and Trade Secret Tune Up Procedure Proprietary Information and Trade Secret Confidentiality of the Internal Photos is being requested because this is a non-consumer device which is not accessible by the general public and is only serviceable by the applicant or designated technicians. Internal photos are not distributed except for regulatory filings or manufacturing documentation. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The product covered by this Confidentiality Request may or may not be sold to any OEM and is only installed in Sensus Products by Sensus Employees or Contractors. All sales of this non-consumer product are to third parties that are subject to the NDA. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Ray Britt | Sr. Director, Global System Test 637 Davis Drive | Morrisville, NC 27560 USA T: 919-665-7878 | F: 919-317-6210 | [email protected] | www.sensus.com

Cover Letter(s)

TUV SUD America, 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005 Document: 120780 v1 Page 1 of 1 Date: February 26, 2026 Federal Communications Commission Laboratory 7435 Oakland Mills Road Columbia, MD 21046 Re: FCC ID: SDBWFL3 To Whom It May Concern: The following application is submitted on behalf of our client, Sensus Metering Systems, for evaluation of their model 525M for a new certification under FCC Part 24D, 101C and 15.247. There are two variants of the model, a 3-Wire meter interface and a touchcouple meter interface. Both variants have the exact same RF PCB layout. The NFC radio is a battery assisted passive tag. I have reviewed the application and supporting documentation and have found them to comply with FCC requirements. I recommend this application for certification. Yours sincerely Jeff Woods TUV SUD Senior Engineer

Cover Letter(s)

Confidential 0 NON- DISCLOSURE AGREEMENT This Non-Disclosure Agreement (“Agreement”) is made this DATE (“Effective Date”), between Sensus USA Inc., of 8601 Six Forks Road, Suite 700, Raleigh, North Carolina, 27615 (“Discloser”) and COMPANY NAME, located at ADDRESS (“Recipient”). Whereas, the parties wish to engage in binding contracts that involve BUSINESS REASON FOR NDA; Whereas, the Discloser may disclose Confidential Information, as defined herein, to the Recipient in the course of these activities; Whereas, both parties desire to protect the Confidential Information which may be disclosed to the Recipient. IT IS AGREED: 1. Confidential Information. “Confidential Information” means any and all non-public information disclosed by the Discloser to the Recipient for the Purpose including, without limitation, all technical information about the Discloser’s products or services, product specifications, pricing, marketing, other business or financial information or plans of the Discloser, and all trade secrets of the Discloser. The Confidential Information may be transmitted orally, in writing or electronically. Notwithstanding the foregoing, “Confidential Information” shall not include, (i) any information that is in the public domain other than due to a breach of this Agreement, (ii) any information in the possession of the Recipient prior to disclosure by the Discloser hereunder, or (iii) any information independently developed by the Recipient without reliance on the information disclosed hereunder by the Discloser. 2. Protection. For three (3) years after the date of disclosure, the Recipient shall keep all Confidential Information of the Discloser confidential, provided that trade secret information shall be maintained in confidence until the longer of (i) three years from the date of disclosure; or (ii) until the information is no longer a trade secret under applicable law. Except as provided in Section 3, the Recipient shall not, directly or indirectly, disclose the Confidential Information to any third party, and the Recipient shall take reasonable care to protect the Discloser’s Confidential Information. The Recipient shall not make any copies of any tangible documentation or materials provided hereunder, except to the extent necessary for the Purpose. The Recipient shall not use the Confidential Information of the Discloser for any reason other than for the Purpose. 3. Permitted Disclosures. The Recipient may only disclose the Confidential Information provided hereunder to its employees, agents, consultants and contractors who are directly involved in the Purpose and whom the Recipient has legally bound to comply with reasonable confidentiality obligations. The Recipient may also disclose Confidential Information to the extent it is obliged to do so under applicable laws, so long as it gives the Discloser reasonable notice to enable the Discloser to take protective steps. 4. Return. Upon request of the Discloser, the Recipient shall either (i) return all Confidential Information (including all copies) to the Discloser; or (ii) destroy all Confidential Information (including all copies) and provide written certification of their destruction to the Discloser 5. Term. This Agreement shall commence on the Effective Date and shall continue for three (3) years after the Effective Date. The provisions of this Agreement that are applicable to Confidential 1 circumstances occurring after termination or expiration shall survive such termination or expiration. 6. Warranty. Both parties represent and warrant that they have the right to engage in the discussions, and the Discloser represents that it has the right to disclose all information disclosed in the discussions. Notwithstanding the above, the Discloser does not make any representation or warranty as to the accuracy or completeness of the Confidential Information. 7. No Obligations. The Discloser is under no obligation to disclose Confidential Information. Nothing in this Agreement obligates either party (i) to offer for sale any product or service using or incorporating the Confidential Information; or (ii) to purchase any product or service from the other party. 8. Ownership. All rights in the Confidential Information disclosed remain the property of the Discloser. The Recipient does not acquire any intellectual property rights to the Discloser’s Confidential Information. 9. Entire Agreement. This Agreement constitutes the entire agreement between the parties related to the subject matter hereof, and it supersedes any and all prior agreements, understanding or other communications, whether written or oral, formal or informal, between them. No consent, waiver, alteration, amendment, or modification shall be binding unless in writing and signed by both parties. 10. Assignment. Neither party may assign its rights or delegate its duties or obligations under this Agreement without the prior written consent of the other party. 11. Governing Law and Jury Waiver. This Agreement shall be governed by, construed and enforced in accordance with the laws of the State of Delaware, USA. TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE PARTIES AGREE TO A BENCH TRIAL AND THAT THERE SHALL BE NO JURY IN ANY DISPUTES. 12. Injunctive Relief. Both parties acknowledge that a breach of this Agreement can cause the Discloser to suffer irreparable harm. IF ANY SUCH BREACH OCCURS OR IS THREATENED, THE DISCLOSER MAY SEEK INJUNCTIVE RELIEF, SPECIFIC PERFORMANCE AND OTHER EQUITABLE REMEDIES (IN ADDITION TO ANY AND ALL OTHER REMEDIES AT LAW) WITHOUT PROOF OF MONETARY DAMAGES OR THE INADEQUACY OF OTHER REMEDIES, AND THE RECIPIENTWAIVES ITS RIGHT TO ALL SUCH DEFENSES. 13. Limitation of Liability. The Discloser’s liability in any cause of action arising under, out of, or in relation to this Agreement, its negotiation, performance, breach or termination (collectively, “Cause of Action”) shall be limited to direct damages. The Discloser shall not be liable for any indirect,…

Text truncated - open the document above for the full version.

External Photos

Hardware Test-Regulatory T: 919-665-7878 639 Davis Drive F: 919-317-6210 Morrisville, NC 27560 USA www.sensus.com 1 525M External Photos

ID Label/Location Info

Figure 1: Sample Label Figure 2: Label Location

RF Exposure Info

DOCUMENT CONTROL NUMBER Non-Specific Radio Report Shell Rev. December 2017 © 2017 INTERTEK SENSUS METERING SYSTEMS INC. RF EXPOSURE REPORT SCOPE OF WORK RF EXPOSURE CALCULATIONS – 525M SMARTPOINT REPORT NUMBER 106310015ATL-010 ISSUE DATE REVISION DATE 20 February 2026 N/A PAGES 9 Non-Specific Radio Report Shell Rev. January 2025 Page 2 of 9 Sensus Metering Systems Inc. / 525M SmartPoint RF EXPOSURE REPORT Report Number: 106310015ATL-010 Project Number: G106310015 Report Issue Date: 20 February 2026 PMN: 525M Model / HVIN: 525M FCC ID: SDBWFL3 IC: 2220A-WFL3 Standards: FCC Title 47 CFR Parts 1.1310 RSS-102, Issue 6 Test Location Client Intertek 1950 Evergreen Blvd., Suite 100 Duluth, GA 30096 USA FCC Designation: US1046 CAB Designator: US0128 Sensus Metering Systems Inc. 639 Davis Drive Morrisville, NC 27560 USA Report prepared by: Report reviewed by Jeremy Pickens / Senior Staff Engineer Michael Carlson / Staff Engineer This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Report Number: 106310015ATL-010 Issued: 20 February 2025 Non-Specific Radio Report Shell Rev. January 2025 Page 3 of 9 Sensus Metering Systems Inc. / 525M SmartPoint Table of Contents 1 Introduction and Conclusion .............................................................................................................. 4 2 Evaluation Summary ........................................................................................................................... 4 3 Client Information ................................................................................................................................ 5 4 Description of Equipment Under Test and Variant Models ............................................................. 5 5 FCC Routine Evaluation Exemption Criteria ..................................................................................... 7 6 ISED Routine Evaluation Exemption Criteria .................................................................................... 8 7 Revision History ................................................................................................................................... 9 Intertek Report Number: 106310015ATL-010 Issued: 20 February 2025 Non-Specific Radio Report Shell Rev. January 2025 Page 4 of 9 Sensus Metering Systems Inc. / 525M SmartPoint 1 Introduction and Conclusion RF Exposure calculations were performed on the product constructed as described in Section 4. Information provided by the client including maximum output power, antenna gain(s), and minimum separation distance(s) was used to determine if the product under evaluation was exempt from routine evaluation. Any change in these stated values may invalidate these results. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product under evaluation is exempt from routine evaluation for each of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) evaluated. Intertek does not make any claims of compliance for samples or variants which were not evaluated. 2 Evaluation Summary Section Test full name Result 5 Routine Evaluation Exemption Criteria (FCC Title 47 CFR Part 1.1310) Compliant 6 ISED Routine Evaluation Exemption Criteria (RSS-102 Issue 6) Compliant Intertek Report Number: 106310015ATL-010 Issued: 20 February 2025 Non-Specific Radio Report Shell Rev. January 2025 Page 5 of 9 Sensus Metering Systems Inc. / 525M SmartPoint 3 Client Information This evaluation was performed at the request of: Client: Sensus Metering Systems Inc. 639 Davis Drive Morrisville, NC 27560 USA Contact: James Francisco Email: [email protected] 4 Description of Equipment Under Test and Variant Models Manufacturer: Sensus Metering Systems Inc. 639 Davis Drive Morrisville, NC 27560 USA Equipment Under Test Description Manufacturer Model Number (HVIN) Serial Number Transceiver Module Sensus Metering Systems Inc. 525M 125852710 1 125852716 2 1) KDS TCXO 2) Interquip TCXO Receive Date: 03 September 2025 Received Condition: Good Type: Production Description of Equipment Under Test The equipment under test was the 525M SmartPoint that incorporates a Sensus FLEXNET 900MHz transceiver, a sub-GHz 902-928MHz DTS transceiver, and a Cat M / NBIoT cellular modem. The device does not support simultaneous transmission among the radios. The SmartPoint ® 525M pit set module is a radio transceiver designed for use in submersible, pit set environments. With true two-way communication ability, it serves as a walk-by end point, drive-by end point, fixed-base end point or any combination of those. This versatility gives you highly flexible data collection options and simplifies both current operations and network evolution. Certification Purpose This test report is to support an original certification of the 525M SmartPoint which incorporates a licensed FlexNet radio, a CatM/NBIoT cellular modem, and an unlicensed 902-928MHz TFXv2 (DTS) radio. The radios all share the same antenna, and none can operate simultaneously. Equ…

Text truncated - open the document above for the full version.

Test Report

DOCUMENT CONTROL NUMBER Non-Specific Radio Report Shell Rev. January 2025 © 2025 INTERTEK SENSUS METERING SYSTEMS INC. TEST REPORT SCOPE OF WORK RADIO TESTING –525M SMARTPOINT REPORT NUMBER 106310015ATL-005 ISSUE DATE REVISED DATE 18 February 2026 N/A PAGES 27 RADIO TEST REPORT Report Number: 106310015ATL-005 Project Number: G106310015 Report Issue Date: 18 February 2026 PMN: 525M Model/HVIN: 525M FCC ID: SDBWFL3 IC: 2220A-WFL3 Standards: 47 CFR Part 15 Subpart C, 15.247 RSS-247, Issue 4 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024 RSS-GEN, Issue 5 Test Location Client Intertek 1950 Evergreen Blvd., Suite 100 Duluth, GA 30096 USA FCC Designation: US1046 ISED CAB Designator: US0128 ISO 17025 A2LA Accreditation: 1455.01 Sensus Metering Systems Inc. 639 Davis Drive Morrisville, NC 27560 USA Report prepared by Report reviewed by Jeremy Pickens / Senior Staff Engineer Michael Carlson / Staff Engineer This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Report Number: 106310015ATL-005 Issued: 18 February 2026 Non-Specific Radio Report Shell Rev. January 2025 Page 3 of 27 Sensus Metering Systems Inc. / 525M SmartPoint Table of Contents 1 Introduction and Conclusion .............................................................................................................. 4 2 Test Summary ...................................................................................................................................... 4 3 Client Information ................................................................................................................................ 5 4 Description of Equipment Under Test and Variant Models ............................................................. 5 5 Bandwidth ............................................................................................................................................. 8 6 Output Power ..................................................................................................................................... 10 7 Power Spectral Density ..................................................................................................................... 12 8 Conducted Spurious Emissions / Band Edge ................................................................................ 14 9 Radiated Spurious Emissions / Restricted Frequency Bands ...................................................... 20 10 Measurement Uncertainty ............................................................................................................. 26 11 Revision History ............................................................................................................................. 27 Intertek Report Number: 106310015ATL-005 Issued: 18 February 2026 Non-Specific Radio Report Shell Rev. January 2025 Page 4 of 27 Sensus Metering Systems Inc. / 525M SmartPoint 1 Introduction and Conclusion The tests indicated in Section 2 were performed on the product constructed as described in Section 4. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. Intertek does not make any claims of compliance for samples or variants which were not tested. 2 Test Summary Section Test Description Test Specification Result FCC ISED 5 Occupied and DTS Bandwidth 15.247(a)(2) RSS-247 S5.2(a) RSS-GEN S6.7 Compliant 6 Output Power 15.247(b)(3) RSS-247 S5.4(d) Compliant 7 Power Spectral Density 15.247(e) RSS-247 S5.2(b) Compliant 8 Conducted Spurious Emissions / Band Edge 15.247(d) RSS-247 S5.5 Compliant 9 E…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ray Britt(Senior Director, Global System Test)
[email protected]Fax: 919-317-6210

Technical Contact

Sensus a Xylem BrandRay Britt
[email protected]

637 Davis Dr · Morrisville, North Carolina, 27560 · United States

Test Firm

Intertek Testing Services NA Inc.Jeff Hiday
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.75 MHz - 914.75 MHz84.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is average conducted. This grant is valid only when the device is installed by the grantee or contractors employed by the grantee who are instructed to ensure that the end-user has no manual instructions to remove or install the device. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Co-located with FCC ID: SDBSNUSCM1.

Other Applications from Sensus Metering Systems Inc.

Command Link II Wireless Interface - FCC ID SDBCL202 - Sensus Metering Systems Inc.
SDBCL202

Command Link II Wireless Interface

Mar 09, 2026

Equipment Class

PCB - PCS Licensed Transmitter
SDBIDTB007

Stratus IQ+ Radio Module

Sep 28, 2023

Equipment Class

PCB - PCS Licensed Transmitter
Base Station Transceiver - FCC ID SDBM420V01 - Sensus Metering Systems Inc.
SDBM420V01

Base Station Transceiver

Jan 05, 2023

Equipment Class

PCB - PCS Licensed Transmitter
Base Station Transceiver - FCC ID SDBM420V00 - Sensus Metering Systems Inc.
SDBM420V00

Base Station Transceiver

Jan 05, 2023

Equipment Class

PCB - PCS Licensed Transmitter
SDBFLXI2102

Remote Telemetry Module

Apr 13, 2022

Equipment Class

PCB - PCS Licensed Transmitter