FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Farpointe Data Inc./
  3. T8I-CONEKT3

T8I-CONEKT3CONEKT MOBILE-READY PROXIMITY READERS

Farpointe Data Inc.
CONEKT MOBILE-READY PROXIMITY READERS - FCC ID T8I-CONEKT3 - Farpointe Data Inc.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jul 28, 2020
Application Purpose
Original Equipment
Date of Application
Jul 28, 2020
Equipment Note
CONEKT MOBILE-READY PROXIMITY READERS
Frequency Range
0.12500000 - 0.12500000
Company
Farpointe Data Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗
↗
↗

ID Label/Location Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

This Quick Start Guide is intended for experienced installing technicians. It is a basic reference to ensure all connections are properly made. Models include Conekt PCR-35-L, PCR-620 and PCR-640. For additional information please reference Farpointe Data’s website www.farpointedata.com. 1.0 Introduction A key component of a physical security electronic access control system, a mobile-ready reader combining BLE and proximity technologies is based on RFID technology. In operation it is capable of reading data stored on a proximity credential via radio frequency—or reading data from mobile credential stored in a smartphone’s wallet app via BLE technology—and without physical contact, and then passing the data obtained to the physical access control system. Access control systems typically manage and record the movement of individuals through a protected area, such as a locked door. 2.0 Mounting Provisions Each reader may be installed either indoors or outdoors. Mounting options shown in the table below. Use supplied #6 mounting screws, or equivalent security screws, for installation. PCR-35-LPCR-620PCR-640 Mullion Mount •• Single-gang Wall Mount* •• *Plastic or metal. 3.0 Reader Wiring WiegandMagstripe ConductorFunctionConductorFunction RedDC (8-14 VDC)RedDC (8-14 VDC) BlackGroundBlackGround GreenData 0GreenClock WhiteData 1WhiteData BrownRed LED a BrownRed LED OrangeGreen LED b OrangeGreen LED YellowCard PresentYellowCard Present BlueBeeperBlueBeeper VioletfleaPowerVioletfleaPower DrainShield GroundDrainShield Ground 4.0 Cable Requirements 24 AWG minimum, multi-conductor stranded with an overall foil shield, for example Belden 9535 or similar, supporting the five conductors comprising the physical layer of the Wiegand interface (power, ground, data 0, data 1, and/or beeper and LED). Alternatively, Belden 9539 or similar, for all reader functions. Contact your access control system manufacturer for their specific requirements. Per the SIA’s Wiegand specification, maximum cable length is 500 feet (152 m). 5.0 Output Formats Wiegand (industry standard 26-bit Wiegand and custom Wiegand formats) Magnetic Stripe (ABA Track II, clock and data, with card present) 6.0 Grounding Shield (drain) continuity must run from the reader to the access panel. Shield (drain) and reader ground must be tied together at the access panel and connect to an earth ground at one point. 7.0 Power Reader may be powered by the access panel. A linear power supply is recommended for best operation. QUICK START GUIDE CONEKT ® MOBILE-READY PROXIMITY READERS NOTES: a Single Line LED: This is the standard operating mode and does not make use of the Orange conductor. The LED is Red when the reader is idle and flashes when a card is presented. The LED turns Green when the Brown Conductor is pulled low by the access control panel. b Dual Line LED: This mode makes use of both the Brown and Orange conductors. The Brown conductor controls the Red LED and the Orange conductor controls the Green LED. LED states are determined by the access control system option and capability. Unused conductors should be trimmed, isolated and taped back to prevent unintended current flows. Apply positive voltage only to the Red DC Conductor. P/N: 01175-003 ∙ Rev. 01.20 © 2018-2020 Farpointe Data, Inc. All rights reserved. Farpointe Data ® , Pyramid Series Proximity ® , Delta ® , Ranger ® , and CONEKT ® are the registered U.S. trademarks of Farpointe Data, Inc. All other trademarks are the property of their respective owners. 8.0 Voltage 12 VDC at the reader is recommended for best operation. ModelPCR-35-LPCR-620PCR-640 Voltage8 to 14 VDC5 to 16 VDC5 to 16 VDC Current Draw40 mA typical, 195 mA peak70 mA typical, 110 mA peak70 mA typical, 110 mA peak 9.0 fleaPower™ Control Line To reduce the average current required by the reader, pull the purple conductor low. 10.0 Connection Connection must be done in accordance with NFPA 70. Do not connect to a receptacle controlled by a switch. Connect to a power limited DC voltage source. 11.0 Troubleshooting 1. When the reader is first powered on it will beep 4-times, and the LED will shine red. 2. Presenting a supported access credential will result in the reader beeping and the LED flashing once. 3. Mobile operation is optimized for smartphones supporting BLE (Bluetooth LE) version 4.2 or newer. Further, for the downloading of mobile access credentials, a stable, high-quality internet connection is recommended. NOTE: The access panel controls LED functionality, such as switching the LED to green. If the reader does not recognize the mobile credential or card or tag (no beep, no LED flash) or exhibits short read range, please see the table below for possible causes and solutions. Possible CauseCorrective Action Incorrect cablingVerify gauge, connections and cabling length Not enough power12 VDC recommended Incorrect credential usedVerify if credential technology is supported Reader/access panel not properly groundedEarth ground needed—verify shield and reader ground are tied at access panel and connect to ground at one point Supply generating interferenceLinear power supply recommended, verify switching power supply before use Should any of the corrective actions mentioned above not improve performance, disconnect the reader from the access panel and power it with a separate power supply or 9VDC battery, and re-test card functionality. By powering the readers separately, most variables that may lead to reduced performance can be eliminated. Should the problem persist, please contact Farpointe directly. Many Farpointe Data Readers carry the following certifications: QUICK START GUIDE CONEKT ® MOBILE-READY PROXIMITY READERS Farpointe Data, Inc. 2195 Zanker Road San Jose, CA 95131 USA Office: +1-408-731-8700 Fax: +1-408-731-8705 [email protected] www.farpointedata.com FCC Compliance Statement: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this …

Text truncated - open the document above for the full version.

External Photos

�� Farpointe Data" Readers� Credentials PCR-35 Rev 1 05562-333 111111 I IIIIII I II II I /11111111111111 httJ dc'VICC c� wch Part 15 of lhe FCC ruk.'!l Operation ; :w,cct lo the folowwig two coodibon:: (1)Thttl dew;c tTYil'f at caim: harmful rler!Cfcncc, And (2) tt., dew;c mum cccpt � 111t-rfCfcr,cc that fTYiJ'f cau:;c �cd opcral . .on -� FCC ID: T81-CONEKT3 � r} IC: 6S04A-CONEKT3 20210001 Pb-r, .. II 11111111111111111111 CE Input 12 VDC, 40-180mA Ii 111 l 1 i J . ' I ' ,_ . . J - ' _J I : I --.. ....---- --t � . J , l A I+. "r"\ 1""' 1 l; 1 . T· t .� - l · ��. ' • .(' fe· CONEKT3_PCR-35_BACK_NO_ENCLOSURE i • m -- - . - • I \ I l CONEKT3_PCR-35_BACK_WITH_ENCLOSURE CONEKT3_PCR-35_BOTTOM_NO_ENCLOSURE CONEKT3_PCR-35_BOTTOM_WITH_ENCLOSURE • > m - C: ·- ------·---, -----, ----"I ... - v" - - - - • -- -- - - - .. - - CONEKT3_PCR-35_FRONT_WITH_ENCLOSURE > 0 rn .... z C (fJ ... '----· -- - •• -- ·- ..... • CONEKT3_PCR-35_SIDE1_NO_ENCLOSURE -- ---- s: - ... �": - • (/) • � 'l; ' • ' ... - - - .. I � - \ .... • - (tkdt -• • .... - CONEKT3_PCR-35_WITH_ENCLOSURE � .... ... ... ... � � ' -: . .. "II t , • ��- .. - - • ' ... • • .. --- '� 1 , - - , . )> 0 m - z __ _, C Cl) )> • • • ·--· - - -. CONEKT3_PCR-35_SIDEϮ_NO_ENCLOSURE CONEKT3_PCR-35_SIDE2_WITH_ENCLOSURE CONEKT3_PCR-35_TOP_NO_ENCLOSURE CONEKT3_PCR-35_TOP_WITH_ENCLOSURE

External Photos

• ... .. • .. f rrZ s: )> CJ m z---- c: (J) )> � t CONEKT3_PCR-620_BACK_WITH_ENCLOSURE CONEKT3_PCR-620_BOTTOM_WITH_ENCLOSURE • - -- __ ,,, __ _ .,,:._ - '--· - .'_.{, J::,,, -- 1 � -� - -- - ---�- --- -- · · - - - -- 1 ----- ---- ... --. -- -- - --� CONEKT3_PCR-620_BOTTOM_WITH_ENCLOSURE J • � - • - ��.--• -- -·- ---· ... (0 l"'n - - -· u, \(, -- · -... r -- -·- -- ...... CONEKT3_PCR-620_SIDE1_WITH_ENCLOSURE ' • " � -- - ·�·- -----·- -- C: --- (J) -- .l> ....._ ... __ _ L.,,_, �- - - - 1 , ---- -- ·- -·- �-- --- ' ' CONEKT3_PCR-620_SIDE2_WITH_ENCLOSURE CONEKT3_PCR-620_WITH_ENCLOSURE

External Photos

�-'Farpointe Data· Readers • Credentials PCR-640 Rev 1 05565-333 1111111111111111111111111 ll I 111 Ill m oo,,,cc eornpl,C$ W'lh !',vi 15 ol the FCC nAcs Opcrnl,oo : s,qccl lo Ille 1°'°"'""9 IWO c<>OOIIOOS (1)Thls 00,,,CC m:r, ol C;l<ISC h:llml\j inlcrle<C<ICC, /vld (2) 11-.s 00\'ICC roost cccpt M'f inlcrfe<C<ICC lh:11 m:r, � �cd Cf)Cf:!IIOO FCC ID: T81-CONEKT3 � IC: 6504A-CONEKT3 � 20210002 11111111111111 II I 11111 CE Input: 12 VOC, 40-180mA MADE JN USA l 1 l \ \ I ' CONEKT3_PCR-640_BACK_WITH_ENCLOSURE CONEKT3_PCR-640_BOTTOM_WITH_ENCLOSURE I I I 1 MADE IN USA L i .� ---- � __ t.. rw..z::�.__.,,_,, ____ �,·"-----•· �o ·- -� - - CONEKT3_PCR-640_FRONT_WITH_ENCLOSURE • - ' ' ' I I J l ' l J I I i I I t ' ' ' • I ' t • l I I I I f I I I I I I I I -. •) I t ') • • • • I ' • ;) • • I - .J CONEKT3_PCR-640_SIDE1_WITH_ENCLOSURE - - -,., - - - - F ' CONEKT3_PCR-640_SIDE2_WITH_ENCLOSURE CONEKT3_PCR-640_TOP_WITH_ENCLOSURE

ID Label/Location Info

Serial Number Label Specification Label P/N: 05562-333SL Date: 29MAY2020 Product P/N: 05562-333 Rev.1 Label Stock: Label 1.5" x 1.0" - REF: Quote Number Q261583 Genuine Zebra-Z-Ultimate 4000T White Polyester Label, 3" core, 5240 labels per roll. Dimensions: 1.5" wide x 1" long Ribbon - Part Number: 1150-00215 Zebra 5095 Performance Resin Ribbon Case, 1.57" x 1476 Ft. Usage: 3:1 Labels to Ribbon Serial Number Label Specification Label P/N: 05564-333SL Date: 29MAY2020 Product P/N: 05564-333 Rev.1 Label Stock: Label 1.5" x 1.0" - REF: Quote Number Q261583 Genuine Zebra-Z-Ultimate 4000T White Polyester Label, 3" core, 5240 labels per roll. Dimensions: 1.5" wide x 1" long Ribbon - Part Number: 1150-00215 Zebra 5095 Performance Resin Ribbon Case, 1.57" x 1476 Ft. Usage: 3:1 Labels to Ribbon Serial Number Label Specification Label P/N: 05565-333SL Date: 29MAY2020 Product P/N: 05565-333 Rev.1 Label Stock: Label 1.5" x 1.0" - REF: Quote Number Q261583 Genuine Zebra-Z-Ultimate 4000T White Polyester Label, 3" core, 5240 labels per roll. Dimensions: 1.5" wide x 1" long Ribbon - Part Number: 1150-00215 Zebra 5095 Performance Resin Ribbon Case, 1.57" x 1476 Ft. Usage: 3:1 Labels to Ribbon

Test Report

EMC Farpointe Data, Inc. on CONEKT® Reader File: 104274802MPK-005 Page 1 of 30 TEST REPORT Report Number: 104274802MPK-005 Project Number: G104274802 May 18, 2020 Testing performed on the CONEKT ® Reader Model Number: PCR-35 FCC ID: T8I-CONEKT3 IC: 6504A-CONEKT3 to FCC Part 15 Subpart C (15.209) FCC Part 15, Subpart B Industry Canada RSS-210 Issue 10 Industry Canada ICES-003 For Farpointe Data, Inc. Test Performed by: Test Authorized by: Intertek 1365 Adams Court Menlo Park, CA 94025 USA Farpointe Data, Inc. 2195 Zanker Road San Jose, CA 95131 USA Prepared by: Date: May 18, 2020 Aaron Chang Reviewed by: Date: May 18, 2020 Krishna Vemuri This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report must not be used to claim product endorsement by A2LA, NIST nor any other agency of the U.S. Government. EMC Farpointe Data, Inc. on CONEKT® Reader File: 104274802MPK-005 Page 2 of 30 Report No. 104274802MPK-005 Equipment Under Test: CONEKT® Readers Model Number: PCR-35 Serial Number: SN1 Applicant: Farpointe Data, Inc. Contact: Kirk Bierach Address: 2195 Zanker Road San Jose, CA 95131 Country USA Email [email protected] Applicable Regulation: FCC Part 15 Subpart C (15.209) FCC Part 15, Subpart B Industry Canada RSS-210 Issue 10 Industry Canada ICES-003 Issue 6 Test Site Location: ITS – Site 1 1365 Adams Drive Menlo Park, CA 94025 Date of Test: March 15 – April 1, 2020 We attest to the accuracy of this report: Aaron Chang Project Engineer Krishna K Vemuri EMC Manager EMC Farpointe Data, Inc. on CONEKT® Reader File: 104274802MPK-005 Page 3 of 30 TABLE OF CONTENTS 1.0 Summary of Tests .......................................................................................................................... 4 2.0 General Description ....................................................................................................................... 5 2.1 Product Description ............................................................................................................ 5 2.2 Related Submittal(s) Grants ................................................................................................ 6 2.3 Test Methodology ............................................................................................................... 6 2.4 Test Facility ........................................................................................................................ 6 2.5 Measurement Uncertainty ................................................................................................... 6 3.0 System Test Configuration ............................................................................................................ 7 3.1 EUT Photo .......................................................................................................................... 7 3.2 Block Diagram of Test Setup .............................................................................................. 8 3.3 Justification ......................................................................................................................... 9 3.4 Software Exercise Program................................................................................................. 9 3.5 Mode of Operation during test ............................................................................................ 9 3.6 Modifications required for Compliance .............................................................................. 9 3.7 Additions, deviations and exclusions from standards ......................................................... 9 4.0 Measurement Results................................................................................................................... 10 4. 1 Field Strength of Fundamental and Radiated Emissions Outside the band ...................... 10 4.1.1 Requirements ....................................................................................................... 10 4.1.2 Procedure ............................................................................................................. 11 4.1.3 Test Result ........................................................................................................... 12 4.1.5 Test Configuration Photographs .......................................................................... 15 4.2 Occupied Bandwidth ......................................................................................................... 18 4.2.1 Requirements ....................................................................................................... 18 4.2.2 Procedure ............................................................................................................. 18 4.2.3 Test Results .......................................................................................................... 19 4.3 AC Line Conducted Emission .......................................................................................... 20 4.3.1 Requirement ......................................................................................................... 20 4.3.2 Procedure ........................…

Text truncated - open the document above for the full version.

Test Report

EMC Farpointe Data, Inc. on CONEKT® Reader File: 104274802MPK-006 Page 1 of 30 TEST REPORT Report Number: 104274802MPK-006 Project Number: G104274802 May 18, 2020 Testing performed on the CONEKT ® Reader Model Number: PCR-620 FCC ID: T8I-CONEKT3 IC: 6504A-CONEKT3 to FCC Part 15 Subpart C (15.209) FCC Part 15, Subpart B Industry Canada RSS-210 Issue 10 Industry Canada ICES-003 For Farpointe Data, Inc. Test Performed by: Test Authorized by: Intertek 1365 Adams Court Menlo Park, CA 94025 USA Farpointe Data, Inc. 2195 Zanker Road San Jose, CA 95131 USA Prepared by: Date: May 18, 2020 Aaron Chang Reviewed by: Date: May 18, 2020 Krishna Vemuri This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report must not be used to claim product endorsement by A2LA, NIST nor any other agency of the U.S. Government. EMC Farpointe Data, Inc. on CONEKT® Reader File: 104274802MPK-006 Page 2 of 30 Report No. 104274802MPK-006 Equipment Under Test: CONEKT® Readers Model Number: PCR-620 Serial Number: SN1 Applicant: Farpoint e Data, Inc. Contact: Kirk Bierach Address: 2195 Zanker Road San Jose, CA 95131 Country USA Email [email protected] Applicable Regulation: FCC Part 15 Subpart C (15.209) FCC Part 15, Subpart B Industry Canada RSS-210 Issue 10 Industry Canada ICES-003 Issue 6 Test Site Location: ITS – Site 1 1365 Adams Drive Menlo Park, CA 94025 Date of Test: March 15 – April 1, 2020 We attest to the accuracy of this report: Aaron Chang Project Engineer Krishna K Vemuri EMC Manager EMC Farpointe Data, Inc. on CONEKT® Reader File: 104274802MPK-006 Page 3 of 30 TABLE OF CONTENTS 1.0 Summary of Tests .......................................................................................................................... 4 2.0 General Description ....................................................................................................................... 5 2.1 Product Description ............................................................................................................ 5 2.2 Related Submittal(s) Grants ................................................................................................ 6 2.3 Test Methodology ............................................................................................................... 6 2.4 Test Facility ........................................................................................................................ 6 2.5 Measurement Uncertainty ................................................................................................... 6 3.0 System Test Configuration ............................................................................................................ 7 3.1 EUT Photo .......................................................................................................................... 7 3.2 Block Diagram of Test Setup .............................................................................................. 8 3.3 Justification ......................................................................................................................... 9 3.4 Software Exercise Program................................................................................................. 9 3.5 Mode of Operation during test ............................................................................................ 9 3.6 Modifications required for Compliance .............................................................................. 9 3.7 Additions, deviations and exclusions from standards ......................................................... 9 4.0 Measurement Results................................................................................................................... 10 4. 1 Field Strength of Fundamental and Radiated Emissions Outside the band ...................... 10 4.1.1 Requirements ....................................................................................................... 10 4.1.2 Procedure ............................................................................................................. 11 4.1.3 Test Result ........................................................................................................... 12 4.1.5 Test Configuration Photographs .......................................................................... 15 4.2 Occupied Bandwidth ......................................................................................................... 18 4.2.1 Requirements ....................................................................................................... 18 4.2.2 Procedure ............................................................................................................. 18 4.2.3 Test Results .......................................................................................................... 19 4.3 AC Line Conducted Emission .......................................................................................... 20 4.3.1 Requirement ......................................................................................................... 20 4.3.2 Procedure .....................…

Text truncated - open the document above for the full version.

Test Report

EMC Farpointe Data, Inc. on CONEKT® Reader File: 104274802MPK-006 Page 1 of 30 TEST REPORT Report Number: 104274802MPK-007 Project Number: G104274802 May 18, 2020 Testing performed on the CONEKT ® Reader Model Number: PCR-640 FCC ID: T8I-CONEKT3 IC: 6504A-CONEKT3 to FCC Part 15 Subpart C (15.209) FCC Part 15, Subpart B Industry Canada RSS-210 Issue 10 Industry Canada ICES-003 For Farpointe Data, Inc. Test Performed by: Test Authorized by: Intertek 1365 Adams Court Menlo Park, CA 94025 USA Farpointe Data, Inc. 2195 Zanker Road San Jose, CA 95131 USA Prepared by: Date: May 18, 2020 Aaron Chang Reviewed by: Date: May 18, 2020 Krishna Vemuri This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report must not be used to claim product endorsement by A2LA, NIST nor any other agency of the U.S. Government. EMC Farpointe Data, Inc. on CONEKT® Reader File: 104274802MPK-006 Page 2 of 30 Report No. 104274802MPK-007 Equipment Under Test: CONEKT® Readers Model Number: PCR-640 Serial Number: SN1 Applicant: Farpoint e Data, Inc. Contact: Kirk Bierach Address: 2195 Zanker Road San Jose, CA 95131 Country USA Email [email protected] Applicable Regulation: FCC Part 15 Subpart C (15.209) FCC Part 15, Subpart B Industry Canada RSS-210 Issue 10 Industry Canada ICES-003 Issue 6 Test Site Location: ITS – Site 1 1365 Adams Drive Menlo Park, CA 94025 Date of Test: March 15 – April 1, 2020 We attest to the accuracy of this report: Aaron Chang Project Engineer Krishna K Vemuri EMC Manager EMC Farpointe Data, Inc. on CONEKT® Reader File: 104274802MPK-006 Page 3 of 30 TABLE OF CONTENTS 1.0 Summary of Tests .......................................................................................................................... 4 2.0 General Description ....................................................................................................................... 5 2.1 Product Description ............................................................................................................ 5 2.2 Related Submittal(s) Grants ................................................................................................ 6 2.3 Test Methodology ............................................................................................................... 6 2.4 Test Facility ........................................................................................................................ 6 2.5 Measurement Uncertainty ................................................................................................... 6 3.0 System Test Configuration ............................................................................................................ 7 3.1 EUT Photo .......................................................................................................................... 7 3.2 Block Diagram of Test Setup .............................................................................................. 8 3.3 Justification ......................................................................................................................... 9 3.4 Software Exercise Program................................................................................................. 9 3.5 Mode of Operation during test ............................................................................................ 9 3.6 Modifications required for Compliance .............................................................................. 9 3.7 Additions, deviations and exclusions from standards ......................................................... 9 4.0 Measurement Results................................................................................................................... 10 4. 1 Field Strength of Fundamental and Radiated Emissions Outside the band ...................... 10 4.1.1 Requirements ....................................................................................................... 10 4.1.2 Procedure ............................................................................................................. 11 4.1.3 Test Result ........................................................................................................... 12 4.1.5 Test Configuration Photographs .......................................................................... 15 4.2 Occupied Bandwidth ......................................................................................................... 18 4.2.1 Requirements ....................................................................................................... 18 4.2.2 Procedure ............................................................................................................. 18 4.2.3 Test Results .......................................................................................................... 19 4.3 AC Line Conducted Emission .......................................................................................... 20 4.3.1 Requirement ......................................................................................................... 20 4.3.2 Procedure .....................…

Text truncated - open the document above for the full version.

Test Setup Photos

PCR-35 PCR-620 PCR-640

Contact Information

Applicant

Kirk Bierach(Director of Engineering)
[email protected]408-731-8700Fax: 408-731-8705

Technical Contact

Farpointe Data, IncKirk Bradley Bierach
[email protected]408-731-8700

2195 Zanker Road · San Jose · United States

Non-Technical Contact

Farpointe Data, Inc.Dexter Corpuz
[email protected]408-731-8700

Test Firm

IntertekTesting Services NA Inc.Charles Parker
[email protected]650-463-2900Fax: 650 463 2910

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term

Other Applications from Farpointe Data Inc.

BLE and HF Access Control Module - FCC ID T8I-CONEKT6 - Farpointe Data Inc.
T8I-CONEKT6

BLE and HF Access Control Module

Apr 02, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
NORTEK MOBILE-READY PROXIMITY READERS - FCC ID T8I-CONEKT4 - Farpointe Data Inc.
T8I-CONEKT4

NORTEK MOBILE-READY PROXIMITY READERS

Dec 28, 2020

Equipment Class

DTS - Digital Transmission System
NORTEK MOBILE-READY CONTACTLESS SMARTCARD READER - FCC ID T8I-CONEKT5 - Farpointe Data Inc.
T8I-CONEKT5

NORTEK MOBILE-READY CONTACTLESS SMARTCARD READER

Dec 28, 2020

Equipment Class

DTS - Digital Transmission System
CONEKT MOBILE-READY CONTACTLESS SMARTCARD READER - FCC ID T8I-CONEKT2 - Farpointe Data Inc.
T8I-CONEKT2

CONEKT MOBILE-READY CONTACTLESS SMARTCARD READER

Aug 06, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Security Transmitter - FCC ID T8I-RANGER2 - Farpointe Data Inc.
T8I-RANGER2

Security Transmitter

Jan 24, 2010

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter