FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ericsson AB/
  3. TA8AKRX10101

TA8AKRX101013GPP NR Base Radio

Ericsson AB

Application Details

Equipment Class
5GB - Part 30 Fixed Transmitter
Date of Grant
Sep 16, 2020
Application Purpose
Original Equipment
Date of Application
Sep 10, 2020
Equipment Note
3GPP NR Base Radio
Frequency Range
27550.08000000 - 28299.96000000
Company
Ericsson AB
Country
Sweden

Documents & Files

Select a file to view

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Confidentiality Class External Confidentiality Label Document Type Page Ericsson Internal 1 (1) Prepared By (Subject Responsible) Approved By (Document Responsible) Checked ERAWALA Lars Wallin I Document Number Revision Date Reference Exhibit 13 - Cover letter C 2020-09-01 TA8AKRX10101 Subject: Certification for FCC ID: TA8AKRX10101 To Whom It May Concern: Ericsson AB requests a Grant of Certification (Type Acceptance) for the above-mentioned (Limited Single-Modular transmitter) FCC Identifier. Details regarding FCC § 15.212, see clause 1.12 in Exhibit 12 - Technical Circuit Description. The TDD modular transmitter operates in the Upper Microwave Flexible Use Service (27.5 – 28.35 GHz) as per 47 CFR Part 30 and is designed for use in 5G cellular systems. Details regarding supported functionality, see clause 1.1 and 1.2 in Exhibit 12 - Technical Circuit Description. This radio will always require a license for transmission. The Exhibit 8 - Manuals submitted with this application is generic and may cover multiple products. This application is only valid for the model specified in the Exhibit 12 – Technical Circuit Description. Ericsson AB accept by this request th e agreement set out in the document “IP SPCR 125 Annex A2 Agreements on Post-market surveillance for radio equipment certified for the US market. Ericsson AB requests confidentiality under CFR 0.459 according to attached letter. We further certify that the applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to section 5301 of the Anti-Drug abuse Act of 1988, 21 U.S.C. Section 862. If additional information is needed, please contact me on the below listed number. Lars Wallin Quality and Release Management – Regulatory Approval Torshamnsgatan 23 SE-164 80 Stockholm, Sweden Telephone No.: +46 70 267 00 42 e-mail: [email protected] Federal Communications Commission Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Attention: Equipment Authorization Branch

Cover Letter(s)

1 (1) Prepared (also subject responsible if other) No. ERAWALA EXHIBIT 13 Approved Checked Date Rev Reference BNEPBAJD 2020-07-10B Federal Communications Commission Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046, USA Attention: Equipment Authorization Branch Subject: Request for Confidentiality: FCC ID: TA8AKRX10101 To whom it may concern: We, Ericsson AB, hereby r equest that the Exhibits/Items l is ted below be withheld fro m publi c i nspection in accordance to sectio ns 0.4 57 and 0.459 of the Commission’s Rules for FCC. This due to the following reasons: Ericsson Base Stations (BS) are designed strictly based on the technical specifications of the international project 3GPP (the 3rd Generation Partnership Project). The competition in this f iel d is very i ntense and a less advanced solution/design could get an unfair advantage by accessing the information as listed below from common domain. As we believe that we have implemented groundbreaking solutions and designs into our recent BS/Radio Unit (RU) / Remote Radio Unit (RRU) / Antenna Integrated Radio (AIR) / Street Macro (SM) / Radio Dot (RD) compared to the previous BS/RU/RRU/AIR/SM/RD, the listed Exhibits/Items need to be protected from disclosure to our competitors in the industry. As the FCC records have in-depth information and a very wide distribution, we believe that you can understand our concerns. We are strong in our belief that all vendors in the industry need to compete by their own merits. We regard these Exhibits/Items to be our intellectual property and therefore as confidential information. There are advanced technical and design solutions/information in the Exhibits/Items, as mentioned above, that we regard as Ericsson proprietary, with actual and potential patents pending. The information can be advantageous to our competitors as well as sources seeking ways to hack past the built in security functionality. These solutions or information thereof are not accessible even for our customers or partners unless non-disclosure agreements for particular item(s) have been signed. Confidential product information can be found in, but not necessarily limited to, internal photos of the BS RU RRU AIR SM and RD, block diagrams, schematics diagrams, and parts lists as well as certain documents, such as the user’s manuals. Those documents can only be accessible by the customers who purchase out BS/RU/RRU/SM/RD and accept the conditions and therefore are provided with unique information access tools. EXHIBIT 9 Internal Photos EXHIBIT 10 Parts List EXHIBIT 5 Schematics EXHIBIT 8 Manuals EXHIBIT 12 Technical Circuit Description .......................................................... Lars Wallin Quality and Release Management – Regulatory Approval FCC Registration Number (FRN): 0013476155 Torshamnsgatan 23 SE-164 80 Stockholm Sweden Telephone No. +46 70 267 00 42 e-mail: [email protected]

External Photos

Confidentiality Class External Confidentiality Label Document Type Page Ericsson Internal 1 (1) Prepared By (Subject Responsible) Approved By (Document Responsible) Checked ERAWALA Document Number Revision Date Reference A 2020-08-26 Exhibit 3 – External Photos FCC ID: TA8AKRX10101 External photos: See photo 1-6 at page 2-3 in Exhibit 9 - Internal photos.

ID Label/Location Info

Exhibit 1 - FCC ID label and placement Confidentiality Class External Confidentiality Label Document Type Page Ericsson Internal 1 (1) Prepared By (Subject Responsible) Approved By (Document Responsible) Checked erawala Lars Wallin I Document Number Revision Date Reference A 2020-07-10 1 FCC ID: TA8AKRX10101 Module front side. Host(s) will be marked visible from outside as: The labels are plastic stickers affixed to the product(s) via permanent adhesive. They are designed to last the expected lifetime of the products in the environment in which the products are to be operated. FCC ID: TA8AKRX10101 Contains FCC ID: TA8AKRX10101

RF Exposure Info

1 (11) GFTL-20:000501 Uen, Rev B, 2020-09-11 © Telefonaktiebolaget LM Ericsson AB. This report shall not be reproduced except in full, without written approval of the laboratory. EMF Test Report: Ericsson AIR 1281 B261 (FCC) Ackred. Nr 1761 Provning ISO/IEC 17025 Rapport utfärdad av ackrediterat provningslaboratorium Test report issued by an Accredited Testing Laboratory Document number: GFTL-20:000501 Uen Rev B Date of report: 2020-09-11 (Rev B) Replaces GFTL-20:000501 Uen Rev A. Testing laboratory: Ericsson EMF Research Laboratory Ericsson AB SE-164 80 Stockholm Sweden Company/Client: Shigeru Kawabata Ericsson AB Mobilvägen 12 22 362, Lund Sweden Tests performed by: Paramananda Joshi Dates of tests: 2020-04-20 (Rev A) Manufacturer and market name(s) of device: Ericsson AIR 1281 B261 Testing has been performed in accordance with: FCC OET Bulletin 65 IEC 62232:2017 Test results: RF exposure compliance boundaries (exclusion zones) related to the limits in FCC 47 CFR 1.1310 to be included in the Customer Product Information (CPI) for Ericsson AIR 1281 B261. Additional information: Signature: Test Engineer _______________________ Paramananda Joshi Senior Researcher [email protected] Tel: +46725074006 Quality Manager __________________ Christer Törnevik Senior Expert – EMF and Health [email protected] Tel: +46705863148 2 (11) GFTL-20:000501 Uen, Rev B, 2020-09-11 Summary of EMF Test Report 1 Equipment under test (EUT) Product name AIR 1281 B261 Product number KRD 901 165/2, KRD 901 165/5 Supported bands, Tx frequency range (GHz) and standards B261 27.5 – 28.35 NR Duplexing technology and fraction of downlink transmission time to total time TDD (75 %) Exposure environment General public/uncontrolled, Workers/controlled Results RF exposure compliance boundaries, outside of which the exposure is below the general public (GP) and workers (W) exposure limits, are listed below. Dimensions of the box-shaped compliance boundary for general public (GP) and workers (W) exposure for AIR 1281 applicable in markets employing the FCC RF exposure limits for total output power with power tolerance and TDD downlink duty cycle included. Mode and output power for AIR 1281 Dimensions of the box-shaped compliance boundary (m) Distance in front of EUT Width Height Distance behind EUT Band Stan- dard Config Mode 2 Nominal total output power (W) Nominal total EIRP (dBm) IEC 62232 installation class [4] Power tolerance (dB) TDD DL duty cycle Sector shapes GP W GP W GP W GP W B261 NR 1 0.053 43 E100 1.5 75 % Hotspot1 0.4 0.2 0.7 0.7 0.7 0.7 0.2 0.2 0.132 47 E100 0.7 0.3 0.8 0.7 0.7 0.7 0.2 0.2 0.263 50 E100 0.9 0.4 1.1 0.7 0.7 0.7 0.2 0.2 0.525 53 E+ 1.3 0.6 1.6 0.7 0.7 0.7 0.2 0.2 2 0.053 46 E100 1.5 75 % Hotspot2, Macro3 0.6 0.3 0.7 0.7 0.7 0.7 0.2 0.2 0.132 50 E100 Hotspot2, Macro3 0.9 0.5 1.1 0.7 0.7 0.7 0.2 0.2 0.263 53 E+ Hotspot2, Macro3 1.3 0.6 1.5 0.7 0.7 0.7 0.2 0.2 0.525 56 E+ Hotspot2 1.8 0.8 2.2 1.0 0.8 0.7 0.2 0.2 Macro3 0.7 For the power levels specified in the table with tolerances added, and the upward rounding of compliance boundary dimensions to the nearest decimeter, the specified results are conservative. 1 This page contains a summary of the test results. The full report provides a complete description of all test details and results. 2 Configuration Mode. 3 (11) GFTL-20:000501 Uen, Rev B, 2020-09-11 1 General information The test results presented in this report define compliance boundaries for AIR 1281 B261. Outside of these compliance boundaries, the radio frequency (RF) exposure levels are below the limits specified by the Federal Communications Commission (FCC) [1]. The tests were performed by calculations in accordance with the Ericsson RF exposure calculation procedure for base stations [2], which is in conformity with the FCC OET Bulletin 65 [3] and IEC 62232:2017 [4]. It should be noted that the test results presented in this test report are valid for the frequency range specified in Table 1, for the antenna properties specified in Table 2, and for the power levels, the power tolerance and TDD downlink duty cycle specified in Table 3. These data as well as the applied antenna pattern files were supplied by the client and may affect the validity of the results. Proposed EMF health and safety information for inclusion in the Customer Product Information (CPI) is provided in Appendices A, B and C. 2 Equipment under test Tables 1 and 2 below summarize the technical data for the equipment under test (EUT) and the antenna properties for the integrated antenna. Table 3 lists the nominal total output power levels from the radio unit and the total time-averaged output power including output power tolerance and the TDD downlink duty cycle for Configuration Mode 1 and Configuration Mode 2. In Configuration Mode 1, the phased array antenna module (PAAM) of the product is divided into two halves, each containing 2 x 24 subarrays. In this configuration, the product can generate four beams, one for each array half and polarization. In Configuration Mode 2, the full array, containing 4 x 24 subarrays, can generate two beams, one for each polarization. EMF compliance assessments were conducted for each configuration mode at four nominal total output power levels, out of eleven of those provided in Table 3, specifically at 17.2 dBm, 21.2 dBm, 24.2 dBm and 27.2 dBm. The EUT related data in Tables 1-3 were supplied by the client. Table 1 Technical data for the EUT. Product name and product number AIR 1281 B261 KRD 901 165/2, KRD 901 165/5 Supported bands, Tx frequency range (GHz), and standards B261 27.5 – 28.35 NR Dimensions 3 , H x W x D (mm) 290 Ă— 200 Ă— 136 Duplexing technology and fraction of downlink transmission time to total time TDD (75 %) Exposure environment General public/uncontrolled, Workers/controlled IEC 62232 installation class [4] 4 E100 (for configurations with nominal total EIRP ≤ 50 dBm) E+ (for configurations with nominal total EIRP > 50 dBm) 3 The dimensions …

Text truncated - open the document above for the full version.

Test Report

Scope of accreditation Designated body according to SS-EN ISO/IEC 17025:2018 RISE Research Institutes of Sweden ABBorĂĄsAccreditation number1002 Fordon och automatiseringA002626-054 Kanada IT- and communications testing Technical areaMaterialMethodRequirement specificationMeasure Radio frequencyRadio equipmentRSS-130 Issue 1 RSS-132 Issue 3 RSS-133 Issue 6 RSS-139 Issue 3 RSS-140 Issue 1 RSS-195 Issue 2 RSS-199 Issue 3 RSS-210 Issue 9 RSS-247 Issue 2 RSS-Gen Issue 5 USA IT- and communications testing Technical areaMaterialMethodRequirement specificationMeasure EMCRadio equipmentANSI C63.4:2014FCC CFR 47 part 11 FCC CFR 47 part 15 FCC MP-5:1986FCC CFR 47 Part 18 Radio frequencyRadio communicationTIA-102.CAAA-D Radio equipmentANSI C63.10:2013FCC CFR 47 part 15Max frequency 220 GHz Page 1 (2) Appendix 2 ReferenceDate 2020-04-30 2020/857 IT- and communications testing Technical areaMaterialMethodRequirement specificationMeasure Radio frequencyRadio equipmentANSI C63.26:2015FCC CFR 47 Part 101Max frequency 220 GHz FCC CFR 47 Part 2Max frequency 220 GHz FCC CFR 47 Part 20Max frequency 220 GHz FCC CFR 47 Part 22Max frequency 220 GHz FCC CFR 47 Part 24Max frequency 220 GHz FCC CFR 47 Part 25Max frequency 220 GHz FCC CFR 47 Part 27Max frequency 220 GHz FCC CFR 47 Part 30Max frequency 220 GHz FCC CFR 47 Part 73Max frequency 220 GHz FCC CFR 47 Part 74Max frequency 220 GHz FCC CFR 47 Part 90Max frequency 220 GHz FCC CFR 47 Part 95Max frequency 220 GHz FCC CFR 47 Part 96Max frequency 220 GHz FCC CFR 47 Part 97Max frequency 220 GHz ANSI/TIA-603-D KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02 Page 2 (2) Appendix 2 ReferenceDate 2020-04-30 2020/857

Test Report

R Kalibrierlaboratorium für Geräte der Nachrichtentechnik Calibration laboratory for measuring instruments of telecommunication engineering akkreditiert durch die / accredited by the Deutsche Akkreditierungsstelle GmbH als Kalibrierlaboratorium im / as calibration laboratory in the Deutschen Kalibrierdienst DKD D-K- KalibrierscheinKalibrierzeichen 15012-01-00 Calibration CertificateCalibration Mark 2020-07 GegenstandSignal & Spectrum Analyzer Object HerstellerROHDE & SCHWARZ Manufacturer TypFSW43 Type Fabrikat/Serien-Nr.100560 Serial number AuftraggeberRISE Research Institutes of Sweden AB Customer Brinellgatan 4 SE 504 62 Borås AuftragsnummerIA 9487145 Order No. Anzahl der Seiten des Kalibrierscheins18 Number of pages of the certificate Ort und Datum der KalibrierungKöln, 2020-07-20 Place and date of calibration Dieser Kalibrierschein darf nur vollständig und unverändert weiterverbreitet werden. Auszüge oder Änderungen bedürfen der Genehmi- gung sowohl der Deutschen Akkreditierungsstelle als auch des ausstellenden Kalibrierlaboratoriums. Kalibrierscheine ohne Unterschrift haben keine Gültigkeit. This calibration certificate may not be reproduced other than in full except with the permission of both the German Accreditation Body and the issuing laboratory. Calibration certificates without signature are not valid. Datum Bearbeiter Date Head of the calibration laboratoryPerson in charge dJMfYTxSIsBYRV6xDHQ1I5/saMPD6qLY7M5U3BR12xBGjm9TU6r7EF11gwLbghhv c0QjVgBk+XjqBssGXcrdXizfxtrU0SJwYjJepbflGcmPYNdqfglD3K/Y4EHBdHe3 2020-07-20 Bernhard KistingerChristian Flügemann ROHDE & SCHWARZ GmbH & Co. KG · International Service · Graf-Zeppelin-Straße 18 · D-51147 Köln Postfach 98 02 60 · D-51130 Köln · Telefon: (02203) 49-0 · Telefax: (02203) 49-51364 · Durchwahl: 49 - 51433Vers2010-09/RSK2016-04 560982 Leiter des Kalibrierlaboratoriums Dieser Kalibrierschein dokumentiert die Rückführung auf nationale Normale zur Darstellung der Einheiten in Übereinstim- mung mit dem Internationalen Einheiten- system (SI). Die DAkkS ist Unterzeichner der multila- teralen Übereinkommen der European co- operation for Accreditation (EA) und der International Laboratory Accreditation Co- operation (ILAC) zur gegenseitigen Aner- kennung der Kalibrierscheine. Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich. This calibration certificate documents the traceability to national standards, which realize the units of measurement accor- ding to the International System of Units (SI). The DAkkS is signatory to the multilateral agreements of the European cooperation for Accreditation (EA) and of the Interna- tional Laboratory Accreditation Coopera- tion (ILAC) for the mutual recognition of calibration certificates. The user is obliged to have the object re- calibrated at appropriate intervals. ObjectSignal & Spectrum Analyzer R TypeFSW43Serial No.100560 International Service Date2020-07-20Material No.1312.8000K43 Page2 of 18Calibration Mark560982-D-K-15012-01-00-2020-07 V1-08/Temp/Eng/2016-01 Object Data Firmware version:4.60 Installed options:B24, B21, B8, B3, K14, K9, B28, B40, B80, B13, K104 Calibration Procedure Measurement Results see from page 4 on All measurement results are metrologically traced to the International System of Units (SI) by means of an unbroken chain of calibrations to relevant primary standards of the SI units of measurements. Statement of Compliance Incoming: All measured values are within the datasheet specifications. Outgoing: All measured values are within the datasheet specifications. Working Standards used ItemTypeSerial NumberCalibration Certificate NumberCal. Due Signal GeneratorSMF100A105796523139-D-K-15195-01-01-2019-092020-09 Signal GeneratorSMA100B102330799756-D-K-15195-01-01-2019-042021-04 Signal GeneratorSMF100A105285K20-068-D-K-15012-01-00-2020-032021-03 Power MeterNRX101025K19-649-D-K-15012-01-00-2019-072021-07 Power SensorNRP18A101217K20-185-D-K-15012-01-00-2020-032021-03 Power SensorNRP-Z55130785K20-182-D-K-15012-01-00-2020-032021-03 Spectrum AnalyzerFSW50103192K20-337-D-K-15012-01-00-2020-052021-05 Network AnalyzerZVA40100418K20-069-D-K-15012-01-00-2020-022021-02 Step Attenuator 139dB 6GHzRSC102402K20-340-D-K-15012-01-00-2020-052021-05 Power Splitter1870A11909K19-663-D-K-15012-01-00-2019-052021-05 Power Splitter15341319556014-D-K-15195-01-01-2020-062021-06 Frequency StandardXSRM300877/030K19-1196-D-K-15012-01-00-2019-112020-11 Remarks Firmware Update Version 4.51 => 4.60 SelfTest passed TotalCal passed The calibration was performed according to service manual 1173.9428.02-13 following the procedures as described in calibration guideline VDI/VDE/DGQ/DKD 2622 part 11 by compairing the relevant measurands of the instrument under test with the numerical values of the quantities represented by the reference standards used. ObjectSignal & Spectrum Analyzer R TypeFSW43Serial No.100560 International Service Date2020-07-20Material No.1312.8000K43 Page3 of 18Calibration Mark560982-D-K-15012-01-00-2020-07 V1-08/Temp/Eng/2016-01 Measurement Uncertainty Together with the results on the following pages the extended measurement uncertainty is stated which was calculated from the standard measurement uncertainty multiplied by the coverage factor k = 2. It was determined in accordance with EA-4/02 M: 2013. The true value is located in the corresponding interval with a probability of 95 %. Environmental Conditions Ambient temperature(23 ± 3) °CRelative humidity(45 ± 30) % Comments on the measured results The measurement results in the test report stated below have been tested for compliance with the given specifications and marked if necessary. In doing so, the associated uncertainty of measurement has been taken into acount. The following abbrevations may be used in this certificate: ¹ Measurement results that are not covered by the DAkkS accreditation. {a}No measurement uncertainty stated because the errors always add together. So it is sure tha…

Text truncated - open the document above for the full version.

Test Report

R Kalibrierlaboratorium für Geräte der Nachrichtentechnik Calibration laboratory for measuring instruments of telecommunication engineering akkreditiert durch die / accredited by the Deutsche Akkreditierungsstelle GmbH als Kalibrierlaboratorium im / as calibration laboratory in the Deutschen Kalibrierdienst DKD D-K- KalibrierscheinKalibrierzeichen 15012-01-00 Calibration CertificateCalibration Mark 2020-07 GegenstandEMI Test Receiver Object HerstellerROHDE & SCHWARZ Manufacturer TypESU40 Type Fabrikat/Serien-Nr.100321 Serial number Inventarienummer: 901385 AuftraggeberRISE Research Institutes of Sweden AB Customer Brinellgatan 4 SE 504 62 Borås Auftragsnummer-- Order No. Anzahl der Seiten des Kalibrierscheins49 Number of pages of the certificate Ort und Datum der KalibrierungKöln, 2020-07-17 Place and date of calibration Dieser Kalibrierschein darf nur vollständig und unverändert weiterverbreitet werden. Auszüge oder Änderungen bedürfen der Genehmi- gung sowohl der Deutschen Akkreditierungsstelle als auch des ausstellenden Kalibrierlaboratoriums. Kalibrierscheine ohne Unterschrift haben keine Gültigkeit. This calibration certificate may not be reproduced other than in full except with the permission of both the German Accreditation Body and the issuing laboratory. Calibration certificates without signature are not valid. Datum Bearbeiter Date Deputy head of the calibration laboratoryPerson in charge cqlokWmBYzVoJVnMgLUd3ZgukwcDAGwtCIpReDoI9Db7OvIA74rHD2RdAMGClMsK HIC+HWLU0F/Y8nHmZ8XwkEehJNxmAmD/CLrrA54LtK/9Wk02S53RuU5iVVDdeX1S 2020-07-17 Ralf SchwagereitSebastian Klein ROHDE & SCHWARZ GmbH & Co. KG · International Service · Graf-Zeppelin-Straße 18 · D-51147 Köln Postfach 98 02 60 · D-51130 Köln · Telefon: (02203) 49-0 · Telefax: (02203) 49-51364 · Durchwahl: 49 - 51433Vers2010-09/RSK2016-04 560987 Stellv. Leiter des Kalibrierlaboratoriums Dieser Kalibrierschein dokumentiert die Rückführung auf nationale Normale zur Darstellung der Einheiten in Übereinstim- mung mit dem Internationalen Einheiten- system (SI). Die DAkkS ist Unterzeichner der multila- teralen Übereinkommen der European co- operation for Accreditation (EA) und der International Laboratory Accreditation Co- operation (ILAC) zur gegenseitigen Aner- kennung der Kalibrierscheine. Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich. This calibration certificate documents the traceability to national standards, which realize the units of measurement accor- ding to the International System of Units (SI). The DAkkS is signatory to the multilateral agreements of the European cooperation for Accreditation (EA) and of the Interna- tional Laboratory Accreditation Coopera- tion (ILAC) for the mutual recognition of calibration certificates. The user is obliged to have the object re- calibrated at appropriate intervals. ObjectEMI Test Receiver R TypeESU40Serial No.100321 International Service Date2020-07-17Material No.1302.6005K40 Page2 of 49Calibration Mark560987-D-K-15012-01-00-2020-07 V1-08/Temp/Eng/2016-01 Object Data Firmware version:4.73 SP5 Installed options:B2, B16, B24 Calibration Procedure Measurement Results see from page 4 on All measurement results are metrologically traced to the International System of Units (SI) by means of an unbroken chain of calibrations to relevant primary standards of the SI units of measurements. Statement of Compliance Incoming: All measured values are within the datasheet specifications. Outgoing: All measured values are within the datasheet specifications. Working Standards used ItemTypeSerial NumberCalibration Certificate NumberCal. Due Signal GeneratorSMF100A105796523139-D-K-15195-01-01-2019-092020-09 Signal GeneratorSMA100B102330799756-D-K-15195-01-01-2019-042021-04 Signal GeneratorSMF100A105285K20-068-D-K-15012-01-00-2020-032021-03 Calibration Pulse Gen. CISPR16IGUU2918100969521254-D-K-15195-01-01-2019-082020-08 Step Attenuator 139dB 6GHzRSC102402K20-340-D-K-15012-01-00-2020-052021-05 Power MeterNRX101025K19-649-D-K-15012-01-00-2019-072021-07 Network AnalyzerZVR825047/002K19-1261-D-K-15012-01-00-2019-112020-11 Network AnalyzerZVA40100418K20-069-D-K-15012-01-00-2020-022021-02 Calibration KitZV-Z270101008558336-D-K-15195-01-01-2020-072021-07 Calibration KitZV-Z229101005519433-D-K-15195-01-01-2019-082020-08 Power SensorNRP18A101217K20-185-D-K-15012-01-00-2020-032021-03 Power SensorNRP-Z55130785K20-182-D-K-15012-01-00-2020-032021-03 Power Splitter1870A11909K19-663-D-K-15012-01-00-2019-052021-05 Power Splitter15341319556014-D-K-15195-01-01-2020-062021-06 Frequency StandardXSRM300877/030K19-1196-D-K-15012-01-00-2019-112020-11 Signal GeneratorSMA100B103831882977-D-K-15195-01-02-2020-042022-04 Remarks SelfTest passed TotalCal passed Section 23,24 contains customer requested "ClickRateAnalyzer" measurements. The calibration was performed according to service manual 1302.6163.82-04 following the procedures as described in calibration guideline VDI/VDE/DGQ/DKD 2622 part 12 by compairing the relevant measurands of the instrument under test with the numerical values of the quantities represented by the reference standards used. The receiver fulfills the requirements of the international standard CISPR 16-1- 1:2010+A1:2010. ObjectEMI Test Receiver R TypeESU40Serial No.100321 International Service Date2020-07-17Material No.1302.6005K40 Page3 of 49Calibration Mark560987-D-K-15012-01-00-2020-07 V1-08/Temp/Eng/2016-01 Measurement Uncertainty Together with the results on the following pages the extended measurement uncertainty is stated which was calculated from the standard measurement uncertainty multiplied by the coverage factor k = 2. It was determined in accordance with EA-4/02 M: 2013. The true value is located in the corresponding interval with a probability of 95 %. Environmental Conditions Ambient temperature(23 ± 3) °CRelative humidity(45 ± 30) % Comments on the measured results The measurement results in the test report stated below have been te…

Text truncated - open the document above for the full version.

Test Report

R Kalibrierlaboratorium für Geräte der Nachrichtentechnik Calibration laboratory for measuring instruments of telecommunication engineering akkreditiert durch die / accredited by the Deutsche Akkreditierungsstelle GmbH als Kalibrierlaboratorium im / as calibration laboratory in the Deutschen Kalibrierdienst DKD D-K- KalibrierscheinKalibrierzeichen 15012-01-00 Calibration CertificateCalibration Mark 2020-07 GegenstandVector Network Analyzer Object HerstellerROHDE & SCHWARZ Manufacturer TypZNB40-2Port Type Fabrikat/Serien-Nr.101544 Serial number Inventarienummer: BX50051 AuftraggeberRISE Research Institutes of Sweden AB Customer Brinellgatan 4 SE 504 62 Borås Auftragsnummer-- Order No. Anzahl der Seiten des Kalibrierscheins35 Number of pages of the certificate Ort und Datum der KalibrierungKöln, 2020-07-16 Place and date of calibration Dieser Kalibrierschein darf nur vollständig und unverändert weiterverbreitet werden. Auszüge oder Änderungen bedürfen der Genehmi- gung sowohl der Deutschen Akkreditierungsstelle als auch des ausstellenden Kalibrierlaboratoriums. Kalibrierscheine ohne Unterschrift haben keine Gültigkeit. This calibration certificate may not be reproduced other than in full except with the permission of both the German Accreditation Body and the issuing laboratory. Calibration certificates without signature are not valid. Datum Bearbeiter Date Deputy head of the calibration laboratoryPerson in charge cqlokWmBYzVoJVnMgLUd3Q4BNHUXfR6fPitOpLTr479mcatjpyfgHhfnG3oOWs93 c0QjVgBk+XjqBssGXcrdXoR8z0Eg/61A9XHnoSi8eohZCOHdM1p04t5Pz17s5W3H 2020-07-16 Ralf SchwagereitChristian Flügemann ROHDE & SCHWARZ GmbH & Co. KG · International Service · Graf-Zeppelin-Straße 18 · D-51147 Köln Postfach 98 02 60 · D-51130 Köln · Telefon: (02203) 49-0 · Telefax: (02203) 49-51364 · Durchwahl: 49 - 51433Vers2010-09/RSK2016-04 560984 Stellv. Leiter des Kalibrierlaboratoriums Dieser Kalibrierschein dokumentiert die Rückführung auf nationale Normale zur Darstellung der Einheiten in Übereinstim- mung mit dem Internationalen Einheiten- system (SI). Die DAkkS ist Unterzeichner der multila- teralen Übereinkommen der European co- operation for Accreditation (EA) und der International Laboratory Accreditation Co- operation (ILAC) zur gegenseitigen Aner- kennung der Kalibrierscheine. Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich. This calibration certificate documents the traceability to national standards, which realize the units of measurement accor- ding to the International System of Units (SI). The DAkkS is signatory to the multilateral agreements of the European cooperation for Accreditation (EA) and of the Interna- tional Laboratory Accreditation Coopera- tion (ILAC) for the mutual recognition of calibration certificates. The user is obliged to have the object re- calibrated at appropriate intervals. ObjectVector Network Analyzer R TypeZNB40-2PortSerial No.101544 International Service Date2020-07-16Material No.1311.6010K72 Page2 of 35Calibration Mark560984-D-K-15012-01-00-2020-07 V1-08/Temp/Eng/2016-01 Object Data Firmware version:3.11 Installed options:ZNB-K2 Calibration Procedure Measurement Results see from page 4 on All measurement results are metrologically traced to the International System of Units (SI) by means of an unbroken chain of calibrations to relevant primary standards of the SI units of measurements. Statement of Compliance Incoming: All measured values are within the datasheet specifications. Outgoing: All measured values are within the datasheet specifications. Working Standards used ItemTypeSerial NumberCalibration Certificate NumberCal. Due Signal GeneratorSMF100A105796523139-D-K-15195-01-01-2019-092020-09 Calibration KitZV-Z229101005519433-D-K-15195-01-01-2019-082020-08 Power MeterNRX101025K19-649-D-K-15012-01-00-2019-072021-07 Power SensorNRP-Z55130785K20-182-D-K-15012-01-00-2020-032021-03 Spectrum AnalyzerFSW50103192K20-337-D-K-15012-01-00-2020-052021-05 Source Meter24000881497K20-072-D-K-15012-01-00-2020-022021-02 MultimeterUDS5879948/039K20-082-D-K-15012-01-00-2020-022021-02 Frequency StandardXSRM300877/030K19-1196-D-K-15012-01-00-2019-112020-11 Power Splitter15341319556014-D-K-15195-01-01-2020-062021-06 Remarks Firmware Update Version 2.94 => 3.11 SelfTest passed The calibration was pe…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Peter Moberg(Head of PEU Radio)
[email protected]+46 10 719 00 00Fax: +46 10 716 00 28

Technical Contact

Ericsson ABLars Wallin
[email protected]+46702670042

Torshamnsgatan 23 · Stockholm · Sweden

Test Firm

RISE Research Institutes of Sweden ABDaniel Lundgren
[email protected]+46 10 516 5836

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
3327.55 GHz - 28.30 GHz17 W793MW7D0.05 ppm
Modular Type
Limited Single Modular Approval
Confidentiality
Long Term
Grant Notes
The power output listed is Maximum EIRP/ 100 MHz. This transmitter must only be integrated in the grantees own end products and must only be operated in the grantees RBS systems. Compliance of end product configurations with this transmitter is the responsibility of the Grantee. End products must be fixed-mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3).

Other Applications from Ericsson AB

Multi-standard remote radio - FCC ID TA8BKRD901316 - Ericsson AB
TA8BKRD901316

Multi-standard remote radio

Sep 02, 2026

Equipment Class

PCB - PCS Licensed Transmitter
Radio Unit - FCC ID TA8BKRY901523 - Ericsson AB
TA8BKRY901523

Radio Unit

Jul 23, 2026

Equipment Class

PCB - PCS Licensed Transmitter
Radio Unit - FCC ID TA8BKRY901515 - Ericsson AB
TA8BKRY901515

Radio Unit

Jul 23, 2026

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Radio Unit - FCC ID TA8BKRY901551 - Ericsson AB
TA8BKRY901551

Radio Unit

Jul 06, 2026

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Multi-standard remote radio - FCC ID TA8AKRD901316 - Ericsson AB
TA8AKRD901316

Multi-standard remote radio

Jun 29, 2026

Equipment Class

PCB - PCS Licensed Transmitter