FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ubiquiti Inc./
  3. SWX-UAHOTEL

SWX-UAHOTELSmart Access Door Lock

Ubiquiti Inc.
Smart Access Door Lock - FCC ID SWX-UAHOTEL - Ubiquiti Inc.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jan 20, 2021
Application Purpose
Original Equipment
Date of Application
Jan 20, 2021
Equipment Note
Smart Access Door Lock
Frequency Range
13.56000000 - 13.56000000
Company
Ubiquiti Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

E-Label User Information FCC ID: SWX-UAHOTEL IC ID: 6545A-UAHOTEL Ubiquiti Inc. will be incorporating the E-Label procedures per FCC KDB 784748-D02. The information below is what will be included in the E-Labeling. E-label and warning statements can be found in the device/controller GUI under Device > Settings > About. Detailed compliance information including Declaration of Conformity is available at the following internet address: ui.com/compliance FCC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generated, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user bill be required to correct the interference at his own expense. ISED Canada CAN ICES-3 (A) / NMB-3 (A) This device complies with ISED Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. CAN ICES-3 (A) / NMB-3 (A) Le présent appareil est conforme aux CNR d’ISDE Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: 1. L’appareil ne doit pas produire de brouillage; 2. I’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. RF Exposure Warning The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter. Les antennes utilisées pour ce transmetteur doivent être installé en considérant une distance de séparation de toute personnes d’au moins 20 cm et ne doivent pas être localisé ou utilize en conflit avec tout autre antenne ou transmetteur.

Cover Letter(s)

Date:2020/12/23 TIMCO Engineering, Inc. 849 N.W. State Road 45 P.O. Box 370 Newberry, Florida 32669 RE: Request for Confidentiality In reference to the application under FCC ID: SWX-UAHOTEL, and pursuant to Sections 0.457(d)1(ii) and 0.459 of the Commission’s Rules, Ubiquiti Networks hereby requests permanent confidential treatment of the accompanying information as outlined below: Block Diagram Schematics Theory of Operation The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to Ubiquiti Networks and provide unjustified benefits to its competitors. In addition to the above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the important rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short term confidentiality on the following attachments until 180 days from grant date. External Photos Internal Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondence during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Ubiquiti Networks understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Mark Feil Ubiquiti Networks, lnc. Compliance Manager 685 3 RD AVE. 27 TH FLOOR • NEW Y0RK, NY 10071 • www.ubnt.com

Cover Letter(s)

Power of Attorney Date: 2021/01/20 Dear Sir or Madam, I hereby have entrusted the following entity to be an authorized agent regarding application for Type Certification. Ubiquiti Inc. also authorizes the following entity to be a proxy to handle all certification matters. Unified Compliance Laboratories Address : 427 W 12800 South Draper Utah 84020 e-mail : [email protected] Applicant : Ubiquiti Inc. Address : 685 Third Avenue ,New York NY 10017 United States Of America Name and Job Title. : Mark Feil / Compliance Director E-mail : [email protected] Tel. : 385-200-1617

External Photos

427 West 12800 South, Draper, UT 84020 Photograph 1: Front View of DUT Photograph 2: Bottom View of DUT 427 West 12800 South, Draper, UT 84020 Photograph 3: Right-Side View of DUT Photograph 4: Top View of DUT 427 West 12800 South, Draper, UT 84020 Photograph 5: Left-Side View of DUT Photograph 6: Back View of DUT 427 West 12800 South, Draper, UT 84020 Photograph 7: Label Location

Internal Photos

427 West 12800 South, Draper, UT 84020 Photograph 1: Connected Circuit Boards in Housing Photograph 2: Connected Circuit Boards 427 West 12800 South, Draper, UT 84020 Photograph 3: Top View of Circuit Boards Photograph 4: Bottom View of Circuit Boards

Test Report

427 West 12800 South Draper, UT 84020 Test Report Certification FCC ID SWX-UAHOTEL IC ID 6545A-UAHOTEL Equipment Under Test UA-Hotel-R and UA-Hotel-L Test Report Serial Number TR5734_02 Date of Test(s) 18 December 2020 and 14 January 2021 Report Issue Date 15 January 2021 Test Specification Applicant 47 CFR FCC Part 15, Subpart C RSS-210 Ubiquiti Inc. 685 Third Avenue New York, NY 10019 U.S.A. NVLAP LAB CODE 600241-0 427 West 12800 South, Draper, UT 84020 TR5734_UA-Hotel_15.225_NFC_02 Page 2 of 19 PROPRIETARY Certification of Engineering Report This report has been prepared by Unified Compliance Laboratory (UCL) to document compliance of the device described below with the requirement of Federal Communication Commissions (FCC) Part 15, Subpart C. This report may be reproduced in full. Partial reproduction of this report may only be made with the written consent of the laboratory. The results in this report apply only to the sample tested. Applicant Ubiquiti Inc. Manufacturer Ubiquiti Inc. Brand Name UniFi Model Number UA-Hotel-R and UA-Hotel-L FCC ID SWX-UAHOTEL IC ID 6545A-UAHOTEL On this 15 th day of January 2021, I individually and for Unified Compliance Laboratory certify that the statements made in this engineering report are true, complete and correct to the best of my knowledge and are made in good faith. Although NVLAP has accredited the Unified Compliance Laboratory testing facilities, this report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the U.S. federal government. Unified Compliance Laboratory Written By: Joseph W. Jackson Reviewed By: Richard L. Winter 427 West 12800 South, Draper, UT 84020 TR5734_UA-Hotel_15.225_NFC_02 Page 3 of 19 PROPRIETARY Revision History Revision Description Date 01 Original Report Release 15 January 2021 02 Amend Standard References and Add Temperature Results 20 January 2021 427 West 12800 South, Draper, UT 84020 TR5734_UA-Hotel_15.225_NFC_02 Page 4 of 19 PROPRIETARY Table of Contents 1 Client Information ................................................................................................................................. 5 1.1 Applicant ....................................................................................................................................... 5 1.2 Manufacturer ................................................................................................................................. 5 2 Equipment Under Test (EUT) ............................................................................................................... 6 2.1 Identification of EUT .................................................................................................................... 6 2.2 Description of EUT ....................................................................................................................... 6 2.3 EUT and Support Equipment ........................................................................................................ 6 2.4 Interface Ports on EUT ................................................................................................................. 6 2.5 Operating Environment ................................................................................................................. 7 2.6 Operating Modes ........................................................................................................................... 7 2.7 EUT Exercise Software ................................................................................................................. 7 2.8 Block Diagram of Test Configuration .......................................................................................... 7 2.9 Modification Incorporated/Special Accessories on EUT .............................................................. 7 2.10 Deviation, Opinions Additional Information or Interpretations from Test Standard .................... 7 3 Test Specification, Method and Procedures .......................................................................................... 8 3.1 Test Specification .......................................................................................................................... 8 3.2 Methods & Procedures .................................................................................................................. 8 3.3 FCC Part 15, Subpart C, RSS-210 B6 .......................................................................................... 8 3.4 Results ........................................................................................................................................... 8 3.5 Test Location ................................................................................................................................ 8 4 Test Equipment ................................................................................................................................... 10 4.1 Radiated Emissions ..................................................................................................................... 10 4.2 Equipment Calibration ................................................................................................................ 10 4.3 Measurement Uncertainty ........................................................................................................... 11 5 Test Results ......................................................................................................................................... 12 5.1 Bandwidth Measurements ........................................................................................................... 12 5.2 §15.225 (a) Field Strength .......................................................................................................... 13 5.3 §15.225 (b)(c)(d) Spurious Emissions Requirements ................................................................. 14 5.4 §15.209 Spurious …

Text truncated - open the document above for the full version.

Test Setup Photos

427 West 12800 South, Draper, UT 84020 Photograph 1: Test Setup Radiated Emissions 30 – 1000 MHz Photograph 2: Test Setup Radiated Emissions 1 – 17 GHz 427 West 12800 South, Draper, UT 84020 Photograph 3: Test Setup NFC Configuration

Contact Information

Applicant

Alex Macon
[email protected]385-200-1617Fax: 408-904-7556

Test Firm

Unified Compliance LaboratoryAlex Macon
[email protected]385-200-1617

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from Ubiquiti Inc.

SWX-USLGGH

SuperLink Gateway HA

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
SWX-UTRLR

Digital Transmission Radio

Aug 19, 2026

Equipment Class

DTS - Digital Transmission System
SWX-USLER

Recessed Entry Sensor

Aug 12, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
SWX-UVCG6ED

G6 Edge Dome

Jul 07, 2026

Equipment Class

DTS - Digital Transmission System
SWX-UVCG6ET

G6 Edge Turret

Jul 07, 2026

Equipment Class

DTS - Digital Transmission System