FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ubiquiti Inc./
  3. SWX-WAVEPRO

SWX-WAVEPRODigital Transmission Radio

Ubiquiti Inc.
Digital Transmission Radio - FCC ID SWX-WAVEPRO - Ubiquiti Inc.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
May 16, 2023
Application Purpose
Original Equipment
Date of Application
May 15, 2023
Equipment Note
Digital Transmission Radio
Frequency Range
58320.00000000 - 69120.00000000
Company
Ubiquiti Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

E-Label User Information FCC ID: SWX-WAVEPRO IC ID: 6545A-WAVEPRO Ubiquiti Inc. will be incorporating the E-Label procedures per FCC KDB 784748-D02. The information below is what will be included in the E-Labeling. E-label and warning statements can be found in the device/controller GUI under Device > Settings > About. Detailed compliance information including Declaration of Conformity is available at the following internet address: ui.com/compliance NOTE This outdoor access point operating in the U-NII-1 band the maximum e.i.r.p. at any elevation angle above 30 degrees must not exceed 125 mW (21 dBm) FCC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generated, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user bill be required to correct the interference at his own expense. ISED Canada CAN ICES-3 (A) / NMB-3 (A) This device complies with ISED Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. CAN ICES-3 (A) / NMB-3 (A) Le présent appareil est conforme aux CNR d’ISDE Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: 1. L’appareil ne doit pas produire de brouillage; 2. I’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. RF Exposure Warning The antennas used for this transmitter must be installed to provide a separation distance of at least 400 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter. Les antennes utilisées pour ce transmetteur doivent être installé en considérant une distance de séparation de toute personnes d’au moins 400 cm et ne doivent pas être localisé ou utilize en conflit avec tout autre antenne ou transmetteur.

Attestation Statements

www.ui.com Date: 9 February 2023 Federal Communications Commission (the “Commission” or “FCC”) Authorization and Evaluation Division 7435 Oakland Mills Rd. Columbia, MD 21046 USA RE: Attestation Statements Part 2.911(d)(5)(i) Filing – FCC ID: SWX-WAVEPRO Ubiquiti Inc. (“the applicant”) certifies that, as of the date of the application, the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Alex Macon Ubiquiti lnc. Compliance Officer

Attestation Statements

www.ui.com Date: 9 February 2023 Federal Communications Commission (the “Commission” or “FCC”) Authorization and Evaluation Division 7435 Oakland Mills Rd. Columbia, MD 21046 USA RE: Attestation Statements Part 2.911(d)(5)(ii) Filing – FCC ID: SWX-WAVEPRO Ubiquiti Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List 1 as an entity producing “covered” equipment. Sincerely, Alex Macon Ubiquiti lnc. Compliance Officer 1 https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

www.ui.com Date: 17 February 2023 Federal Communications Commission (the “Commission” or “FCC”) Authorization and Evaluation Division 7435 Oakland Mills Rd. Columbia, MD 21046 RE: Attestation Statement Part 2.911(d)(7) – FCC: SWX Ubiquiti Inc. (“the Applicant”, FRN: 0012268215) certifies that, as of the date of this letter agreement, C T Corporation System is the Applicant’s designated U.S. agent for service of process for the above referenced grantee code. Applicant agrees to maintain an agent for no less than one year after (i) the Applicant has terminated all marketing and importation or (ii) the conclusion of any Commission-related proceeding involving the equipment certified by the FCC. C T Corporation System accepts, as of the date hereof, the obligation of the designated U.S. agent for service of process for the above referenced grantee code. Designated U.S. Agent Information: Name: C T Corporation System Address: 1015 15th Street N.W., Suite 1000, Washington, D.C., 20005 Email: [email protected] Sincerely, Ubiquiti Inc. C T Corporation System Alex Macon Denise Bell, Assistant Secretary By:

Cover Letter(s)

www.ui.com Date: 2/9/2023 TIMCO Engineering, Inc. 849 N.W. State Road 45 P.O. Box 370 Newberry, Florida 32669 RE: Request for Confidentiality In reference to the application under FCC ID: SWX-WAVEPRO, and pursuant to Sections 0.457(d)1(ii) and 0.459 of the Commission’s Rules, Ubiquiti Networks hereby requests permanent confidential treatment of the accompanying information as outlined below: Block Diagram Schematics Theory of Operation Software Security Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to Ubiquiti Networks and provide unjustified benefits to its competitors. In addition to the above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the important rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short term confidentiality on the following attachments until 180 days from grant date. External Photos Internal Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondence during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Ubiquiti Networks understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Alex Macon Ubiquiti lnc. Compliance Manager

Cover Letter(s)

www.ui.com Power of Attorney Date: May 8, 2022 Dear Sir or Madam, I hereby have entrusted the following individuals and entity to be an authorized agent regarding application for Type Certification. Ubiquiti Inc. also authorizes the following individuals and entity to be a proxy to handle all certification matters. Clay Allred Joseph W. Jackson Richard L. Winter Tyler Parry Kimberly Rodriguez Tanner Langley Unified Compliance Laboratories Address : 427 W 128000 South Draper Utah 84020 e-mail : [email protected] Applicant : Ubiquiti Inc. Address : 685 Third Avenue, New York NY 10017 United States Of America Sincerely, Alex Macon Ubiquiti, lnc. Compliance Manager

External Photos

427 West 12800 South, Draper, UT 84020 Photograph 1: Front View of DUT Photograph 2: Back View of DUT 427 West 12800 South, Draper, UT 84020 Photograph 3: Right View of DUT Photograph 4: Top View of DUT 427 West 12800 South, Draper, UT 84020 Photograph 5: Left View of DUT Photograph 6: Bottom Top View of DUT 427 West 12800 South, Draper, UT 84020 Photograph 7: Close Up of RJ45 Connector – Cover Removed

Internal Photos

427 West 12800 South, Draper, UT 84020 Photograph 1: Front View of DUT With Front Cover Off Showing Reflector Photograph 2: Front View of DUT With Reflector Removed 427 West 12800 South, Draper, UT 84020 Photograph 3: Front View of DUT With 5 GHz Antenna Board Removed Photograph 4: Front View of DUT With 60 GHz Board Removed 427 West 12800 South, Draper, UT 84020 60 GHz Antenna Photograph 5: Front View of DUT With Heat Shield Removed Photograph 6: Front View of 60 GHz Printed Circuit Board 427 West 12800 South, Draper, UT 84020 5 GHz Antennas 5 GHz Antennas Photograph 7: Back View of 60 GHz Printed Circuit Board Photograph 8: Front View of the 5GHz Antenna Printed Circuit Board 427 West 12800 South, Draper, UT 84020 Photograph 9: Back View of the 5GHz Antenna Printed Circuit Board Photograph 10: Front View of the Main Printed Circuit Board – Cans On 427 West 12800 South, Draper, UT 84020 Bluetooth Antenna Photograph 11: Back View of the Main Printed Circuit Board Photograph 12: Front View of the Main Printed Circuit Board – Cans Off

RF Exposure Info

§ 15.407(f) Maximum Permissible Exposure Test Requirement(s): §15.407(f): U-NII devices are subject to the radio frequency radiation exposure requirements specified in §1.1307(b), §2.1091 and §2.1093 of this chapter, as appropriate. All equipment shall be considered to operate in a “general population/uncontrolled” environment. RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit: EUT’s operating frequencies @ UNII-1 5180 – 5240 MHz, UNII-2a 5260 – 5335 MHz, UNII-2c 5485 – 5710 MHz, UNII-3 5745 – 5825 MHz, 60 GHz 58320 – 69120 MHz, BLE 2402 – 2480 MHz, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R 2 or R = √(PG / 4S) where, S = Power Density (mW/cm 2 ) P = Power Input to antenna (mW) G = Antenna Gain (numeric value) R = Distance (cm) Test Results: FCC Frequency (MHz) Con. Pwr. (dBm) Con. Pwr. (mW) Ant. Gain (dBi) Ant. Gain numeric Pwr. Density (mW/cm 2 ) Limit (mW/cm 2 ) Margin Distance (cm) Result 2402* 6.61 4.58 2.0 1.59 0.00 1.0 -1.0 400 Pass 5240 24.89 308.32 22.0 158.49 0.00 1.0 -1.0 400 Pass 5260 7.98 6.28 22.0 158.49 0.00 1.0 -1.0 400 Pass 5710 7.92 6.19 22.0 158.49 0.00 1.0 -1.0 400 Pass 5720 27.57 571.48 22.0 158.49 0.00 1.0 -1.0 400 Pass 58320* 17.00 50.12 46.0 39810.72 0.99 1.0 -0.01 400 Pass *Simultaneous Transmission (Worse case): 0.99 1.0 -0.01 400 Pass The Wave-Pro may have simultaneously transmission of the Bluetooth and U-NII-1, or U-NII-3 or the 60 GHz transmitter. Asterisk notes the worst case of the possible simultaneously transmitter combinations. Simultaneously Transmitters Summed: + 0.00 (2.4 GHz Bluetooth) + 0.99 (60 GHz Transmitter) = 0.99 Limit of 1.0 – 0.99 (summed value) = -0.01 Margin The safe distance for SWX-WAVEPRO where Power Density is less than the MPE Limit listed above was found to be 400 cm.

Test Report

CONFIDENTIAL - INTERNAL USE ONLY [Wave-Pro] ant enna measurement 2022/11/24 Daniel Li CONFIDENTIAL - INTERNAL USE ONLY BT 1. Antenna type: printed PCB 111-01205-01 Z X Z Y Y X Peak gain (dBi) 2440MHz2 Z X Y CONFIDENTIAL - INTERNAL USE ONLY WiFi 1. Antenna type: Dish 117-03751 Peak gain (dBi) 5150MHz20.5 5500MHz21 5850MHz22 Z X Y CONFIDENTIAL - INTERNAL USE ONLY Wigig Az radiation pattern 1.Antenna type: Dish 311-04092 2.EIRP: 67 dBm 3.Gain: 46 dBi - INTERNAL USE ONLY [GPS] Sky Sky Peak gain (dBi) 1575MHz4.5 Z X Y 1. Antenna type: patch 117-03998-02 CONFIDENTIAL - INTERNAL USE ONLY Manu facturer: Ubiquiti Inc. Address: 653 3rd Avenue #27 New York, NY 10017 United States

Test Report

427 West 12800 South Draper, UT 84020 Test Report Certification FCC ID SWX-WAVEPRO IC ID 6545A-WAVEPRO Equipment Under Test WAVE-PRO Test Report Serial Number TR7894_01 Date of Test(s) August 12, through September 22, 2022, and November 16 through November 18, 2022 Report Issue Date February 9, 2023 Test Specification Applicant 47 CFR FCC Part 15, Subpart C RSS-GEN Issue 5 Ubiquiti Inc. 685 Third Avenue, 27 th Floor New York, NY 10019 U.S.A. NVLAP LAB CODE 600241-0 427 West 12800 South, Draper, UT 84020 TR7894_Wave-Pro_15.255_01 Page 2 of 28 PROPRIETARY Certification of Engineering Report This report has been prepared by Unified Compliance Laboratory (UCL) to document compliance of the device described below with the requirement of Federal Communication Commissions (FCC) Part 15, Subpart C. This report may be reproduced in full. Partial reproduction of this report may only be made with the written consent of the laboratory. The results in this report apply only to the sample tested. Applicant Ubiquiti Inc. Manufacturer Ubiquiti Inc. Brand Name Wave Model Number WAVE-PRO FCC ID SWX-WAVEPRO IC ID 6545A-WAVEPRO On this 9 th day of February 2023, I individually and for Unified Compliance Laboratory certify that the statements made in this engineering report are true, complete, and correct to the best of my knowledge and are made in good faith. Although NVLAP has accredited the Unified Compliance Laboratory testing facilities, this report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the U.S. federal government. Unified Compliance Laboratory Written By: Clay Allred Reviewed By: Richard L. Winter 427 West 12800 South, Draper, UT 84020 TR7894_Wave-Pro_15.255_01 Page 3 of 28 PROPRIETARY Revision History Revision Description Date 01 Original Report Release February 9, 2023 427 West 12800 South, Draper, UT 84020 TR7894_Wave-Pro_15.255_01 Page 4 of 28 PROPRIETARY Table of Contents 1 Client Information ................................................................................................................................. 5 1.1 Applicant ....................................................................................................................................... 5 1.2 Manufacturer ................................................................................................................................. 5 2 Equipment Under Test (EUT) ............................................................................................................... 6 2.1 Identification of EUT .................................................................................................................... 6 2.2 Description of EUT ....................................................................................................................... 6 2.3 EUT and Support Equipment ........................................................................................................ 6 2.4 Interface Ports on EUT ................................................................................................................. 7 2.5 Operating Environment ................................................................................................................. 7 2.6 Operating Modes ........................................................................................................................... 7 2.7 EUT Exercise Software ................................................................................................................. 7 2.8 Block Diagram of Test Configuration .......................................................................................... 8 2.9 Modification Incorporated/Special Accessories on EUT .............................................................. 8 2.10 Deviation, Opinions Additional Information or Interpretations from Test Standard .................... 8 3 Test Specification, Method and Procedures .......................................................................................... 9 3.1 Test Specification .......................................................................................................................... 9 3.2 Methods & Procedures .................................................................................................................. 9 3.3 FCC Part 15, Subpart C .............................................................................................................. 10 3.4 Results ......................................................................................................................................... 10 3.5 Test Location .............................................................................................................................. 10 4 Test Equipment ................................................................................................................................... 11 4.1 Conducted Emissions at Mains Ports .......................................................................................... 11 4.2 Radiated Emissions ..................................................................................................................... 11 4.3 Equipment Calibration ................................................................................................................ 13 4.4 Meas urement Uncertainty ........................................................................................................... 13 5 Test Results ......................................................................................................................................... 14 5.1 §15.203 Antenna Requirements .................................................................................................. 14 5.2 E missions Bandwidth .................................................................................................................. 14 5.3 §15.255(c)(1)(i) Maximum Average Output Power ............…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Alex Macon
[email protected]385-200-1617Fax: 408-904-7556

Test Firm

Unified Compliance LaboratoryClay Allred
[email protected]801-530-9355

Technical Specifications

#Rule PartsFrequency RangePower Output
115C58.32 GHz - 69.12 GHz263.03 W
Confidentiality
Long Term
Grant Notes
Output Power listed is EIRP. Professional installation is required. This device must be installed and operated so as to provide a separation distance of at least 4 meters from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing.

Other Applications from Ubiquiti Inc.

SWX-USLGGH

SuperLink Gateway HA

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
SWX-UTRLR

Digital Transmission Radio

Aug 19, 2026

Equipment Class

DTS - Digital Transmission System
SWX-USLER

Recessed Entry Sensor

Aug 12, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
SWX-UVCG6ED

G6 Edge Dome

Jul 07, 2026

Equipment Class

DTS - Digital Transmission System
SWX-UVCG6ET

G6 Edge Turret

Jul 07, 2026

Equipment Class

DTS - Digital Transmission System