
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
145175Strada Rapide Create harmony for your city Operation manual Strada Rapide Operation manual Ref: 145175 Original edition in French (ref. 145176) Translated into English in July 2005. Copyright 2005 Parkeon. All rights reserved. Parkeon reserves all proprietary rights relating to the contents of this document. Parkeon reserves all rights over usage, reproduction, representation, marketing, translation, adaptation or modification, and generally all rights over present and future utilisation by any means, for any purpose and in any territory, throughout the period of protection. All use of the contents of this document requires the prior written permission of Parkeon. Parkeon reserves the right to change data, drawings and descriptions without prior notice. Certain characteristics may vary according to customer requirements and do not represent a commitment by Parkeon. Parkeon UK Ltd. Membrain House Ferndown Industrial Estate Wimborne, Dorset BH21 7PP - United Kingdom Phone +44 1202 850927 - Fax +44 1202 850903 Parkeon Inc. 40 Twosome Drive, Unit 7 Moorestown NJ 08057 - USA Phone +1 856 234 8000 - Fax +1 856 234 7178 Parkeon S.A.S. Parc La Fayette, 6 rue Isaac Newton, 25075 Besançon Cedex 9 - France Phone +33 (0)3 81 54 56 00 – Fax +33 (0)3 81 54 49 96 Head office: Le Barjac, 1 boulevard Victor, 75015 Paris - France Phone +33 (0)1 58 09 81 10 – Fax +33 (0)1 58 09 81 26 Parkeon S.A.S au capital de 30.382.146 euros 444 719 272 R.C.S. Paris Printed in France. Strada Rapide - Operation manual 2 Contents 1. About this document..............................................................................5 2. Safety................................................................................................5 3. General..............................................................................................7 3.1 Dimensions and weight......................................................................9 3.2 Detailed description........................................................................10 4. Purchasing a parking ticket....................................................................12 5. Tickets..............................................................................................13 5.1 Standard parking ticket....................................................................13 5.2 Test tickets...................................................................................13 5.3 Power supply voltage ticket...............................................................13 5.4 Statistics ticket..............................................................................14 6. Coin collection....................................................................................15 6.1 Unlocking the collection trap door and replacing the cash box.....................15 6.2 Issuing a collection ticket and a collection report.....................................17 6.3 Emptying and preparing a full cash box.................................................17 6.4 Carrying and storing the cash box........................................................19 7. Opening / closing the housing door...........................................................20 7.1 Opening / closing with a mechanical lock..............................................20 7.2 Opening / closing with an electronic lock..............................................21 7.3 Closing the housing door...................................................................22 8. Replenishing supplies...........................................................................23 8.1 Ticket roll....................................................................................23 8.2 Batteries......................................................................................25 9. Programming interface..........................................................................27 9.1 Display module keypad description......................................................27 9.2 Use of the maintenance menu with the door closed..................................28 9.3 Basic programming functions..............................................................29 10. Warnings and failures........................................................................32 10.1 Green warning LED..........................................................................32 10.2 Red failure LED..............................................................................33 10.3 Removable cash box failure codes.......................................................34 11. Cleaning.........................................................................................35 11.1 Outer surfaces...............................................................................35 11.2 Inside of the housing........................................................................36 12. Troubleshooting...............................................................................37 Strada Rapide - Operation manual 3 Strada Rapide - Operation manual 4 D5137 1. About this document... This guide is intended for operating personnel. It describes the procedure and provides advice for the correct and efficient performance of routine operations (collections, replenishment of supplies etc.). 2. Safety Parkeon products are designed to minimise all risks to users and operators from electrical power supplies, high temperature, fires, mechanical injuries, radiation and chemicals. Parkeon products have CE mark. They comply with the following European directives: 93/68/EEC, 89/336/EEC (EMC) for all the versions and 73/23/EEC (LV) for the versions with mains or public lighting power supplies. Comply with the basic precautions below to ensure the safety of personnel and the environment. The list is not comprehensive and is only aimed at drawing your attention to the potential risks of poorly performed work and negligence: Electricity • All product servicing operations require appr…
Text truncated - open the document above for the full version.
MKL 05/018 Wifi kit Neops base terminals Operation manual WIFI kit - Neops base terminals - Operation manual 2 Original edition in French (ref. MKL 05/019) Translated into English in February 2006. Copyright 2006 Parkeon. All rights reserved. Parkeon reserves all proprietary rights relating to the contents of this document. Parkeon reserves all rights over usage, reproduction, representation, marketing, translation, adaptation or modification, and generally all rights over present and future utilisation by any means, for any purpose and in any territory, throughout the period of protection. All use of the contents of this document requires the prior written permission of Parkeon. Parkeon reserves the right to change data, drawings and descriptions without prior notice. Certain characteristics may vary according to customer requirements and do not represent a commitment by Parkeon. Parkeon UK Ltd. Membrain House Ferndown Industrial Estate Wimborne, Dorset BH21 7PP - United Kingdom Phone +44 1202 850927 - Fax +44 1202 850903 Parkeon Inc. 40 Twosome Drive, Unit 7 Moorestown NJ 08057 - USA Phone +1 856 234 8000 - Fax +1 856 234 7178 Parkeon S.A.S. Parc La Fayette, 6 rue Isaac Newton, 25075 Besançon Cedex 9 - France Phone +33 (0)3 81 54 56 00 – Fax +33 (0)3 81 54 49 96 Head office: Le Barjac, 1 boulevard Victor, 75015 Paris - France Phone +33 (0)1 58 09 81 10 – Fax +33 (0)1 58 09 81 26 Parkeon S.A.S au capital de 30.382.146 euros 444 719 272 R.C.S. Paris Printed in France. WIFI kit - Neops base terminals - Operation manual 3 Contents 1. ABOUT THIS DOCUMENT......................................................................................... 4 2. CHARACTERISTICS ..................................................................................................... 5 2.1 MAIN BOARD............................................................................................................... 5 2.2 SLAVE BOARD............................................................................................................. 6 2.3 DESCRIPTION OF FUNCTIONS....................................................................................... 7 WIFI kit - Neops base terminals - Operation manual 4 1. About this document... This document describes the operation of the Wifi kit: • Starting up, • operation, • maintenance, used to centralise Neops base terminals in Wifi. Reference ocument describing the configurations of centralised systems MKL 04/020 User manual of Parkfolio Neo On-Line Document ref. 141596 FCC Compliance Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Note: The manufacturer is not responsible for any radio or tv interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment. WIFI kit - Neops base terminals - Operation manual 5 2. Characteristics 2.1 Main board Socket A of rack's ribbon cable (for card reader and relay board) Earthing pins Socket B of rack's ribbon cable Main board protective cover On/off switch Battery socket Power sockets for peripherals Power socket 50-pin socket for display unit and keypad ribbon cable D4849 Datapack connector D4628 Centralisation connector Loader card connected to 20-pin socket Extraction lever Loader socket WIFI kit - Neops base terminals - Operation manual 6 2.2 Slave board The slave board is connected directly to the main board centralisation connector. Slave board + modem (top view) Slave board (bottom view) D5336 D5335 Antenna Connector Antenna connector Centralisation connector (for main board) Slave board Wifi Modem Antenna Adaptator WIFI kit - Neops base terminals - Operation manual 7 2.3 Description of functions 2.3.1 Installation and initialisation The slave board and modem are mounted on the main board. Make sure the antenna is properly. Function 80: modem initialisation. To initialise the modem, use on-site programming function 80 described below: 1. MODEM PRESENT YES: 1 NO: 2 Enter 1 to start initialising the modem. Modem initialisation: From that point on, the main board initialises the modem without any more user input. The main board displays progress of the initialisation stage: 2. PLEASE WAIT During this stage, the main board powers up the modem. 3. MODEM INITIALISATION During this stage, the modem sends initialisation. If the initialisation procedure fails at this point (message “Init. not completed”), that means the slave board is not answering the main board. If the procedure is completed correctly, the main board moves on to the next stage. WIFI kit - Neops base terminals - Operation manual 8 4. NETWORK REGISTRATION During this stage, the main board waits for the modem to register on the Wifi network. 1. If initialisation fails during this stage (message “Init. not completed”), that means that the modem cannot be registered on the Wifi network : check that the antenna is correctly connected to the modem and that the antenna cable is correctly screwed to the antenna adapter. 5. INITIALISATION COMPLETED When the main board displays this message, that means that the modem has been successfully initialised. Initialisation is used to: • check assembly in the terminal; • check that the modem is capable of registering with the network. That is why function 80 should be repeated every time, whenever: • a new kit is installed; • the kit is removed from then put back into the terminal; Once the modem has been initialised, it still needs initialising on the terminal: • call numbers: server-side IP address (function 44); • configuring whether or not alarms are sent to the server (function 42). WIFI kit - Neops base terminals - Operation manual 9 Programming Parkfolio Neo On-Line numbers (function 44) This function is used to …
Text truncated - open the document above for the full version.
Parc La Fayette 6 rue Isaac Newton 25075 Besançon cedex 9 - France Tél : +33 (0)3 81 54 56 00 Fax : + 33 (0)3 81 52 76 38 PARKEON · Siège Social : Centre d’Affaires Arc-en-Ciel · 15 rue de la Vanne · 92120 Montrouge · France Tél : +33 (0)1 46 00 42 50 · Fax : +33 (0)1 46 00 63 52 · www.parkeon.com · [email protected] S.A.S au capital de 30.382.146 euros · R.C.S. NANTERRE B 444 719 272 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 U.S.A. Subject : Request for withholding from public disclosure the schematic diagrams, parts list, operational description and system block diagrams pursuant to an application for certification. Applicant : PARKEON Product : Strada Neops Model : Strada Rapide WIFI FCC ID : T2XSTRADA-RAPIDE Dear Sir/Madam, We, PARKEON, would like to request that the following files: - T2X-STRADA-Schem.zip - T2X-STRADA-BlkDia.pdf - T2X-STRADA-PartsLst.zip - T2X-STRADA-OpDes.pdf submitted with the application for certification be withheld from public disclosure as per Section 0.459 of FCC Rules. This request is made under the provisions of Section 0.457(d) of the Commission’s Rules, and Section 552(b)(4) of the Freedom of Information Act. These sections authorize as a withholding from public inspection materials which would be privileged as a matter of law if retained by the person submitting them, and materials which would not customarily be released to the public by that person. If you have any queries, please do not hesitate to contact us by our TELEPHONE NO. : +33 381545007 Best Regards, Florian TREUVEY R&D Engineer PARKEON
Wifi kit on Strada MCB – External Pictures Wifi kit on Strada MCB Pictures of the equipment External Views Wifi kit on Strada MCB – External Pictures Copyright 2006 Parkeon. All rights reserved. Parkeon reserves all proprietary rights relating to the contents of this document. Parkeon reserves all rights over usage, reproduction, representation, marketing, translation, adaptation or modification, and generally all rights over present and future utilisation by any means, for any purpose and in any territory, throughout the period of protection. All use of the contents of this document requires the prior written permission of Parkeon. Parkeon reserves the right to change data, drawings and descriptions without prior notice. Certain characteristics may vary according to customer requirements and do not represent a commitment by Parkeon. Parkeon UK Ltd. Membrain House Ferndown Industrial Estate Wimborne, Dorset BH21 7PP - United Kingdom Phone +44 1202 850927 - Fax +44 1202 850903 Parkeon Inc. 40 Twosome Drive, Unit 7 Moorestown NJ 08057 - USA Phone +1 856 234 8000 - Fax +1 856 234 7178 Parkeon S.A.S. Parc La Fayette, 6 rue Isaac Newton, 25075 Besançon Cedex 9 - France Phone +33 (0)3 81 54 56 00 – Fax +33 (0)3 81 54 49 96 Head office: Le Barjac, 1 boulevard Victor, 75015 Paris - France Phone +33 (0)1 58 09 81 10 – Fax +33 (0)1 58 09 81 26 Parkeon S.A.S au capital de 30.382.146 euros 444 719 272 R.C.S. Paris Printed in France. Wifi kit on Strada MCB – External Pictures STRADA RAPIDE WiFi Wifi kit on Strada MCB – External Pictures INTEGRATION OF THE WiFi SYSTEM INTO THE STRADA RAPIDE MOTHERBOARD + WiFi DAUGHTERBOARD Wifi kit on Strada MCB – External Pictures POSITION OF THE FCC ID Wifi kit on Strada MCB – External Pictures MODELE OF THE FCC ID STICKER 42mm 20mm
Wifi kit on Strada MCB – ID label/Location information Wifi kit on Strada MCB ID label/Location information Wifi kit on Strada MCB – ID label/Location information Copyright 2006 Parkeon. All rights reserved. Parkeon reserves all proprietary rights relating to the contents of this document. Parkeon reserves all rights over usage, reproduction, representation, marketing, translation, adaptation or modification, and generally all rights over present and future utilisation by any means, for any purpose and in any territory, throughout the period of protection. All use of the contents of this document requires the prior written permission of Parkeon. Parkeon reserves the right to change data, drawings and descriptions without prior notice. Certain characteristics may vary according to customer requirements and do not represent a commitment by Parkeon. Parkeon UK Ltd. Membrain House Ferndown Industrial Estate Wimborne, Dorset BH21 7PP - United Kingdom Phone +44 1202 850927 - Fax +44 1202 850903 Parkeon Inc. 40 Twosome Drive, Unit 7 Moorestown NJ 08057 - USA Phone +1 856 234 8000 - Fax +1 856 234 7178 Parkeon S.A.S. Parc La Fayette, 6 rue Isaac Newton, 25075 Besançon Cedex 9 - France Phone +33 (0)3 81 54 56 00 – Fax +33 (0)3 81 54 49 96 Head office: Le Barjac, 1 boulevard Victor, 75015 Paris - France Phone +33 (0)1 58 09 81 10 – Fax +33 (0)1 58 09 81 26 Parkeon S.A.S au capital de 30.382.146 euros 444 719 272 R.C.S. Paris Printed in France. Wifi kit on Strada MCB – ID label/Location information STRADA RAPIDE WiFi Wifi kit on Strada MCB – ID label/Location information POSITION OF THE FCC ID, full view Wifi kit on Strada MCB – ID label/Location information POSITION OF THE FCC ID, zoomed view Wifi kit on Strada MCB – ID label/Location information MODELE OF THE FCC ID STICKER 42mm 20mm
Wifi kit on Strada MCB – FCC label sample Wifi kit on Strada MCB FCC label sample Wifi kit on Strada MCB – FCC label sample Copyright 2006 Parkeon. All rights reserved. Parkeon reserves all proprietary rights relating to the contents of this document. Parkeon reserves all rights over usage, reproduction, representation, marketing, translation, adaptation or modification, and generally all rights over present and future utilisation by any means, for any purpose and in any territory, throughout the period of protection. All use of the contents of this document requires the prior written permission of Parkeon. Parkeon reserves the right to change data, drawings and descriptions without prior notice. Certain characteristics may vary according to customer requirements and do not represent a commitment by Parkeon. Parkeon UK Ltd. Membrain House Ferndown Industrial Estate Wimborne, Dorset BH21 7PP - United Kingdom Phone +44 1202 850927 - Fax +44 1202 850903 Parkeon Inc. 40 Twosome Drive, Unit 7 Moorestown NJ 08057 - USA Phone +1 856 234 8000 - Fax +1 856 234 7178 Parkeon S.A.S. Parc La Fayette, 6 rue Isaac Newton, 25075 Besançon Cedex 9 - France Phone +33 (0)3 81 54 56 00 – Fax +33 (0)3 81 54 49 96 Head office: Le Barjac, 1 boulevard Victor, 75015 Paris - France Phone +33 (0)1 58 09 81 10 – Fax +33 (0)1 58 09 81 26 Parkeon S.A.S au capital de 30.382.146 euros 444 719 272 R.C.S. Paris Printed in France. Wifi kit on Strada MCB – FCC label sample MODELE OF THE FCC ID LABEL 42mm 20mm
Wifi kit on Strada MCB – Internal Pictures Wifi kit on Strada MCB Pictures of the equipment Electronic boards Wifi kit on Strada MCB – Internal Pictures Copyright 2006 Parkeon. All rights reserved. Parkeon reserves all proprietary rights relating to the contents of this document. Parkeon reserves all rights over usage, reproduction, representation, marketing, translation, adaptation or modification, and generally all rights over present and future utilisation by any means, for any purpose and in any territory, throughout the period of protection. All use of the contents of this document requires the prior written permission of Parkeon. Parkeon reserves the right to change data, drawings and descriptions without prior notice. Certain characteristics may vary according to customer requirements and do not represent a commitment by Parkeon. Parkeon UK Ltd. Membrain House Ferndown Industrial Estate Wimborne, Dorset BH21 7PP - United Kingdom Phone +44 1202 850927 - Fax +44 1202 850903 Parkeon Inc. 40 Twosome Drive, Unit 7 Moorestown NJ 08057 - USA Phone +1 856 234 8000 - Fax +1 856 234 7178 Parkeon S.A.S. Parc La Fayette, 6 rue Isaac Newton, 25075 Besançon Cedex 9 - France Phone +33 (0)3 81 54 56 00 – Fax +33 (0)3 81 54 49 96 Head office: Le Barjac, 1 boulevard Victor, 75015 Paris - France Phone +33 (0)1 58 09 81 10 – Fax +33 (0)1 58 09 81 26 Parkeon S.A.S au capital de 30.382.146 euros 444 719 272 R.C.S. Paris Printed in France. Wifi kit on Strada MCB – Internal Pictures MODEM DAUGHTER BOARD (TOP & BOTTOM VIEW) + MODEM DPAC WLNB-AN-DP101 Wifi kit on Strada MCB – Internal Pictures STRADA MOTHERBOARD + WiFi DAUGHTERBOARD Wifi kit on Strada MCB – Internal Pictures INTEGRATION OF THE WiFi SYSTEM INTO THE STRADA RAPIDE MOTHERBOARD + WiFi DAUGHTERBOARD + Fcc ID
Parc La Fayette 6 rue Isaac Newton 25075 Besançon cedex 9 - France Tél : +33 (0)3 81 54 56 00 Fax : + 33 (0)3 81 52 76 38 PARKEON · Siège Social : Centre d’Affaires Arc-en-Ciel · 15 rue de la Vanne · 92120 Montrouge · France Tél : +33 (0)1 46 00 42 50 · Fax : +33 (0)1 46 00 63 52 · www.parkeon.com · [email protected] S.A.S au capital de 30.382.146 euros · R.C.S. NANTERRE B 444 719 272 Declaration on radiation safety standard conformance Adress: PARKEON 6 rue Isaac Newtoon 25075 Besançon CEDEX 9 FRANCE Tél : +33 (0)3 81 54 56 00 Fax : + 33 (0)3 81 52 76 38 Declare that the following product: Description: ........Pay and display machine, wifi FCC ID: ..............T2XSTRADA-RAPIDE Manufacturer: ......PARKEON Brand: ...............STRADA NEOPS Type: ................STRADA RAPIDE WIFI Has an e.i.r.p less than 100mW 2 22 /02.0 )20(**4 100 **4 cmmW cm mW R EIRP PSD=== ππ (limit = 1.0mW/cm²) The equipment fulfills the requirements on power density for general population/uncontrolled exposure and therefore fulfills the requirements of FCC Part 15.247i, table 1 §1.1310. Sincerely,
EMITECH ATLANTIQUE 15, rue de la Claie Z.I. Angers-Beaucouzé 49070 BEAUCOUZÉ Tél. 02 41 73 26 27 Fax 02 41 73 26 40 e-mail : [email protected] R.C.S. ANGERS 95 B 543 SIRET 344 545 645 00055 SIEGE SOCIAL : EMITECH S.A. 3, rue des Coudriers – Z.A. de l’Observatoire – 78180 MONTIGNY-LE-BRETONNEUX – Tél. 01 30 57 55 55 – Fax 01 30 43 74 48 S.A. AU CAPITAL DE 480 000 € - R.C. VERSAILLES B 344 545 645 – SIRET 344 545 645 000 22 – CODE APE 742 C RA-06-24065-2/A Ed. 1 “This report cancels and replaces the test report n° RA-06-24065-2/A Edition 0” FCC CERTIFICATION RADIO Measurement Technical Report standard to apply: FCC Part 15 Equipment under test: PAY AND DISPLAY MACHINE “STRADA RAPIDE TM” FCC ID: T2XSTRADA-RAPIDE Company: PARKEON DISTRIBUTION: Mr TREUVEY Company: PARKEON Number of pages: 30 including 5 annexes Technical Verification Ed. Date ModifiedWritten by Quality Approval Pages Name Visa Name Visa 1 16-Feb-07 1 to 4, L. BERTHAUD 6 to 8, 10, 17 to 30 Duplication of this document is only permitted for an integral photographic facsimile. It includes the number of pages referenced here above. This document is the result of testing a specimen or a sample of the product submitted. It does not imply an assessment of the conformity of the whole manufactured products of the tested sample. 1 EMITECH ATLANTIQUE RA-06-24065-2/A Ed. 1 PAGE: 2 RA-06-24065-2-Ed1-A-ST PRODUCT: PAY AND DISPLAY MACHINE Reference / model : STRADA RAPIDE TM Serial number: MANUFACTURER: not communicated COMPANY SUBMITTING THE PRODUCT: Company : PARKEON Address : Parc La Fayette - 6, rue Isaac Newton 25075 BESANCON CEDEX 9 FRANCE Responsible : Mr TREUVEY DATE(S) OF TEST: 14, 15 and 16 February 2006 16 January 2007 TESTING LOCATION: EMITECH ATLANTIQUE laboratory at ANGERS (49) FRANCE EMITECH ATLANTIQUE open area test site in LA POUEZE (49) FRANCE Registration Number by FCC: 101696/FRN: 0006 6490 08 TESTED BY: L. BERTHAUD and C. GREGOIRE 1 EMITECH ATLANTIQUE RA-06-24065-2/A Ed. 1 PAGE: 3 RA-06-24065-2-Ed1-A-ST CONTENTS TITLE PAGE 1. INTRODUCTION.......................................................................................................................... 4 2. PRODUCT DESCRIPTION .........................................................................................................4 3. NORMATIVE REFERENCE....................................................................................................... 4 4. TEST METHODOLOGY .............................................................................................................5 5. ADD ATTACHMENTS FILES .................................................................................................... 5 6. TESTS AND CONCLUSIONS ..................................................................................................... 6 7. PEAK OUTPUT POWER............................................................................................................. 7 8. PEAK POWER DENSITY............................................................................................................ 9 9. RADIATED EMISSION ............................................................................................................. 11 10. MEASUREMENT OF THE CONDUCTED DISTURBANCES........................................... 13 Measurement on the mains power supply: .................................................................................. 14 ANNEX 1: CONDUCTED EMISSION ......................................................................................... 15 ANNEX 2: MINIMUM 6 dB BANDWIDTH ................................................................................ 17 ANNEX 3: BAND EDGE COMPLIANCE.................................................................................... 20 ANNEX 4: PHOTOS OF THE EQUIPMENT UNDER TEST ................................................... 25 ANNEX 5: OPEN AREA TEST SITE, TEST SET UP ................................................................ 29 1 EMITECH ATLANTIQUE RA-06-24065-2/A Ed. 1 PAGE: 4 RA-06-24065-2-Ed1-A-ST 1.INTRODUCTION This document presents the result of RADIO test carried out on the following equipment: PAY AND DISPLAY MACHINE “STRADA RAPIDE TM” in accordance with normative reference. 2.PRODUCT DESCRIPTION ITU Emission code: 13M0G7D Class: B (residential environment) Utilization: Pay and display machine with WIFI modem Antenna type: incorporated antenna Operating frequency range: from 2412 MHz to 2462 MHz Number of channels: 11 Channel spacing: 5 MHz Frequency generation: | SAW Resonator | Crystal ~ Synthetiser Modulation: Direct sequence spread spectrum | Amplitude ~ Digital | Frequency | Phase Power source: 115 Va.c. (mains supply) or 12 Vd.c. (battery supply) Power level, frequency range and channels characteristics are not user adjustable. The details pictures of the product and the circuit boards are joined with this file. 3.NORMATIVE REFERENCE The standards and testing methods related throughout this report are those listed below. They are applied on the whole test report even though the extensions (version, date and amendment) are not repeated. FCC Part 15 (2005) Code of Federal Regulations Title 47 - Telecommunication Chapter 1 - Federal Communications Commission Part 15 - Radio frequency devices Subpart C - Intentional Radiators ANSI C63.4 (03) American National Standard for Methods of measurement of Radio- Noise from low-voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. 1 EMITECH ATLANTIQUE RA-06-24065-2/A Ed. 1 PAGE: 5 RA-06-24065-2-Ed1-A-ST 4.TEST METHODOLOGY Radio performance tests procedures given in part 15: Paragraph 33: frequency range of radiated measurements Paragraph 35: measurement detector functions and bandwidths Paragraph 203: antenna requirement Paragraph 205: restricted bands of operation Paragraph 207: conducted limits Paragraph 209: radiated emission limits; general requirements Paragraph 247: operation within the bands 2400-2483.5 MHz 5.ADD A…
Text truncated - open the document above for the full version.
EMITECH ATLANTIQUE A5- PAGE: 1 Document2 ANNEX 5: OPEN AREA TEST SITE, TEST SET UP 1 EMITECH ATLANTIQUE A5- PAGE: 2 Document2 TEST SET UP CONDUCTED MEASUREMENT SET UP EMITECH ATLANTIQUE A5- PAGE: 3 Document2
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 100.00 mW |

contactless system of validation, payment or identification
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RFID READER
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter