Mr. Butler Company, 5402 Westerham, Fulshear, TX. 77441 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: SMK0112601 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Short Term Confidentiality Request: 2715UT6 ExternalPhotos.pdf 2715UT6 InternalPhotos.pdf 2715UT6 teststp.jpg 2715UT6 UserManual.pdf Permanent Confidentiality Request: 2715UT6 BlockDiagram.pdf 2715UT6 Operational Desc.pdf 2715UT6 Schematic.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Mark Kilbourne President – Mr. Butler Company
MR. BUTLER COMPANY FCC ID: SMK0112601 EXTERNAL PHOTOS
Mr. Butler Company, 5402 Westerham, Fulshear, TX. 77441 To: Sharon Hoffman Timco Engineering From: Mark Kilbourne President – Mr. Butler Company The following is a label description that will me molded into the transmitter: With any questions, please contact Mark Kilbourne at 713-443-1548 Sincerely, Mark Kilbourne FCC ID: SMK0112601
MR. BUTLER COMPANY FCC ID: SMK0112601 INTERNAL PHOTOS
FCC TEST REPORT PART 15.231 APPLICANT MR. BUTLER COMPANY ADDRESS 2634 YORKTOWN # 392 HOUSTON TX 77056 USA FCC ID SMK0112601 PRODUCT DESCRIPTION TRANSMITTER DATE SAMPLE RECEIVED 9/25/2006 DATE TESTED 9/27/2006 TESTED BY JOSEPH SCOGLIO APPROVED BY MARIO DE ARANZETA TIMCO REPORT NO. M\Mr._Butler_Co\2715UT6\2715UT6TestReport.doc TEST RESULTS PASS FAIL TOTAL PAGES THE ATTACHED REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL WITHOUT THE WRITTEN APPROVAL OF TIMCO ENGINEERING, INC. 849 NW STATE ROAD 45 NEWBERRY, FL 32669 USA PH: 888.472.2424 OR 352.472.5500 FAX: 352.472.2030 EMAIL: [email protected] HTTP://WWW.TIMCOENGR.COM APPLICANT: MR. BUTLER COMPANY FCC ID: SMK0112601 REPORT: M\Mr._Butler_Co\2715UT6\2715UT6TestReport.doc Page 2 of 14 TABLE OF CONTENTS GENERAL INFORMATION......................................................... 3 COMPLIANCE WITH PART 15.231(a)........................................... 4 EMC EQUIPMENT LIST.......................................................... 5 TEST PROCEDURE............................................................ 6 RADIATION INTERFERENCE................................................... 7 CALCULATION OF DUTY CYCLE................................................ 9 OCCUPIED BANDWIDTH....................................................... 13 APPLICANT: MR. BUTLER COMPANY FCC ID: SMK0112601 REPORT: M\Mr._Butler_Co\2715UT6\2715UT6TestReport.doc Page 3 of 14 GENERAL INFORMATION EUT Specification The test results relate only to the items tested. FCC ID SMK0112601 Product Description TRANSMITTER Operating Frequency 433.92 MHz Prototype Pre-Production Test Item Production Fixed Mobile Type of Equipment Portable Test standards FCC Part 15, Subpart C, & ANSI C63.4 – 2003 Modification to the DUT No modification were made. Test exercise (e.g software description, test signal, etc.) The EUT was set in continuous transmit mode of operation. Test Facility All tests were carried out at Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669. Receiver The receiver portion of this system has been tested and meets all of the FCC requirements per FCC rules Part 15.109. A report was issued and a copy of this report is available upon request. APPLICANT: MR. BUTLER COMPANY FCC ID: SMK0112601 REPORT: M\Mr._Butler_Co\2715UT6\2715UT6TestReport.doc Page 4 of 14 COMPLIANCE WITH PART 15.231(a) Part 15.231(a): • Continuous operation: Yes__ No__x_ • Control signal only: Yes_X__ No___ • Data transmission with a control signal Yes___ No_X__N/A___ Description of control signal: UNLOCKS DOOR(notes: indicate whether such info is included in supporting exhibit such as operation description page xx) Part 15.231(a)(1): • Manually operated device: Yes_X__ No___ • Does it meet the 5s deactivation requirement after the switch is being released: Yes_X__ No___ Description: _______________(notes: a plot showing the pulse train does not necessarily constitute an objective evidence of compliance with the deactivation requirement. A plot should be accompanied by an explanation and/or statement of compliance, if not otherwise clearly stated in supporting documentation e.g. operation description page xx) Part 15.231(a)(2): • Automatically operated device: Yes___ No_X__ • Does it meet the 5s deactivation requirement after being activated: Yes___ No___ Description: _______________(notes: a plot showing the pulse train does not necessarily constitute an objective evidence of compliance with the deactivation requirement. A plot should be accompanied by an explanation and/or statement of compliance, if not otherwise clearly stated in supporting documentation e.g. operation description page xx) Part 15.231(a)(3): • Periodic transmission at regular predetermined intervals: Yes___ No_X__ N/A___ Description: ________________ • Polling or supervision transmissions, including data, to check system integrity check requires a total transmission time not exceeding 2s per hour: Yes___ No___ N/A_x__ Part 15.231(a)(4): Operation involving fire, security, or safety of life, when activated to signal an alarm, may operate during the pendency of the alarm condition. Does the transmitter meet the condition? Yes___ No___N/A__X_ APPLICANT: MR. BUTLER COMPANY FCC ID: SMK0112601 REPORT: M\Mr._Butler_Co\2715UT6\2715UT6TestReport.doc Page 5 of 14 EMC EQUIPMENT LIST Device Manufacturer Model Serial Number Cal/Char Date Due Date 3-Meter OATS TEI N/A N/A Listed 1/11/06 1/10/09 3/10-Meter OATS TEI N/A N/A Listed 3/27/04 3/26/07 Analyzer Tan Tower Spectrum Analyzer HP 8566B Opt 462 3138A07786 3144A20661 CAL 12/7/05 12/7/07 Analyzer Tan Tower RF Preselector HP 85685A 3221A01400 CAL 12/7/05 12/7/07 Analyzer Tan Tower Quasi- Peak Adapter HP 85650A 3303A01690 CAL 12/8/05 12/8/07 Analyzer Tan Tower Preamplifier HP 8449B-H02 3008A00372 CAL 12/8/05 12/8/07 Analyzer Blue Tower Spectrum Analyzer HP 8568B 2928A04729 2848A18049 CAL 4/13/05 4/13/07 Analyzer Blue Tower RF Preselector HP 85685A 2926A00983 CAL 9/5/05 9/5/07 Analyzer Blue Tower Quasi- Peak Adapter HP 85650A 2811A01279 CAL 4/13/05 4/13/07 Analyzer Silver Tower Spectrum Analyzer HP 8566B Opt 462 3552A22064 3638A08608 CAL 12/8/04 12/8/06 Analyzer Silver Tower RF Preselector HP 85685A 2620A00294 CAL 4/27/04 12/8/06 Analyzer Silver Tower Quasi- Peak Adapter HP 85650A 3303A01844 CAL 12/8/04 12/8/06 Analyzer Open- Frame Tower Preamplifier HP 8449B 3008A01075 CAL 8/8/05 8/8/07 Antenna: Biconnical Electro-Metrics BIA-25 1171 CAL 4/29/05 4/29/07 Antenna: Biconnical Eaton 94455-1 1057 CAL 12/12/05 12/12/07 APPLICANT: MR. BUTLER COMPANY FCC ID: SMK0112601 REPORT: M\Mr._Butler_Co\2715UT6\2715UT6TestReport.doc Page 6 of 14 TEST PROCEDURE RADIATION INTERFERENCE: The test procedure used was ANSI STANDARD C63.4-2003 using a HEWLETT PACKARD spectrum analyzer with a preselector. The bandwidth of the spectrum analyzer was 100 kHz with an appropriate sweep speed. The analyzer was calibrated in dB above a microvolt at the output of the antenna. The resolution bandwidth was 100 kHz and the video b…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

REMOTE CONTROL TRANSMITTER
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
KEYLESS ENTRY SYSTEM
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter