Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
USER MANUAL V0.8 EnOcean GmbH Kolpingring 18a 82041 Oberhaching Germany Phone +49.89.67 34 689-0 Fax +49.89.67 34 689-50 [email protected] www.enocean.com Subject to modifications PTM 33x / 33xC User Manual V0.8 May 10, 2010 10:54 AM Page 1/20 Patent protected: WO98/36395, DE 100 25 561, DE 101 50 128, WO 2004/051591, DE 103 01 678 A1, DE 10309334, WO 04/109236, WO 05/096482, WO 02/095707, US 6,747,573, US 7,019,241 Observe precautions! Electrostatic sensitive devices! Transmitter Module PTM 33x / 33xC May 4, 2010 USER MANUAL V0.8 © 2009 EnOcean | www.enocean.com PTM 33x / 33xC User Manual V0.8 | Page 2/20 PTM 33X / 33XC REVISION HISTORY The following major modifications and improvements have been made to the first version of this document: No Major Changes Published by EnOcean GmbH, Kolpingring 18a, 82041 Oberhaching, Germany www.enocean.com, [email protected], phone ++49 (89) 6734 6890 © EnOcean GmbH All Rights Reserved Important! This information describes the type of component and shall not be considered as assured characteristics. No responsibility is assumed for possible omissions or inaccuracies. Circuitry and specifications are subject to change without notice. For the latest product specifica- tions, refer to the EnOcean website: http://www.enocean.com. As far as patents or other rights of third parties are concerned, liability is only assumed for modules, not for the described applications, processes and circuits. EnOcean does not assume responsibility for use of modules described and limits its liability to the replacement of modules determined to be defective due to workmanship. Devices or systems containing RF components must meet the essential requirements of the local legal authorities. The modules must not be used in any relation with equipment that supports, directly or indirectly, human health or life or with applications that can result in danger for people, animals or real value. Components of the modules are considered and should be disposed of as hazardous waste. Local government regulations are to be observed. Packing: Please use the recycling operators known to you. By agreement we will take pack- ing material back if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or that we are not obliged to accept, we shall have to in- voice you for any costs incurred. USER MANUAL V0.8 © 2009 EnOcean | www.enocean.com PTM 33x / 33xC User Manual V0.8 | Page 3/20 PTM 33X / 33XC TABLE OF CONTENT 1 GENERAL DESCRIPTION ............................................................................... 4 1.1 Basic Functionality....................................................................................... 4 1.2 Technical Data ............................................................................................ 4 1.3 Physical Dimensions .................................................................................... 5 1.4 Environmental Conditions ............................................................................. 6 1.5 Ordering Information ................................................................................... 6 2 FUNCTIONAL DESCRIPTION .......................................................................... 6 2.1 Block diagram............................................................................................. 6 2.2 Pin out....................................................................................................... 7 2.3 Pin Description and operational characteristics................................................. 7 2.4 Configuration Interface ................................................................................ 8 2.5 Absolute maximum ratings (non operating)..................................................... 9 2.6 Maximum Ratings (operating) ....................................................................... 9 2.7 Radio telegram ..........................................................................................10 2.7.1 Normal operation....................................................................................10 2.7.2 User defined operation ............................................................................11 2.8 Transmit timing..........................................................................................11 3 APPLICATIONS INFORMATION ......................................................................12 3.1 How to connect an energy harvester .............................................................12 3.2 How to generate an equivalent energy pulse ..................................................12 3.3 Antenna ....................................................................................................13 3.4 Layout recommendations.............................................................................14 3.5 Soldering information PTM 332/332C ............................................................15 3.6 Transmission range ....................................................................................16 4 AGENCY CERTIFICATIONS (in preparation) ....................................................17 4.1 CE approval ...............................................................................................17 4.2 FCC (United States) Certification ..................................................................18 4.3 IC (Industry Canada) Certification.................................................................20 USER MANUAL V0.8 © 2009 EnOcean | www.enocean.com PTM 33x / 33xC User Manual V0.8 | Page 4/20 PTM 33X / 33XC 1 GENERAL DESCRIPTION 1.1 Basic Functionality The radio transmitter module PTM 330 from EnOcean enables the implementation of wireless sensors and switches without batteries. Key applications are handheld remote controls or indus- trial switches. Functional Principle When an energy pulse is supplied (e.g. by ECO 200 from EnOcean) an RF telegram is transmitted including a u…
Text truncated - open the document above for the full version.
EnOcean GmbH Kolpingring 18a 82041 Oberhaching Germany Phone +49.89.67 34 689-0 Fax +49.89.67 34 689-50 [email protected] www.enocean.com Managing Directors: Markus Brehler, Uwe Thumm Registered Court Munich HRB 139781 VAT Reg.No. DE813355588 Account: HypoVereinsbank München No. 2440610 Bank Code 700 202 70 EnOcean GmbH Kolpingring 18a 82041 Oberhaching/Germany Dr. Wolfgang Heller Product Line Manager Phone +49.89.67 34 689-34 Fax +49.89.67 34 689-55 Mobile +170.855 92 64 [email protected] OEM Agreement Governing use of EnOcean Limited Modular Approval PTM330C / PTM332C This Agreement (the “Agreement ”), is made and entered into as of ________, 2010 (the “Effective Date ”) by and between EnOcean GmbH with its principal place of business located at Kolpingring 18a, D-82041 Oberhaching, Germany (“EnOcean ”), and ____________________________, a _______________ with its principal place of business located at _____________, hereinafter referred to as “PARTY” or “PARTIES” respectively. NOW, THEREFORE, in consideration of the foregoing and of the mutual covenants, promises and agreements contained in the following provisions, and intending to be legally bound by this Agreement, the Parties agree as follows: LIMITED MODULAR APPROVAL EnOcean RF modules, approved for Limited Modular use, operate as intentional transmitting devices with respect to 47 CFR 15.231(a-c) and are limited to OEM installation. The modules are optimized to operate using small amounts of harvested energy, and may be powered by a small solar cell exposed to ambient light or a battery. The module transmits short radio packets comprised of control signals, (in some cases the control signal may be accompanied with data) such as those used with alarm systems, door openers, remote switches, and the like. The module does not support continuous streaming of voice, video, or any other forms of streaming data; it sends only short packets containing control signals and possibly data. The module is designed to comply with, has been tested according to 15.231(a-c), and has been found to comply with each requirement. Thus, a finished device containing an EnOcean radio module can be operated in the United States and Canada without additional FCC/IC approval (approval(s) for unintentional radiators may be required Date: April 19, 2010 Page: 1 EnOcean GmbH Kolpingring 18a 82041 Oberhaching Germany Phone +49.89.67 34 689-0 Fax +49.89.67 34 689-50 [email protected] www.enocean.com Management: Markus Brehler, Uwe Thumm Registered Court Munich HRB 139781 VAT Reg No. DE813355588 Account: HypoVereinsbank München No. 2440610 Bank Code 700 202 70 Date: April 19, 2010 Page: 2 for the OEM’s finished product), under EnOcean’s FCC ID number. This greatly simplifies and shortens the design cycle and development costs for OEM integrators. The module can be triggered manually or automatically, which cases are described below. Manual Activation The radio module can be configured to transmit a short packetized control signal if triggered manually. The module can be triggered by pressing a switch, for example. The packet contains one (or more) control signals that is (are) intended to control something at the receiving end. The packet may also contain data. Depending on how much energy is available from the energy source, subsequent manual triggers can initiate the transmission of additional control signals. This may be necessary if prior packet(s) was (were) lost due to fading or interference. Subsequent triggers can also be initiated as a precaution if any doubt exists that the first packet didn’t arrive at the receiver. Each packet that is transmitted, regardless of whether it was the first one or a subsequent one, will only be transmitted if enough energy is available from the energy source. Automatic Activation The radio module also can be configured to transmit a short packetized control signal if triggered automatically, by a relevant change of its inputs, for example. Again, the packet contains a control signal that is intended to control something at the receiving end and may also contain data. As above, it is possible for the packet to get lost and never reach the receiver. However, if enough energy is available from the energy source, and the module has been configured to do so, then another packet or packets containing the control signal may be transmitted at a later, unpredictable time. (I) FCC requirements: (a) In order to use the FCC/IC grant, the OEM must not operate or configure the module in such a way that the module will transmit more than 2 seconds telegrams per hour. (b) End users of products which contain the module must not have the ability to alter the firmware that governs the operation of the module. The agency grant is valid only when the module is incorporated into a final product by OEM integrators. EnOcean GmbH Kolpingring 18a 82041 Oberhaching Germany Phone +49.89.67 34 689-0 Fax +49.89.67 34 689-50 [email protected] www.enocean.com Management: Markus Brehler, Uwe Thumm Registered Court Munich HRB 139781 VAT Reg No. DE813355588 Account: HypoVereinsbank München No. 2440610 Bank Code 700 202 70 Date: April 19, 2010 Page: 3 (c) The end-user must not be provided with instructions to remove, adjust or install the module. The OEM must instruct the end user not to do so by providing appropriate written documentation (d) FCC labeling requirements: The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the final product. Attaching a label to a removable portion of the final product, such as a battery cover, is not permitted. The label must include the following text: Contains FCC ID: SZV-PTM33xC The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, including interfer…
Text truncated - open the document above for the full version.
External Photos (PTM33xC) Top View Bottom View
ID Label and Label Location (PTM330C / PTM332C) ID label Label location on module
External Photos (PTM33xC) Top View Bottom View
USER MANUAL V0.8 EnOcean GmbH Kolpingring 18a 82041 Oberhaching Germany Phone +49.89.67 34 689-0 Fax +49.89.67 34 689-50 [email protected] www.enocean.com Subject to modifications PTM 33x / 33xC User Manual V0.8 May 10, 2010 10:54 AM Page 1/20 Patent protected: WO98/36395, DE 100 25 561, DE 101 50 128, WO 2004/051591, DE 103 01 678 A1, DE 10309334, WO 04/109236, WO 05/096482, WO 02/095707, US 6,747,573, US 7,019,241 Observe precautions! Electrostatic sensitive devices! Transmitter Module PTM 33x / 33xC May 4, 2010 USER MANUAL V0.8 © 2009 EnOcean | www.enocean.com PTM 33x / 33xC User Manual V0.8 | Page 2/20 PTM 33X / 33XC REVISION HISTORY The following major modifications and improvements have been made to the first version of this document: No Major Changes Published by EnOcean GmbH, Kolpingring 18a, 82041 Oberhaching, Germany www.enocean.com, [email protected], phone ++49 (89) 6734 6890 © EnOcean GmbH All Rights Reserved Important! This information describes the type of component and shall not be considered as assured characteristics. No responsibility is assumed for possible omissions or inaccuracies. Circuitry and specifications are subject to change without notice. For the latest product specifica- tions, refer to the EnOcean website: http://www.enocean.com. As far as patents or other rights of third parties are concerned, liability is only assumed for modules, not for the described applications, processes and circuits. EnOcean does not assume responsibility for use of modules described and limits its liability to the replacement of modules determined to be defective due to workmanship. Devices or systems containing RF components must meet the essential requirements of the local legal authorities. The modules must not be used in any relation with equipment that supports, directly or indirectly, human health or life or with applications that can result in danger for people, animals or real value. Components of the modules are considered and should be disposed of as hazardous waste. Local government regulations are to be observed. Packing: Please use the recycling operators known to you. By agreement we will take pack- ing material back if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or that we are not obliged to accept, we shall have to in- voice you for any costs incurred. USER MANUAL V0.8 © 2009 EnOcean | www.enocean.com PTM 33x / 33xC User Manual V0.8 | Page 3/20 PTM 33X / 33XC TABLE OF CONTENT 1 GENERAL DESCRIPTION ............................................................................... 4 1.1 Basic Functionality....................................................................................... 4 1.2 Technical Data ............................................................................................ 4 1.3 Physical Dimensions .................................................................................... 5 1.4 Environmental Conditions ............................................................................. 6 1.5 Ordering Information ................................................................................... 6 2 FUNCTIONAL DESCRIPTION .......................................................................... 6 2.1 Block diagram............................................................................................. 6 2.2 Pin out....................................................................................................... 7 2.3 Pin Description and operational characteristics................................................. 7 2.4 Configuration Interface ................................................................................ 8 2.5 Absolute maximum ratings (non operating)..................................................... 9 2.6 Maximum Ratings (operating) ....................................................................... 9 2.7 Radio telegram ..........................................................................................10 2.7.1 Normal operation....................................................................................10 2.7.2 User defined operation ............................................................................11 2.8 Transmit timing..........................................................................................11 3 APPLICATIONS INFORMATION ......................................................................12 3.1 How to connect an energy harvester .............................................................12 3.2 How to generate an equivalent energy pulse ..................................................12 3.3 Antenna ....................................................................................................13 3.4 Layout recommendations.............................................................................14 3.5 Soldering information PTM 332/332C ............................................................15 3.6 Transmission range ....................................................................................16 4 AGENCY CERTIFICATIONS (in preparation) ....................................................17 4.1 CE approval ...............................................................................................17 4.2 FCC (United States) Certification ..................................................................18 4.3 IC (Industry Canada) Certification.................................................................20 USER MANUAL V0.8 © 2009 EnOcean | www.enocean.com PTM 33x / 33xC User Manual V0.8 | Page 4/20 PTM 33X / 33XC 1 GENERAL DESCRIPTION 1.1 Basic Functionality The radio transmitter module PTM 330 from EnOcean enables the implementation of wireless sensors and switches without batteries. Key applications are handheld remote controls or indus- trial switches. Functional Principle When an energy pulse is supplied (e.g. by ECO 200 from EnOcean) an RF telegram is transmitted including a u…
Text truncated - open the document above for the full version.
This document was signed electronically. The Center for Quality Engineering of SGS Germany GmbH is accredited by DATech for COMPONENTS TESTING ENVIRONMENTAL ENGINEERING ELECTROMAGNETIC COMPATIBILITY PRODUCT SAFETY TELECOM CONFORMANCE TESTS SGS Germany GmbH, SGS CQE, Hofmannstr. 50, D-81379 München, Phone +49 89-787475-130, Fax +49 89-787475-122, Internet www.sgs-cqe.de The test report shall not be reproduced except in full without the written approval of the testing laboratory DAT-P-002/91-02 Center for Quality Engineering Test Report No.: D0GB0001 FCC ID: SZV-PTM33XC IC ID: 5713A-PTM33XC Order No.: D0GB Pages: 33 Munich. Jul 15, 2010 Client: EnOcean GmbH Equipment Under Test: Transmitter Module PTM330C/PTM332C Manufacturer: EnOcean GmbH Task: Conformance test according to the test specifications mentioned below Test Specification(s): FCC 47 CFR Part 15 IC RSS-210 Result: The EUT complies with the requirements of the specification. The results relate only to the items tested as described in this test report. approved by: Date Signature Neuhäusler Lab Manager Wireless & Software Jul 15, 2010 Bauer Lab Manager EMC Jul 15, 2010 Test Report No.: D0GB0001 Date: Jul 15, 2010 Transmitter Module PTM330C/PTM332C page 2 / 33 The test report shall not be reproduced except in full without the written approval of the testing laboratory CONTENTS 1 Summary ..................................................................................................................................5 2 References ...............................................................................................................................6 2.1 Specifications ......................................................................................................................6 2.2 Glossary of Terms...............................................................................................................6 3 General Information ................................................................................................................7 3.1 Identification of Client..........................................................................................................7 3.2 Test Laboratory ...................................................................................................................7 3.3 Time Schedule ....................................................................................................................7 3.4 Participants .........................................................................................................................7 4 Equipment Under Test ............................................................................................................8 4.1 Description of EUT ..............................................................................................................8 4.2 Configuration of EUT...........................................................................................................9 4.3 Operating Conditions ..........................................................................................................9 4.4 Compliance Criteria.............................................................................................................9 5 General Description of Tests................................................................................................10 5.1 Tested Carrier Frequencies ..............................................................................................10 5.2 Calibration of the Test Equipment.....................................................................................10 6 Test Results ...........................................................................................................................11 6.1 Test No. 1: Conducted Emissions ([1] § 15.207) ..............................................................11 6.1.1 Purpose ......................................................................................................................11 6.1.2 Limits ..........................................................................................................................11 6.1.3 EUT Operating Condition ...........................................................................................11 6.1.4 Test Configuration ......................................................................................................11 6.1.5 Test Procedure and Results .......................................................................................12 6.1.6 Test Protocol ..............................................................................................................13 6.2 Test No. 2: Field strength correction for pulse operation (Duty Cycle) ([1] § 15.35(c)) .....14 6.2.1 Purpose ......................................................................................................................14 6.2.2 Limits ..........................................................................................................................14 6.2.3 EUT Operating Condition ...........................................................................................14 6.2.4 Test Configuration ......................................................................................................14 6.2.5 Test Procedure and Results .......................................................................................15 6.2.6 Test Protocol ..............................................................................................................15 6.3 Test No. 3: Field strength of the fundamental wave ([1] § 15.231(b). [3] A1.1.2) .............17 6.3.1 Purpose ......................................................................................................................17 6.3.2 Limits ..........................................................................................................................17 Test Report No.: D0GB0001 Date: Jul 15, 2010 Transmitter …
Text truncated - open the document above for the full version.
The Center for Quality Engineering of SGS Germany GmbH is accredited by DATech for COMPONENTS TESTING ENVIRONMENTAL ENGINEERING ELECTROMAGNETIC COMPATIBILITY PRODUCT SAFETY TELECOM CONFORMANCE TESTS SGS Germany GmbH, SGS CQE, Hofmannstr. 50, D-81379 München, Phone +49 89-787475-130, Fax +49 89-787475-122, Internet www.sgs-cqe.de Test Setup Photos - Conducted Emissions (§ 15.207) - Field strength correction for pulse operation (Duty Cycle) (§ 15.35(c)) and - Emission Bandwidth (§ 15.231(c)) and - Transmit Duration (§ 15.231(a)): 2/3 - Field strength of the fundamental wave (§ 15.231(b)): - Radiated Emissions (30MHz – 1GHz) (§ 15.209, 231(b)): - Radiated Emissions (9kHz – 30MHz) (§ 15.209): 3/3 - Radiated Emissions (1GHz – 4GHz) (§ 15.209, 231(b)):
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 315 MHz | - |

Temperature and Humidity Sensor with transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Temperature and Humidity Sensor with transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Temperature and Humidity Sensor with transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Temperature and Humidity Sensor with transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
2.405GHz - 2.475GHz transmitter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter