Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
XTREMERange5 OEM INTEGRATION GUIDE Carrier-Class 5GHz 802.11a Radio Module TECHNICAL SPECIFICATIONS XTREMERange5 DataRateAvg.PowerToleranceDataRateSensitivityTolerance 6Mbps28 dBm+/-1.5dB6Mbps-94 dBm+/-1.5dB 9Mbps28 dBm+/-1.5dB9Mbps-93 dBm+/-1.5dB 12Mbps28 dBm+/-1.5dB12Mbps-91 dBm+/-1.5dB 18Mbps28 dBm+/-1.5dB18Mbps-90 dBm+/-1.5dB 24Mbps28 dBm+/-1.5dB24Mbps-86 dBm+/-1.5dB 36Mbps26 dBm+/-1.5dB36Mbps-83 dBm+/-1.5dB 48Mbps24 dBm+/-1.5dB48Mbps-77 dBm+/-1.5dB 54Mbps23 dBm+/-1.5dB54Mbps-74 dBm+/-1.5dB DataRateCurrent ToleranceDataRateCurrent Tolerance 6Mbps1.80 A+/-100 mA6Mbps300 mA+/-100 mA 9Mbps1.80 A+/-100 mA9Mbps300 mA+/-100 mA 12Mbps1.80 A+/-100 mA12Mbps300 mA+/-100 mA 18Mbps1.80 A+/-100 mA18Mbps300 mA+/-100 mA 24Mbps1.80 A+/-100 mA24Mbps300 mA+/-100 mA 36Mbps1.50 A+/-100 mA36Mbps300 mA+/-100 mA 48Mbps1.30 A+/-100 mA48Mbps300 mA+/-100 mA 54Mbps1.10 A+/-100 mA54Mbps300 mA+/-100 mA Indoor (Antenna Dependent): Outdoor (Antenna Dependent): CARD INFORMATION Radio Operation IEEE 802.11a, 5GHz Interface32-bit mini-PCI Type IIIA Operation Voltage3.3VDC Antenna PortsSingle MMCX Temperature Range -40C to +80C (extended temp version up to +95C) SecurityWPA, WPA2, AES-CCM & TKIP Encryption, 802.1x, 64/128/152bit WEP Data Rates6Mbps, 9Mbps, 12Mbps, 24Mbps, 36Mbps, 48Mbps. 54Mbps RoHS ComplianceYES REGULATORY INFORMATION Wireless Modular ApprovalsFCC Part 15.247 (23dBi Antenna), IC RS210, CE with Notified Body Number RADIO OPERATING FREQUENCY 5.20-5.825GHz TX SPECIFICATIONSRX SPECIFICATIONS Up to 150meters 802.11a OFDM 802.11a OFDM Over 50km 40MHz (Turbo)20MHz10MHz5MHz ADJUSTABLE CHANNEL SIZE SUPPORT (Increase Channel Capacity or Increase Throughput) RANGE PERFORMANCE RX CURRENT CONSUMPTIONTX CURRENT CONSUMPTION 802.11a OFDM 802.11a OFDM CURRENT CONSUMPTION INFORMATION DRIVER INFORMATION Operating System SupportLinux MADWIFI, WindowsXP, Windows2000 For help with MADWIFI or other Special Driver Support, Please e-mail [email protected] ChipsetAtheros, 6th Generation, AR5414 with SuperA/Turbo Support TX Channel Width Support5MHz / 10MHz / 20MHz / 40MHz Advanced Mobility / QuickHandoffWindowsXP/2000 Utility with Enhanced Mobility Driver from Ubiquiti Cisco SupportCCX 4.0 Certified Driver/Utility also available from Ubiquiti MECHANICAL DIMENSIONS 495-499 Montague Expwy. Milpitas, CA 95035 San Jose, CA 95112 T (408)-942-3085 F (408)-351-4973 http://www.ubnt.com XTREMERange5
Ubiquiti Networks, Inc. 495-499 Montague Expwy. Milpitas, CA 95035 Attn:Reviewing Engineer MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize MET Laboratories, Inc. to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, 5/20/06 Robert J. Pera Senior RF Engineer
Ubiquiti Networks, Inc. 495-499 Montague Expwy Milpitas, CA 95035 2/6/07 Attn: MET laboratories 914 West Patapsco Ave. Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR SuperRange4 (FCC ID: SWX-XR5) To Whom It May Concern: This letter serves as an official request for confidentiality under FCC Rule Section 0.459. We have requested that the schematics, block diagrams, Bill of Materials, tune-up procedure, and theory of operation required to be submitted with this application be withheld from public review. These documents contain proprietary information that would sacrafice our competitive advantage in the marketplace if made public. Please contact me if there is any information you may need. Sincerely, Robert J. Pera Senior RF Engineer
Ubiquiti Networks, Inc. 495-499 Montague Expwy Milpitas, CA 95035 September 27, 2007 Dear Application Examiner, Ubiquiti Networks FCC ID: SWX-XR5, would like to have your authorization as a modular approval specific to Mini PCI module. The requirements of Public Notice DA00-1407 have been met and shown on the following statements. 1. “The modular transmitter must have its own RF shielding.”: Device is equipped with metal shielding to cover RF section. Refer to external photos 2. “The modular transmitter must have buffered modulation/data inputs.”: All inputs to the modules are buffered through logic or microprocessor inputs. 3. “The modular transmitter must have its own power supply regulation.”: Internal 2.5V/3.3V power regulator. Refer to block diagram. 4. “The modular transmitter must comply with the antenna requirements of section 15.203 and 15.204(C).”: The device is equipped with a unique antenna connector. Refer to external photos. 5. “The modular transmitter must be tested in a stand-alone configuration”: The device was tested in an adapter which exposed it outside that of a host laptop. 6. “The modular transmitter must be labeled with its own FCC ID number.”: There is one FCC ID submitter. A second FCC ID will be obtained by OEM customers for use in their hosts. 7. “The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements.”: There are specific EEPROM settings inside the module that prohibit illegal usage. 8. “The modular transmitter must comply with any applicable RF exposure requirements.”: The module is NOT a portable device for laptops. Can only be used in mobile applications. Please contact me if you have any further questions. Regards, Robert J. Pera Senior RF Engineer
MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 October 2, 2007 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 RE: Ubiquiti Networks, FCC ID: SWX-XR5 To Whom It May Concern: MET Laboratories, Inc. would like to request the above FCC ID be placed in audit mode so that we may upload the Modular Approval Letter exhibit. The Modular Approval Letter was inadvertently left out of the original e-filing. The grants notes will be updated to reflect the Modular Approval. If you need any additional information, please let me know. Thank you, Jennifer Sanchez TCB Administrator MET Laboratories, Inc., Santa Clara, CA 408-213-2359 [email protected] [email protected]
MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 June 12, 2008 Federal Communication Commission 445 12 th Street, SW Washington, DC 20554 Reference: FCC ID: SWX-XR5 To Whom It May Concern: MET Laboratories, Inc. would like to request that the Test Report and MPE Calculation be superseded on the behalf of the applicant, Ubiquiti Networks. The original test report listed an incorrect Antenna in Section 15.203. All of test photos show the correct antenna. The documents have no effect on the original grant. If you have any questions regarding this application, please feel free to contact me. Docuements to be superseded: Test Report, MPE Calculation Sincerely, Jennifer Warnell TCB Administrator/Documentation MET Laboratories, Inc. Office: 410-949-1877 Fax: 410.354.3313 [email protected]
FCCID: SWX-XR5IC: 6545A-XR5
Microcom 58EP23 23dBi Panel RadioWaves SP1.5 (2/3) -5.8 Gain: 31.4 dBi
Electromagnetic Compatibility Ubiquiti Networks Intentional Radiators XR5 CFR Title 47, Part 15, Subpart C MET Report: EMCS21035C-FCC247_REV1 © 2008, MET Laboratories, Inc. Electromagnetic Compatibility Criteria for Intentional Radiators § 15.247(b) Peak Power Output and RF Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 5745-5825 MHz ; highest conducted power = 29.98dBm (peak) therefore, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 EUT maximum antenna gain = 31.4 dBi Dish Antenna Power Density Determination: S = PG / 4πR 2 or R = √(PG / 4πS) where, S = Power Density (1 mW/cm 2 ) P = Linear Power Input to antenna (995.4) G = Numerical Antenna Gain (1380.4) R = Radius (20cm) R = (995.4*1380.4/4π) 1/2 = (1374050.1/12.56) 1/2 = 330.75cm separation required to meet Uncontrolled RF exposure limit of 1 mW/cm 2 MPE Limit Calculation: EUT’s operating frequencies @ 5745-5825 MHz ; highest conducted power = 29.98dBm (peak) therefore, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 EUT maximum antenna gain = 23dBi Panel Antenna Power Density Determination: S = PG / 4πR 2 or R = √(PG / 4πS) where, S = Power Density (1 mW/cm 2 ) P = Linear Power Input to antenna (995.4) G = Numerical Antenna Gain (199.5) R = Radius (20cm) R = (995.4*199.5/4π) 1/2 = (198609.5/12.56) 1/2 = 125.75cm separation required to meet Uncontrolled RF exposure limit of 1 mW/cm 2
MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 33439 WESTERN AVENUE ! UNION CITY, CALIFORNIA 94587-3201 ! PHONE (510) 489-6300 ! FAX (510) 489-6372 MET Report: EMCS21035C-FCC247_REV1 © 2008, MET Laboratories, Inc. Page ii of vii Electromagnetic Compatibility Criteria Test Report For the Ubiquiti Networks Model XR5 Verified under The FCC Certification Rules Contained in Title 47 of the CFR, Part 15.247, Subpart C for Intentional Radiators MET Report: EMCS21035C-FCC247_REV1 May 2, 2008 Prepared For: Ubiquiti Networks 495-499 Montague Expressway Milpitas, CA 95035 Prepared By: MET Laboratories, Inc. 4855 Patrick Henry Dr., Building 6 Santa Clara, CA 95054 Electromagnetic Compatibility Ubiquiti Networks Cover Page XR5 CFR Title 47, Part 15, Subpart B & C MET Report: EMCS21035C-FCC247_REV1 © 2008, MET Laboratories, Inc. Page iii of vii Electromagnetic Compatibility Criteria Test Report For the Ubiquiti Networks Model XR5 Tested Under The FCC Certification Rules Contained in Title 47 of the CFR, Part 15.247, Subpart C For Intentional Radiators Shawn McMillen, Project Engineer Jennifer Sanchez Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Part 15.247, of the FCC Rules under normal use and maintenance. Tony Permsombut, Manager Electromagnetic Compatibility Lab Electromagnetic Compatibility Ubiquiti Networks Report Status Sheet XR5 CFR Title 47, Part 15, Subpart B & C MET Report: EMCS21035C-FCC247_REV1 © 2008, MET Laboratories, Inc. Page iv of vii Report Status Sheet Revision Report Date Reason for Revision ∅ January 15, 2007 Initial Issue. 1 May 2, 2008 Correct Antenna List (15.203 section) Electromagnetic Compatibility Ubiquiti Networks Table of Contents XR5 CFR Title 47, Part 15, Subpart B & C MET Report: EMCS21035C-FCC247_REV1 © 2008, MET Laboratories, Inc. Page v of vii Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview.............................................................................................................................................................4 B. References...........................................................................................................................................................5 C. Test Site ..............................................................................................................................................................6 D. Description of Test Sample.................................................................................................................................6 E. Equipment Configuration....................................................................................................................................9 F. Support Equipment .............................................................................................................................................9 G. Ports and Cabling Information ..........................................................................................................................10 H. Mode of Operation............................................................................................................................................10 I. Method of Monitoring EUT Operation .............................................................................................................10 J. Modifications ....................................................................................................................................................10 a) Modifications to EUT..................................................................................................................10 b) Modifications to Test Standard....................................................................................................10 K. Disposition of EUT ...........................................................................................................................................10 III. Electromagnetic Compatibility Criteria for Unintentional Radiators ..............................................................11 § 15.107(a) Conducted Emissions Limits.............................................................................................................. 12 § 15.109(a) Radiated Emission Limits .................................................................................................................. 17 § 15.09(a) Radiated Emissions Limits................................................................................................................... 17 IV. Electromagnetic Compatibility Criteria for Intentional Radiators ...................................................................20 § 15.203 Antenna Requirement ............................................................................................................................. 21 § 15.…
Text truncated - open the document above for the full version.
Electromagnetic Compatibility Ubiquiti Networks Intentional Radiators XR5 CFR Title 47, Part 15, Subpart C MET Report: EMCS21035C-FCC247 © 2007, MET Laboratories, Inc. Page 33 of 63 Photograph 3. Test Equipment and setup for various Radiated Measurements Parabolic Antenna Photograph 5. Test Equipment and setup for various Radiated Measurements Panel Antenna
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 5.75 GHz - 5.83 GHz | 995.00 mW |
SuperLink Gateway HA
Equipment Class
DTS - Digital Transmission SystemDigital Transmission Radio
Equipment Class
DTS - Digital Transmission SystemRecessed Entry Sensor
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterG6 Edge Dome
Equipment Class
DTS - Digital Transmission SystemG6 Edge Turret
Equipment Class
DTS - Digital Transmission System