iHealthยฎ Wireless Smart Gluco-Monitoring System๏ผBG1S๏ผ OWNERโS MANUAL For in vitro diagnostic use only Read instructions before use for self-testing Table of Contents INTRODUCTION 1 IMPORTANT SAFETY INFORMATION1 Intended use 1 Limitations of use 1 Important safety instructions2 YOUR NEW WIRELESS SMART GLUCOSE METER3 Contents of the iHealth Wireless Smart Gluco-Monitoring System (BG1S)3 Mobile device compatibility6 TEST PRINCIPLE 6 CONTROL SOLUTION TESTS6 Warning and precautions6 Test procedures 7 Expected values 7 Important 8 BLOOD GLUCOSE TEST8 Important information8 First time setup instructions9 About the online test9 CLEANING AND DISINFECTION12 INFORMATION ABOUT ALTERNATE SITE TESTING (AST)14 What is Alternate Site Testing?14 What is the advantage of Alternate Site Testing?14 When should you use Alternate Site Testing?14 MAINTENANCE AND TROUBLESHOOTING15 Maintenance and storage of your iHealth Wireless Smart Glucose Meter15 System troubleshooting15 Signs of potential physical and performance deterioration16 iHealth WIRELESS SMART GLUCO-MONITORING SYSTEM SPECIFICATIONS16 Technical specifications16 Important information required by the FCC17 Electromagnetic compatibility information18 Warra nty information19 EXPLANATIO N OF SYMBOLS21 1 INTRODUCTION Thank you for purchasing the iHealth Wireless Smart Gluco-Monitoring System (BG1S). This manual provides important information to help you to use the system properly. Before using this product, please read the Ownerโs Manual thoroughly. If you have questions regarding this product, please visit www.iHealthlabs.com, contact your place of purchase, or call iHealth Labs Customer Service at 1-855- 816-7705 (Mon.-Fri. 8:30AM-5:30PM PST, Monday to Friday except holidays) If you have questions or need assistance outside the operational hours and days, please contact your healthcare provider. IMPORTANT SAFETY INFORMATION Intended use The iHealth Wireless smart Gluco-Monitoring System (BG1S) consists of the iHealth Wireless Smart Glucose Meter (BG1S), iHealth Test Strips (EGS-2003), and the iHealth App mobile application. The iHealth Wireless Smart Gluco-Monitoring System i s intended to be used for the quantitative measurement of glucose (sugar) in fresh capillary whole blood samples drawn from the fingertip, palm, forearm, upper arm, calf, or thigh. The iHealth Wireless Smart Gluco-Monitoring System is intended to be used by a s ingle person and should not be shared. The iHealth Wireless Smart Gluco-Monitoring System is intended for self-testing outside the body (in vitro diagnostic use) by people with diabetes at home as an aid to monitor the effectiveness of diabetes control. The iHealth Wireless Smart Gluco-Monitoring System should not be used for the diagnosis of or screening of diabetes or for neonatal use. Alternative site testing should be done only during steady-state times (when glucose is not changing rapidly). Limitations of use The meter and lancing device are for single patient use. Do not share them with anyone including other family members! Do not use on multiple patients! The iHealth system is not intended for use on neonates, nor for screening or diagnosis. Not for use on critically ill patients. This device is not for use on people who are severely dehydrated, on people who are severely hypotensive, or people who are in shock, consult your healthcare professional immediately when this happens. Use only fresh capillary whole blood samples to test your blood glucose. Very low or very high red blood cell count (hematocrit) can lead to incorrect test results. If you do not know your hematocrit level, please consult your healthcare provider. For self-testing only. Do not perform (Alternative Site Testing) AST if you think your glucose is low, you are unaware that you might have hypoglycemia, you are testing for hyperglycemia, your AST results do not match the way you feel, your routine glucose results fluctuate often. Do not use AST results to calibrate a continuous glucose monitor (CGM) or for insulin dosing calculations. AST should only be used during times when blood sugar is not fluctuating rapidly, 2 i.e. Within 2 hours of eating, exercising or taking medication. If you take acetaminophen or acetaminophen containing medications (Tylenol, certain cold and flu remedies, or certain prescription drugs) this medication might affect the reliability of your blood glucose results (blood concentrations >5 mg/dL). If you are unsure, then ask your healthcare professional. Certain conditions may cause your blood level of uric acid to rise. These conditions include gout or kidney disease. You should know that if your blood level of uric acid is high (โฅ10 mg/dL) then your blood glucose results may be not reliable. If you are unsure, then ask your healthcare professional. Vitamin C (Ascorbic acid (>4 mg/dL) naturally in your blood or from food or taking Vitamin C supplements might cause inaccurate blood glucose results when using this blood glucose monitoring system. Do not use this device during or shortly after receiving xylose absorption therapy since xylose may cause inaccurate blood glucose results. This device is not intended for use in healthcare or assisted-use settings such as hospitals, physician offices, or long-term care facilities because it has not been cleared by FDA for use in these settings, including for routine assisted testing or as part of glycemic control procedures. Use of this device on multiple patients may lead to transmission of Human Immunodeficiency Virus (HIV), Hepatitis C Virus(HCV), Hepatitis B Virus(HBV), or other bloodborne pathogens. For over-the-counter use. Important safety instructions Please read the following information carefully before using the iHealth Wireless Smart Gluco-Monitoring System (BG1S). Always keep these instructions in a safe place for reference. Do not change your therapy based on a test result that does not match what you feel or if you believe that your test result could be incorrect. Ifโฆ
Text truncated - open the document above for the full version.
iHealth Labs, Inc. Date: 2020-12-14 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 To Whom It May Concern: The iHealth Labs, Inc., the undersigned, hereby authorizes Miss. Wendy Zhan from Shenzhen Morlab Communications Technology Co., Ltd., to act on the behalf of the company name solely in matters relating to the application for an FCC equipment authorization for FCC ID: SLRBG1S including the signing of documents in connection with this Application. Necessary acts carried out Shenzhen Morlab Communications Technology Co., Ltd. on our behalf of the iHealth Labs, Inc. in connection with the Application shall have the same effect as acts of the iHealth Labs, Inc.. iHealth Labs, Inc. also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Thank you for your attention to this matter. Yours Sincerely,
iHealth Labs, Inc. Date: 2020-12-14 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 Re: Request of Confidentiality for FCC ID: SLRBG1S To Whom it may concern: Pursuant to sections 0.457 and 0.459 of Commissionโs Rules(CFR 47), and Section 552(b)(4) of the Freedom of Information Act, iHealth Labs, Inc. hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA04-1705. This provision will give iHealth Labs, Inc. temporary confidentiality of commercially sensitive information prior to product release. The requested Permanent and Short-Term Confidential exhibits are listed as follows: PERMANENT AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description PERMANENT 1 Block Diagram 2 Operational Description 3 Schematics 4 BOM SHORT-TERM 5 External Photos 6 Internal Photos 7 Test-Setup Photos 8 User Manual The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application.
FCC ID:SLRBG1S, IC:10913A-BG1S External Photos 1. EUT front view 2. EUT rear view 3. EUT left side view 4. EUT right side view 5. EUT top view 6. EUT bottom view
1. Label 2. Label location CAN ICES-003(B)/NMB-003(B) IC: 10913A-BG1S FCC ID: SLRBG1S
FCC ID:SLRBG1S, IC:10913A-BG1S Internal Photos 1. EUT uncover view 2. Antenna view Bluetooth Antenna
NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 8 REPORT No.๏ผSZ20100096S01 RF EXPOSURE EXEMPT REPORT APPLICANT : iHealth Labs, Inc. PRODUCT NAME : Wireless Smart Glucose Meter MODEL NAME :BG1S BRAND NAME : iHealth FCC ID : SLRBG1S STANDARD(S) : 47CFR 2.1093 KDB 447498 RECEIPT DATE : 2020-10-14 TEST DATE :2020-10-28 to 2020-11-09 ISSUE DATE :2020-12-24 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Peng Huarui (Supervisor) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 8 REPORT No.๏ผSZ20100096S01 DIRECTORY 1. Technical Information โโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโ 3 1.1 Applicant and Manufacturer Information โโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโ 3 1.2 Equipment Under Test (EUT) Description โโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโ 3 1.3 Applied Reference Documents โโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโ 4 2. Device Category and RF Exposure Limit โโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโ 5 3. RF Output Power โโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโ 6 4. RF Exposure Evaluation โโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโ 7 Annex A Testing Laboratory Information โโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโโ 8 Change History Version Date Reason for change 1.0 2020-12-24 First edition MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 8 REPORT No.๏ผSZ20100096S01 1. Technical Information Note: Provide by applicant. 1.1 Applicant and Manufacturer Information Applicant: iHealth Labs, Inc. Applicant Address: 120 San Lucar Ct., Sunnyvale, CA 94086, USA Manufacturer: Andon Health Co., LTD. Manufacturer Address: No. 3 Jinping Street, Ya An Road, Nankai District, Tianjin 300190, China 1.2 Equipment Under Test (EUT) Description Product Name: Wireless Smart Glucose Meter Serial No.: (N/A, marked #1 by test site) Hardware Version: BG1S-NFMP01 V1.x Software Version: V1 Equipment Type: Bluetooth LE Bluetooth Version: 4.2 Frequency Range: 2402MHz-2480MHz Modulation Type: GFSK(1Mbps) Antenna Type: Chip Antenna Antenna Gain: 3.0dBi MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 8 REPORT No.๏ผSZ20100096S01 1.3 Applied Reference Documents Leading reference documents for testing: No. Identity Document Title Method determination /Remark 1 47 CFRยง2.1093 Radio Frequency Radiation Exposure Evaluation: portable devices No deviation 2 KDB 447498 D01v06 General RF Exposure Guidance No deviation Note 1: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 2: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% risk level. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 5 of 8 REPORT No.๏ผSZ20100096S01 2. Device Category and RF Exposure Limit Per user manual, this device is a Wireless Smart Glucose Meter. Based on 47CFR 2.1093, this device belongs to portable device category with General Population/Uncontrolled exposure. Portable Devices: 47CFR 2.1093(b) For purposes of this section, a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. General Population/Uncontrolled Exposure: 47CFR 2.1093(d) (2) Limits for General Population/Uncontrolled exposure: 0.08 W/kg as averaged over the whole-body and spatial peak SAR not exceeding 1.6 W/kg as averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the hands, wrists, feet and ankles where the spatial peak SAR shall not exceed 4 W/kg, as averaged over any 10 grams of tissue (defined as a tissue volume in the shape of a cube). General Population/Uncontrolled limits apply when the general public may be exposed, or when persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or do not exercise control over their exposure. Warning labels placed on consumer devices such as cellular telephones will not be sufficient reason to allow these devices to be evaluated subject to โฆ
Text truncated - open the document above for the full version.
NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 39 REPORT No.๏ผSZ20100096W01 TEST REPORT APPLICANT : iHealth Labs, Inc. PRODUCT NAME : Wireless Smart Glucose Meter MODEL NAME :BG1S BRAND NAME : iHealth FCC ID : SLRBG1S STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2020-10-14 TEST DATE :2020-10-28 to 2020-11-09 ISSUE DATE :2020-12-24 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Peng Huarui (Supervisor) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 39 REPORT No.๏ผSZ20100096W01 DIRECTORY 1. Technical Information ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 3 1.1. Applicant and Manufacturer Information ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 3 1.2. Equipment Under Test (EUT) Description ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 3 1.3. The Channel Number and Frequency ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 4 1.4. Test Standards and Results ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 5 1.5. Environmental Conditions ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 6 2. 47 CFR Part 15C Requirements ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 7 2.1. Antenna Requirement ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 7 2.2. Duty Cycle of Test Signal ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 8 2.3. Maximum Peak Conducted Output Power ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 9 2.4. Maximum Average Conducted Output Power ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 12 2.5. 6 dB Bandwidth ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 13 2.6. Conducted Spurious Emissions and Band Edge ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 16 2.7. Power Spectral Density (PSD) ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 20 2.8. Conducted Emission ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 23 2.9. Restricted Frequency Bands ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 25 2.10. Radiated Emission ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 29 Annex A Test Uncertainty ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 36 Annex B Testing Laboratory Information ๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊๊ 37 Change History Version Date Reason for change 1.0 2020-12-24 First edition MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 39 REPORT No.๏ผSZ20100096W01 1. Technical Information Note: Provide by applicant. 1.1. Applicant and Manufacturer Information Applicant: iHealth Labs, Inc. Applicant Address: 120 San Lucar Ct., Sunnyvale, CA 94086, USA Manufacturer: Andon Health Co., LTD. Manufacturer Address: No. 3 Jinping Street, Ya An Road, Nankai District, Tianjin 300190, China 1.2. Equipment Under Test (EUT) Description Product Name: Wireless Smart Glucose Meter Serial No.: (N/A, marked #1 by test site) Hardware Version: BG1S-NFMP01 V1.x Software Version: V1 Equipment Type: Bluetooth LE Bluetooth Version: 4.2 Modulation Type: GFSK Data Rate: 1Mbps Operating Frequency Range: 2402MHz-2480MHz Antenna Type: Chip Antenna Antenna Gain: 3.0dBi Accessory Information: Battery Brand Name: Panasonic Model No.: CR2032 Serial No.: (N/A, marked #1 by test site) Capacity: 220mAh Rated Voltage: 3. 0V Charge Limit: N/A Manufacturer: Panasonic Note 1: We use the dedicated software to control the EUT continuous transmission. Note 2: For a more detailed description, please refer to Specification or Userโs Manual supplied by the applicant and/or manufacturer. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 39 REPORT No.๏ผSZ20100096W01 1.3. The Channel Number and Frequency Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 0 2402 10 2422 20 2442 30 2462 1 2404 11 2424 21 2444 31 2464 2 2406 12 2426 22 2446 32 2466 3 2408 13 2428 23 2448 33 2468 4 2410 14 2430 24 2450 34 2470 5 2412 15 2432 25 2452 35 2472 6 2414 16 2434 26 2454 36 2474 7 2416 17 2436 27 2456 37 2476 8 2418 18 2438 28 2458 38 2478 9 2420 19 2440 29 2460 39 2480 Note 1: The black bold channels were selected for test. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 5 of 39 REPORT No.๏ผSZ20100096W01 1.4. Test Standards and Results The objective of the report is to pโฆ
Text truncated - open the document above for the full version.
FCC ID:SLRBG1S, IC:10913A-BG1S Test Setup Photos 1. Radiated emission (9KHz-30MHz) 2. Radiated emission (30MHz-1GHz) 3. Radiated emission (above 1GHz) 4. RF measurement setup (Bluetooth LE)
FL.1, Building A, FeiYang Science Park, ยท ShenZhen ยท China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 700.00 ยตW |
iHealth Jurni Connected Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission SystemWireless Body Composition Scale
Equipment Class
DTS - Digital Transmission System
Connected Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System
Wireless No-Touch Forehead Thermometer
Equipment Class
DTS - Digital Transmission System
Vista
Equipment Class
DTS - Digital Transmission System