FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ubiquiti Inc./
  3. SWX-U6P

SWX-U6PDigital Transmission Radio

Ubiquiti Inc.
Digital Transmission Radio - FCC ID SWX-U6P - Ubiquiti Inc.
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Oct 20, 2022
Application Purpose
Original Equipment
Date of Application
Oct 20, 2022
Equipment Note
Digital Transmission Radio
Frequency Range
5745.00000000 - 5825.00000000
Company
Ubiquiti Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

E-Label User Information FCC ID: SWX-U6P IC ID: 6545A-U6P Ubiquiti Inc. will be incorporating the E-Label procedures per FCC KDB 784748-D02. The information below is what will be included in the E-Labeling. E-label and warning statements can be found in the device/controller GUI under Device > Settings > About. Detailed compliance information including Declaration of Conformity is available at the following internet address: ui.com/compliance FCC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generated, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user bill be required to correct the interference at his own expense. ISED Canada CAN ICES-3 (A) / NMB-3 (A) This device complies with ISED Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. CAN ICES-3 (A) / NMB-3 (A) Le présent appareil est conforme aux CNR d’ISDE Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: 1. L’appareil ne doit pas produire de brouillage; 2. I’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. RF Exposure Warning The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter. Les antennes utilisées pour ce transmetteur doivent être installé en considérant une distance de séparation de toute personnes d’au moins 20 cm et ne doivent pas être localisé ou utilize en conflit avec tout autre antenne ou transmetteur.

Cover Letter(s)

Power of Attorney Date: 2021/01/20 Dear Sir or Madam, I hereby have entrusted the following entity to be an authorized agent regarding application for Type Certification. Ubiquiti Inc. also authorizes the following entity to be a proxy to handle all certification matters. Unified Compliance Laboratories Address : 427 W 12800 South Draper Utah 84020 e-mail : [email protected] Applicant : Ubiquiti Inc. Address : 685 Third Avenue ,New York NY 10017 United States Of America Name and Job Title. : Mark Feil / Compliance Director E-mail : [email protected] Tel. : 385-200-1617

Cover Letter(s)

685 3 RD AVE. • NEW Y0RK, NY 10071 • www.ui.com Date: 10/7/2022 TIMCO Engineering, Inc. 849 N.W. State Road 45 P.O. Box 370 Newberry, Florida 32669 RE: Request for Confidentiality In reference to the application under FCC ID: SWX-U6P, and pursuant to Sections 0.457(d)1(ii) and 0.459 of the Commission’s Rules, Ubiquiti Networks hereby requests permanent confidential treatment of the accompanying information as outlined below: Block Diagram Schematics Theory of Operation Software Security Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to Ubiquiti Networks and provide unjustified benefits to its competitors. In addition to the above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the important rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short term confidentiality on the following attachments until 180 days from grant date. External Photos Internal Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondence during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Ubiquiti Networks understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Alex Macon Ubiquiti lnc. Compliance Manager

External Photos

427 West 12800 South, Draper, UT 84020 Photograph 1: Front View of DUT Photograph 2: Back View of DUT Ingress Cover On 427 West 12800 South, Draper, UT 84020 Photograph 3: Back View of DUT Ingress Cover Off Side 1 Photograph 4: Back View of DUT Ingress Cover Off Side 4 427 West 12800 South, Draper, UT 84020 Photograph 5: Back View of DUT Ingress Cover Off Side 3 Photograph 6: Back View of DUT Ingress Cover Off Side 4 427 West 12800 South, Draper, UT 84020 Photograph 7: Connector

Internal Photos

427 West 12800 South, Draper, UT 84020 Photograph 1: Front View of DUT Shields in place Antenna’s 427 West 12800 South, Draper, UT 84020 Photograph 2: Front View of DUT Shields removed 427 West 12800 South, Draper, UT 84020 Photograph 3: Rear View of DUT

RF Exposure Info

§ 15.407(f) Maximum Permissible Exposure Test Requirement(s): §15.407(f): U-NII devices are subject to the radio frequency radiation exposure requirements specified in §1.1307(b), §2.1091 and §2.1093 of this chapter, as appropriate. All equipment shall be considered to operate in a “general population/uncontrolled” environment. RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit: EUT’s operating frequencies @ UNII-1 5180 – 5240 MHz, UNII-3 5745 – 5825 MHz, BLE 2402 – 2480 MHz, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R 2 or R = √(PG / 4S) where, S = Power Density (mW/cm 2 ) P = Power Input to antenna (mW) G = Antenna Gain (numeric value) R = Distance (cm) Test Results: FCC Frequency (MHz) Con. Pwr. (dBm) Con. Pwr. (mW) Ant. Gain (dBi) Ant. Gain numeric Pwr. Density (mW/cm 2 ) Limit (mW/cm 2 ) Margin Distance (cm) Result 2402* 26.92 492 4.0 2.51 0.245 1.0 -0.755 20 Pass 5240 26.6 457 5.4 3.47 0.316 1.0 -0.684 20 Pass 5775* 28.3 676 5.4 3.47 0.467 1.0 -0.533 20 Pass *Simultaneous Transmission (Worse case): 0.712 1.0 -0.288 20 Pass The U6+may have simultaneously transmission of the 15.247 2.4 GHz WiFi, and 15.407 UNII-1 or UNII-3 bands. Both UNII-1 and UNII-3 bands do not transmit simultaneously. Asterisk notes the worst case of the possible simultaneously transmitter combinations. Simultaneously Transmitters Summed: + 0.245 (2.4 GHz WiFi) + 0.467 (UNII-3) = 0.712 Limit of 1.0 – 0.712 (summed value) = -0.288 Margin The safe distance for SWX-U6P where Power Density is less than the MPE Limit listed above was found to be 20 cm.

Test Report

427 West 12800 South Draper, UT 84020 Test Report Certification FCC ID SWX-U6P ISED ID 6545A-U6P Equipment Under Test U6+ Test Report Serial Number TR7527_05 Date of Tests August 28 through October 5, 2022, April 5, 2023 Report Issue Date April 5, 2023 Test Specification Applicant 47 CFR FCC Part 15, Subpart E RSS-247 Ubiquiti Inc. 685 Third Avenue New York, NY 10017 U.S.A. NVLAP LAB CODE 600241-0 427 West 12800 South, Draper, UT 84020 TR7527_U6+_FCC_15.407_UNII-1_05 Page 2 of 59 PROPRIETARY Certification of Engineering Report This report has been prepared by Unified Compliance Laboratory (UCL) to document compliance of the device described below with the requirement of Federal Communication Commissions (FCC) Part 15, Subpart E. This report may be reproduced in full. Partial reproduction of this report may only be made with the written consent of the laboratory. The results in this report apply only to the sample tested. Applicant Ubiquiti Inc. Manufacturer Ubiquiti Inc. Brand Name UniFi Model Number U6+ FCC ID SWX-U6P ISED ID 6545A-U6P On this 5 th day of April 2023, I individually and for Unified Compliance Laboratory certify that the statements made in this engineering report are true, complete, and correct to the best of my knowledge and are made in good faith. Although NVLAP has accredited the Unified Compliance Laboratory testing facilities, this report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the U.S. federal government. Unified Compliance Laboratory Written By: Clay Allred Reviewed By: Joseph W. Jackson 427 West 12800 South, Draper, UT 84020 TR7527_U6+_FCC_15.407_UNII-1_05 Page 3 of 59 PROPRIETARY Revision History Revision Description Date 01 Original Report Release 6 October 2022 02 Added Test for AX mode to the report 12 October 2022 03 Corrected RSS-247 references and added test data per RSS-247 October 17, 2022 04 Corrected NVALP expiration dates October 19, 2022 05 Corrected Antenna description, Gains and results April 5, 2023 427 West 12800 South, Draper, UT 84020 TR7527_U6+_FCC_15.407_UNII-1_05 Page 4 of 59 PROPRIETARY Table of Contents 1 Client Information ................................................................................................................................. 5 1.1 Applicant ....................................................................................................................................... 5 1.2 Manufacturer ................................................................................................................................. 5 2 Equipment Under Test (EUT) ............................................................................................................... 6 2.1 Identification of EUT .................................................................................................................... 6 2.2 Description of EUT ....................................................................................................................... 6 2.3 EUT and Support Equipment ........................................................................................................ 7 2.4 Interface Ports on EUT ................................................................................................................. 7 2.5 Operating Environment ................................................................................................................. 7 2.6 Operating Modes ........................................................................................................................... 7 2.7 EUT Exercise Software ................................................................................................................. 8 2.8 Block Diagram of Test Configuration .......................................................................................... 8 2.9 Modification Incorporated/Special Accessories on EUT .............................................................. 8 2.10 Deviation, Opinions Additional Information or Interpretations from Test Standard .................... 8 3 Test Specification, Method and Procedures .......................................................................................... 9 3.1 Test Specification .......................................................................................................................... 9 3.2 Methods & Procedures .................................................................................................................. 9 3.3 FCC Part 15, Subpart E ................................................................................................................. 9 3.4 Results ........................................................................................................................................... 9 3.5 Test Location .............................................................................................................................. 10 4 Test Equipment ................................................................................................................................... 11 4.1 Direct Connect at the Antenna Port Tests ................................................................................... 11 4.2 Radiated Emissions ..................................................................................................................... 12 4.3 Equipment Calibration ................................................................................................................ 12 4.4 Measurement Uncertainty ........................................................................................................... 13 5 Test Results ......................................................................................................................................... 14 5.1 §15.203 Antenna Requirements .................................................................................................. 14 5.2 §15.403(i)…

Text truncated - open the document above for the full version.

Test Report

427 West 12800 South Draper, UT 84020 Test Report Certification FCC ID SWX-U6P ISED ID 6545A-U6P Equipment Under Test U6+ Test Report Serial Number TR7528_05 Date of Test(s) August 28 through October 5, 2022, April 5, 2023 Report Issue Date April 5, 2023 Test Specification Applicant 47 CFR FCC Part 15, Subpart E Ubiquiti Inc. 685 Third Avenue New York, NY 10019 U.S.A. NVLAP LAB CODE 600241-0 427 West 12800 South, Draper, UT 84020 TR7528_U6+_FCC_15.407_UNII-3_05 Page 2 of 91 PROPRIETARY Certification of Engineering Report This report has been prepared by Unified Compliance Laboratory (UCL) to document compliance of the device described below with the requirement of Federal Communication Commissions (FCC) Part 15, Subpart E. This report may be reproduced in full. Partial reproduction of this report may only be made with the written consent of the laboratory. The results in this report apply only to the sample tested. Applicant Ubiquiti Inc. Manufacturer Ubiquiti Inc. Brand Name UniFi Model Number U6+ FCC ID SWX-U6P ISED ID 6545A-U6P On this 5 th day of April 2023, I individually and for Unified Compliance Laboratory certify that the statements made in this engineering report are true, complete and correct to the best of my knowledge and are made in good faith. Although NVLAP has accredited the Unified Compliance Laboratory testing facilities, this report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the U.S. federal government. Unified Compliance Laboratory Written By: Clay Allred Reviewed By: Joseph W. Jackson 427 West 12800 South, Draper, UT 84020 TR7528_U6+_FCC_15.407_UNII-3_05 Page 3 of 91 PROPRIETARY Revision History Revision Description Date 01 Original Report Release October 6, 2022 02 Added AX test data to the end of this report. October 12, 2022 03 Revised RSS-247 references October 17, 2022 04 Corrected NVALP expiration dates October 19, 2022 05 Corrected antenna MIMO description, gain and results April 5, 2023 427 West 12800 South, Draper, UT 84020 TR7528_U6+_FCC_15.407_UNII-3_05 Page 4 of 91 PROPRIETARY Table of Contents 1 Client Information ................................................................................................................................. 5 1.1 Applicant ....................................................................................................................................... 5 1.2 Manufacturer ................................................................................................................................. 5 2 Equipment Under Test (EUT) ............................................................................................................... 6 2.1 Identification of EUT .................................................................................................................... 6 2.2 Description of EUT ....................................................................................................................... 6 2.3 EUT and Support Equipment ........................................................................................................ 7 2.4 Interface Ports on EUT ................................................................................................................. 7 2.5 Operating Environment ................................................................................................................. 7 2.6 Operating Modes ........................................................................................................................... 7 2.7 EUT Exercise Software ................................................................................................................. 7 2.8 Block Diagram of Test Configuration .......................................................................................... 8 2.9 Modification Incorporated/Special Accessories on EUT .............................................................. 8 2.10 Deviation, Opinions Additional Information or Interpretations from Test Standard .................... 8 3 Test Specification, Method and Procedures .......................................................................................... 9 3.1 Test Specification .......................................................................................................................... 9 3.2 Methods & Procedures .................................................................................................................. 9 3.3 FCC Part 15, Subpart E ................................................................................................................. 9 3.4 Results ........................................................................................................................................... 9 3.5 Test Location .............................................................................................................................. 10 4 Test Equipment ................................................................................................................................... 11 4.1 Direct Connect at the Antenna Port Tests ................................................................................... 11 4.2 Radiated Emissions ..................................................................................................................... 12 4.3 Equipment Calibration ................................................................................................................ 12 4.4 Measurement Uncertainty ........................................................................................................... 13 5 Test Results ......................................................................................................................................... 14 5.1 §15.203 Antenna Requirements .................................................................................................. 14 5.2 §15.403(i) 26 dB & 99% Emissions Ban…

Text truncated - open the document above for the full version.

Test Report

PR OPRIETARY INFORMATION [U6+] antenna measurement 2023/03/31 Jerome Cheng PR OPRIETARY INFORMATION [WiFi measurement] Peak gain (dBi) 2.4G (Max gain frequency) 3 Model117-03918 Antenna type: Stamp PR OPRIETARY INFORMATION [WiFi measurement] Peak gain (dBi) 5G (Max gain frequency) 5.4 Model117-03918 Antenna type: Stamp PR OPRIETARY INFORMATION [WIFI Antenna Photo] CONFIDENTIAL - INTERNAL USE ONLY

Test Setup Photos

427 West 12800 South, Draper, UT 84020 Photograph 1: View Test Set Up Radiated Emissions 30 – 1000 MHz Photograph 2: View Test Set Up Radiated Emissions 1 – 17 GHz 427 West 12800 South, Draper, UT 84020 Photograph 3: View Test Set Up Radiated Emissions 17 – 40 GHz Photograph 4: View Test Set Up RF Conducted

Contact Information

Applicant

Alex Macon
[email protected]385-200-1617Fax: 408-904-7556

Test Firm

Unified Compliance LaboratoryClay Allred
[email protected]801-530-9355

Technical Specifications

#Rule PartsFrequency RangePower Output
215E5.75 GHz - 5.83 GHz632.40 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. This device supports 20, 40 and 80 MHz modes.

Other Applications from Ubiquiti Inc.

SWX-USLGGH

SuperLink Gateway HA

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
SWX-UTRLR

Digital Transmission Radio

Aug 19, 2026

Equipment Class

DTS - Digital Transmission System
SWX-USLER

Recessed Entry Sensor

Aug 12, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
SWX-UVCG6ED

G6 Edge Dome

Jul 07, 2026

Equipment Class

DTS - Digital Transmission System
SWX-UVCG6ET

G6 Edge Turret

Jul 07, 2026

Equipment Class

DTS - Digital Transmission System