Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Letter of Agency Date: November 22, 2004 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: Please be advised that Reliance Controls Corporation authorizes D.L.S. Electronic Systems, Inc. to act on our behalf, until otherwise notified, for applications submitted to American Telecommunications Certification Body, Inc. (ATCB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. Signatory, Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc. FCC Labeling Requirements and Information Date: November 22, 2004 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: FCC Labeling Requirements FCC ID: SPV-11031 The following label information is required by the FCC Rules and Regulations for certified devices. Also attached, please find marketing information required by the FCC Rules and Regulations. Thank you for your attention to these matters. Sincerely, Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc. Request for Confidentiality Date: November 22, 2004 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: Certification Application FCC ID: SPV-11031 Please be advised that the following information is to be held confidential and behalf of APPLICANT NAME: • Block Diagram • Schematics The application contains technical information which Reliance Controls Corporation deems to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter. Signatory Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc. Modification Letter Date: November 22, 2004 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: Certification Application FCC ID: SPV-11031 Please be advised that the following information is a list of modifications that will be included in the production process for the above-referenced equipment. Change 1: There were no modifications made during testing. Change 2: Change 3: Change 4: Change 5: Change 6: Change 7: Change 8: Change 9 Change 10: Thank you for your attention to this matter. Signatory Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc. Manufacturer’s Letter Date: November 22, 2004 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: Certification Application FCC ID: SPV-11031 To Whom It May Concern: Please be advised that the manufacturer will ensure that the above-referenced model will be manufactured in accordance with the FCC Rules and Regulations. Thank you for your attention to this matter. Signatory Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc.
FCC ID: SPV-11031 D.L.S. ELECTRONIC SYSTEMS, INC. 1250 Peterson Drive Wheeling, Illinois 60090 FCC Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21045-0429 Gentlemen: We are submitting for Reliance Controls Corporation, Inc., a Reliance Controls "The Home Protectors" Wireless Remote Flood or Freeze Warning Alarm Transmitter, Model Number 11031 (part of THP 203 system, part of THP204 system), with a FCC ID: SPV- 11031 for Certification. This unit has been tested and complies to Part 15, Subpart C. If there are any questions in regards to this application, please call D.L.S. Electronic Systems, Inc. at (847) 537 6400. Enclosed you will find a copy of our test report with the information and results of tests that is required under Part 15, Section 15.231. Thank you for your assistance in this matter. Sincerely, Arnom C. Rowe EMC-001375-NE DLS/sr
TOP OF TRANSMITTER TOP OF TRANSMITTER SHOWING PROBE PROBE BOTTOM OF TRANSMITTER BOTTOM OF TRANSMITTER WITH BATTERY COVER REMOVED RIGHT SIDE OF TRANSMITTER LEFT SIDE OF TRANSMITTER TOP SIDE OF TRANSMITTER BOTTOM SIDE OF TRANSMITTER
LABEL AND LOCATION
TOP COVER REMOVED BOTTOM SIDE OF TRANSMITTER CIRCUIT BOARD CLOSE UP OF BOTTOM SIDE OF TRANSMITTER TOP SIDE OF TRANSMITTER CIRCUIT BOARD CLOSE UP OF TRANSMITTER CIRCUIT BOARD
Time Switches / Interval Timers/ Transfer Switches / Panelboards ELECTRICAL INNOVATION SINCE 1909 Reliance Controls Corporation SPV 11031 Transmitter function The transmitter module includes an internal temperature sensor and an external water sensor. When either of the sensors is activated, the alert code generator is activated. It reads the alert code from the code selector and synthesizes the code to be transmitted. It also triggers the power amplifier to the on-state for approximately 0.5 sec, at which time the oscillator signal is modulated by the alert code, and the resultant is amplified and provided to the transmitting antenna for transmission. The transmitter transmits the code (one time only) for 0.5 sec, then locks itself in the “transmitter off” state. It cannot be triggered back on, until the operator physically cycles the power on/off switch to the off position and back to the on position. Once having done so, the transmitter is ready to accept another alert from the sensors. The transmitting antenna consists of a circuit board trace. No external antenna is used. Neil A. Czarnecki, P.E. Director of Engineering Reliance Controls Corporation 12/09/04 Reliance Controls Corporation / 2001 Young Court / Racine, WI 53404-1893 262-634-6155 / FAX 262-634-6436 www.reliancecontrols.com
1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 FCC Rules and Regulations / Intentional Radiators Periodic operational in the 40.66-40.70 MHz Band and above 70 MHz. Part 15, Subpart C, Section 15.231 THE FOLLOWING ''MEETS'' THE ABOVE TEST SPECIFICATION Formal Name: Reliance Controls "The Home Protectors" Wireless Remote Flood or Freeze Warning Alarm Transmitter Kind of Equipment: Wireless Remote Flood or Freeze Warning Alarm Test Configuration: Standalone or powered by wall-mounted AC-to-DC power supply (Tested at 120 vac, 60 Hz) Model Number(s): 11031 (part of THP 203 system, part of THP204 system) Model(s) Tested: 11031 Serial Number(s): NA Date of Tests: April 22 & June 30, 2004 Test Conducted For: Reliance Controls Corporation 2001 Young Court Racine, Wisconsin 53404 NOTICE: “This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government”. Please see the "Additional Description of Equipment Under Test" page listed inside of this report. This report must not be reproduced (except in full), without the approval of D.L.S. Electronic Systems. Page - 1 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 SIGNATURE PAGE Report By: Arnom C. Rowe Test Engineer EMC-001375-NE Reviewed By: William Stumpf OATS Manager Approved By: Brian Mattson General Manager Company Official: Reliance Controls Corporation Page - 2 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 Page -3 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 Page -4 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 Page -5 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 Page -6 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 Page -7 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 Page -8 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 Page -9 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 Page -10 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 Page -11 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 Page -12 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 Page -13 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 Page -14 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 Page -15 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11031 Report Number: 10822 TABLE OF CONTENTS i. Cover Page..........................................................................................................................................1 ii. Signature Page....................................................................................................................................2 iii. NVLAP Certificate of Accreditation..............................................................................................3 iv. NVLAP Scope of Accreditation.....................................................................................................4 v. Table of Contents..............................................................................................................................16 1.0 Summary of Test Report...............................................................................................................17 2.0 Introduction...................................................................................................................................17 3.0 Object............................................................................................................................................17 4.0 Test Set-Up...................................................................................................................................18 5.0 Test Equipment.............................................................................................................................19 6.0 Ambient Measurements................................................................................................................20 7.0 Description of Test Sample...........................................................................................................21 8.0 Additional Description of Test Sample......................................................................................... 22 9.0 Photo Information and Test Set-Up..............................................................................................23 10.0 Radiated Photos Taken During Testing........................................................................................ 24 10.0 Conducted Photos Taken During Testing.....................................................................................26 11.0 Results of Tests.............................................................................................................................27 12.0 Conclusion....................................................................................................................................27 TABLE 1 – EQUIPMENT LIST...........................................................................…
Text truncated - open the document above for the full version.
1250 Perterson Drive · Wheeling, Illinois · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 315 MHz - 315 MHz | - |

CELL PHONE GATEWAY
Equipment Class
PCB - PCS Licensed Transmitter
Wireless Remote Flood or Freeze Warning Alarm
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter