FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ericsson AB/
  3. TA8AKRX10102

TA8AKRX101023GPP NR Base Radio

Ericsson AB

Application Details

Equipment Class
5GB - Part 30 Fixed Transmitter
Date of Grant
Jun 05, 2020
Application Purpose
Original Equipment
Date of Application
May 31, 2020
Equipment Note
3GPP NR Base Radio
Frequency Range
37050.00000000 - 39949.92000000
Company
Ericsson AB
Country
Sweden

Documents & Files

Select a file to view

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

1 (1) Prepared (also subject responsible if other) No. ERAWALA EXHIBIT 13 Approved Checked Date Rev Reference BNEPBAJD 2020-05-07A Federal Communications Commission Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046, USA Attention: Equipment Authorization Branch Subject: Request for Confidentiality: FCC ID: TA8AKRX10102 To whom it may concern: We, Ericsson AB, hereby r equest that the Exhibits/Items l is ted below be withheld fro m publi c i nspection in accordance to sectio ns 0.4 57 and 0.459 of the Commission’s Rules for FCC. This due to the following reasons: Ericsson Base Stations (BS) are designed strictly based on the technical specifications of the international project 3GPP (the 3rd Generation Partnership Project). The competition in this f iel d is very i ntense and a less advanced solution/design could get an unfair advantage by accessing the information as listed below from common domain. As we believe that we have i mplemented groundbreaking solutions and designs into our r ecent BS/Radio Unit (RU) / Remote Radio Unit ( RRU) / Antenna Integrated Radio (AIR) / Radio Dot ( RD) compared to the previous BS/RU/RRU/AIR/RD, the listed Exhibits/Items need to be protected fro m disclosure to our competitors in the industry. As the FCC records have in-depth information and a very wide distribution, we believe that you can understand our concerns. We are strong in our belief that all v endors in the industry need to compete by their own merits. We regard these Exhibits/Items to be our intellectual property and therefore as confidential information. There are advanced technical and design solutions/information in the Exhibits/Items, as mentioned above, that we regard as Ericsson proprietary, with actual a nd potential patents pending. The information can be advantageous to our competitors as well as sources seeking ways to hack past the built i n security f unctionality. These solutions or information thereof are not accessible even for our customers or partners unless non-disclosure agreements for particular item(s) have been signed. Confidential product information can be found in, but not necessarily l imited to, internal photos of the BS RU RRU AIR and RD, block diagrams, schematics diagrams, and parts lis ts as well as certai n documents, such as the user’s manuals. Those documents can onl y be accessible by the customers who purchase out BS/RU/RRU/RD and accept the conditions and therefore are provided with unique i nformation access tools. EXHIBIT 9 Internal Photos EXHIBIT 10 Parts List EXHIBIT 5 Schematics EXHIBIT 8 Manuals EXHIBIT 12 Technical Circuit Description .......................................................... Lars Wallin Quality and Release Management – Regulatory Approval FCC Registration Number (FRN): 0013476155 Torshamnsgatan 23 SE-164 80 Stockholm Sweden Telephone No. +46 70 267 00 42 e-mail: [email protected]

External Photos

Exhibit 3 – External Photos Confidentiality Class External Confidentiality Label Document Type Page Ericsson Internal 1 (1) Prepared By (Subject Responsible) Approved By (Document Responsible) Checked ERAWALA Document Number Revision Date Reference A 2020-05-18 FCC ID: TA8AKRX10102 External photos: See photo 1-6 at page 2-3 in Exhibit 9 - Internal photos.

ID Label/Location Info

Exhibit 1 - FCC ID label and placement Confidentiality Class External Confidentiality Label Document Type Page Ericsson Internal 1 (1) Prepared By (Subject Responsible) Approved By (Document Responsible) Checked ERABLH Bertil Johansson K Document Number Revision Date Reference B 2020-05-18 1 FCC ID: TA8AKRX10102 Module front side. Host(s) will be marked visible from outside as: The labels are plastic stickers affixed to the product(s) via permanent adhesive. They are designed to last the expected lifetime of the products in the environment in which the products are to be operated. FCC ID: TA8AKRX10102 Contains FCC ID: TA8AKRX10102

RF Exposure Info

1 (13) GFTL-20:000420 Uen, Rev A, 2020-03-27 © Telefonaktiebolaget LM Ericsson AB. This report shall not be reproduced except in full, without written approval of the laboratory. EMF Test Report: Ericsson AIR 1281 B260 (FCC) Ackred. Nr 1761 Provning ISO/IEC 17025 Rapport utfärdad av ackrediterat provningslaboratorium Test report issued by an Accredited Testing Laboratory Document number: GFTL-20:000420 Uen Rev A Date of report: 2020-03-27 (Rev A) Testing laboratory: Ericsson EMF Research Laboratory Ericsson AB SE-164 80 Stockholm Sweden Company/Client: Per Norling EAB - Ericsson AB Blåfjällsgatan 4 164 80 Stockholm Sweden Tests performed by: Paramananda Joshi Dates of tests: 2020-03-27 (Rev A) Manufacturer and market name(s) of device: Ericsson AIR 1281 B260 Testing has been performed in accordance with: FCC OET Bulletin 65 IEC 62232:2017 Test results: RF exposure compliance boundaries (exclusion zones) related to the limits in FCC 47 CFR 1.1310 to be included in the Customer Product Information (CPI) for Ericsson AIR 1281 B260. Additional information: Signature: Test Engineer __________________ Paramananda Joshi Senior Researcher [email protected] Tel: +46 10 711 00 06 Laboratory and Quality Manager _______________________________ Christer Törnevik Senior Expert – EMF and Health [email protected] Tel: +46 10 714 12 35 2 (13) GFTL-20:000420 Uen, Rev A, 2020-03-27 Summary of EMF Test Report 1 Equipment under test (EUT) Product name AIR 1281 B260 Product number KRD 901 166/4 Supported bands, Tx frequency range (GHz) and standards B260 37– 40 NR Duplexing technology and fraction of downlink transmission time to total time TDD (75 %) Exposure environment General public/uncontrolled, Workers/controlled EIRP 2 (dBm) and IEC 62232 installation class [4] 52.0 E+ Results RF exposure compliance boundaries, outside of which the exposure is below the general public (GP) and workers (W) exposure limits, are listed below. Dimensions of the box-shaped compliance boundary for general public (GP) and workers (W) exposure for AIR 1281 B260 applicable in the USA and markets employing the FCC RF exposure limits. The compliance boundaries are determined for maximum nominal output power with power tolerance and TDD downlink duty cycle included. Mode and output power for AIR 1281 Dimensions of the box-shaped compliance boundary (m) Distance in front of EUT Width Height Distance behind EUT Band Standard Config Mode 3 Maximum nominal output power (W) Nominal total EIRP (dBm) Power tolerance (dB) TDD DL duty cycle Sector shapes GP W GP W GP W GP W B260 NR 2 0.263 53 1.5 75 % Hotspot2, Hotspot4, Hotspot5, Macro3, Macro3(7.5 deg tilt), Macro10 1.4 0.6 1.6 0.7 0.7 0.7 0.2 0.2 Macro9, Macro11 1.4 0.6 1.6 0.8 0.7 0.7 0.2 0.2 For the power levels specified in the table which include tolerances, and the upward rounding of compliance boundary dimensions to the nearest decimeter, the specified results are conservative. 1 This page contains a summary of the test results. The full report provides a complete description of all test details and results. 2 The stated EIRP value is the maximum total EIRP with the TDD downlink duty cycle and without power tolerance included and is obtained using the antenna patterns provided by the client. 3 Configuration Mode. 3 (13) GFTL-20:000420 Uen, Rev A, 2020-03-27 1 General information The test results presented in this report define compliance boundaries for AIR 1281 B260. Outside of these compliance boundaries, the radio frequency (RF) exposure levels are below the limits specified by the Federal Communications Commission (FCC) [1]. The tests were performed by calculations in accordance with the Ericsson RF exposure calculation procedure for base stations [2], which is in conformity with the FCC OET Bulletin 65 [3] and IEC 62232:2017 [4]. It should be noted that the test results presented in this test report are valid for the frequency range specified in Table 1, for the antenna properties specified in Table 2, and for the power levels, the power tolerance and the TDD downlink duty cycle specified in Table 3. These data as well as the applied antenna pattern files were supplied by the client and may affect the validity of the results. Proposed EMF health and safety information for inclusion in the Customer Product Information (CPI) is provided in Appendices A, B and C. 2 Equipment under test Table 1 and Table 2 below summarize the technical data for the equipment under test (EUT) and the properties of the integrated antenna. Table 3 lists the maximum nominal output power from the radio unit (total peak power from all antenna branches) and the total time-averaged power delivered to the antenna for the specified configuration. The total time-averaged power delivered to the antenna includes output power tolerance and TDD downlink duty cycle for Configuration Mode 2. In Configuration Mode 2, the full array, containing 4 × 24 subarrays, can generate two beams, one for each polarization. The EUT related data in Tables 1-3 were supplied by the client. Table 1 Technical data for the EUT. Product name and product number AIR 1281 B260 KRD 901 166/4 Supported bands, Tx frequency range (GHz) and standards B260 37–40 NR Dimensions, H × W × D (mm) 279 × 200 × 130 Duplexing technology and fraction of downlink transmission time to total time TDD (75 %) Exposure environment General public/uncontrolled, Workers/controlled EIRP 2 (dBm) and IEC 62232 installation class [4] 52.0 E+ Table 2 Properties of the integrated antenna. Type Phased Array Antenna Module (PAAM) Number of antenna panels 1 (Configuration Mode 2) Nominal maximum gain (dBi) 29.2 (Configuration Mode 2) Horizontal HPBW 4 (degrees) 4.1 Vertical HPBW 4 (degrees) 10.4 (Configuration Mode 2) Number of antenna elements (푵 퐇 ,푵 퐕 ) per antenna panel (24, 8) (2 polarizations) for Configuration Mode 2 Element separation distance (횫 퐇 ,횫 퐕 ) (mm) (3.9, 4.78) Maximum scan range in horizontal plane (degrees) ±60 Maximum scan …

Text truncated - open the document above for the full version.

RF Exposure Info

1 (13) GFTL-20:000331 Uen, Rev A, 2020-03-13 © Telefonaktiebolaget LM Ericsson AB. This report shall not be reproduced except in full, without written approval of the laboratory. EMF Test Report: Ericsson Streetmacro 6701 B260 (FCC) Ackred. Nr 1761 Provning ISO/IEC 17025 Rapport utfärdad av ackrediterat provningslaboratorium Test report issued by an Accredited Testing Laboratory Document number: GFTL-20:000331 Uen Rev A Date of report: 2020-03-13 (Rev A) Testing laboratory: Ericsson EMF Research Laboratory Ericsson AB SE-164 80 Stockholm Sweden Company/Client: Charles Guo CBC - Ericsson (China) Communications Co. Ltd ET2, No.5 Lize East street, Chaoyang District 100102 Beijing China Tests performed by: Bo Xu Dates of tests: 2020-03-11 (Rev A) Manufacturer and market name(s) of device: Ericsson Streetmacro 6701 B260 Testing has been performed in accordance with: FCC OET Bulletin 65 IEC 62232:2017 Test results: RF exposure compliance boundaries (exclusion zones) related to the limits in FCC 47 CFR 1.1310 to be included in the Customer Product Information (CPI) for Ericsson Streetmacro 6701 B260. Additional information: Signature: Test Engineer _____________________________ Bo Xu Experienced Researcher [email protected] Tel: +46 10 713 13 84 Laboratory and Quality Manager _______________________________ Christer Törnevik Senior Expert – EMF and Health [email protected] Tel: +46 10 714 12 35 2 (13) GFTL-20:000331 Uen, Rev A, 2020-03-13 Summary of EMF Test Report 1 Equipment under test (EUT) Product name Streetmacro 6701 B260 Product number KRK 101 02/11, KRK 101 02/1 Supported bands, Tx frequency range (GHz) and standards B260 37–40 NR Duplexing technology and fraction of downlink transmission time to total time TDD (75 %) Exposure environment General public/uncontrolled, Workers/controlled EIRP 2,3 (dBm) and IEC 62232 installation class [4] 52.0 E+ Results RF exposure compliance boundaries, outside of which the exposure is below the general public (GP) and workers (W) exposure limits, are listed below. Dimensions of the box-shaped compliance boundary for general public (GP) and workers (W) exposure for Streetmacro 6701 applicable in the USA and markets employing the FCC RF exposure limits for maximum nominal output power with power tolerance and TDD downlink duty cycle included. Mode and output power for Streetmacro 6701 Dimensions of the box-shaped compliance boundary (m) Distance in front of EUT Width Height Distance behind EUT Band Standard Config Mode 4 Maximum nominal output power (W) Nominal total EIRP (dBm) Power tolerance (dB) TDD DL duty cycle Sector shapes GP W GP W GP W GP W B260 NR 2 0.263 53 1.5 75 % Hotspot2, Hotspot4, Hotspot5, Macro3, Macro3(7.5 deg tilt), Macro10 1.4 0.6 1.6 0.7 1.0 1.0 0.2 0.2 Macro9, Macro11 1.4 0.6 1.6 0.8 1.0 1.0 0.2 0.2 For the power levels specified in the table which include tolerances, and the upward rounding of compliance boundary dimensions to the nearest decimeter, the specified results are conservative. 1 This page contains a summary of the test results. The full report provides a complete description of all test details and results. 2 The stated EIRP value is the maximum total EIRP with the TDD downlink duty cycle and without power tolerance included and is obtained using the antenna patterns provided by the client. 3 These values are provided for the power levels selected for testing. 4 Configuration Mode. 3 (13) GFTL-20:000331 Uen, Rev A, 2020-03-13 1 General information The test results presented in this report define compliance boundaries for Streetmacro 6701 B260. Outside of these compliance boundaries, the radio frequency (RF) exposure levels are below the limits specified by the Federal Communications Commission (FCC) [1]. The tests were performed by calculations in accordance with the Ericsson RF exposure calculation procedure for base stations [2], which is in conformity with the FCC OET Bulletin 65 [3] and IEC 62232:2017 [4]. It should be noted that the test results presented in this test report are valid for the frequency range specified in Table 1, for the antenna properties specified in Table 2, and for the power levels, the power tolerance and the TDD downlink duty cycle specified in Table 3. These data as well as the applied antenna pattern files were supplied by the client and may affect the validity of the results. Proposed EMF health and safety information for inclusion in the Customer Product Information (CPI) is provided in Appendices A, B and C. 2 Equipment under test Tables 1 and Table 2 below summarize the technical data for the equipment under test (EUT) and the properties of the integrated antenna. Table 3 lists the maximum nominal output power from the radio unit (total peak power from all antenna branches) and the total time-averaged power delivered to the antenna for the specified configuration. The total time-averaged power delivered to the antenna includes output power tolerance and TDD downlink duty cycle for Configuration Mode 2. In Configuration Mode 2, the full array, containing 4 × 24 subarrays, can generate two beams, one for each polarization. The EUT related data in Tables 1-3 were supplied by the client. Table 1 Technical data for the EUT. Product name and product number Streetmacro 6701 B260 KRK 101 02/11, KRK 101 02/1 Supported bands, Tx frequency range (GHz) and standards B260 37–40 NR Dimensions, H × W × D (mm) 511 × 200 × 125 Duplexing technology and fraction of downlink transmission time to total time TDD (75 %) Exposure environment General public/uncontrolled, Workers/controlled EIRP 2,3 (dBm) and IEC 62232 installation class [4] 52.0 E+ Table 2 Properties of the integrated antenna. Type Phased Array Antenna Module (PAAM) Number of antenna panels 1 (Configuration Mode 2) Nominal maximum gain (dBi) 29.2 (Configuration Mode 2) Horizontal HPBW 5 (degrees) 4.1 Vertical HPBW 5 (degrees) 10.4 (Configuration Mode 2) Number of antenna elements (푵 퐇 ,푵 퐕 ) per antenna panel (24, 8) (2 polarizat…

Text truncated - open the document above for the full version.

Test Report

Calibration certificates RISE equipment used for test report 2P03617 Serial number on equipment RISE number File name/ Page number R&S FSW 43 100 560 902 073 902 073 FSW43.pdf R&S ESU 26 100 409 901 553 901 553 ESU26.pdf R&S ZNB 40 101 544 BX50051 BX50051 ZNB40.pdf Bilog antenna Schaffner 6143A 23 169 504 079 2 – 9 EMCO Horn Antenna 3115 9509-4562 502 175 10 – 14 EMCO Horn Antenna 3115 00143 161 902 212 15 – 19 EMCO Horn Antenna 3116 9904-2426 503 279 20 – 24 Mixer FS-Z60 100 996 BX90566 25 – 31 Mixer FS-Z90 101 871 BX90567 32 – 38 Mixer FS-Z110 101 467 BX81425 39 – 48 Mixer FS-Z170 100 974 BX81426 49 – 55 Mixer FS-Z220 100 967 BX81427 56 – 62 Flann STD Gain Horn Antenna 20240-20 Manufacturer provided gain 407 BX92412 63 Flann STD Gain Horn Antenna 22240-20 Manufacturer provided gain 258 660 BX92413 64 Flann STD Gain Horn Antenna 24240-20 Manufacturer provided gain 141 BX92414 65 Flann STD Gain Horn Antenna 26240-20 Manufacturer provided gain 124 440 BX92416 66 Flann STD Gain Horn Antenna 27240-20 Manufacturer provided gain 281 BX92417 67 Flann STD Gain Horn Antenna 29240-20 Manufacturer provided gain 46 BX92419 68 Flann STD Gain Horn Antenna 30240-20 Manufacturer provided gain 29 BX92420 69 Calibration Certificate Certificate Number 24-0170-100974-01 Kalibrierschein Zertifikatsnummer Unit Data This calibration certificate documents, that the named item is tested and measured against defined specifications. Measurement results are located usually in the corresponding interval with a probability of approx. 95% (coverage factor k = 2). Calibration is performed with test equipment and standards directly or indirectly traceable by means of approved calibration techniques to the PTB/DKD or other national/international standards, which realize the physical units of measurement according to the International System of Units (SI). In all cases where no standards are available, measurements are referenced to standards of the R&S laboratories. Principles and methods of calibration correspond with EN ISO/IEC 17025. This calibration certificate may not be reproduced other than in full. Calibration certificates without signatures are not valid. The user is obliged to have the object recalibrated at appropriate intervals. Item Harmonic Mixer, 110 GHz to 170 GHz Gegenstand Manufacturer RPG Hersteller Type RPG FS-Z170 Typ Material Number 3622.0714.02 Serial Number 100974 Materialnummer Seriennummer Asset Number Inventarnummer Order Data Customer Auftraggeber Dieser Kalibrierschein dokumentiert, dass der genannte Gegenstand nach festgelegten Vorgaben geprüft und gemessen wurde. Die Messwerte lagen im Regelfall mit einer Wahrscheinlichkeit von annähernd 95% im zugeordneten Werteintervall (Erweiterte Messunsicherheit mit k = 2). Die Kalibrierung erfolgte mit Messmitteln und Normalen, die direkt oder indirekt durch Ableitung mittels anerkannter Kalibriertechniken rückgeführt sind auf Normale der PTB/DKD oder anderer nationaler/internationaler Standards zur Darstellung der physikalischen Einheiten in Übereinstimmung mit dem Internationalen Einheitensystem (SI). Wenn keine Normale existieren, erfolgt die Rückführung auf Bezugsnormale der R&S-Laboratorien. Grundsätze und Verfahren der Kalibrierung beziehen sich auf EN ISO/IEC 17025. Dieser Kalibrierschein darf nur vollständig und unverändert weiterverbreitet werden. Kalibrierscheine ohne Unterschriften sind ungültig. Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich. Order Number Bestellnummer Date of Receipt Eingangsdatum Performance Place and Date of Calibration Meckenheim, 2018-02-05 Ort und Datum der Kalibrierung Scope of Calibration Standard Calibration Umfang der Kalibrierung Statement of Compliance New device (Incoming) Konformitätsaussage (Anlieferung) Statement of Compliance All measured values are within the data sheet specifications. (Outgoing) Konformitätsaussage (Auslieferung) Extend of Calibration Documents 2 pages Calibration Certificate 5 pages Outgoing Results Umfang des Kalibrierdokuments Radiometer Physics GmbH; Meckenheim Date of Issue Head of Laboratory Person Responsible Ausstellungsdatum Laborleitung Bearbeiter 2018-02-05 Schulze Dick Page (Seite) 1/2 Vers2010-05-05/ RPG2014-02-28 Radiometer Physics GmbH ● Werner-von-Siemens-Str. 4 ● 53340 Meckenheim ● Telephone national: 02225/99981-0 international: 0049 2225-99981-0 Fax: 02225/99981-99 ● Managing Director: Achim Walber, Dr. Thomas Rose ● Company's Place of Business: Meckenheim Commercial Register No.: Bonn, HRB 10291 ● VAT Identification No.: DE 123 377 395 Material Number 3622.0714.02 Serial Number 100974 Certificate Number 24-0170-100974-01 Page 2/2 Calibration Method RPG-PAQA-TN-2014-002 Relative Humidity 20 % - 80 % Kalibrieranweisung Relative Luftfeuchte Ambient Temperature (23 +7 -3 ) °C Umgebungstemperatur Working standards used (having a significant effect on the accuracy) Verwendete Gebrauchsnormale (mit signifikantem Einfluss auf die Genauigkeit) Item Gegenstand Type Typ Serial Number Seriennummer Calibration Certificate Number Kalibrierscheinnummer Cal. Due Kalibr. bis Vector Network Analyzer R&S® ZVA67 101097 20-300432406 2020-07-21 Powersensor R&S® NRP-Z55 140093 20-300426315 2018-05-17 UGB1 A compliance statement may be possible where a confidence level of less than 95 % is acceptable. Die Bestätigung der Konformität ist möglich, sofern ein Grad des Vertrauens von weniger als 95 % akzeptabel ist. UGB2 A non-compliance statement may be possible where a confidence level of less than 95 % is acceptable. Die Bestätigung der Nicht-Konformität ist möglich, sofern ein Grad des Vertrauens von weniger als 95 % akzeptabel ist. Ref.: ILAC-G8:03/2009 ‘Guidelines on the Reporting of Compliance with Specification’. Notes Anmerkungen If the new product is stored under the climate conditions as specified in the data sheet upon delivery, the product’s accuracy is not significantly affected within 12 month after its calibration in…

Text truncated - open the document above for the full version.

Test Report

Scope of accreditation Designated body RISE Research Institutes of Sweden ABBoråsAccreditation number1002 Enheten för elektronikA002626-054 Canada IT- and communications testing Technical areaMaterialMethodSpecificationMeasure Radio frequencyRadio equipmentRSS-130 Issue 1 RSS-132 Issue 3 RSS-133 Issue 6 RSS-139 Issue 3 RSS-140 Issue 1 RSS-195 Issue 2 RSS-199 Issue 3 RSS-210 Issue 9 RSS-247 Issue 2 RSS-Gen Issue 5 USA IT- and communications testing Technical areaMaterialMethodSpecificationMeasure EMCRadio equipmentANSI C63.4:2014FCC CFR 47 part 11 FCC CFR 47 part 15 FCC MP-5:1986FCC CFR 47 Part 18 Radio frequencyRadio communicationTIA-102.CAAA-D Radio equipmentANSI C63.10:2013FCC CFR 47 part 15Max frequency 220 GHz ANSI C63.26:2015Max frequency 220 GHz FCC CFR 47 Part 101Max frequency 220 GHz Sida 1 (2) Appendix 2 ReferenceDate 2019-01-24 2018/2780 IT- and communications testing Technical areaMaterialMethodSpecificationMeasure Radio frequencyRadio equipmentANSI C63.26:2015FCC CFR 47 Part 2Max frequency 220 GHz FCC CFR 47 Part 22Max frequency 220 GHz FCC CFR 47 Part 24Max frequency 220 GHz FCC CFR 47 Part 25Max frequency 220 GHz FCC CFR 47 Part 27Max frequency 220 GHz FCC CFR 47 Part 30Max frequency 220 GHz FCC CFR 47 Part 73Max frequency 220 GHz FCC CFR 47 Part 74Max frequency 220 GHz FCC CFR 47 Part 90Max frequency 220 GHz FCC CFR 47 Part 95Max frequency 220 GHz FCC CFR 47 Part 96Max frequency 220 GHz FCC CFR 47 Part 97Max frequency 220 GHz ANSI/TIA-603-D KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02 Changes in the scope of accreditation are in bold. Sida 2 (2) Appendix 2 ReferenceDate 2019-01-24 2018/2780

Test Report

R Kalibrierlaboratorium für Geräte der Nachrichtentechnik Calibration laboratory for measuring instruments of telecommunication engineering akkreditiert durch die / accredited by the Deutsche Akkreditierungsstelle GmbH als Kalibrierlaboratorium im / as calibration laboratory in the Deutschen Kalibrierdienst DKD D-K- KalibrierscheinKalibrierzeichen 15012-01-00 Calibration CertificateCalibration Mark 2019-07 GegenstandEMI Test Receiver Object HerstellerROHDE & SCHWARZ Manufacturer TypESU26 Type Fabrikat/Serien-Nr.100409 Serial number Inventarienummer: 901553 AuftraggeberRISE Research Institutes of Sweden Customer Brinellgatan 4 504 62 Borås Sweden Auftragsnummer226298 Order No. Anzahl der Seiten des Kalibrierscheins30 Number of pages of the certificate Ort und Datum der KalibrierungBorås, 2019-07-18 Place and date of calibration Dieser Kalibrierschein darf nur vollständig und unverändert weiterverbreitet werden. Auszüge oder Änderungen bedürfen der Genehmi- gung sowohl der Deutschen Akkreditierungsstelle als auch des ausstellenden Kalibrierlaboratoriums. Kalibrierscheine ohne Unterschrift haben keine Gültigkeit. This calibration certificate may not be reproduced other than in full except with the permission of both the German Accreditation Body and the issuing laboratory. Calibration certificates without signature are not valid. Datum Bearbeiter Date Deputy head of the calibration laboratoryPerson in charge T68La/HulLqzath++v439dvyG+p1r2AI1v49g6XBE4/aaTGxfZQGtbGJP8SUmlQe D9QOYQReiHHNGvWA2JaUSf7EqTuAfQopgQtCV0Q8OHnPTzN3opIKemR+bcAUAHHo7UEyjctyeb8LPzAXQU04Sw== 2019-08-01 Ralf SchwagereitUlrich Lohner ROHDE & SCHWARZ GmbH & Co. KG · International Service · Graf-Zeppelin-Straße 18 · D-51147 Köln Postfach 98 02 60 · D-51130 Köln · Telefon: (02203) 49-0 · Telefax: (02203) 49-51364 · Durchwahl: 49 - 51433Vers2010-09/RSK2016-04 1981M008 Stellv. Leiter des Kalibrierlaboratoriums Dieser Kalibrierschein dokumentiert die Rückführung auf nationale Normale zur Darstellung der Einheiten in Übereinstim- mung mit dem Internationalen Einheiten- system (SI). Die DAkkS ist Unterzeichner der multila- teralen Übereinkommen der European co- operation for Accreditation (EA) und der International Laboratory Accreditation Co- operation (ILAC) zur gegenseitigen Aner- kennung der Kalibrierscheine. Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich. This calibration certificate documents the traceability to national standards, which realize the units of measurement accor- ding to the International System of Units (SI). The DAkkS is signatory to the multilateral agreements of the European cooperation for Accreditation (EA) and of the Interna- tional Laboratory Accreditation Coopera- tion (ILAC) for the mutual recognition of calibration certificates. The user is obliged to have the object re- calibrated at appropriate intervals. ObjectEMI Test Receiver R TypeESU26Serial No.100409 International Service Date2019-07-18Material No.1302.6005K26 Page2 of 30Calibration Mark1981M008-D-K-15012-01-00-2019-07 V1-08/Temp/Eng/2016-01 Object Data Firmware version:4.73 Installed options:B2, B16, B24 Calibration Procedure Measurement Results see from page 4 on All measurement results are metrologically traced to the International System of Units (SI) by means of an unbroken chain of calibrations to relevant primary standards of the SI units of measurements. Statement of Compliance Incoming:All measured values are within the datasheet specifications. Outgoing:All measured values are within the datasheet specifications. Working Standards used ItemTypeSerial NumberCalibration Certificate NumberCal. Due Signal GeneratorSMB100A180744719114-D-K-15195-01-01-2018-032020-03 Signal GeneratorSMA100A110564K17-1314-D-K-15012-01-00-2017-122019-12 Signal GeneratorSMP04100050492304-D-K-15195-01-01-2018-122019-12 Step AttenuatorRSG831001/002482594-D-K-15195-01-01-2018-102019-10 Power MeterNRVD100084K18-1414-D-K-15012-01-00-2018-112019-11 Power SensorNRV-Z5892957/013484071-D-K-15195-01-01-2018-102019-10 Power MeterNRP2103572K18-411-D-K-15012-01-00-2018-042020-04 Power SensorNRP-Z55130170K19-484-D-K-15012-01-00-2019-062020-06 Power SensorNRP-Z85101057513506-D-K-15195-01-01-2019-062020-06 EMI Calibration Pulse Gen.IGUU29182918191465476-D-K-15195-01-01-2018-052019-11 SWR BridgeZRC827875/010514217-D-K-15195-01-01-2019-062020-06 Directional Coupler102040013K137752K19-682-D-K-15012-01-00-2019-062020-06 Frequency Standard910R396686K17-1094-D-K-15012-01-00-2017-092019-09 Remarks SelfTest passed TotalCal passed The calibration was performed according to service manual 1302.6163.82-04 following the procedures as described in calibration guideline VDI/VDE/DGQ/DKD 2622 part 12 by compairing the relevant measurands of the instrument under test with the numerical values of the quantities represented by the reference standards used. The receiver fulfills the requirements of the international standard CISPR 16-1- 1:2010+A1:2010. ObjectEMI Test Receiver R TypeESU26Serial No.100409 International Service Date2019-07-18Material No.1302.6005K26 Page3 of 30Calibration Mark1981M008-D-K-15012-01-00-2019-07 V1-08/Temp/Eng/2016-01 Measurement Uncertainty Together with the results on the following pages the extended measurement uncertainty is stated which was calculated from the standard measurement uncertainty multiplied by the coverage factor k = 2. It was determined in accordance with EA-4/02 M: 2013. The true value is located in the corresponding interval with a probability of 95 %. Environmental Conditions Ambient temperature(23 ± 3) °CRelative humidity(45 ± 30) % Comments on the measured results The measurement results in the test report stated below have been tested for compliance with the given specifications and marked if necessary. In doing so, the associated uncertainty of measurement has been taken into acount. The following abbrevations may be used in this certificate: ¹ Measurement results that are not cover…

Text truncated - open the document above for the full version.

Test Report

akkreditiert durch die / accredited by the Deutsche Akkreditierungsstelle GmbH als Kalibrierlaboratorium im / as calibration laboratory in the Deutschen Kalibrierdienst 518327 KalibrierscheinKalibrierzeichen D-K- 15195-01-01 Calibration certificateCalibration mark 2019-09 Gegenstand Object FSW43 SPECTRUM ANALYZER 43GHZ Dieser Kalibrierschein dokumentiert die Rück- führung auf nationale Normale zur Darstellung der Einheiten i…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Peter Moberg(Head of PEU Radio)
[email protected]+46 10 719 00 00Fax: +46 10 716 00 28

Technical Contact

Ericsson ABLars Wallin
[email protected]+46702670042

Torshamnsgatan 23 · Stockholm · Sweden

Test Firm

RISE Research Institutes of Sweden ABDaniel Lundgren
[email protected]+46 10 516 5836

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
2337.05 GHz - 39.95 GHz45.8 W400MW7D0.05 ppm
Modular Type
Limited Single Modular Approval
Confidentiality
Long Term
Grant Notes
The power output listed is Maximum EIRP/ 100 MHz. This transmitter must only be integrated in the grantees own end products and must only be operated in the grantees RBS systems. Compliance of end product configurations with this transmitter is the responsibility of the Grantee. End products must be fixed-mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3).

Other Applications from Ericsson AB

Multi-standard remote radio - FCC ID TA8BKRD901316 - Ericsson AB
TA8BKRD901316

Multi-standard remote radio

Sep 02, 2026

Equipment Class

PCB - PCS Licensed Transmitter
Radio Unit - FCC ID TA8BKRY901523 - Ericsson AB
TA8BKRY901523

Radio Unit

Jul 23, 2026

Equipment Class

PCB - PCS Licensed Transmitter
Radio Unit - FCC ID TA8BKRY901515 - Ericsson AB
TA8BKRY901515

Radio Unit

Jul 23, 2026

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Radio Unit - FCC ID TA8BKRY901551 - Ericsson AB
TA8BKRY901551

Radio Unit

Jul 06, 2026

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Multi-standard remote radio - FCC ID TA8AKRD901316 - Ericsson AB
TA8AKRD901316

Multi-standard remote radio

Jun 29, 2026

Equipment Class

PCB - PCS Licensed Transmitter