Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Rev1/26/2023 iHealthLabs,Inc. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:July22,2024 Ref:AttestationStatementsPart2.911(d)(7)Filing FCCID:SLR550BTBD ApplicantFRN:0022414882 iHealthLabs,Inc.(“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,iHealth Labs,Inc.isourdesignatedU.S.agentforserviceofprocessfortheabovereferencedFCC ID:SLR550BTBD iHealthLabs,Inc.acceptstomaintainanagentofserviceofprocessintheUnitedStatesfornolessthan oneyearaftereitherthegranteehaspermanentlyterminatedallmarketingandimportationofthe applicableequipmentwithintheU.S.,ortheconclusionofanyCommission-relatedadministrativeor judicialproceedinginvolvingtheequipment,whicheverislater. iHealthLabs,Inc.accepts,asofthedateofthefilingoftheapplication,theobligationofthedesignated U.S.agentforserviceofprocessfortheabovereferencedFCCID:SLR550BTBD DesignatedU.S.AgentInformation: Name:iHealthLabs,Inc. U.S.AgentFRN:0022414882 Address:880WMaudeAveSunnyvale,CA94085UnitedStates ContactPerson:MingCong Tel.:(855)816-7705 Email:[email protected] Sincerely, iHealthLabs,Inc.iHealthLabs,Inc. Applicantprintedname:JiChangyongU.S.Agentprintedname:MingCong Applicantsignature:U.S.Agentsignature:
Rev11/20/07 iHealthLabs,Inc. FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationofFCCID:SLR550BTBD PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName (BlockDiagram,Schematics,Operational Description) (BlockDiagram.pdf,Schematics.pdf, OperationalDescription.pdf) Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateoftheGrant forthisapplication. PursuanttoDA04-1705June15,2004oftheCommission’spublicnotice,wealsorequestthat theinformationattachedtothisapplicationbetemporarilyconfidentialfor180daysasoutlined below: ExhibitTypeFileName // Sincerely, Signature: printedname:MingCong Date:July15,2024
ReportNo.:EED32Q80512201Page 34 of 42 9PHOTOGRAPHSOFEUTConstructionalDetails ViewofProduct-01 ViewofProduct-02 ReportNo.:EED32Q80512201Page 35 of 42 ViewofProduct-03 ViewofProduct-04 ReportNo.:EED32Q80512201Page 36 of 42 ViewofProduct-05 ViewofProduct-06 ReportNo.:EED32Q80512201Page 37 of 42 ViewofProduct-07
ReportNo.:EED32Q80512201Page 37 of 42 ViewofProduct-08 ReportNo.:EED32Q80512201Page 38 of 42 ViewofProduct-09 ViewofProduct-10 ReportNo.:EED32Q80512201Page 39 of 42 ViewofProduct-11 ViewofProduct-12 ReportNo.:EED32Q80512201Page 40 of 42 ViewofProduct-13 ViewofProduct-14 ReportNo.:EED32Q80512201Page 41 of 42 ViewofProduct-15 ViewofProduct-16 ReportNo.:EED32Q80512201Page 42 of 42 ViewofProduct-17(MCUphoto) ViewofProduct-18 Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthis reportreferonlytothesample(s)tested.WithoutwrittenapprovalofCTI,thisreportcan’tbereproduced exceptinfull. ***EndofReport***
ReportNo.:EED32Q80512202Page1of7 RFExposureEvaluationReport Product:ConnectedBloodPressureMonitor Trademark:iHealth Model/Typereference:KN-550BT SerialNumber:N/A ReportNumber:EED32Q80512202 FCCID:SLR550BTBD DateofIssue:Jun.14,2024 TestStandards: 47CFRPart1.1307 47CFRPart1.1310 47CFRPart2.1091 47CFRPart2.1093 KDB447498D04InterimGeneralRF ExposureGuidancev01 Testresult:PASS Preparedfor: iHealthLabs,lnc. 880WMaudeAve,Sunnyvale,CA94085,UnitedStates Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: ZhenxiaWenFrazerLi Approvedby:Date:Jun.14,2024 AaronMa CheckNo.:4831190424 ReportNo.:EED32Q80512202Page2of7 1Version VersionNo.DateDescription 00Jun.14,2024Original ReportNo.:EED32Q80512202Page3of7 2Contents Page 1VERSION............................................................................................................................................................................2 2CONTENTS........................................................................................................................................................................3 3GENERALINFORMATION..............................................................................................................................................4 3.1C LIENT I NFORMATION .....................................................................................................................................4 3.2G ENERAL D ESCRIPTIONOF EUT....................................................................................................................4 3.3P RODUCT S PECIFICATIONSUBJECTIVETOTHISSTANDARD ..............................................................................4 3.4T EST L OCATION .............................................................................................................................................5 3.5D EVIATIONFROM S TANDARDS ........................................................................................................................5 3.6A BNORMALITIESFROM S TANDARD C ONDITIONS ...............................................................................................5 3.7O THER I NFORMATION R EQUESTEDBYTHE C USTOMER ....................................................................................5 4SAREVALUATION...........................................................................................................................................................6 4.1RFE XPOSURE C OMPLIANCE R EQUIREMENT ...................................................................................................6 4.1.1Limits.....................................................................................................................................................6 4.1.2TestProcedure.....................................................................................................................................6 4.1.3EUTRFExposureEvaluation...............................................................................................................7 ReportNo.:EED32Q80512202Page4of7 3GeneralInformation 3.1ClientInformation Applicant: iHealthLabs,lnc. AddressofApplicant: 880WMaudeAve,Sunnyvale,CA94085,UnitedStates Manufacturer: AndonHealthCo.,LTD AddressofManufacturer: No.3JinpingStreet,YaAnRoad,NankaiDistrict,Tianjin300190,China Factory: AndonHealthCo.,LTD AddressofFactory: No.3JinpingStreet,YaAnRoad,NankaiDistrict,Tianjin300190,China 3.2GeneralDescriptionofEUT ProductName:ConnectedBloodPressureMonitor ModelNo.(EUT):KN-550BT TradeMark: iHealth 3.3 ProductSpecificationsubjectivetothisstandard FrequencyRange:2402MHz~2480MHz ModulationType:GFSK TestPowerGrade:Default TestSoftwareofEUT:RFTest_0421_disableRTSDTR_boxed AntennaType: PCBAntenna AntennaGain: 0.01dBi SoftwareVersion: 303 HardwareVersion: 300 Bluetoothversion: 5.2 PowerSupply:Battery:DC1.5V*4 TestVoltage: DC6V SampleReceivedDate: May20,2024 SampletestedDate: May20,2024toMay23,2024 Remark: CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwas/wereprovided bytheapplicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32Q80512202Page5of7 3.4TestLocation Alltestswereperformedat: CentreTestingInternationalGroupCo.,Ltd BuildingC,HongweiIndustrialParkBlock70,Bao'anDistrict,Shenzhen,China Telephone:+86(0)75533683668Fax:+86(0)75533683385 Notestsweresub-contracted. FCCDesignationNo.:CN1164 3.5DeviationfromStandards None. 3.6AbnormalitiesfromStandardConditions None. 3.7OtherInformationRequestedbytheCustomer None. ReportNo.:EED32Q80512202Page6of7 4SAREvaluation 4.1RFExposureComplianceRequirement 4.1.1Limits TheSAR-basedexemptionformulaof§1.1307(b)(3)(i)(B),repeatedhereasFormula(B.2),appliesfor singlefixed,mobile,andportableRFsourceswithavailablemaximumtime-averagedpoweroreffective radiatedpower(ERP),whicheverisgreater,oflessthanorequaltothethresholdPth(mW). Thismethodshallonlybeusedatseparationdistancesfrom0.5cmto40cmandatfrequenciesfrom 0.3GHzto6GHz(inclusive).PthisgivenbyFormula andfisinGHz,distheseparationdistance(cm),andERP20cmisperFormula(B.1). The1mWBlanketExemptionof§1.1307(b)(3)(i)(A)appliesforsinglefixed,mobile,andportableRF sourceswithavailablemaximumtime-averagedpowerofnomorethan1mW,regardlessofseparation distance. 4.1.2TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. ReportNo.:EED32Q80512202Page7of7 4.1.3EUTRFExposureEvaluation ForStandalone: ForBluetoothLE: Frequency (MHz) Max. Conducted Outputpower (dBm) Antenna Gain(dBi) EIRP (dBm) ERP (dBm) ERP (mW) Limit (mW) Result 2480-1.690.01-1.68-3.830.4142.717PASS Note: ①EIRP=conductedpower+antennagain; ②ERP=EIRP-2.15; ③EIRP(dBm)=Fieldstrengthofthefundamentalsignal(dBuV/m@3m)–95.23; ④ERP(mW)=10^ (ERP(dBm)/10); ⑤Theestimationdistanceis0.5cm; ⑥ThetestdatapleaserefertothereportofEED32PQ80512201andonlytheworstcasedataw…
Text truncated - open the document above for the full version.
ReportNo.:EED32Q80512201Page 1 of 42 TESTREPORT Product:ConnectedBloodPressure Monitor Trademark:iHealth Model/Typereference:KN-550BT SerialNumber:N/A ReportNumber:EED32Q80512201 FCCID:SLR550BTBD DateofIssue:Jun.14,2024 TestStandards: 47CFRPart15SubpartC Testresult:PASS Preparedfor: iHealthLabs,lnc. 880WMaudeAve,Sunnyvale,CA94085,UnitedStates Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: ZhenxiaWenFrazerLi Approvedby:Date:Jun.14,2024 AaronMa CheckNo.:4831190424 ReportNo.:EED32Q80512201Page 2 of 42 1Content 1CONTENT............................................................................................................................................................................2 2VERSION.............................................................................................................................................................................3 3TESTSUMMARY...............................................................................................................................................................4 4GENERALINFORMATION...............................................................................................................................................5 4.1C LIENT I NFORMATION ....................................................................................................................................................5 4.2G ENERAL D ESCRIPTIONOF EUT.................................................................................................................................5 4.3T EST C ONFIGURATION ..................................................................................................................................................6 4.4T EST E NVIRONMENT .....................................................................................................................................................7 4.5D ESCRIPTIONOF S UPPORT U NITS ...............................................................................................................................7 4.6T EST L OCATION .............................................................................................................................................................7 4.7M EASUREMENT U NCERTAINTY (95% CONFIDENCELEVELS , K =2).............................................................................8 5EQUIPMENTLIST..............................................................................................................................................................9 6TESTRESULTSANDMEASUREMENTDATA.........................................................................................................12 6.1A NTENNA R EQUIREMENT ............................................................................................................................................12 6.2C ONDUCTED E MISSIONS .............................................................................................................................................13 6.3M AXIMUM C ONDUCTED O UTPUT P OWER ..................................................................................................................16 6.4DTSB ANDWIDTH ........................................................................................................................................................17 6.5M AXIMUM P OWER S PECTRAL D ENSITY .....................................................................................................................18 6.6B AND E DGEMEASUREMENTSAND C ONDUCTED S PURIOUS E MISSION ...................................................................19 6.7R ADIATED S PURIOUS E MISSION &R ESTRICTEDBANDS ...........................................................................................20 7APPENDIXBLUETOOTHLE.........................................................................................................................................31 8PHOTOGRAPHSOFTESTSETUP..............................................................................................................................32 9PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS.....................................................................................34 ReportNo.:EED32Q80512201Page 3 of 42 2Version VersionNo.DateDescription 00Jun.14,2024Original ReportNo.:EED32Q80512201Page 4 of 42 3TestSummary TestItemTestRequirementResult AntennaRequirement 47CFRPart15SubpartCSection 15.203/15.247(c) PASS ACPowerLineConducted Emission 47CFRPart15SubpartCSection 15.207 PASS DTSBandwidth 47CFRPart15SubpartCSection 15.247(a)(2) PASS MaximumConductedOutput Power 47CFRPart15SubpartCSection 15.247(b)(3) PASS MaximumPowerSpectral Density 47CFRPart15SubpartCSection15.247(e)PASS BandEdgeMeasurements 47CFRPart15SubpartCSection 15.247(d) PASS ConductedSpurious Emissions 47CFRPart15SubpartCSection 15.247(d) PASS RadiatedSpuriousEmission& Restrictedbands 47CFRPart15SubpartCSection 15.205/15.209 PASS Remark: CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwereprovidedbythe applicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32Q80512201Page 5 of 42 4GeneralInformation 4.1ClientInformation Applicant:iHealthLabs,lnc. AddressofApplicant:880WMaudeAve,Sunnyvale,CA94085,UnitedStates Manufacturer:AndonHealthCo.,LTD AddressofManufacturer:No.3JinpingStreet,YaAnRoad,NankaiDistrict,Tianjin300190,China Factory:AndonHealthCo.,LTD AddressofFactory:No.3JinpingStreet,YaAnRoad,NankaiDistrict,Tianjin300190,China 4.2GeneralDescriptionofEUT ProductName: ConnectedBloodPressureMonitor ModelNo.: KN-550BT Trademark: iHealth ProductType: MobilePortableFixLocation OperationFrequency: 2402MHz~2480MHz ModulationType: GFSK TransferRate: 1Mbps2Mbps NumberofChannel: 40 AntennaType:PCBAntenna AntennaGain:0.01dBi SoftwareVersion: 303 HardwareVersion: 300 Bluetoothversion: 5.…
Text truncated - open the document above for the full version.
ReportNo.:EED32Q80512201Page 1 of 24 Appendix:BluetoothLE ReportNo.:EED32Q80512201Page 2 of 24 Contents DutyCycle..................................................................................................................................................................................................3 MaximumPeakConductedOutputPower..................................................................................................................................................6 -6dBBandwidth..........................................................................................................................................................................................9 OccupiedChannelBandwidth..................................................................................................................................................................12 MaximumPowerSpectralDensityLevel..................................................................................................................................................15 BandEdge................................................................................................................................................................................................18 ConductedRFSpuriousEmission............................................................................................................................................................21 ReportNo.:EED32Q80512201Page 3 of 24 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTBLE1M2402Ant134.614.612.52 NVNTBLE1M2440Ant134.614.612.52 NVNTBLE1M2480Ant134.614.612.52 ReportNo.:EED32Q80512201Page 4 of 24 TestGraphs DutyCycleNVNTBLE1M2402MHzAnt1 DutyCycleNVNTBLE1M2440MHzAnt1 ReportNo.:EED32Q80512201Page 5 of 24 DutyCycleNVNTBLE1M2480MHzAnt1 ReportNo.:EED32Q80512201Page 6 of 24 MaximumPeakConductedOutputPower ConditionModeFrequency (MHz) AntennaConductedPower (dBm) Limit (dBm) Verdict NVNTBLE1M2402Ant1-2.4930Pass NVNTBLE1M2440Ant1-2.1430Pass NVNTBLE1M2480Ant1-1.6930Pass ReportNo.:EED32Q80512201Page 7 of 24 TestGraphs PeakPowerNVNTBLE1M2402MHzAnt1 PeakPowerNVNTBLE1M2440MHzAnt1 ReportNo.:EED32Q80512201Page 8 of 24 PeakPowerNVNTBLE1M2480MHzAnt1 ReportNo.:EED32Q80512201Page 9 of 24 -6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTBLE1M2402Ant10.670.5Pass NVNTBLE1M2440Ant10.6780.5Pass NVNTBLE1M2480Ant10.6740.5Pass ReportNo.:EED32Q80512201Page 10 of 24 TestGraphs -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2440MHzAnt1 ReportNo.:EED32Q80512201Page 11 of 24 -6dBBandwidthNVNTBLE1M2480MHzAnt1 ReportNo.:EED32Q80512201Page 12 of 24 OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTBLE1M2402Ant11.018 NVNTBLE1M2440Ant11.023 NVNTBLE1M2480Ant11.033 ReportNo.:EED32Q80512201Page 13 of 24 TestGraphs OBWNVNTBLE1M2402MHzAnt1 OBWNVNTBLE1M2440MHzAnt1 ReportNo.:EED32Q80512201Page 14 of 24 OBWNVNTBLE1M2480MHzAnt1 ReportNo.:EED32Q80512201Page 15 of 24 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/3kHz) DutyFactor (dB) TotalPSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNTBLE1M2402Ant1-16.740-16.748Pass NVNTBLE1M2440Ant1-16.80-16.88Pass NVNTBLE1M2480Ant1-16.160-16.168Pass ReportNo.:EED32Q80512201Page 16 of 24 TestGraphs PSDNVNTBLE1M2402MHzAnt1 PSDNVNTBLE1M2440MHzAnt1 ReportNo.:EED32Q80512201Page 17 of 24 PSDNVNTBLE1M2480MHzAnt1 ReportNo.:EED32Q80512201Page 18 of 24 BandEdge ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-42.59-20Pass NVNTBLE1M2480Ant1-43.93-20Pass ReportNo.:EED32Q80512201Page 19 of 24 TestGraphs BandEdgeNVNTBLE1M2402MHzAnt1Ref BandEdgeNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32Q80512201Page 20 of 24 BandEdgeNVNTBLE1M2480MHzAnt1Ref BandEdgeNVNTBLE1M2480MHzAnt1Emission ReportNo.:EED32Q80512201Page 21 of 24 ConductedRFSpuriousEmission ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-31.76-20Pass NVNTBLE1M2440Ant1-33.04-20Pass NVNTBLE1M2480Ant1-34.57-20Pass ReportNo.:EED32Q80512201Page 22 of 24 TestGraphs Tx.SpuriousNVNTBLE1M2402MHzAnt1Ref Tx.SpuriousNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32Q80512201Page 23 of 24 Tx.SpuriousNVNTBLE1M2440MHzAnt1Ref Tx.SpuriousNVNTBLE1M2440MHzAnt1Emission ReportNo.:EED32Q80512201Page 24 of 24 Tx.SpuriousNVNTBLE1M2480MHzAnt1Ref Tx.SpuriousNVNTBLE1M2480MHzAnt1Emission ***EndofReport***
Page 1 of15 Test Report Verified code: Report No.: E202311296618-1 Customer: ANDON HEALTH CO.,LTD. Address: No.3 Jin Ping Street,Ya An Road,Nankai District,Tianjin 300190, China Sample Name: Onboard Antenna Sample Model: ANT-OB13077 Receive Sample Date: Dec.11,2023 Test Date: Dec.13,2023 ~ Dec.13,2023 Reference Document: ANSI IEEE 149-2021 Part 7, Part 8, Part 10 Test Result: Refer to the following report Prepared by: Reviewed by: Approved by: Xu Xingqiu Wang Guodong Zhao Zetian GRG METROLOGY & TEST GROUP CO., LTD. Issued Date: GRG METROLOGY & TEST GROUP CO., LTD. Address: No.163,Pingyun Road, West of Huangpu Avenue, Guangzhou, Guangdong, China Tel:(+86)400-602-0999 FAX:(+86)020-38698685 Web:http://www.grgtest.com 812480 2023-12-15 Report No.: E202311296618-1 Page 2 of15 Statement 1. The report is invalid without "special seal for inspection and testing"; some copies are invalid; The report is invalid if it is altered or missing; The report is invalid without the signature of the person who prepared, reviewed and approved it. 2. The sample information is provided by the client and responsible for its authenticity; The content of the report is only valid for the samples sent this time. 3. When there are reports in both Chinese and English, the Chinese version will prevail when the language problems are inconsistent. 4. If there is any objection concerning the report, please inform us within 15 days from the date of receiving the report. 5. Without the agreement of the laboratory, the client is not authorized to use the test results for unapproved propaganda. ------------ The following blanks ------------ Report No.: E202311296618-1 Page 3 of15 TABLE OF CONTENTS 1. TEST RESULT SUMMARY ...................................................................................................................... 5 2. GENERAL DESCRIPTION OF EUT ......................................................................................................... 6 2.1 APPLICANT INFORMATION ...................................................................................................................... 6 2.2 MANUFACTURER ........................................................................................................................................ 6 2.3 FACTORY ...................................................................................................................................................... 6 2.4 BASIC DESCRIPTION OF EUT ................................................................................................................... 6 2.5 TEST SCENE .................................................................................................................................................. 6 2.6 SAMPLE WORK DESCRIPTION ................................................................................................................. 6 2.7 ASSISTIVE DEVICE INFORMATION......................................................................................................... 7 2.8 SAMPLE CONNECTION DIAGRAM .......................................................................................................... 7 3. LABORATORY .......................................................................................................................................... 8 4. MEASUREMENT UNCERTAINTY .......................................................................................................... 9 5. EQUIPMENT AND TOOLS USED DURING TEST .............................................................................. 10 6. ANTENNA RADIATION PERFORMANCE MEASUREMENT ........................................................... 11 6.1 LIMITS ......................................................................................................................................................... 11 6.2 TEST PROCEDURE ..................................................................................................................................... 11 6.3 TEST RESULTS ........................................................................................................................................... 12 6.4 2D ANTENNA PATTERN ........................................................................................................................... 12 6.5 3D ANTENNA PATTERN ........................................................................................................................... 13 APPENDIX A TEST PHOTOS OF THE EUT ................................................................................................ 15 APPENDIX B PHOTOGRAPH OF THE EUT ............................................................................................... 15 ------------ The following blanks ------------ Report No.: E202311296618-1 Page 4 of15 REPORT ISSUED HISTORY Report Version Report No. Description Compile Date 1.0 E202311296618-1 Original Issue 2023-12-15 ------------ The following blanks ------------ Report No.: E202311296618-1 Page 5 of15 1. TEST RESULT SUMMARY Test Item Test Frequency Test Method Test Scene Test Result Gain 2400MHz~2500MHz ANSI IEEE 149-2021 Part 8 scene 1 / 1) Efficiency 2400MHz~2500MHz ANSI IEEE 149-2021 Part 10 scene 1 / 1) 2D Antenna pattern 2400MHz~2500MHz ANSI IEEE 149-2021 Part 7 scene 1 / 1) 3D Antenna pattern 2400MHz~2500MHz ANSI IEEE 149-2021 Part 7 scene 1 / 1) Note 1):Customer-defined test, test results do not make judgment. ------------ The following blanks ------------ . Report No.: E202311296618-1 Page 6 of15 2. GENERAL DESCRIPTION OF EUT 2.1 APPLICANT INFORMATION Name: ANDON HEALTH CO.,LTD. Address: No.3 Jin Ping Street,Ya An Road,Nankai District,Tianjin 300190, China 2.2 MANUFACTURER Name: ANDON HEALTH CO.,LTD. Address: No.3 Jin Ping Street,Ya An Road,Nankai District,Tianjin 300190, China 2.3 FACTORY Name: ANDON HEALTH CO.,LTD. Address: No.3 Jin Ping Street,Ya An Road,Nankai District,Tianjin 300190, China 2.4 BASIC DESCRIPTION OF EUT Product Name: O…
Text truncated - open the document above for the full version.
ReportNo.:EED32Q80512201Page 32 of 42 8PHOTOGRAPHSOFTESTSETUP RadiatedspuriousemissionTestSetup-1 (Below1GHz) RadiatedspuriousemissionTestSetup-2( Above1GHz) ReportNo.:EED32Q80512201Page 33 of 42 RadiatedspuriousemissionTestSetup-3( Above1GHz) Thereareabsorbingmaterialsundertheground. ConductedEmissionsTestSetup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 700.00 µW |
iHealth Jurni Connected Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission SystemWireless Body Composition Scale
Equipment Class
DTS - Digital Transmission System
Wireless Smart Glucose Meter
Equipment Class
DTS - Digital Transmission System
Wireless No-Touch Forehead Thermometer
Equipment Class
DTS - Digital Transmission System
Vista
Equipment Class
DTS - Digital Transmission System