Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
>10A
1 2 3 4 56 A BC D 6 5 4 3 2 1 D CB A Title Number Revision Size B Date: 29-Oct-2003 Sheet of File: E:\PSY18B\PSY18B.ddb Drawn By: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 CN1 1 2 CN1 FAN 1 2 3 CN2 T_MAIN 12 CN3 T_IGBT AC N Pot Temperature Detection AC L OUT1 OUT2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 CN4 A -+ Conrtol and Display Board Main Board Power Junction Pole Coil Junction Pole Thermisor Fan IGBT Heatsink Commutate Bridge Heatsink IBGT Thermisor Coil Power Plug
SGS-CSTC Standards Technical Services Co., Ltd . No.198 Kezhu Road, Science Town Economic& Technology Development District Guangzhou, China 510663 Telephone: +86 (0) 20 82155555 Fax: +86 (0) 20 82075059 Email: [email protected] Report No.: GLEMO050300771HSF Page: 1 of 12 FCC ID: TAPMC-ESH13A Authorized Signature: Jeff Zhao Manager This report refers to the General Conditions for Inspection and Testing Services, printed overleaf This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International Electrical Approvals in writing. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. All test results in this report can be traceable to National or International Standards. Member of the SGS Group (SGS SA) FCC Test Report Application No.: GLEMR060801162HS Applicant: Guangdong MD Consume Electric Manufacturing Co.,Ltd Equipment Under Test (EUT): EUT Name: Induction Cooker Item No.: MC-JSH13A Serial No.: Not supplied by client Standards: FCC PART 18: 2004 Date of Receipt: 28 August 2006 Date of Test: 03 to 06 September 2006 Date of Issue: 08 September 2006 Test Result : PASS* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd . Report No.: GLEMO040700699LME Page: 2 of 12 FCC ID: TAPMC-ESH13A 2 Test Summary Test Test RequirementTest Method Class / SeverityResult Radiated Emission (9KHz to 30MHz) FCC PART 18: 2004 FCC OSZ/ MP-5:1986 18.305 PASS Conducted Emission (9KHz to 30MHz) FCC PART 18: 2004 FCC OSZ/ MP-5:1986 18.307(a) PASS SGS-CSTC Standards Technical Services Co., Ltd . Report No.: GLEMO040700699LME Page: 3 of 12 FCC ID: TAPMC-ESH13A 3 Contents Page 1 COVER PAGE ............................................................................................................................................1 2 TEST SUMMARY .......................................................................................................................................2 3 CONTENTS ................................................................................................................................................3 4 GENERAL INFORMATION........................................................................................................................4 4.1 CLIENT INFORMATION................................................................................................................................4 4.2 GENERAL DESCRIPTION OF E.U.T. ............................................................................................................4 4.3 DETAILS OF E.U.T. ...................................................................................................................................4 4.4 DESCRIPTION OF SUPPORT UNITS.............................................................................................................4 4.5 STANDARDS APPLICABLE FOR TESTING......................................................................................................4 4.6 TEST LOCATION........................................................................................................................................4 4.7 TEST FACILITY..........................................................................................................................................5 4.8 DEVIATION FROM STANDARDS...................................................................................................................5 4.9 ABNORMALITIES FROM STANDARD CONDITIONS..........................................................................................5 5 EQUIPMENTS USED DURING TEST .......................................................................................................6 6 TEST RESULTS .........................................................................................................................................7 6.1 RADIATED EMISSION, 9KHZ TO 30MHZ......................................................................................................7 6.1.1 E.U.T. Operation ............................................................................................................................7 6.1.2 Measurement Data ........................................................................................................................7 6.2 INDUCTED EMISSIONS, 0.15MHZ TO 30MHZ............................................................................................10 6.2.1 E.U.T. Operation ..........................................................................................................................10 6.2.2 Measurement Data ................................................................................................................ 10-12 SGS-CSTC Standards Technical Services Co., Ltd . Report No.: GLEMO040700699LME Page: 4 of 12 FCC ID: TAPMC-ESH13A 4 General Information 4.1 Client Information Applicant: Guangdong MD Consume Electric Manufacturing Co.,Ltd Address of Applicant: 19 Sanle Road, Bejiao, Shunde, Foshan, Guangdong, P.R. China 4.2 General Description of E.U.T. EUT Name: Induction Cooker Item No.: MC-JSH13A Serial No.: Not supplied by client 4.3 Details of E.U.T. โฆ
Text truncated - open the document above for the full version.
198 Kezhu Rd, Scientech Pk Guangzhou ยท Guangzhou ยท China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.02 MHz - 0.03 MHz | - |

induction cooker
Equipment Class
8CC - Part 18 Consumer Device
induction cooker
Equipment Class
8CC - Part 18 Consumer Device
Induction Cooker
Equipment Class
8CC - Part 18 Consumer Device
induction cooker
Equipment Class
8CC - Part 18 Consumer Device
induction cooker
Equipment Class
8CC - Part 18 Consumer Device