Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
i wiTECH VCI POD User Guide Bright Star Engineering 299 Ballardvale Street, Suite 5 Wilmington, MA 01887 Tel: (978) 642-3200 Fax: (978) 642-3199 www.brightstareng.com ii FCC Regulatory statements This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. Reorient or relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference 2. This device must accept any interference received, including interference that may cause undesired operation. FCC Warning Modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment under FCC Rules. Radio Frequency Exposure This equipment has been evaluated in accordance with the FCC bulletin 56 “Hazards of radio frequency and electromagnetic fields” and bulletin 65 “ Human exposure to radio frequency and electromagnetic fields. Safe operation in an uncontrolled environment will result if the following distances from the device are maintained as a minimum. A distance greater than or equal to 20 cm from the device should be maintained. Industry Canada This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference- causing equipment standard entitled “Digital Apparatus,” ICES-003 of the Department of Communications. Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe B prescrites dans la norme sur le matériel brouilleur: “Appareils Numériques,” NMB-003 édictée par le ministère des Communications. This device complies with RSS 210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of this device.” L ‘ utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. iii Notice The information in this document is subject to change without notice. THE SOFTWARE AND DOCUMENTATION ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND INCLUDING WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FURTHER, Bright Star Engineering DOES NOT, GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING USE, OR THE RESULTS OF THE USE, OF THE SOFTWARE OR WRITTEN MATERIAL IN TERMS OF CORRECTNESS, ACCURACY, RELIABILITY, OR OTHERWISE. Restricted Rights Legend Use, duplication, or disclosure by the United States Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013. This document may not, in whole or in part, be copied, reproduced, translated, or reduced to any electronic medium or machine-readable form without prior consent, in writing, from Bright Star Engineering, Inc. Copyright © 2008 Bright Star Engineering, Inc. All Rights Reserved Printed in the USA iv Table of Contents Revision History .................................................................................................... 1 Getting Started with the Device ............................................................................ 2 Setting Up and Powering On ............................................................................. 2 Connecting to the Network ................................................................................ 2 LAN with DHCP ............................................................................................. 2 LAN with Static IP Addressing ....................................................................... 2 Device Discovery Mechanism ........................................................................... 2 Device Overview ................................................................................................... 3 LEDs ................................................................................................................. 3 Reset Button...................................................................................................... 4 Configuring Device and Network Settings ............................................................. 5 Using the HTTP Interface .................................................................................. 5 System Settings ............................................................................................. 6 Network Settings ............................................................................................ 7 Wireless Settings ........................................................................................... 8 Manage Networks .........................................................…
Text truncated - open the document above for the full version.
Letter of Authorization Company: Bright Star Engineering Address: 299 Ballardvale Street, Suite 5 Wilmington, MA 01887 Product Name: Bluetooth Smart Cable Model Number: WCB33 We authorize MiCOM Labs, 440 Boulder Court, Suite 200, Pleasanton, CA 94566, USA, to act on our behalf on all matters concerning the above named equipment. This shall include the following: - Testing - Approval applications and procedures - Payment of approval fees We declare that MiCOM Labs, 440 Boulder Court, Suite 200, Pleasanton, CA 94566, USA, is allowed to forward all information related to the approval project to the applied notified body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: Roy Nachowitz Date: March 3rd 2011 Title: Director of Operations Signature of applicant 299 Ballardvale Street, Suite5 Wilmington, MA 01887 USA Tel: +1-978-642-3200 Fax: +1-978-642-3199 www.brightstareng.com
The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information may result in application termination. Except as described in §0.459, correspondence and responses should be considered part of the permanent submission and may be viewed from the Internet after a Grant of Equipment Authorization is issued unless a request for confidentiality per Section 0.457 has been made for that particular exhibit. Please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the sender. March 23, 2011 RE: FCC and Industry Canada Review IC ID: 5945A-WCB33 / FCC ID: TE4WCB33 (MC # BSTR25) After an initial review of the submitted information, I have a few comments on the above referenced application. Depending on your responses, kindly understand there may be additional comments. Additionally, if some of the issues / concerns below are not clear, please do not hesitate to email me for clarification. 1) Please confirm applicant address. 229 Ballardvale Street, Suite 5 is listed with the FCC. 299 Ballardvale Street, Suite 5 is listed with Industry Canada. Please confirm address, and provide authorization to change with applicable agency, or provide confirmation once address has been changed with appropriate agency. Our correct address is 299 Ballardvale Street, Suite 5. 3) Schematics do not include schematics for the radio. Please provide detail. Device uses radio module WT21A; Transmitter Module FCC ID: QOQWT21A; Schematics are available via this application. 4) Operational Description does not provide any details on the radio operations. Please provide detail. Operational description reviewed; OK Clinton Bradley Technical Reviewer Mail to: [email protected]
the wireless lab Bright Star Engineering, Inc. External Photographs WCB33 SmartCable MiCOM Labs, 440 Boulder Court, Suite 200, Pleasanton, CA 94566 Tel: +1 (925) 462-0304, Fax: +1 (925) 462-0306, Web: www.micomlabs.com
Model No. WCB33 Bright Star Engineering DC INPUT: 12V 04A DC INPUT: 12V 0 . 4A ‐‐‐ FCCID:TE4WCB33 IC:5945A ‐ WCB33 MADE IN USA 2280
the wireless lab Bright Star Engineering, Inc. WCB33 SmartCable Label location Label Location MiCOM Labs, 440 Boulder Court, Suite 200, Pleasanton, CA 94566 Tel: +1 (925) 462-0304, Fax: +1 (925) 462-0306, Web: www.micomlabs.com
the wireless lab Bright Star Engineering, Inc. Internal Photographs WCB33 SmartCable MiCOM Labs, 440 Boulder Court, Suite 200, Pleasanton, CA 94566 Tel: +1 (925) 462-0304, Fax: +1 (925) 462-0306, Web: www.micomlabs.com the wireless lab Page 2 of 2
the wireless lab Maximum Permissible Exposure Calculations for Maximum Permissible Exposure Levels Power Density = Pd (mW/cm 2 ) = EIRP/(4πd 2 ) EIRP = P * G P = Peak output power (mW) G = Antenna numeric gain (numeric) d = Separation distance (cm) Numeric Gain = 10 ^ (G (dBi)/10) The peak power in the table below is calculated by assuming a worst case scenario where all of the EUT transmitters are operating simultaneously in the same band. The Peak Power in mW is the highest transmitter power measured and summed across all transmitters. Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of power density is 1.0 mW/cm 2 Freq. Band (GHz) Antenna Gain (dBi) Numeric Gain (numeric) Peak Output Power (dBm) Peak Output Power (mW) Calculated Safe Distance @ 1mW/cm 2 Limit(cm) Minimum Separation Distance (cm) 2.4 0.5 3.16 +4.86 3.06 0.88 20 *Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if calculations indicate the MPE distance to be less. Specification Maximum Permissible Exposure Limits §15.247(i) Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency levels in excess of the Commission’s guidelines. FCC §1.1310 Limit = 1mW / cm 2 from 1.310 Table 1 RSS-Gen §5.5 Before equipment certification is granted, the applicable requirements of RSS-102 shall be met. MiCOM Labs, 440 Boulder Court, Suite 200, Pleasanton, CA 94566 Tel: +1 (925) 462-0304, Fax: +1 (925) 462-0306, Web: www.micomlabs.com
Test of Brig ht Star Engineering Inc. smartCable To: FCC 47 CFR Part 15, SubPart 15.247 Test Report Serial No.: BSTR25-U1 Rev A TEST REPORT From This test report may be reproduced in full only. The document may only be updated by MiCOM Labs personnel. Any changes will be noted in the Document History section of the report. MiCOM Labs is an ISO 17025 Accredited Testing Laboratory TESTING CERTIFICATE #2381.01 Test of: Bright Star Engineering Inc smartCable To: FCC 47 CFR Part 15, SubPart 15.247 Test Report Serial No.: BSTR25-U1 Rev A This report supersedes: None Applicant:Bright Star Engineering Inc 299 Ballardvale Street Suite 5 Wilmington, MA 1887 USA Product Function: Wireless Data Communication Copy No: pdf Issue Date: 11 th March 2011 This Test Report is Issued Under the Authority of; MiCOM Labs, Inc. 440 Boulder Cour t, Suite 200 Pleasanton, CA 94566 USA Phone: +1 (925) 462-0 304 Fax: +1 (925) 462-0306 www.micomlabs.com Title: Bright Star Engineering Inc smartCable To: FCC 47 CFR Part 15, SubPart 15.247 Serial #: BSTR25-U1 Rev A Issue Date: 8th March 2011 Page: Page 3 of 117 This test report may be reproduced in full only. The document may only be updated by MiCOM Labs personnel. Any changes will be noted in the Document History section of the report. MiCOM Labs, 440 Boulder Court, Suite 200, Pleasanton, CA 94566 USA, Phone: 925.462.0304, Fax: 925.462.0306, www.micomlabs.com TABLE OF CONTENTS 1 ACCREDITATION, LISTINGS & RECOGNITION ..................................................... 5 1.1 TESTING ACCREDITATION .................................................................................... 5 1.2 RECOGNITION ......................................................................................................... 6 1.3 PRODUCT CERTIFICATION .................................................................................... 7 2 DOCUMENT HISTORY ............................................................................................... 8 3 TEST RESULT CERTIFICATE ................................................................................... 9 4 REFERENCES AND MEASUREMENT UNCERTAINTY ........................................ 10 4.1 Normative References ............................................................................................. 10 4.2 Test and Uncertainty Procedures ............................................................................ 11 5 TEST SUMMARY ...................................................................................................... 12 6 PRODUCT DETAILS AND TEST CONFIGURATIONS .......................................... 14 6.1 Test Program Scope ................................................................................................ 14 6.2 EUT Details.............................................................................................................. 16 6.3 External A.C/D.C Power Adaptor............................................................................. 17 6.4 Operational Power Range ....................................................................................... 17 6.5 Types of Modulation Supported ............................................................................... 17 6.6 Antenna Details ....................................................................................................... 17 6.7 Cabling and I/O Ports .............................................................................................. 18 6.8 EUT Configurations ................................................................................................. 18 6.9 Equipment Details.................................................................................................... 18 6.10 Test Configurations.................................................................................................. 19 6.11 Equipment Modifications.......................................................................................... 19 6.12 Deviations from the Test Standard .......................................................................... 19 Title: Bright Star Engineering Inc smartCable To: FCC 47 CFR Part 15, SubPart 15.247 Serial #: BSTR25-U1 Rev A Issue Date: 8th March 2011 Page: Page 4 of 117 This test report may be reproduced in full only. The document may only be updated by MiCOM Labs personnel. Any changes will be noted in the Document History section of the report. MiCOM Labs, 440 Boulder Court, Suite 200, Pleasanton, CA 94566 USA, Phone: 925.462.0304, Fax: 925.462.0306, www.micomlabs.com 7 TEST RESULTS ........................................................................................................ 20 7.1 20 dB and 99% Bandwidth ...................................................................................... 20 7.1.1 20 dB and 99% Bandwidth Results: .........................................................22 7.1.2 Carrier Frequency Separation ..................................................................34 7.1.3 Number of Hopping Frequencies .............................................................40 7.1.4 Time of Occupancy (Dwell Time) .............................................................44 7.1.5 Channel Occupancy .................................................................................50 7.1.6 Peak Output Power ..................................................................................57 7.1.7 Band-edge Compliance of RF Conducted Emissions ..............................71 7.1.8 Spurious RF Conducted Emissions - Transmitter ....................................80 7.1.9 Spurious RF Conducted Emissions - Receiver ........................................87 7.1.10 Pseudorandom Frequency Hopping Sequence .......................................90 7.1.11 Equal Hopping Frequency Use ................................................................91 7.1.12 System Receiver Input Bandwidth ...........................................................92 7.1.13 System Rece…
Text truncated - open the document above for the full version.
the wireless lab Bright Star Engineering, Inc. Test Setup Photographs WCB33 SmartCable Conducted RF Emissions - EUT MiCOM Labs, 440 Boulder Court, Suite 200, Pleasanton, CA 94566 Tel: +1 (925) 462-0304, Fax: +1 (925) 462-0306, Web: www.micomlabs.com the wireless lab Conducted RF Emissions - Test Equipment Page 2 of 4 the wireless lab Transmitter Radiated Spurious Emission below 1 GHz Page 3 of 4 the wireless lab Receiver Radiated Emissions above 1 GHz Page 4 of 4
299 Ballardvale Street · Wilmington, Massachusetts · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 4.00 mW | 1M16F1D | 20.0000000000 ppm |

Automotive Diagnostic Tool
Equipment Class
DTS - Digital Transmission System
Automotive Diagnostic Scan Tool
Equipment Class
DTS - Digital Transmission System
Automotive Diagnostic Scan Tool
Equipment Class
DTS - Digital Transmission System