Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
91 E. Tasman Dr. | San Jose, CA 95134 | U.S.A. | Tel. 1-408-942-3085| Fax 1-408-351-4973. Elliott TCB 41039 Boyce Road Fremont, CA, 94538 To whom it may concern: The enclosed documents constitute a formal submittal and application for Equipment Authorization for the Ubiquiti Networks NanoStationM5 pursuant to the following rules: FCC Part 15.247 RSS-210 The NanoStationM5 is a 5GHz Hi Power 2x2 MIMO AirMax TDMA Station, which operates as a point-to-point CPE. If there are any questions or if further information is needed, please contact Jennifer Sanchez at Ubiquiti Networks for assistance. Sincerely, Jennifer Sanchez Wireless Compliance Manager Ubiquiti Networks [email protected]
91 E. Tasman Dr. | San Jose, CA 95134 | U.S.A. | Tel. 1-408-942-3085| Fax 1-408-351-4973. Ubiquiti Networks, Inc. 91 E. Tasman San Jose, CA 95134 May 3, 2011 National Technical Systems 41039 Boyce Road Fremont, CA, 94538 RE: CONFIDENTIALITY REQUEST FOR NanoStationM5 (FCC ID: SWX-M5N) To Whom It May Concern: This letter serves as an official request for confidentiality under FCC Rule Section 0.457 & 0.459. We request that the schematics, block diagram, theory of operation required to be submitted with this applicatio n be withheld from public review. These documents contain proprietary information th at would sacrifice our competitive advantage in the marketplace if made public. Please contact me if there is any information you may need. Sincerely, Robert J. Pera President
91 E. Tasman Dr. | San Jose, CA 95134 | U.S.A. | Tel. 1-408-942-3085| Fax 1-408-351-4973. March 24, 2011 Subject: Signing Authority for Agency Approvals Dear Regulatory Authority, Please accept this letter authorizing Jennifer Sanchez of Ubiquiti Networks to act on my behalf as the point of contact for any FCC or Industry Canada filings and submissions for Grantee Code SWX and Industry Canada Company Number 6545A. Sincerely, Robert Pera CEO/Founder Ubiquiti Networks
91 E. Tasman Dr. | San Jose, CA 95134 | U.S.A. | Tel. 1-408-942-3085| Fax 1-408-351-4973. Ubiquiti Networks, Inc. 91 E. Tasman San Jose, CA 95134 May 12, 2011 National Technical Systems 41039 Boyce Road Fremont, CA, 94538 RE: Professional Installation for Ubiquiti Networks Models NanoStationM5 and LocoStationM5 To Whom It May Concern: This product is designed for outdoor point to point broadband wireless. It is available through special distribution channels worldwide serving system integrators in the Wireless Internet Service Provider Industry. A professional installer with experience in extended Ethernet cable deployment, tower mounting, and Ubiquiti AirMax system knowledge will be required to properly enable the equipment. Please contact me if there is any information you may need. Sincerely, Robert J. Pera President
§ 15.247(i) Maximum Permissible Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 5725-5850 MHz; highest conducted power = 29.88dBm (peak) therefore, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 EUT maximum antenna gain = 16 dBi. Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R 2 or R = √PG / 4S where, S = Power Density (1 mW/cm 2 ) P = Power Input to antenna (972.75mW) G = Antenna Gain (39.81 numeric) R = (972.75*39.81/ 4*3.14*1.0) 1/2 = (38725.76 / 12.56) 1/2 = 55.53cm
MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 The Nation’s First Licensed Nationally Recognized Testing Laboratory May 5, 2011 Ubiquiti Networks 91 E. Tasman San Jose, CA 95134 Dear Robert Pera, Enclosed is the EMC Wireless test report for compliance testing of the Ubiquiti Networks, NanoStationM5 as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Part 15, Subpart B, ICES-003, Issue 4 February 2004 for a Class A Digital Device and FCC Part 15 Subpart C, RSS-210, Issue 8, Dec. 2010 for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\Ubiquiti Networks\EMCS82947-FCC247 Rev. 1) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. Electromagnetic Compatibility Ubiquiti Networks Cover Page NanoStationM5 CFR Title 47, Part 15B, 15.247; RSS-210, Issue 8, Dec. 2010 & ICES-003 MET Report: EMCS82947-FCC247 Rev. 1 © 2011, MET Laboratories, Inc. Page ii of xv DOC-EMC702 6/18/2009 Electromagnetic Compatibility Criteria Test Report for the Ubiquiti Networks NanoStationM5 Tested under the FCC Certification Rules contained in Title 47 of the CFR, Parts 15 Subpart B & ICES-003 for Class A Digital Devices & 15.247 Subpart C & RSS-210, Issue 8, Dec. 2010 for Intentional Radiators MET Report: EMCS82947-FCC247 Rev. 1 May 5, 2011 Prepared For: Ubiquiti Networks 91 E. Tasman San Jose, CA 95134 Prepared By: MET Laboratories, Inc. 3162 Belick St. Santa Clara, CA 95054 Electromagnetic Compatibility Ubiquiti Networks Cover Page NanoStationM5 CFR Title 47, Part 15B, 15.247; RSS-210, Issue 8, Dec. 2010 & ICES-003 MET Report: EMCS82947-FCC247 Rev. 1 © 2011, MET Laboratories, Inc. Page iii of xv DOC-EMC702 6/18/2009 Electromagnetic Compatibility Criteria Test Report for the Ubiquiti Networks NanoStationM5 Tested under the FCC Certification Rules contained in Title 47 of the CFR, Parts 15 Subpart B & ICES-003 for Class A Digital Devices & 15.247 Subpart C & RSS-210, Issue 8, Dec. 2010 for Intentional Radiators Lionel Gabrillo, Project Engineer Jennifer Warnell Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules Parts 15B, 15.247 and Industry Canada standards ICES-003, Issue 4 February 2004, RSS-210, Issue 8, Dec. 2010 under normal use and maintenance. Shawn McMillen, Wireless Manager, Electromagnetic Compatibility Lab Electromagnetic Compatibility Ubiquiti Networks Report Status NanoStationM5 CFR Title 47, Part 15B, 15.247; RSS-210, Issue 8, Dec. 2010 & ICES-003 MET Report: EMCS82947-FCC247 Rev. 1 © 2011, MET Laboratories, Inc. Page iv of xv DOC-EMC702 6/18/2009 Report Status Sheet Revision Report Date Reason for Revision to Report April 26, 2011 Initial Issue 1 May 5, 2011 Revised to reflect TCB corrections. Electromagnetic Compatibility Ubiquiti Networks Table of Contents NanoStationM5 CFR Title 47, Part 15B, 15.247; RSS-210, Issue 8, Dec. 2010 & ICES-003 MET Report: EMCS82947-FCC247 Rev. 1 © 2011, MET Laboratories, Inc. Page v of xv DOC-EMC702 6/18/2009 Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview.............................................................................................................................................................4 B. References...........................................................................................................................................................5 C. Test Site ..............................................................................................................................................................5 D. Description of Test Sample.................................................................................................................................6 E. Equipment Configuration....................................................................................................................................8 F. Support Equipment .............................................................................................................................................8 G. Ports and Cabling Information ............................................................................................................................8 H. Mode of Operation.......................................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 5.73 GHz - 5.85 GHz | 972.00 mW |
SuperLink Gateway HA
Equipment Class
DTS - Digital Transmission SystemDigital Transmission Radio
Equipment Class
DTS - Digital Transmission SystemRecessed Entry Sensor
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterG6 Edge Dome
Equipment Class
DTS - Digital Transmission SystemG6 Edge Turret
Equipment Class
DTS - Digital Transmission System