
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Confidentiality Class External Confidentiality Label Document Type Page Ericsson Internal 1 (1) Prepared By (Subject Responsible) Approved By (Document Responsible) Checked ERAWALA Lars Wallin I Document Number Revision Date Reference Exhibit 13 - Cover letter B 2020-11-26 TA8AKRD901166 Subject: Certification for FCC ID: TA8AKRD901166 To Whom It May Concern: Ericsson AB requests a Grant of Certification (Type Acceptance) for the above-mentioned FCC Identifier. The TDD tran smitter operates in the Upper Microwave Flexible Use Service (38.4 – 40 GHz) as per 47 CFR Part 30 and is designed for use in 5G cellular systems. Details regarding supported functionality, see clause 1.1 and 1.2 in Exhibit 12 - Technical Circuit Description. Th is radio will always require a license for transmission. The Exhibit 8 - Manuals submitted with this application is generic and may cover multiple products. This application is only valid for the model specified in the Exhibit 12 – Technical Circuit Description. Ericsson AB accept by this request the agreement set out in the document “IP SPCR 125 Annex A2 Agreements on Post-market surveillance for radio equipment certified for the US market. Ericsson AB requests confidentiality under CFR 0.459 according to attached letter. We further certify that the applicant nor any party to th e application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to section 5301 of the Anti-Drug abuse Act of 1988, 21 U.S.C. Section 862. If additional information is needed, please con tact me on the below listed number. Lars Wallin Regulatory Approval Torshamnsgatan 23 SE-164 80 Stockholm, Sweden Telephone No.: +46 70 267 00 42 e-mail: [email protected] Federal Communications Commission Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Attention: Equipment Authorization Branch
1 (1) Prepared (also subject responsible if other) No. ERAWALA EXHIBIT 13 Approved Checked Date Rev Reference BNEPBAJD 2020-09-28A Federal Communications Commission Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046, USA Attention: Equipment Authorization Branch Subject: Request for Confidentiality: FCC ID: TA8AKRD901166 To whom it may concern: We, Ericsson AB, hereby r equest that the Exhibits/Items l is ted below be withheld fro m publi c i nspection in accordance to sectio ns 0.4 57 and 0.459 of the Commission’s Rules for FCC. This due to the following reasons: Ericsson Base Stations (BS) are designed strictly based on the technical specifications of the international project 3GPP (the 3rd Generation Partnership Project). The competition in this f iel d is very i ntense and a less advanced solution/design could get an unfair advantage by accessing the information as listed below from common domain. As we believe that we have implemented groundbreaking solutions and designs into our recent BS/Radio Unit (RU) / Remote Radio Unit (RRU) / Antenna Integrated Radio (AIR) / Street Macro (SM) / Radio Dot (RD) compared to the previous BS/RU/RRU/AIR/SM/RD, the listed Exhibits/Items need to be protected from disclosure to our competitors in the industry. As the FCC records have in-depth information and a very wide distribution, we believe that you can understand our concerns. We are strong in our belief that all vendors in the industry need to compete by their own merits. We regard these Exhibits/Items to be our intellectual property and therefore as confidential information. There are advanced technical and design solutions/information in the Exhibits/Items, as mentioned above, that we regard as Ericsson proprietary, with actual and potential patents pending. The information can be advantageous to our competitors as well as sources seeking ways to hack past the built in security functionality. These solutions or information thereof are not accessible even for our customers or partners unless non-disclosure agreements for particular item(s) have been signed. Confidential product information can be found in, but not necessarily limited to, internal photos of the BS RU RRU AIR SM and RD, block diagrams, schematics diagrams, and parts lists as well as certain documents, such as the user’s manuals. Those documents can only be accessible by the customers who purchase out BS/RU/RRU/SM/RD and accept the conditions and therefore are provided with unique information access tools. EXHIBIT 9 Internal Photos EXHIBIT 10 Parts List EXHIBIT 5 Schematics EXHIBIT 8 Manuals EXHIBIT 12 Technical Circuit Description .......................................................... Lars Wallin Regulatory Approval FCC Registration Number (FRN): 0013476155 Torshamnsgatan 23 SE-164 80 Stockholm Sweden Telephone No. +46 70 267 00 42 e-mail: [email protected]
Date Page Exhibit 3 External photos 2020-12-08 1( 2) FCC ID: TA8AKRD901166 AIR 1281 B260, KRD 901 166/6, R1D Front side: Rear side: Test object label: Date Page Exhibit 3 External photos 2020-12-08 2( 2) FCC ID: TA8AKRD901166 Bottom side: Top side: Right side Left side
Exhibit 1 - FCC ID label and placement Confidentiality Class External Confidentiality Label Document Type Page Ericsson Internal 1 (1) Prepared By (Subject Responsible) Approved By (Document Responsible) Checked erawala Lars Wallin I Document Number Revision Date Reference A 2020-10-07 1 FCC ID: TA8AKRD901166 The labels are plastic stickers affixed to the product(s) via permanent adhesive. They are designed to last the expected lifetime of the products in the environment in which the products are to be operated. FCC ID: TA8AKRD901166
1 (16) GFTL-20:001274 Uen, Rev PC2, 2020-12-01 © Telefonaktiebolaget LM Ericsson AB. This report shall not be reproduced except in full, without written approval of the laboratory. EMF Test Report: Ericsson AIR 1281 B260 V1.5 (FCC) Accred. no. 1761 Testing ISO/IEC 17025 Test report issued by an Accredited Testing Laboratory Document number: GFTL-20:001274 Uen Rev PC2 Date of report: 2020-12-01 (Rev PC2) Replaces GFTL-20:001274 Uen Rev B. Testing laboratory: Ericsson EMF Research Laboratory Ericsson AB SE-164 80 Stockholm Sweden Company/Client: Henrik Börjeson Ericsson AB Mobilvägen 12 22 362, Lund Sweden Tests performed by: Paramananda Joshi Dates of tests: 2020-10-09 (Rev A) 2020-11-12 (Rev B) 2020-12-01 (Rev C) Manufacturer and market name(s) of device: Ericsson AIR 1281 B260 V1.5 Testing has been performed in accordance with: FCC OET Bulletin 65 IEC 62232:2017 Test results: RF exposure compliance boundaries (exclusion zones) related to the limits in FCC 47 CFR 1.1310 to be included in the Customer Product Information (CPI) for Ericsson AIR 1281 B260 V1.5. Additional information: Signature: Test Engineer _______________________ Paramananda Joshi Senior Researcher [email protected] Tel: +46725074006 Quality Manager __________________ Christer Törnevik Senior Expert – EMF and Health [email protected] Tel: +46705863148 2 (16) GFTL-20:001274 Uen, Rev PC2, 2020-12-01 Summary of EMF Test Report 1 Equipment under test (EUT) Product name AIR 1281 B260 V1.5 Product number KRD 901 166/6 Supported bands, Tx frequency range (GHz) and standards B260 38.4 – 40 NR Duplexing technology and fraction of downlink transmission time to total time TDD (75 %) Exposure environment General public/uncontrolled, Workers/controlled Results RF exposure compliance boundaries, outside of which the exposure is below the general public (GP) and workers (W) exposure limits, are listed below. Dimensions of the box-shaped compliance boundary for general public (GP) and workers (W) exposure for AIR 1281 applicable in markets employing the FCC RF exposure limits for total EIRP 2 with tolerance and TDD downlink duty cycle included. Mode and EIRP for AIR 1281 Dimensions of the box-shaped compliance boundary (m) Distance in front of EUT Width Height Distance behind EUT Band Stan- dard Config- uration Mode EIRP IEC 62232 installation class TDD DL duty cycle Sector shapes 3 GP W GP W GP W GP W Nominal total (dBm) Tolerance (dB) B260 NR 1 37 2.4 E10 75 % H1, H5, M3, M4 0.3 0.2 0.6 0.6 0.7 0.7 0.2 0.2 41 E10 0.4 0.2 0.6 0.6 0.7 0.7 0.2 0.2 44 E100 0.5 0.3 0.6 0.6 0.7 0.7 0.2 0.2 47 E100 0.7 0.4 0.9 0.6 0.7 0.7 0.2 0.2 2 40 2.4 E10 75 % H2, M3, M3(7.5° tilt), M9, M10, M11 0.4 0.2 0.6 0.6 0.7 0.7 0.2 0.2 M9(7.5° tilt), M11(7.5° tilt) 0.3 44 E100 H2, M3, M3(7.5° tilt), M9, M10, M11 0.6 0.3 0.6 0.6 0.7 0.7 0.2 0.2 M9(7.5° tilt), M11(7.5° tilt) 0.5 47 E100 H2, M3, M3(7.5° tilt), M9, M10, M11 0.8 0.4 0.9 0.6 0.7 0.7 0.2 0.2 M9(7.5° tilt), M11(7.5° tilt) 0.7 0.3 50 E100 H2, M3, M3(7.5° tilt), M9, M10, M11 1.1 0.5 1.2 0.6 0.7 0.7 0.2 0.2 M9(7.5° tilt), M11(7.5° tilt) 1.0 For the EIRP levels specified in the table with tolerances added, and the upward rounding of compliance boundary dimensions to the nearest decimeter, the specified results are conservative. 1 This page contains a summary of the test results. The full report provides a complete description of all test details and results. 2 Effective Isotropic Radiated Power. 3 Sector shapes in this report are abbreviated according to: H1 for Hotspot1, H2 for Hotspot2, H5 for Hotspot5, M3 for Macro3, M9 for Macro9, M10 for Macro10, and M11 for Macro11. 3 (16) GFTL-20:001274 Uen, Rev PC2, 2020-12-01 1 General information The test results presented in this report define compliance boundaries for AIR 1281 B260 V1.5. Outside of these compliance boundaries, the radio frequency (RF) exposure levels are below the limits specified by the Federal Communications Commission (FCC) [1]. The tests were performed by calculations in accordance with the Ericsson RF exposure calculation procedure for base stations [2], which is in conformity with the FCC OET Bulletin 65 [3] and IEC 62232:2017 [4]. It should be noted that the test results presented in this test report are valid for the frequency range specified in Table 1, for the antenna properties specified in Table 2, and for the EIRP levels, the tolerance and TDD downlink duty cycle specified in Table 3. These data as well as the applied antenna pattern files were supplied by the client and may affect the validity of the results. Proposed EMF health and safety information for inclusion in the Customer Product Information (CPI) is provided in Appendices A, B and C. 2 Equipment under test Tables 1 and 2 below summarize the technical data for the equipment under test (EUT) and the antenna properties for the integrated antenna. Table 3 lists the nominal total EIRP levels of the radio unit and the total time-averaged EIRP including tolerance and the TDD downlink duty cycle for Configuration Mode 1 and Configuration Mode 2. In Configuration Mode 1, the phased array antenna module (PAAM) of the product is divided into two halves, each containing 2 x 24 subarrays. In this configuration, the product can generate four beams, one for each array half and polarization. In Configuration Mode 2, the full array, containing 4 x 24 subarrays, can generate two beams, one for each polarization. EMF compliance assessments were conducted for each configuration mode at four nominal total EIRP levels for each Configuration Mode, out of eleven of those provided in Table 3, specifically at 37 dBm, 40 dBm, 43 dBm and 47 dBm for Configuration Mode 1 and at 40 dBm, 43 dBm, 47 dBm and 50 dBm for Configuration Mode 2. The EUT related data in Tables 1-3 were supplied by the client. Table 1 Technical data for the EUT. Product name and product number AIR 1281 B260 V1.5 KRD 901 166/6 Supported bands, Tx frequency range (GHz), and standards B260 38.4 – 40 NR Dime…
Text truncated - open the document above for the full version.
Calibration certificates RISE equipment used for test report P107282-F30 Serial number on equipment RISE number File name/ Page number R&S FSW 43 100 560 902 073 902 073 - FSW43.pdf R&S ESU 40 100 321 901 385 901 385 - ESU26.pdf R&S ZNB 40 101 544 BX50051 BX50051 - ZNB40.pdf Bilog antenna Schaffner 6143A 23 169 504 079 2 – 9 EMCO Horn Antenna 3115 9509-4562 502 175 10 – 16 EMCO Horn Antenna 3115 00143 161 902 212 17 – 21 EMCO Horn Antenna 3116 9904-2426 503 279 22 – 28 Mixer FS-Z60 100 996 BX90566 29 – 35 Mixer FS-Z90 101 871 BX90567 36 – 42 Mixer FS-Z110 101 467 BX81425 43 – 52 Mixer FS-Z170 100974 BX81426 53-59 Mixer FS-Z220 100967 BX81427 60-66 Flann STD Gain Horn Antenna 20240-20 Manufacturer provided gain 275170 KWP02600 67 Flann STD Gain Horn Antenna 22240-20 Manufacturer provided gain 274184 KWP02601 68 Flann STD Gain Horn Antenna 24240-20 Manufacturer provided gain 141 BX92414 69 Flann STD Gain Horn Antenna 26240-20 Manufacturer provided gain 124 440 BX92415 70 Flann STD Gain Horn Antenna 27240-20 Manufacturer provided gain 281 BX92416 71
Scope of accreditation Designated body according to SS-EN ISO/IEC 17025:2018 RISE Research Institutes of Sweden ABBorĂĄsAccreditation number1002 Fordon och automatiseringA002626-054 Kanada IT- and communications testing Technical areaMaterialMethodRequirement specificationMeasure Radio frequencyRadio equipmentRSS-130 Issue 1 RSS-132 Issue 3 RSS-133 Issue 6 RSS-139 Issue 3 RSS-140 Issue 1 RSS-195 Issue 2 RSS-199 Issue 3 RSS-210 Issue 9 RSS-247 Issue 2 RSS-Gen Issue 5 USA IT- and communications testing Technical areaMaterialMethodRequirement specificationMeasure EMCRadio equipmentANSI C63.4:2014FCC CFR 47 part 11 FCC CFR 47 part 15 FCC MP-5:1986FCC CFR 47 Part 18 Radio frequencyRadio communicationTIA-102.CAAA-D Radio equipmentANSI C63.10:2013FCC CFR 47 part 15Max frequency 220 GHz Page 1 (2) Appendix 2 ReferenceDate 2020-04-30 2020/857 IT- and communications testing Technical areaMaterialMethodRequirement specificationMeasure Radio frequencyRadio equipmentANSI C63.26:2015FCC CFR 47 Part 101Max frequency 220 GHz FCC CFR 47 Part 2Max frequency 220 GHz FCC CFR 47 Part 20Max frequency 220 GHz FCC CFR 47 Part 22Max frequency 220 GHz FCC CFR 47 Part 24Max frequency 220 GHz FCC CFR 47 Part 25Max frequency 220 GHz FCC CFR 47 Part 27Max frequency 220 GHz FCC CFR 47 Part 30Max frequency 220 GHz FCC CFR 47 Part 73Max frequency 220 GHz FCC CFR 47 Part 74Max frequency 220 GHz FCC CFR 47 Part 90Max frequency 220 GHz FCC CFR 47 Part 95Max frequency 220 GHz FCC CFR 47 Part 96Max frequency 220 GHz FCC CFR 47 Part 97Max frequency 220 GHz ANSI/TIA-603-D KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02 Page 2 (2) Appendix 2 ReferenceDate 2020-04-30 2020/857
R Kalibrierlaboratorium für Geräte der Nachrichtentechnik Calibration laboratory for measuring instruments of telecommunication engineering akkreditiert durch die / accredited by the Deutsche Akkreditierungsstelle GmbH als Kalibrierlaboratorium im / as calibration laboratory in the Deutschen Kalibrierdienst DKD D-K- KalibrierscheinKalibrierzeichen 15012-01-00 Calibration CertificateCalibration Mark 2020-07 GegenstandSignal & Spectrum Analyzer Object HerstellerROHDE & SCHWARZ Manufacturer TypFSW43 Type Fabrikat/Serien-Nr.100560 Serial number AuftraggeberRISE Research Institutes of Sweden AB Customer Brinellgatan 4 SE 504 62 Borås AuftragsnummerIA 9487145 Order No. Anzahl der Seiten des Kalibrierscheins18 Number of pages of the certificate Ort und Datum der KalibrierungKöln, 2020-07-20 Place and date of calibration Dieser Kalibrierschein darf nur vollständig und unverändert weiterverbreitet werden. Auszüge oder Änderungen bedürfen der Genehmi- gung sowohl der Deutschen Akkreditierungsstelle als auch des ausstellenden Kalibrierlaboratoriums. Kalibrierscheine ohne Unterschrift haben keine Gültigkeit. This calibration certificate may not be reproduced other than in full except with the permission of both the German Accreditation Body and the issuing laboratory. Calibration certificates without signature are not valid. Datum Bearbeiter Date Head of the calibration laboratoryPerson in charge dJMfYTxSIsBYRV6xDHQ1I5/saMPD6qLY7M5U3BR12xBGjm9TU6r7EF11gwLbghhv c0QjVgBk+XjqBssGXcrdXizfxtrU0SJwYjJepbflGcmPYNdqfglD3K/Y4EHBdHe3 2020-07-20 Bernhard KistingerChristian Flügemann ROHDE & SCHWARZ GmbH & Co. KG · International Service · Graf-Zeppelin-Straße 18 · D-51147 Köln Postfach 98 02 60 · D-51130 Köln · Telefon: (02203) 49-0 · Telefax: (02203) 49-51364 · Durchwahl: 49 - 51433Vers2010-09/RSK2016-04 560982 Leiter des Kalibrierlaboratoriums Dieser Kalibrierschein dokumentiert die Rückführung auf nationale Normale zur Darstellung der Einheiten in Übereinstim- mung mit dem Internationalen Einheiten- system (SI). Die DAkkS ist Unterzeichner der multila- teralen Übereinkommen der European co- operation for Accreditation (EA) und der International Laboratory Accreditation Co- operation (ILAC) zur gegenseitigen Aner- kennung der Kalibrierscheine. Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich. This calibration certificate documents the traceability to national standards, which realize the units of measurement accor- ding to the International System of Units (SI). The DAkkS is signatory to the multilateral agreements of the European cooperation for Accreditation (EA) and of the Interna- tional Laboratory Accreditation Coopera- tion (ILAC) for the mutual recognition of calibration certificates. The user is obliged to have the object re- calibrated at appropriate intervals. ObjectSignal & Spectrum Analyzer R TypeFSW43Serial No.100560 International Service Date2020-07-20Material No.1312.8000K43 Page2 of 18Calibration Mark560982-D-K-15012-01-00-2020-07 V1-08/Temp/Eng/2016-01 Object Data Firmware version:4.60 Installed options:B24, B21, B8, B3, K14, K9, B28, B40, B80, B13, K104 Calibration Procedure Measurement Results see from page 4 on All measurement results are metrologically traced to the International System of Units (SI) by means of an unbroken chain of calibrations to relevant primary standards of the SI units of measurements. Statement of Compliance Incoming: All measured values are within the datasheet specifications. Outgoing: All measured values are within the datasheet specifications. Working Standards used ItemTypeSerial NumberCalibration Certificate NumberCal. Due Signal GeneratorSMF100A105796523139-D-K-15195-01-01-2019-092020-09 Signal GeneratorSMA100B102330799756-D-K-15195-01-01-2019-042021-04 Signal GeneratorSMF100A105285K20-068-D-K-15012-01-00-2020-032021-03 Power MeterNRX101025K19-649-D-K-15012-01-00-2019-072021-07 Power SensorNRP18A101217K20-185-D-K-15012-01-00-2020-032021-03 Power SensorNRP-Z55130785K20-182-D-K-15012-01-00-2020-032021-03 Spectrum AnalyzerFSW50103192K20-337-D-K-15012-01-00-2020-052021-05 Network AnalyzerZVA40100418K20-069-D-K-15012-01-00-2020-022021-02 Step Attenuator 139dB 6GHzRSC102402K20-340-D-K-15012-01-00-2020-052021-05 Power Splitter1870A11909K19-663-D-K-15012-01-00-2019-052021-05 Power Splitter15341319556014-D-K-15195-01-01-2020-062021-06 Frequency StandardXSRM300877/030K19-1196-D-K-15012-01-00-2019-112020-11 Remarks Firmware Update Version 4.51 => 4.60 SelfTest passed TotalCal passed The calibration was performed according to service manual 1173.9428.02-13 following the procedures as described in calibration guideline VDI/VDE/DGQ/DKD 2622 part 11 by compairing the relevant measurands of the instrument under test with the numerical values of the quantities represented by the reference standards used. ObjectSignal & Spectrum Analyzer R TypeFSW43Serial No.100560 International Service Date2020-07-20Material No.1312.8000K43 Page3 of 18Calibration Mark560982-D-K-15012-01-00-2020-07 V1-08/Temp/Eng/2016-01 Measurement Uncertainty Together with the results on the following pages the extended measurement uncertainty is stated which was calculated from the standard measurement uncertainty multiplied by the coverage factor k = 2. It was determined in accordance with EA-4/02 M: 2013. The true value is located in the corresponding interval with a probability of 95 %. Environmental Conditions Ambient temperature(23 ± 3) °CRelative humidity(45 ± 30) % Comments on the measured results The measurement results in the test report stated below have been tested for compliance with the given specifications and marked if necessary. In doing so, the associated uncertainty of measurement has been taken into acount. The following abbrevations may be used in this certificate: ¹ Measurement results that are not covered by the DAkkS accreditation. {a}No measurement uncertainty stated because the errors always add together. So it is sure tha…
Text truncated - open the document above for the full version.
R Kalibrierlaboratorium für Geräte der Nachrichtentechnik Calibration laboratory for measuring instruments of telecommunication engineering akkreditiert durch die / accredited by the Deutsche Akkreditierungsstelle GmbH als Kalibrierlaboratorium im / as calibration laboratory in the Deutschen Kalibrierdienst DKD D-K- KalibrierscheinKalibrierzeichen 15012-01-00 Calibration CertificateCalibration Mark 2020-07 GegenstandEMI Test Receiver Object HerstellerROHDE & SCHWARZ Manufacturer TypESU40 Type Fabrikat/Serien-Nr.100321 Serial number Inventarienummer: 901385 AuftraggeberRISE Research Institutes of Sweden AB Customer Brinellgatan 4 SE 504 62 Borås Auftragsnummer-- Order No. Anzahl der Seiten des Kalibrierscheins49 Number of pages of the certificate Ort und Datum der KalibrierungKöln, 2020-07-17 Place and date of calibration Dieser Kalibrierschein darf nur vollständig und unverändert weiterverbreitet werden. Auszüge oder Änderungen bedürfen der Genehmi- gung sowohl der Deutschen Akkreditierungsstelle als auch des ausstellenden Kalibrierlaboratoriums. Kalibrierscheine ohne Unterschrift haben keine Gültigkeit. This calibration certificate may not be reproduced other than in full except with the permission of both the German Accreditation Body and the issuing laboratory. Calibration certificates without signature are not valid. Datum Bearbeiter Date Deputy head of the calibration laboratoryPerson in charge cqlokWmBYzVoJVnMgLUd3ZgukwcDAGwtCIpReDoI9Db7OvIA74rHD2RdAMGClMsK HIC+HWLU0F/Y8nHmZ8XwkEehJNxmAmD/CLrrA54LtK/9Wk02S53RuU5iVVDdeX1S 2020-07-17 Ralf SchwagereitSebastian Klein ROHDE & SCHWARZ GmbH & Co. KG · International Service · Graf-Zeppelin-Straße 18 · D-51147 Köln Postfach 98 02 60 · D-51130 Köln · Telefon: (02203) 49-0 · Telefax: (02203) 49-51364 · Durchwahl: 49 - 51433Vers2010-09/RSK2016-04 560987 Stellv. Leiter des Kalibrierlaboratoriums Dieser Kalibrierschein dokumentiert die Rückführung auf nationale Normale zur Darstellung der Einheiten in Übereinstim- mung mit dem Internationalen Einheiten- system (SI). Die DAkkS ist Unterzeichner der multila- teralen Übereinkommen der European co- operation for Accreditation (EA) und der International Laboratory Accreditation Co- operation (ILAC) zur gegenseitigen Aner- kennung der Kalibrierscheine. Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich. This calibration certificate documents the traceability to national standards, which realize the units of measurement accor- ding to the International System of Units (SI). The DAkkS is signatory to the multilateral agreements of the European cooperation for Accreditation (EA) and of the Interna- tional Laboratory Accreditation Coopera- tion (ILAC) for the mutual recognition of calibration certificates. The user is obliged to have the object re- calibrated at appropriate intervals. ObjectEMI Test Receiver R TypeESU40Serial No.100321 International Service Date2020-07-17Material No.1302.6005K40 Page2 of 49Calibration Mark560987-D-K-15012-01-00-2020-07 V1-08/Temp/Eng/2016-01 Object Data Firmware version:4.73 SP5 Installed options:B2, B16, B24 Calibration Procedure Measurement Results see from page 4 on All measurement results are metrologically traced to the International System of Units (SI) by means of an unbroken chain of calibrations to relevant primary standards of the SI units of measurements. Statement of Compliance Incoming: All measured values are within the datasheet specifications. Outgoing: All measured values are within the datasheet specifications. Working Standards used ItemTypeSerial NumberCalibration Certificate NumberCal. Due Signal GeneratorSMF100A105796523139-D-K-15195-01-01-2019-092020-09 Signal GeneratorSMA100B102330799756-D-K-15195-01-01-2019-042021-04 Signal GeneratorSMF100A105285K20-068-D-K-15012-01-00-2020-032021-03 Calibration Pulse Gen. CISPR16IGUU2918100969521254-D-K-15195-01-01-2019-082020-08 Step Attenuator 139dB 6GHzRSC102402K20-340-D-K-15012-01-00-2020-052021-05 Power MeterNRX101025K19-649-D-K-15012-01-00-2019-072021-07 Network AnalyzerZVR825047/002K19-1261-D-K-15012-01-00-2019-112020-11 Network AnalyzerZVA40100418K20-069-D-K-15012-01-00-2020-022021-02 Calibration KitZV-Z270101008558336-D-K-15195-01-01-2020-072021-07 Calibration KitZV-Z229101005519433-D-K-15195-01-01-2019-082020-08 Power SensorNRP18A101217K20-185-D-K-15012-01-00-2020-032021-03 Power SensorNRP-Z55130785K20-182-D-K-15012-01-00-2020-032021-03 Power Splitter1870A11909K19-663-D-K-15012-01-00-2019-052021-05 Power Splitter15341319556014-D-K-15195-01-01-2020-062021-06 Frequency StandardXSRM300877/030K19-1196-D-K-15012-01-00-2019-112020-11 Signal GeneratorSMA100B103831882977-D-K-15195-01-02-2020-042022-04 Remarks SelfTest passed TotalCal passed Section 23,24 contains customer requested "ClickRateAnalyzer" measurements. The calibration was performed according to service manual 1302.6163.82-04 following the procedures as described in calibration guideline VDI/VDE/DGQ/DKD 2622 part 12 by compairing the relevant measurands of the instrument under test with the numerical values of the quantities represented by the reference standards used. The receiver fulfills the requirements of the international standard CISPR 16-1- 1:2010+A1:2010. ObjectEMI Test Receiver R TypeESU40Serial No.100321 International Service Date2020-07-17Material No.1302.6005K40 Page3 of 49Calibration Mark560987-D-K-15012-01-00-2020-07 V1-08/Temp/Eng/2016-01 Measurement Uncertainty Together with the results on the following pages the extended measurement uncertainty is stated which was calculated from the standard measurement uncertainty multiplied by the coverage factor k = 2. It was determined in accordance with EA-4/02 M: 2013. The true value is located in the corresponding interval with a probability of 95 %. Environmental Conditions Ambient temperature(23 ± 3) °CRelative humidity(45 ± 30) % Comments on the measured results The measurement results in the test report stated below have been te…
Text truncated - open the document above for the full version.
R Kalibrierlaboratorium für Geräte der Nachrichtentechnik Calibration laboratory for measuring instruments of telecommunication engineering akkreditiert durch die / accredited by the Deutsche Akkreditierungsstelle GmbH als Kalibrierlaboratorium im / as calibration laboratory in the Deutschen Kalibrierdienst DKD D-K- KalibrierscheinKalibrierzeichen 15012-01-00 Calibration CertificateCalibration Mark 2020-07 GegenstandVector Network Analyzer Object HerstellerROHDE & SCHWARZ Manufacturer TypZNB40-2Port Type Fabrikat/Serien-Nr.101544 Serial number Inventarienummer: BX50051 AuftraggeberRISE Research Institutes of Sweden AB Customer Brinellgatan 4 SE 504 62 Borås Auftragsnummer-- Order No. Anzahl der Seiten des Kalibrierscheins35 Number of pages of the certificate Ort und Datum der KalibrierungKöln, 2020-07-16 Place and date of calibration Dieser Kalibrierschein darf nur vollständig und unverändert weiterverbreitet werden. Auszüge oder Änderungen bedürfen der Genehmi- gung sowohl der Deutschen Akkreditierungsstelle als auch des ausstellenden Kalibrierlaboratoriums. Kalibrierscheine ohne Unterschrift haben keine Gültigkeit. This calibration certificate may not be reproduced other than in full except with the permission of both the German Accreditation Body and the issuing laboratory. Calibration certificates without signature are not valid. Datum Bearbeiter Date Deputy head of the calibration laboratoryPerson in charge cqlokWmBYzVoJVnMgLUd3Q4BNHUXfR6fPitOpLTr479mcatjpyfgHhfnG3oOWs93 c0QjVgBk+XjqBssGXcrdXoR8z0Eg/61A9XHnoSi8eohZCOHdM1p04t5Pz17s5W3H 2020-07-16 Ralf SchwagereitChristian Flügemann ROHDE & SCHWARZ GmbH & Co. KG · International Service · Graf-Zeppelin-Straße 18 · D-51147 Köln Postfach 98 02 60 · D-51130 Köln · Telefon: (02203) 49-0 · Telefax: (02203) 49-51364 · Durchwahl: 49 - 51433Vers2010-09/RSK2016-04 560984 Stellv. Leiter des Kalibrierlaboratoriums Dieser Kalibrierschein dokumentiert die Rückführung auf nationale Normale zur Darstellung der Einheiten in Übereinstim- mung mit dem Internationalen Einheiten- system (SI). Die DAkkS ist Unterzeichner der multila- teralen Übereinkommen der European co- operation for Accreditation (EA) und der International Laboratory Accreditation Co- operation (ILAC) zur gegenseitigen Aner- kennung der Kalibrierscheine. Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich. This calibration certificate documents the traceability to national standards, which realize the units of measurement accor- ding to the International System of Units (SI). The DAkkS is signatory to the multilateral agreements of the European cooperation for Accreditation (EA) and of the Interna- tional Laboratory Accreditation Coopera- tion (ILAC) for the mutual recognition of calibration certificates. The user is obliged to have the object re- calibrated at appropriate intervals. ObjectVector Network Analyzer R TypeZNB40-2PortSerial No.101544 International Service Date2020-07-16Material No.1311.6010K72 Page2 of 35Calibration Mark560984-D-K-15012-01-00-2020-07 V1-08/Temp/Eng/2016-01 Object Data Firmware version:3.11 Installed options:ZNB-K2 Calibration Procedure Measurement Results see from page 4 on All measurement results are metrologically traced to the International System of Units (SI) by means of an unbroken chain of calibrations to relevant primary standards of the SI units of measurements. Statement of Compliance Incoming: All measured values are within the datasheet specifications. Outgoing: All measured values are within the datasheet specifications. Working Standards used ItemTypeSerial NumberCalibration Certificate Nu…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 3 | 3 | 38.45 GHz - 39.95 GHz | 5.3 W | 792MW7D | 0.05 ppm |

Multi-standard remote radio
Equipment Class
PCB - PCS Licensed Transmitter
Radio Unit
Equipment Class
PCB - PCS Licensed Transmitter
Radio Unit
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Radio Unit
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Multi-standard remote radio
Equipment Class
PCB - PCS Licensed Transmitter