Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
M2B OEM Users Guide DataRateAvg. TXToleranceDataRateSensitivityTolerance 1-24Mbps28 dBm+/-2dB1-24Mbps-97 dBm min.+/-2dB 36Mbps27 dBm+/-2dB36Mbps-80 dBm+/-2dB 48Mbps26 dBm+/-2dB48Mbps-77 dBm+/-2dB 54Mbps24 dBm+/-2dB54Mbps-75 dBm+/-2dB MCS028 dBm+/-2dBMCS0-96 dBm+/-2dB MCS128 dBm+/-2dBMCS1-95 dBm+/-2dB MCS228 dBm+/-2dBMCS2-92 dBm+/-2dB MCS328 dBm+/-2dBMCS3-90 dBm+/-2dB MCS427 dBm+/-2dBMCS4-86 dBm+/-2dB MCS525 dBm+/-2dBMCS5-83 dBm+/-2dB MCS624 dBm+/-2dBMCS6-77 dBm+/-2dB MCS723 dBm+/-2dBMCS7-74 dBm+/-2dB Shock and VibrationETSI300-019-1.4 Power MethodPassive Power over Ethernet (pairs 4,5+; 7,8 return) Operating Temperature -30C to 75C Operating Humidity5 to 95% Condensing Max Power Consumption3.5 Watts Power SupplyPOE up to 24V DC (sold separately) Enclosure Size16cm length x 8cm width x 3cm height Weight0.5 kg PHYSICAL / ELECTRICAL / ENVIRONMENTAL Airmax 11n Airmax11n OPERATING FREQUENCY 2412MHz-2462MHz TX POWER SPECIFICATIONSRX SPECIFICATIONS 11g 11g REGULATORY / COMPLIANCE INFORMATION Wireless ApprovalsFCC Part 15.247, IC RS210, CE RoHS ComplianceYES SYSTEM INFORMATION Processor SpecsAtheros MIPS 24KC, 400MHz Memory Information32MB SDRAM, 8MB Flash Networking Interface1 X 10/100 BASE-TX (Cat. 5, RJ-45) Ethernet Interface TECHNICAL SPECIFICATIONS COMPLIANCE INFORMATION FCC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to pro-vide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The antennas used for this transmitter must be installed to provide a separation distance of at least following distance from all persons and must not be located or operating in conjunction with any other antenna or transmitter. 38cm distance for the Grid Antenna 20cm distance for the Omni Antenna Highest gains are 24dBi for Grid and 6dBi for Omni Antenna INDUSTRY CANADA This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. The device has been designed to operate with the antennas listed below and having a maximum gain of 24dBi. Antennas not included in this list or having a gain greater than 24dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms This device must be professionally installed and is designed for for outdoor point-to-point wireless links.
Ubiquiti Networks, Inc. 91 E. Tasman San Jose, CA 95134 12/28/09 Attn: MET laboratories 914 West Patapsco Ave. Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR M2B (FCC ID: SWX-M2B) To Whom It May Concern: This letter serves as an official request for confidentiality under FCC Rule Section 0.457 & 0.459. We have requested that the schematics, block diagrams, theory of operation, and internal photos required to be submitted with this application be withheld from public review. These documents contain proprietary information that would sacrifice our competitive advantage in the marketplace if made public. Additionally, the mechanical enclosure locking is proprietary and not possible to open by general public Please contact me if there is any information you may need. Sincerely, Robert J. Pera Senior RF Engineer
Jennifer Sanchez From: Jennifer Sanchez Sent: Monday, February 15, 2010 1:49 PM To: Dusmantha Tennakoon Cc: Jenn Warnell; Shawn McMillen; Jennifer Sanchez Subject: RE: Technical Review Request: 82071 Ubiquiti Networks - FCC/IC TCB (Model M2B) Importance: High 2/15/2010 Hi Dusmantha, Please see response below: FCC: 1. There appears to be a conducted emission at 3.2 GHz that falls in the restricted band. Did this show up when making radiated measurements and if so was the field strength measured to verify that it met the restricted band requirements? The 3.2 GHz peak didn’t show up in radiated measurements. 2.The order of the plots for the power spectral density needs to change. The peak determination plot needs to come before the measurement plot. The plots have been corrected, please refer to file EMCS-82071A-FCC247_Rev1.pdf 3.The internal pictures are blurred. Please retake these pictures so that individual components are clearly seen. The photos have been corrected, please refer to file Internal Photos_Rev1.pdf 4.The block diagram of test configuration (i.e. Figure 4) and Table 4 only show the dish antenna. The Omni antenna should also be listed. The report has been corrected, please refer to file EMCS- 82071A-FCC247_Rev1.pdf 5.The RF safe distance listed in the user’s manual is incorrect. The manual has been corrected, please refer to file User_guideM2B_Rev1.pdf 6.Editorial errors on page 55 of 146 and page 69 of 146 under test procedures. The report has been corrected, please refer to file EMCS-82071A-FCC247_Rev1.pdf 7.Power listed on form 731 for the 40 MHz signal is incorrect. Please refer to the check sheet. The form has been corrected, please refer to file 82071 Ubiquiti - Form 731_M2B_Rev1.doc IC: 1.The IC label is incorrect. It should read “IC: xxx” and not “IC ID: xxx”. The label has been corrected, please refer to file label_m2b_REV1.pdf 2. The 99% bandwidth has not been measured correctly. A RBW of approximately 1% of the span must be used without going below. According to the RSS-GEN, “The resolution bandwidth shall be set to as close as 1% of the selected span as is possible without being below 1%”. The measured resolution bandwidth is not below 1% and it’s one step up from 300kHz. 3.The receiver spur plots are labeled incorrectly. The plots have been corrected, please refer to file EMCS-82071A-FCC247_Rev1.pdf 4.The RF evaluation in the IC package should list General Public Use. The form has been corrected, please refer to file 82071 Ubiquiti Networks - IC Package_M2B_Rev1.doc 5.The RF power listed in the IC package for the 40 MHz signal is incorrect. Please refer to the check sheet. The form has been corrected, please refer to file 82071 Ubiquiti Networks - IC Package_M2B_Rev1.doc 6. Please refer to the check sheet for the correct worst case transmitter and receiver spurs. The form has been corrected, please refer to file 82071 Ubiquiti Networks - IC Package_M2B_Rev1.doc
B B IC
2.4GHz Antenna List M2B 1. 24dBi Grid Antenna 2. 6dBi Omni Antenna Ubiquiti AG-2G-24 Gain: 24dBi Dimensions: 15.7 x 23.6 inches (400 x 600 mm) 1. 2. Ubiquiti O-2G-6 Gain: 6dBi Dimensions: Length: 197mm
Electromagnetic Compatibility Ubiquiti Networks Intentional Radiators M2B CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 MET Report: EMCS82071A-FCC247 © 2010, MET Laboratories, Inc. Page 53 of 146 DOC-EMC702 6/18/2009 Electromagnetic Compatibility Criteria for Intentional Radiators § 15.247(b) RF Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 2412-2462 MHz ; highest conducted power = 29.78dBm (peak) therefore, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 EUT maximum antenna gain = 6dBi Omni Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R 2 or R = √PG / 4S where, S = Power Density (1 mW/cm 2 ) P = Power Input to antenna (950.60mW) G = Antenna Gain (3.98 numeric) S = (950.60*3.98 / 4*3.14*20.0 2 )= (3784.426/ 5024) = 0.753 mW/cm 2 @ 20cm separation MPE Limit Calculation: EUT’s operating frequencies @ 2412-2462 MHz ; highest conducted power = 18.44dBm (peak) therefore, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 EUT maximum antenna gain = 24dBi Grid Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R 2 or R = √PG / 4S where, S = Power Density (1 mW/cm 2 ) P = Power Input to antenna (69.82mW) G = Antenna Gain (251.18 numeric) R = (69.82*251.18/ 4*3.14*1.0) 1/2 = (17538.81 / 12.56) 1/2 = 37.36cm
MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 The Nation’s First Licensed Nationally Recognized Testing Laboratory February 12, 2010 Ubiquiti Networks 91 E. Tasman San Jose, CA 95134 Dear Robert Pera, Enclosed is the EMC Wireless test report for compliance testing of the Ubiquiti Networks, M2B as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Part 15, Subpart B, ICES-003, Issue 4 February 2004 for a Class A Digital Device and FCC Part 15 Subpart C, RSS-210, Issue 7, June 2007 for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Sanchez Documentation Department Reference: (\Ubiquiti Networks\EMCS82071A-FCC247_Rev1) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. Electromagnetic Compatibility Ubiquiti Networks Cover Page M2B CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 MET Report: EMCS82071A-FCC247_Rev1 © 2010, MET Laboratories, Inc. Page ii of xi DOC-EMC702 6/18/2009 Electromagnetic Compatibility Criteria Test Report for the Ubiquiti Networks M2B Tested under the FCC Certification Rules contained in Title 47 of the CFR, Parts 15 Subpart B & ICES-003 for Class A Digital Devices & 15.247 Subpart C & RSS-210, Issue 7, June 2007 for Intentional Radiators MET Report: EMCS82071A-FCC247_Rev1 February 12, 2010 Prepared For: Ubiquiti Networks 91 E. Tasman San Jose, CA 95134 Prepared By: MET Laboratories, Inc. 3162 Belick St. Santa Clara, CA 95054 Electromagnetic Compatibility Ubiquiti Networks Cover Page M2B CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 MET Report: EMCS82071A-FCC247_Rev1 © 2010, MET Laboratories, Inc. Page iii of xi DOC-EMC702 6/18/2009 Electromagnetic Compatibility Criteria Test Report for the Ubiquiti Networks M2B Tested under the FCC Certification Rules contained in Title 47 of the CFR, Parts 15 Subpart B & ICES-003 for Class A Digital Devices & 15.247 Subpart C & RSS-210, Issue 7, June 2007 for Intentional Radiators Minh Ly, Project Engineer Jennifer Sanchez Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules Parts 15B, 15.247 and Industry Canada standards ICES-003, Issue 4 February 2004, RSS-210, Issue 7, June 2007 under normal use and maintenance. Shawn McMillen, Wireless Manager, Electromagnetic Compatibility Lab Electromagnetic Compatibility Ubiquiti Networks Report Status M2B CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 MET Report: EMCS82071A-FCC247_Rev1 © 2010, MET Laboratories, Inc. Page iv of xi DOC-EMC702 6/18/2009 Report Status Sheet Revision Report Date Reason for Revision January 28, 2010 Initial Issue. 1 February 8, 2010 Final Issue 2 February 12, 2010 Rev 1 Electromagnetic Compatibility Ubiquiti Networks Table of Contents M2B CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 MET Report: EMCS82071A-FCC247_Rev1 © 2010, MET Laboratories, Inc. Page v of xi DOC-EMC702 6/18/2009 Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview.............................................................................................................................................................4 B. References...........................................................................................................................................................5 C. Test Site ..............................................................................................................................................................5 D. Description of Test Sample.................................................................................................................................5 E. Equipment Configuration....................................................................................................................................8 F. Support Equipment .............................................................................................................................................8 G. Ports and Cabling Information ............................................................................................................................8 H. Mode of Operation..............................................................................................................................................9…
Text truncated - open the document above for the full version.
Electromagnetic Compatibility Ubiquiti Networks Unintentional Radiators M2B CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 Conducted Emission Limits Test Setup Photograph 1. Conducted Emissions, Test Setup MET Report: EMCS82071A-FCC247 © 2010, MET Laboratories, Inc. Page 13 of 146 DOC-EMC702 6/18/2009 Electromagnetic Compatibility Ubiquiti Networks Unintentional Radiators M2B CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 Radiated Emission Limits Test Setup Photograph 2. Radiated Emission, 30MHz-1GHz Test Setup MET Report: EMCS82071A-FCC247 © 2010, MET Laboratories, Inc. Page 18 of 146 DOC-EMC702 6/18/2009 Electromagnetic Compatibility Ubiquiti Networks Unintentional Radiators M2B CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 Radiated Emission Limits Test Setup Photograph 3. Radiated Emission, 1-2GHz Test Setup MET Report: EMCS82071A-FCC247 © 2010, MET Laboratories, Inc. Page 19 of 146 DOC-EMC702 6/18/2009 Electromagnetic Compatibility Ubiquiti Networks Intentional Radiators M2B CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 Conducted Emissions Test Setup Photograph Photograph 4. Conducted Emissions, 15.207, Test Setup MET Report: EMCS82071A-FCC247 © 2010, MET Laboratories, Inc. Page 25 of 146 DOC-EMC702 6/18/2009 Electromagnetic Compatibility Ubiquiti Networks Intentional Radiators M2B CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 Radiated Harmonic Emissions Test Setup Photographs Photograph 5. Radiated Harmonic Emission, Test Setup (6dBi Omni) MET Report: EMCS82071A-FCC247 © 2010, MET Laboratories, Inc. Page 97 of 146 DOC-EMC702 6/18/2009 Electromagnetic Compatibility Ubiquiti Networks Intentional Radiators M2B CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 Radiated Harmonic Emissions Test Setup Photographs Photograph 6. Radiated Harmonic Emission, Test Setup (24dBi Grid) MET Report: EMCS82071A-FCC247 © 2010, MET Laboratories, Inc. Page 98 of 146 DOC-EMC702 6/18/2009 Electromagnetic Compatibility Ubiquiti Networks Intentional Radiators M2B CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 Restricted Band Test Setup Photographs Photograph 7. Restricted Band, Test Setup (6dBi Omni) MET Report: EMCS82071A-FCC247 © 2010, MET Laboratories, Inc. Page 99 of 146 DOC-EMC702 6/18/2009 Electromagnetic Compatibility Ubiquiti Networks Intentional Radiators M2B CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 Restricted Band Test Setup Photographs Photograph 8. Restricted Band, Test Setup (24dBi Grid) MET Report: EMCS82071A-FCC247 © 2010, MET Laboratories, Inc. Page 100 of 146 DOC-EMC702 6/18/2009
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 950.00 mW |
SuperLink Gateway HA
Equipment Class
DTS - Digital Transmission SystemDigital Transmission Radio
Equipment Class
DTS - Digital Transmission SystemRecessed Entry Sensor
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterG6 Edge Dome
Equipment Class
DTS - Digital Transmission SystemG6 Edge Turret
Equipment Class
DTS - Digital Transmission System