FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ubiquiti Inc./
  3. SWX-MSW

SWX-MSWPIR & Microwave Motion Detector

Ubiquiti Inc.
PIR & Microwave Motion Detector - FCC ID SWX-MSW - Ubiquiti Inc.
Click to zoom

Application Details

Equipment Class
FDS - Part 15 Field Disturbance Sensor
Date of Grant
May 30, 2012
Application Purpose
Original Equipment
Date of Application
May 30, 2012
Equipment Note
PIR & Microwave Motion Detector
Frequency Range
10525.00000000 - 10525.00000000
Company
Ubiquiti Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Ubiquiti Networks, Inc. Add: 2580 Orchard Parkway, San Jose, CA 95131 Tel: (408) 942-3085 Fax: (408) 351-4973 FCC Confidential Authorization 05/21/2012 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Confidentiality Request regarding application for certification of FCC ID: SWX-MSW Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: β€’ Test Setup/External/Internal Photographs of EUT--- (Short term, 180 Days) β€’ User Manual--- (Short term, 180 Days) β€’ Detailed Circuit Schematics of EUT--- (Long term) β€’ Block Diagram--- (Long term) β€’ Circuit Description--- (Long term) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely Yours, Jennifer Sanchez Wireless Compliance Manager

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS EUT – Top View EUT – Bottom View

ID Label/Location Info

EXHIBIT A - FCC ID LABELING AND LOCATION FCC ID Label FCC ID Label Location Label here

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS EUT – Cover off View EUT – Main Board Top View Antenna EUT – Main Board Top Shielding off View EUT – Mainboard Bottom View EUT – Antenna Top View EUT – Antenna Bottom View EUT – Antenna Bottom Shielding off View

Test Report

Note: This test report is prepared for the customer shown above and for the equipment described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP*, or any agency of the Federal Government. * This report contains data that are not covered by the NVLAP accreditation and are marked with an asterisk β€œβ˜…β€ (Rev.2) FCC PART 15.245 MEASUREMENT AND TEST REPORT For Ubiquiti Networks, Inc. 2580 Orchard Parkway, San Jose, CA 95131, USA FCC ID: SWX-MSW Report Type: Original Report Product Type: Field Disturbance Sensor Test Engineer: Henry Ding Report Number: RSZ120222004-00 Report Date: 2012-05-31 Reviewed By: Alvin Huang RF Leader Test Laboratory: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ120222004-00 FCC Part 15.245 Page 2 of 11 TABLE OF CONTENTS GENERAL INFORMATION.......................................................................................................................................3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3 OBJECTIVE...................................................................................................................................................................3 RELATED SUBMITTAL(S)/GRANT(S).............................................................................................................................3 TEST METHODOLOGY..................................................................................................................................................3 TEST FACILITY.............................................................................................................................................................3 SYSTEM TEST CONFIGURATION ..........................................................................................................................5 JUSTIFICATION.............................................................................................................................................................5 EQUIPMENT MODIFICATIONS.......................................................................................................................................5 BLOCK DIAGRAM OF TEST SETUP................................................................................................................................5 SUMMARY OF TEST RESULTS ...............................................................................................................................6 FCC Β§15.203 - ANTENNA REQUIREMENT.............................................................................................................7 APPLICABLE STANDARD..............................................................................................................................................7 ANTENNA CONNECTOR CONSTRUCTION......................................................................................................................7 FCC Β§15.205, Β§15.209 & Β§15.245(B) - RADIATED EMISSIONS .............................................................................8 APPLICABLE STANDARD..............................................................................................................................................8 MEASUREMENT UNCERTAINTY....................................................................................................................................9 TEST EQUIPMENT SETUP..............................................................................................................................................9 EUT SETUP..................................................................................................................................................................9 TEST PROCEDURE......................................................................................................................................................10 CORRECTED AMPLITUDE & MARGIN CALCULATION.................................................................................................10 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................10 TEST RESULTS SUMMARY..........................................................................................................................................11 TEST DATA................................................................................................................................................................11 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ120222004-00 FCC Part 15.245 Page 3 of 11 GENERAL INFORMATION Product Description for Equipment under Test (EUT) The Ubiquiti Networks, Inc. ’s product, model number: mFi-MSW (FCC ID: SWX-MSW), or the "EUT" in this report is a Field Disturbance Sensor, named PIR & Microwave Motion Detector by applicant, which was measured approximately: 14.6 cm (L) x 6.6 cm (W) x 5.2 cm (H), rated input voltage: DC 12 V. * All measurement and test data in this report was gathered from production sample serial number: 1202064 (Assigned by BACL, Shenzhen). The EUT was received on 2012-02-22. Objective This test report is prepared on behalf of Ubiquiti Networks, Inc. in accordance with Part 2-Subpart J, and Part 15-Subparts A, B and C of the Federal Communication Commissions rules. The tests were performed in order to determine the compliance of the EUT with FCC Part 15-Subpart C, section 15.203, 15.205, 15.209 and 15.245 rules. Related Submittal(s)/Grant(s) No relat…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS Below 1 GHz: Radiated Emissions Above 1 GHz: Radiated Emissions View

Contact Information

Applicant

Alex Macon
[email protected]385-200-1617Fax: 408-904-7556

Test Firm

Bay Area Compliance Laboratory Corp. (Shenzhen)John Chan
[email protected]08675533320018Fax: 08675533320008

Technical Specifications

#Rule PartsFrequency RangePower Output
115.24510.53 GHz - 10.53 GHz-
Confidentiality
Long Term

Other Applications from Ubiquiti Inc.

SWX-USLGGH

SuperLink Gateway HA

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
SWX-UTRLR

Digital Transmission Radio

Aug 19, 2026

Equipment Class

DTS - Digital Transmission System
SWX-USLER

Recessed Entry Sensor

Aug 12, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
SWX-UVCG6ED

G6 Edge Dome

Jul 07, 2026

Equipment Class

DTS - Digital Transmission System
SWX-UVCG6ET

G6 Edge Turret

Jul 07, 2026

Equipment Class

DTS - Digital Transmission System