Controlled Entry Distributors, Inc. FCC Confidentiality Request Number: CF303 Version: V05 Date: 21-05-2012 (Permanent or also called long term confidentiality is the normal method to keep certain docuements confidential, and may apply to schematics, block diagrams, operational description and bill of materials.) To: Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Pursuant to 47 CFR Section 0.459(a) & (b), we, (the applicant / grantee) Company name Controlled Entry Distributors, Inc. Address 2500 South 3850 West, Suite A, City Salt Lake Cit y, UT 84120 Country US A request for this certification filing under: Grantee Code Product Number FCC ID: SU7 -WIHIDEM to maintain permanent confidentiality for the following documents submitted within this application: (please cross what is applicable, or add other documents, provide the file name and description) Exhibit File Name Description β Operational Description Operational Description explaining the functioning of the block diagram β Block Diagrams Block Diagrams showing the systematic building blocks of the EUT β Schematics Diagrams Schematics showing components, their values and interconnection Bill of Materials List of components used on the PCBβs of the EUT Above materials crossed contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. We understand that pursuant to 47 CFR section 0.457(d)(1)(ii) disclosure of the applicant and all accompanying documentation will not be made before the date of the grant. The documents indicated as confidential above, are not publicly available elsewhere. Attestation: City and Country: Date: Name: (this must be a person) Function:Signature: (or official company stamp) Salt Lake City, USA 2013-12-12 Bradley KoffordPresident
Figure 1 The EUT-Front View Figure 2 The EUT-Back View
Label Location On EUT
Product Name: Wiegand Reader Model No.: DOLCMWIHIDEM FCC ID: SU7-WIHIDEM This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Figure 3 The EUT-Inside View Figure 4 PCB of the EUT-Front View Figure 5 PCB of the EUT-Back View
Shenzhen Anbotek Compliance Laboratory Limited FCC ID: SU7-WIHIDEM Page 1 of 22 Report No.: 201311949F Shenzhen Anbotek Compliance Laboratory Limited Tel: (86)755-26066544 Fax: (86)755-26014772 www.anbotek.com FCC TEST REPORT for Controlled Entry Distributors, Inc. Wiegand Reader Model No.: DOLCMWIHIDEM, DOLCSWIHIDEM Prepared for : Controlled Entry Distributors, Inc. Address : 2500 South 3850 West, Suite A, Salt Lake City, UT 84120 USA Prepared By : Shenzhen Anbotek Compliance Laboratory Limited Address : 1/F., Building 1, SEC Industrial Park, No.0409 Qianhai Road, Nanshan District, Shenzhen, Guangdong, China Tel: (86) 755-26066544 Fax: (86) 755-26014772 Report Number : 201311949F Date of Test : Nov. 26~ Dec. 09, 2013 Date of Report : Dec. 09, 2013 Shenzhen Anbotek Compliance Laboratory Limited FCC ID: SU7-WIHIDEM Page 2 of 22 Report No.: 201311949F Shenzhen Anbotek Compliance Laboratory Limited Tel: (86)755-26066544 Fax: (86)755-26014772 www.anbotek.com TABLE OF CHONTENTS Description Page Test Report Verification 1. GENERAL INFORMATION ............................................................................................................ 4 1.1. Description of Device (EUT) ..........................................................................................................................4 1.2. Description of Test Facility .............................................................................................................................5 1.3. Measurement Uncertainty ...............................................................................................................................5 2. TEST PROCEDURE ............................................................................................................................. 6 3. POWER LINE CONDUCTED MEASUREMENT ............................................................................ 7 3.1. Block Diagram of Test Setup ..........................................................................................................................7 3.2. Power Line Conducted Emission Measurement Limits (FCC Part 15 15.207) ...............................................7 3.3. Configuration of EUT on Measurement ..........................................................................................................7 3.4. Operating Condition of EUT ...........................................................................................................................7 3.5. Test Procedure .................................................................................................................................................8 3.6. Power Line Conducted Emission Measurement Results .................................................................................8 4. RADIATED EMISSION MEASUREMENT ..................................................................................... 11 4.1. Radiated Emission Limits .............................................................................................................................11 4.2. Test Procedure ...............................................................................................................................................11 4.3. Test Setup ......................................................................................................................................................12 4.4. Test Results (Below 30MHz) ........................................................................................................................14 4.5. Test Results (Between 30-1000MHz) ...........................................................................................................14 5. OCCUPIED BANDWIDTH ................................................................................................................ 17 5.1. Requirements (2.1049): .................................................................................................................................17 5.2. Test Procedure ...............................................................................................................................................17 5.4. Test Results ...................................................................................................................................................17 6. TEST SETUP PHOTOGRAPH .......................................................................................................... 19 6.1. Photo of Conducted Emission Measurement ................................................................................................19 6.2. Photo of Radiation Emission Test .................................................................................................................19 APPENDIX I (External Photos) (1 Pages) APPENDIX II (Internal Photos) (2 Pages) Shenzhen Anbotek Compliance Laboratory Limited FCC ID: SU7-WIHIDEM Page 3 of 22 Report No.: 201311949F Shenzhen Anbotek Compliance Laboratory Limited Tel: (86)755-26066544 Fax: (86)755-26014772 www.anbotek.com TEST REPORT VERIFICATION Applicant : Controlled Entry Distributors, Inc. Manufacturer : Controlled Entry Distributors, Inc. EUT : Wiegand Reader Model No. : DOLCMWIHIDEM, DOLCSWIHIDEM Rating : DC 9-24V, οΌ25mA Trade Mark : N/A Measurement Procedure Used: FCC Rules and Regulations Part 15 Subpart C 15.207&15.209-2012, Part 2: 2012 & FCC / ANSI C63.4-2009 The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited To determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC Part 15 Subpart C limits both radiated and conducted emissions. The measurement results are contained in this test report and Shenzhen Anbotek Compliance Laboratory Limited Is assumed full responsibility for the accuracy and completeness of these measurements. Also, this report shows that the Equipment Under Test (EUT) is to be technically compliant with the FCC requireβ¦
Text truncated - open the document above for the full version.
1. Photo of Conducted Emission Test 2. Photo of Radiated Emission Test
Rietven 31 Β· Enschede, Overyssel Β· Netherlands
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |

Part 15 Security / Remote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Control
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Control
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter