T3W-E90-001Transceiver

Telemedic Inc.
Transceiver - FCC ID T3W-E90-001 - Telemedic Inc.
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Jun 14, 2006
Application Purpose
Original Equipment
Date of Application
Jun 14, 2006
Equipment Note
Transceiver
Frequency Range
916.48000000 - 916.48000000
Company
Telemedic Inc.
Country
Canada

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

ID Label/Location Info

LBL-10-002 Spécification d'étiquettage Page(1de3) Date : 21/03/06 Fichier : Q01-038 Rév: B Portée / Parent Nom du produit / assemblage / sous assemblage : Sous assemblage base de Communication E90 # de produit / assemblage / sous assemblage : 32-002 Contrôle des changements Rév Date Description Auteur A 070206 Première ébauche Sylvain Paradis B 210306 Modification de l’étiquette et ajout du positionnement Sylvain Paradis C 230306 Modification du numéro IC Sylvain Paradis Description de l’étiquetage L’étiquette suivante sert à identifier le produit de la base de communication E90. Cette étiquette sera placée sur le boîtier de l’unité. Le matériel utilisé doit être approuvé CSA. Dimensions: 2,00’’ x 4,00’’. Matériel Permaprint 3S (IMS) Contenu Les renseignements suivants doivent apparaître sur l’étiquette: Le nom de l’instrument (Modèle), nom et adresse du fabricant, l’identificateur (P/N), numéro de contrôle (S/N), code à barre du S/N, I.D. numéro unique de l’appareil. Numéro d’industrie Canada IC : 6418A-E90001 Numéro d’identification FCC FCC ID : T3W-E90-001 Logo CSAus et FCC Déclaration de conformité (DOC) Description du numéro de contrôle (numéro de série) Ex : 50050001 (LLAAUUUU) • LOT : (LL) deux décimales – Identification du lot de fabrication le numéro se réinitialise au début de chaque année. • Année de l’ordonnancement : (AA) deux décimales LBL-10-002 Spécification d'étiquettage Page(2de3) Date : 21/03/06 Fichier : Q01-038 Rév: B Contenu (suite) • Unité : (UUUU) quatre décimales – Numéro d’identification de l’unité. Le numéro est remis à un (1) pour chaque nouveau LOT. Les numéros de série attribués doivent être enregistrés dans une base donnée. Description de l’identificateur (P/N) 32-002 Modèle(s) fichier joint Labelview (lbl-10-002.lbl) Échantillon Apposer un échantillon de l’étiquette ci-dessous. LBL-10-002 Spécification d'étiquettage Page(3de3) Date : 21/03/06 Fichier : Q01-038 Rév: B Positionnement Le positionnement de l’étiquette doit être comme suit : Approbation Approuvé par : Date :

Test Report

FCC Part 15 Subpart C, 15.249 : August 2005 Test Report: 6W61089.4 Applicant: Telemedic Inc 6700 Av Choquette bur 200 St-Hyacinthe, Quebec J2S 8L1 Apparatus: Base de Communication E90 FCC ID: T3W-E90-001 In Accordance With: FCC Part 15 Subpart C, 15.249 Operation in the 902-928MHz, 2400 - 2483.5 MHz, 5725-5850MHz and 24.0-24.25 GHz Tested By: Nemko Canada Inc. 303 River Road Ottawa, Ontario K1V 1H2 Authorized By: Jin Xu, Wireless Specialist Date: May 4, 2006 Total Number of Pages: 19 Nemko Canada Inc. REPORT SUMMARY Report Number: 6W61089.4 FCC ID: T3W-E90-001 Specification: FCC Part 15 Subpart C, 15.249 Page 2 of 19 Report Summary These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with Part 15, Subpart C. Radiated tests were conducted in accordance with ANSI C63.4-2003. Radiated emissions are made on an open area test site. A description of the test facility is on file with the FCC. The assessment summary is as follows: Apparatus Assessed: Base de Communication E90 Specification: FCC Part 15 Subpart C, 15.249 Compliance Status: Complies Exclusions: None Non-compliances: None Report Release History: Original Release Author: Jason Nixon, Telecom Specialist Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. This test report has been completed in accordance with the requirements of ISO/IEC 17025. Nemko Canada Inc. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko Canada Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. Nemko Canada Inc. REPORT SUMMARY Report Number: 6W61089.4 FCC ID: T3W-E90-001 Specification: FCC Part 15 Subpart C, 15.249 Page 3 of 19 TABLE OF CONTENTS Report Summary......................................................................................................................................... 2 Section 1 : Equipment Under Test............................................................................................................. 4 1.1 Product Identification .................................................................................................................................4 1.2 Samples Submitted for Assessment............................................................................................................4 1.3 Theory of Operation ...................................................................................................................................4 1.4 Technical Specifications of the EUT ..........................................................................................................5 1.5 Block Diagram of the EUT.........................................................................................................................5 Section 2 : Test Conditions......................................................................................................................... 6 2.1 Specifications .............................................................................................................................................6 2.2 Deviations From Laboratory Test Procedures ............................................................................................6 2.3 Test Environment .......................................................................................................................................6 2.4 Test Equipment...........................................................................................................................................6 Section 3 : Observations ............................................................................................................................. 7 3.1 Modifications Performed During Assessment ............................................................................................7 3.2 Record Of Technical Judgements ...............................................................................................................7 3.3 EUT Parameters Affecting Compliance .....................................................................................................7 3.4 Test Deleted................................................................................................................................................7 3.5 Additional Observations .............................................................................................................................7 Section 4 : Results Summary ..................................................................................................................... 8 4.1 FCC Part 15 Subpart C : Test Results ........................................................................................................9 Appendix A : Test Results ........................................................................................................................ 10 Clause 15.215(c) 20dB Bandwidth ......................................................................................................................10 Clause 15.207(a) Powerline Conducted Emissions .............................................................................................11 Clause 15.249(a) Radiated emissions not in Restricted Bands ............................................................................16 Appendix B : Setup Photographs ............................................................................................................ 17 Appendix C : Block Diagram of Test Setups ................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emissions Setup: Spurious Emissions Setup:

Contact Information

Applicant

Andre Junior Richard(Electronic Department Supervisor)
[email protected]450-250-1414Fax: 450-250-1416

Technical Contact

Telemedic Inc.Sylvain Paradis
[email protected]450 250 1414

6700 Ave. Choquerre, Bureau 200 · St-Hyacinthe · Canada

Non-Technical Contact

Telemedic Inc.Sylvain Paradis
[email protected]450 250 1414

Test Firm

Nemko Canada Inc. (Ottawa)Charles Neal
[email protected]613-737-9680Fax: 613-737-9691

Technical Specifications

#Rule PartsFrequency RangePower Output
115C916.48 MHz - 916.48 MHz-
Confidentiality
Long Term

Other Applications from Telemedic Inc.

Multi-users, multi-sensors - FCC ID T3W-MUMS-002 - Telemedic Inc.
T3W-MUMS-002

Multi-users, multi-sensors

Jun 20, 2010

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Transceiver - FCC ID T3W-M93-XXX - Telemedic Inc.
T3W-M93-XXX

Transceiver

Jun 14, 2006

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Transceiver - FCC ID T3W-I9X-001 - Telemedic Inc.
T3W-I9X-001

Transceiver

Jun 14, 2006

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified