FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. R-tron Inc./
  3. STE-APEX1924

STE-APEX1924Repeater

R-tron Inc.
Repeater - FCC ID STE-APEX1924 - R-tron Inc.
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Apr 27, 2011
Application Purpose
Original Equipment
Date of Application
Apr 26, 2011
Equipment Note
Repeater
Frequency Range
1932.50000000 - 1987.50000000
Company
R-tron Inc.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

APEX 1924 User’s Manual Please read this manual before operating this product. After you finish reading this manual, store it in a safe place for future reference. Notice Trademark R-tron is a registered trademark of R-tron Inc. Other products and company names mentioned here in this manual might be trademarks or trade names of their respective owners. Copyright Copyright © R-tron Inc. 2000-2010 All Rights Reserved Any reproduction, distribution, or revisions of any or all portions of this manual is prohibited without written permission from R-tron Inc. Notice This document describes the specifications, installation, and operation of the APEX 1900-24 repeater. Hardware and software mentioned in this document are subject to continuous development and improvement. Consequently, there may be minor discrepancies between the information in the document, performance, and design of the product. Specifications, dimensions, and other statements mentioned in this document are subject to change without notice. Questions or Comments Address: R-tron Inc. 6402 College Boulevard, Overland Park, KS 66211 Phone: +1-913-344-9977, 1-888-317-8766 Fax: +1-913-344-9988 e-mail: [email protected] Website: www.rtronamerica.com APEX 1900-24 USER MANUAL V1.0.00 Tech Support: 1-888-317-8766 1 Safety Precautions Opening the APEX 1900-24 equipment could result in electric shock and may cause severe injury. Connect the equipment frame ground to the building ground. Operating the APEX 1900-24 with antennas in very close proximity facing each other can lead to severe damage to the repeater. RF EXPOSURE INFORMATION A minimum separation distance of 7.9 inches (20cm) must be maintained between the user and the external antenna of the repeater to satisfy FCC RF exposure requirements. For more information about RF exposure, please visit the FCC website at www.fcc.gov This equipment is for indoor use only and enables the communication wiring to communicate inside the building. APEX 1900-24 USER MANUAL V1.0.00 Tech Support: 1-888-317-8766 2 Manual Version History List Revision History Approval Ver. Issue Ver. Date Item/Description Reason Firmware Version History List Revision History Approval Ver. Issue Ver. Date Item/Description Reason WEB GUI Version History List Revision History Approval Ver. Issue Ver. Date Item/Description Reason APEX 1900-24 USER MANUAL V1.0.00 Tech Support: 1-888-317-8766 3 Contents Glossary............................................................................................................................................... 4 1. Introduction.................................................................................................................................. 4 2. Description.................................................................................................................................... 5 2.1 Main Unit Overview............................................................................................................ 5 2.2 Internal Configuration.......................................................................................................... 6 2.2.1 RFU (RF Unit)..........................................................................................7 2.2.2 Duplexer.................................................................................................8 2.2.3 PSU (Power Supply Unit).............................................................................8 2.2.4 MCU (Main Control Unit)............................................................................8 3. Hardware Installation................................................................................................................... 8 3.1 Check List of Items............................................................................................................. 9 3.2 Mounting............................................................................................................................ 9 3.3 Grounding........................................................................................................................ 12 3.4 Cable Connection.............................................................................................................. 12 3.5 Power On..........................................................................................................13 4. Operation.................................................................................................................................... 14 4.1 System Requirements........................................................................................................ 14 4.2 Network Setup.................................................................................................................. 14 4.2.1 Windows XP...........................................................................................14 4.2.2 Windows Vista.........................................................................................16 4.2.3 Windows 7.............................................................................................20 4.3 System Login.................................................................................................................... 24 4.3.1 Network..................................................................................................28 4.3.2 Status....................................................................................................28 4.3.3 Control...................................................................................................28 4.3.4 File Update.............................................................................................29 4.3.5 Alarm History..........................................................................................29 5. Troubleshooting.......................................................................................................................... 30 6. Specifications.......…

Text truncated - open the document above for the full version.

Cover Letter(s)

R-tron, Inc. Date: March21, 2011 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 c.c. Compliance Certification Services Certification Division 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize Jin-Mo Yang, Engineering Manager of ESTECH Co., Ltd. and hereafter referred to as ESTECH, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Jin-Mo Yang, Engineering Manager of ESTECH Co., Ltd. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing ESTECH as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, YONG HOON KANG / CTO R-tron, Inc. REMARK: 1. This authorization letter will be sent along with your application when filing with the Certification Division. 2. Please follow the format and type it on company letterhead and send original to us. 3. Authorized signature must be in agreement with grantee code contact in FCC database.

Cover Letter(s)

R-tron, Inc. Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID:STE-APEX1924 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematic Diagram / Block Diagram Operational description Tune up procedure Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachments until (please enter the product announcement date here): 45days Internal Photos / External Photos / Test setup photo / User manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards YONG HOON KANG / CTO R-tron, Inc. TEL: 82-2-6343-1023, FAX: 82-2-6343-1050

External Photos

APEX1924 EUT-Photograph *Repeater* <Top View > < Bottom View > <Front View> <Rear view> <Left side view> <Right side view>

ID Label/Location Info

1. APEX1924 FCC 257mm (10.11 inch) 396mm (15.59 inch) 158.5mm (6.24 inch) 152.4mm (6 inch) 203.2mm (8 inch) 250mm (9.84 inch) 254mm (10 inch) PRODUCT PART NUMBER : APEX1924POWER : 110 - 220Vac, 50/60HzCO MPLIES W ITH PART 24 FCC RULES.FCC ID : STE-APEX1924SERIAL NO. / DATE :MAKER : R-tron lnc. MADE IN KOREA 2. APEX1924 명판 PRODUCT PART NUMBER : APEX1924POWER : 110 - 220Vac, 50/60HzCOMPLIES WITH PART 24 FCC RULES.FCC ID : STE-APEX1924SERIAL NO. / DATE :MAKER : R-tron lnc. MADE IN KOREA

Internal Photos

APEX1924 EUT-Photograph < The Inside of the Repeater > *RF Unit (RFU) * <RFU Top view> <RFU Bottom view> *MCU(Digital Board)* <MCU Top View> <MCU Bottom View> *NCU* <Top View> <Bottom View> <CPU B’D Top View> <CPU B’D Bottom View> *Duplexer* <Duplexer Donor> <Duplexer Service> *AC-DC PSU*

RF Exposure Info

RF Exposure Measurement 1. Introduction The maximum Gain measured in Fully Anechoic Chamber is 12dBi or 15.85 (numeric). 2. Classification MODE: CDMA 3. RF Exposure Limit Magnetic Field Strength(A/m) Power Density (mW/cm 2 ) Average Time (minutes) 1.63 * (100) 6 4.89/f * (900/f 2 ) 6 0.1631.06 F/3006 56 Magnetic Field Strength(A/m) Power Density (mW/cm 2 ) Average Time (minutes) 1.63 * (100) 30 2.19/f * (180/f 2 ) 30 0.0730.230 -F/150030 -1.030 F = Frequency in MHz 0.3 - 3.0 300 - 1500 1500 - 100,000 614 3.0 - 30 30 - 300 1842/f 61.4 Because this deivce is transmitting the high power signal, it is regarded specially as a dangerous band for its heating harmfulness to the human body. The manufacturer whose product is working in this frequency band is obligatory to prove the harmfulness of his product. In this document, we try to prove the safety of radiation harmfulness to the human body for our product. The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 is followed. The Gain of the antenna used in this product is measured in a Fully Anechoic Chamber (FAC), and the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, Page 1 of 4 The antenna of the product, under normal use condition, is at least 20cm away from the body of the user. Warning statement for keeping 20cm separation distance and the prohibition of operating next to a person has been printed on the user's manual. So, this product is classified as the Mobile Device. According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency(RF) radiation as specified in 1 1307(b) LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) - Class A Frequency Range (MHz) 1500 - 100,000 614 - Electric Field Strength (V/m) LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) - Class B - Frequency Range (MHz) Electric Field Strength (V/m) 0.3 - 1.34 300 - 1500 1.34 - 30 30 - 300 824/f 27.5 4. Friis Formula Friis transmission formula : P d = (P out *G) / (4*π*r 2 ) The maximum Gain measured in Fully Anechoic Chamber is 12dBi or 15.85 (numeric). P out = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 MODE: CDMA Page 2 of 4 The software provided by Manufacturer enabled the EUT to transmit with max power at lowest, middle and highest channel individually. Pd is the limit of MPE, 1mW/cm 2 . If we know the maximum Gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. 6. Test Results 6.1 Antenna Gain The maximum Gain measured in Fully Anechoic Chamber is 12dBi or 15.85 (numeric). 6.2 Output Power into Antenna & RF Exposure value at distance 20cm: MODE: PCS(Uplink) Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 251851.25250.030.596905.0 6001880.00247.740.591435.0 11751908.75249.460.595545.0 MODE: PCS(Down Link) Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 251931.25248.890.594185.0 6001960.00244.910.584685.0 11751988.75250.030.596905.0 Page 3 of 4 The minimum allowable distance is very close to the enclosure of the antenna and is very far away from the human beign under normal use condition. MODE: LTE(Uplink) Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 501852.50246.040.587375.0 6001880.00247.740.591445.0 11501907.50249.460.595545.0 MODE: LTE(Down Link) Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 501932.50246.600.588725.0 6001960.00247.740.591445.0 11501987.50245.470.586025.0 The minimum allowable distance is very close to the enclosure of the antenna and is very far away from the human beign under normal use condition. Page 4 of 4

Test Report

Product Name Model Name Applicant FCC ID R-tron Inc. ESTECH CO., LTD. http://www.estech.co.kr FCC TEST REPORT Repeater ESTECH CO., LTD Rm. 1015 World Venture Center, 426-5 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea. Tel:82-2-867-3201, Fax:82-2-867-3204 APEX1924 STE-APEX1924 Report Number : ESTR1104-007EST-QP-20-01(0)1 of 49 FCC ID : STE-APEX1924 Company Name Address Product Name Model No.Manufacturer Serial No. Country of origin Issued DateTested Date ESTECH CO., LTD. http://www.estech.co.kr Rm. 1015 World Venture Center, 426-5 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea. Tel:82-2-867-3201, Fax:82-2-867-3204 ESTECH CO., LTD FCC Test Report Applicant Product Report Number APEX1924 KOREA R-tron Inc. o This is certified that the above mentioned products have been tested for the sample provided by client. o No part of this document may not be duplicated or reproduced by any means without the express written permission of Estech Co., Ltd. Standard FCC PART 24 Subpart E Tested by Approved by I.K. Hong/ Engineer (Signature) Tag-Sun Park/Engineering manager (Signature) Test Result Pass 2011-04-182011-03-15 ~ 2011-04-18Other ESTR1104-007 Jisan IT Venture Center 7F, 1004-9 Doksan-Dong, Gumcheon-Gu, Seoul, Korea Repeater NONE R-tron Inc. Report Number : ESTR1104-007EST-QP-20-01(0)2 of 49 FCC ID : STE-APEX1924 1. General Information Page 4 2. Laboratory Information Page 5 3. Summary of Test Results Page 5 4. RF Output Power Page 6 5. Occupied Bandwidth Page 14 6. Spurious and Harmonic Emission at Antenna Terminal Page 22 7. Field Strength of Spurious Radiation Page 40 8. Frequency stability Page 45 Contents ESTECH CO., LTD. http://www.estech.co.kr Report Number : ESTR1104-007EST-QP-20-01(0)3 of 49 FCC ID : STE-APEX1924 1. General Information 1.1 EUT Description Downlink 1931.25MHz ~ 1988.75MHz (PCS) Downlink 1932.50MHz ~ 1987.50MHz(PCS for LTE) ESTECH CO., LTD. http://www.estech.co.kr FCC ID STE-APEX1924 Product Name Repeater Input: 110~240VAC 50~60Hz Power Rating Uplink&Downlink (25/600/1175) Model Name Channel Uplink&Downlink (50/600/1150) APEX1924 Frequency Uplink 1851.25MHz ~ 1908.75MHz (PCS) Uplink 1852.50MHz ~ 1907.50MHz (PCS for LTE) Report Number : ESTR1104-007EST-QP-20-01(0)4 of 49 FCC ID : STE-APEX1924 2. Laboratory Information 3. Summary of Test Results Result PASS PASS PASS PASS PASS PASS 2.1051 Field Strength of Spurious Radiation Frequency stability Modulation Characteristics2.1047 2.1055 2.1053 RF Output Power Occupied Bandwidth PASS Spurious and Harmonic Emission at Antenna Terminal ESTECH CO., LTD. http://www.estech.co.kr 58-1, Osan-Ri, GaNam-Myon, YeoJoo-Gun, KyungKi-Do, Korea 97-1, Hoiuk-Ri Majang-Myon, Icheon-city, KyungKi-Do, Korea 2.1 Laboratory Name 2.2 Location Estech Co., Ltd. 2.4 Major Accredited Mark Head Office EMC Lab(Ichon) EMC Lab(Yanggi) 2.3 Quality System 2.1049Band Edge Rm. 1015, World Venture Center II, 426-5 Gasan-dong Geumcheon-gu, Seoul, 153-803. Korea. Accredited by KOLAS(ISO/IEC 17025) 2.1046 2.1049 StandardTest Item Report Number : ESTR1104-007EST-QP-20-01(0)5 of 49 FCC ID : STE-APEX1924 4. RF Output Power 4.1 Test Procedure according to ANSI/TIA/EIA 603 Clause 2.2.17 4.2 Test Equipments The following test equipments are used during tests Next Cal. 2011-09-09 2012-02-24 2012-02-15 2012-02-24 4.3.1 Test Results (Uplink)-PCS Conducted power Low25 Mid.600 High1175 23.94 23.97 1851.2523.93 1880.00 1908.75 Freq (MHz) Signal Generator Spectrum Analyzer SMBV100A Ch No.Power Output (dBm) E4432B Spectrum AnalyzerAgilent HP ROHDE&SCHWARZ ESTECH CO., LTD. http://www.estech.co.kr E4402B Vector Signal Generato r Model E4440AAgilent 1. The EUT was placed on a wooden turn table 3 meters from the receive antenna. The receive antenna height and turn table rotation was adjusted for the highest reading on the receive spectrum analyzer. For CDMA signals, a peak detector is used, with RBW = VBW = 3MHz. For AMPS, GSM, and NADC TDMA signals, a peak detector is used, with RBW = VBW = 1MHz, A Horn antenna was substituted in place of the EUT. This Horn antenna was driven by a signal generator and the level of the signal generator was adjusted to obtain the same receive spectrum analyzer reading. This spurious level is recorded. For reading 1GHz, the above procedure is repeated using horn antennas and the difference between the gain of the horn and an isotropic or dipole antenna are taken into consideration. 2. The RF output port of the EUT was connected to the dual directional coupler and Wireless communications test set connected dual directional coupler The RF Power is measured Power matter This test was performed three channels (Low, High, Middle) 3. Test setup for RF Conducted measurement EquipmentManufacturer Report Number : ESTR1104-007EST-QP-20-01(0)6 of 49 FCC ID : STE-APEX1924 4.3.2 Test Results (Downlink)-PCS Low25 Mid600 High1175 4.3.3 Test Results (Uplink)-PCS FOR LTE Low50 Mid600 High1150 4.3.3 Test Results (Downlink)-PCS FOR LTE Low50 Mid600 High1150 ESTECH CO., LTD. http://www.estech.co.kr Power Output (dBm) 23.98 Power Output (dBm) Ch No. Freq (MHz)Ch No. 1960.00 Ch No. Freq (MHz) 1960.00 23.89 1988.75 1931.25 Freq (MHz) 23.92 1907.50 23.96 1987.5023.90 1852.5023.93 1880.00 Power Output (dBm) 1932.50 23.94 23.97 23.94 Report Number : ESTR1104-007EST-QP-20-01(0)7 of 49 FCC ID : STE-APEX1924 4.4 Test Plot Uplink-PCS RF Power Output (25) RF Power Output (600) RF Power Output (1175) ESTECH CO., LTD. http://www.estech.co.kr Report Number : ESTR1104-007EST-QP-20-01(0)8 of 49 FCC ID : STE-APEX1924 Downlink-PCS RF Power Output (25) RF Power Output (600) RF Power Output (1175) ESTECH CO., LTD. http://www.estech.co.kr Report Number : ESTR1104-007EST-QP-20-01(0)9 of 49 FCC ID : STE-APEX1924 Input Signal Output Power Uplink Ch PCS(600) Downlink Ch PCS(600) ESTECH CO., LTD. http://www.estech.co.kr Report Number : ESTR1104-007EST-QP-20-01(0)10 of 49 FCC ID : STE-APEX1924 4.4 Test Plot Uplink-PCS for LTE RF Power Output (25) RF Power Output (600) RF Power Output (1150) ESTEC…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yong Hoon Kang
[email protected]+82-2-6343-1005Fax: +82-2-6343-1050

Test Firm

ESTECH Co., Ltd.Yang Jinmo
[email protected]82-31-631-8037Fax: 82-31-631-8039

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
424E1.93 GHz - 1.99 GHz248.00 mWF9WAmp
Confidentiality
Long Term
Grant Notes
Licensed Repeater. Outpower listed is conducted single channel power for each modulation. For multiple carrier operation, single channel output power shall be reduced in proportion to the number of carrier used. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of section 1.1307(b)(3), for satisfying RF exposure compliance, the antenna installation must provide a minimum separation distance of 20 cm from users and nearby persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

Other Applications from R-tron Inc.

RF Repeater - FCC ID STE-APEX8930 - R-tron Inc.
STE-APEX8930

RF Repeater

Dec 05, 2011

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
LTE Repeater - FCC ID STE-QUADCOMM-700N - R-tron Inc.
STE-QUADCOMM-700N

LTE Repeater

Oct 19, 2011

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
LTE Band Repeater - FCC ID STE-APEX730 - R-tron Inc.
STE-APEX730

LTE Band Repeater

Oct 14, 2011

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Repeater - FCC ID STE-APEX1930 - R-tron Inc.
STE-APEX1930

Repeater

Apr 25, 2011

Equipment Class

PCB - PCS Licensed Transmitter
CAT-5 DAS TRI BAND REPEATER - FCC ID STESN-CAT5DAS - R-tron Inc.
STESN-CAT5DAS

CAT-5 DAS TRI BAND REPEATER

Nov 13, 2010

Equipment Class

AMP - Amplifier