FCC ID: SPV-11034 D.L.S. ELECTRONIC SYSTEMS, INC. 1250 Peterson Drive Wheeling, Illinois 60090 FCC Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21045-0429 Gentlemen: We are submitting for Reliance Controls Corporaton, Inc., a Reliance Controls "The Home Protectors" Wireless Remote Flood or Freeze Warning Alarm Transmitter Transmitter, Model Number: 11034, with a FCC ID: SPV-11034 for Certification. This unit has been tested and complies to Part 15, Subpart C. If there are any questions in regards to this application, please call D.L.S. Electronic Systems, Inc. at (847) 537 6400. Enclosed you will find a copy of our test report with the information and results of tests that is required under Part 15, Section 15.231. Thank you for your assistance in this matter. Sincerely, Arnom C. Rowe EMC-001375-NE DLS/sr
Letter of Agency Date: February 9, 2007 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: Please be advised that Reliance Controls Corporaton authorizes D.L.S. Electronic Systems, Inc. to act on our behalf, until otherwise notified, for applications submitted to American Telecommunications Certification Body, Inc. (ATCB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. Signatory, Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc. FCC Labeling Requirements and Information Date: February 9, 2007 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: FCC Labeling Requirements FCC ID: SPV-11034 The following label information is required by the FCC Rules and Regulations for certified devices. Also attached, please find marketing information required by the FCC Rules and Regulations. Thank you for your attention to these matters. Sincerely, Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc. Modification Letter Date: February 9, 2007 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: Certification Application FCC ID: SPV-11034 Please be advised that the following information is a list of modifications that will be included in the production process for the above-referenced equipment. Change 1: There were no modifications made during testing. Change 2: Change 3: Change 4: Change 5: Change 6: Change 7: Change 8: Change 9 Change 10: Thank you for your attention to this matter. Signatory Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc. Manufacturer’s Letter Date: February 9, 2007 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: Certification Application FCC ID: SPV-11034 To Whom It May Concern: Please be advised that the manufacturer will ensure that the above-referenced model will be manufactured in accordance with the FCC Rules and Regulations. Thank you for your attention to this matter. Signatory Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc.
Request for Confidentiality Date: February 9, 2007 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: Certification Application FCC ID: SPV-11034 Pursuant to 47 CFR Section 0.459 Reliance Controls Corporaton understands that requests for non disclosure and confidential treatment is being made for the following information as stated under the Code of Federal Regulations Chapter 47, Part 0.459 and behalf of APPLICANT NAME: • Block Diagram • Schematics • Technical Product Description The above materials contain trade secrets, proprietary and technical information that would customarily be guarded from competitors under 47 CFR section 0.457(d)(2). Disclosure or publication of any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. Reliance Controls Corporaton understands that pursuant to 47 CFR section 0.457(d)(1)(ii) disclosure of the applicant and all accompanying documentation will not be made before the date of the grant. Thank you for your attention to this matter. Signatory Arnom C. Rowe EMC ENGINEER EMC-001375-NE D.L.S. Electronic Systems, Inc.
Company: Reliance Controls Corporation Model Tested: 11034 FCC ID Number: SPV-11034 Photo Description: Front of EUT Company: Reliance Controls Corporation Model Tested: 11034 FCC ID Number: SPV-11034 Photo Description: Back of EUT Company: Reliance Controls Corporation Model Tested: 11034 FCC ID Number: SPV-11034 Photo Description: Side & Controls Company: Reliance Controls Corporation Model Tested: 11034 FCC ID Number: SPV-11034 Photo Description: Battery Cover
Time Switches / Interval Timers/ Transfer Switches / Panelboards Reliance Controls Corporation / 2001 Young Court / Racine, WI 53404-1893 262-634-6155 / FAX 262-634-6436 www.reliancecontrols.com ELECTRICAL INNOVATION SINCE 1909 February 15, 2007 Jill Stumpf DLS Electronics Systems, Inc. 166 S. Carter Street Genoa City, WI 53128 via FAX 262-279-3630 Dear Jill: Here is the artwork for the FCC label for our product SPV-11034 RF Alert. The artwork is twice scale as you see it. The actual label is printed on adhesive-backed clear plastic, 2.1” W x 0.5” H, including the 0.050” overrun in all directions. FCC ID: SPV-11034 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION Please advise if you need any additional information. Best regards, Cz Neil A. Czarnecki, P.E. Director of Engineering Time Switches / Interval Timers/ Transfer Switches / Panelboards Reliance Controls Corporation / 2001 Young Court / Racine, WI 53404-1893 262-634-6155 / FAX 262-634-6436 www.reliancecontrols.com ELECTRICAL INNOVATION SINCE 1909 Reliance Controls Corporation
Company: Reliance Controls Corporation Model Tested: 11034 FCC ID Number: SPV-11034 Photo Description: PWB TOP Company: Reliance Controls Corporation Model Tested: 11034 FCC ID Number: SPV-11034 Photo Description: PWB BOTTOM
1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11034 Report Number: 12918 FCC Rules and Regulations / Intentional Radiators Periodic operational in the 40.66-40.70 MHz Band and above 70 MHz. Part 15, Subpart C, Section 15.231 THE FOLLOWING ''MEETS'' THE ABOVE TEST SPECIFICATION Formal Name: Reliance Controls "The Home Protectors" Wireless Remote Flood or Freeze Warning Alarm Transmitter Kind of Equipment: Wireless Remote Flood or Freeze Warning Alarm Test Configuration: Standalone or powered by wall-mounted AC-to-DC power supply (Tested at 9 vdc) Model Number(s): 11034 (part of THP 203 system, part of THP204 system Model(s) Tested: 11034 Serial Number(s): NA Date of Tests: October 23 & November 21, 2006 Test Conducted For: Reliance Controls Corporation 2001 Young Court Racine, Wisconsin 53404 NOTICE: “This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government”. Please see the "Additional Description of Equipment Under Test" page listed inside of this report. © Copyright 1983- 2006 D.L.S. Electronic Systems, Inc COPYRIGHT NOTICE This report or any portion their of, may not be reproduced or modified in any form without the expressed written consent of D.L.S. Electronic Systems, Inc. Page - 1 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11034 Report Number: 12918 SIGNATURE PAGE Report By: Arnom C. Rowe Test Engineer EMC-001375-NE Reviewed By: William Stumpf OATS Manager Approved By: Brian Mattson General Manager Company Official: Reliance Controls Corporation Page - 2 - 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11034 Report Number: 12918 TABLE OF CONTENTS i. Cover Page .......................................................................................................................................... 1 ii. Signature Page .................................................................................................................................... 2 iii. Table of Contents ............................................................................................................................ 3 iv. NVLAP Certificate of Accreditation .............................................................................................. 5 1.0 Summary of Test Report ................................................................................................................. 6 2.0 Introduction..................................................................................................................................... 6 3.0 Object .............................................................................................................................................. 6 4.0 Test Set-Up ..................................................................................................................................... 7 5.0 Test Equipment ............................................................................................................................... 8 6.0 Ambient Measurements .................................................................................................................. 9 7.0 Description of Test Sample........................................................................................................... 10 8.0 Additional Description of Test Sample......................................................................................... 11 9.0 Photo Information and Test Set-Up .............................................................................................. 12 10.0 Radiated Photos Taken During Testing ........................................................................................ 13 10.0 Conducted Photos Taken During Testing .....................................................................................16 11.0 Results of Tests ............................................................................................................................. 18 12.0 Conclusion .................................................................................................................................... 18 TABLE 1 – EQUIPMENT LIST .............................................................................................................. 19 Page -3- 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11034 Report Number: 12918 TABLE OF CONTENTS Appendix A – Electric Field Radiated Emissions Test............................................................................. 21 1.0 Conducted Emission Measurements ............................................................................................. 22 1.0 Conducted Data and Graph(s) taken during testing ...................................................................... 23 2.0 Pulsed Operation (Duty Cycle Correction Factor)........................................................................ 28 2.0 Graph taken of the Pulsed Operation (DCCF) .............................................................................. 29 3.0 Bandwidths ................................................................................................................................... 31 3.0 Graph taken of the Bandwidth Emissions..................................................................................... 32 4.0 Field Strength of Spurious Emission Measurements .................................................................... 34 4.0 Data taken of the Fundamental and Spurious Emissions.............................................................. 35 5.0 Restricted Bands ........................................................................................................................... 37 Page -4- 1250 Peterson Dr., Wheeling, IL 60090 Company: Reliance Controls Corporation Model Tested: 11034 Report Number: 12918 Page -5- 1250 Pete…
Text truncated - open the document above for the full version.
Test Date: 02-14-07 Company: Reliance Controls EUT: 11034 Test: 5 second TX stop requirement Operator: Tim Lusha Transmission stops after 332.67 ms. R e f L v l 8 7 d B * R e f L v l 8 7 d B * RBW 1 MHz VBW 1 MHz SWT 2 s RF A t t 1 0 d B A I2A 1MA Uni t d B μ V /m C e n t e r 3 1 4 . 5 50 1 0 0 2 M H z 200 ms/ TDF 1 V I E W 1MA - 1 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 - 1 3 8 7 1 1 M a r k e r 1 [T1] 5 4.99 dBμV/m 3 3 2 .665331 ms D a t e : 1 4 . F E B . 2 0 0 7 1 3 : 4 6 :12
Company: Reliance Controls Corporation Model Tested: 11034 FCC ID Number: SPV-11034 Photo Description: Line Conducted - Front of EUT Company: Reliance Controls Corporation Model Tested: 11034 FCC ID Number: SPV-11034 Photo Description: Line Conducted -Back of EUT Company: Reliance Controls Corporation Model Tested: 11034 FCC ID Number: SPV-11034 Photo Description: Radiated – Front of EUT Company: Reliance Controls Corporation Model Tested: 11034 FCC ID Number: SPV-11034 Photo Description: Radiated – Front of EUT Closeup Company: Reliance Controls Corporation Model Tested: 11034 FCC ID Number: SPV-11034 Photo Description: Radiated – Back of EUT
1250 Peterson Drive · Wheeling, Illinois · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 315 MHz | - |

CELL PHONE GATEWAY
Equipment Class
PCB - PCS Licensed Transmitter
Wireless Remote Flood or Freeze Warning Alarm
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter