FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. COLIGEN Corp./
  3. TFKRFDP4841

TFKRFDP4841Parking Sensor Display

COLIGEN Corp.
Parking Sensor Display - FCC ID TFKRFDP4841 - COLIGEN Corp.
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Jan 11, 2006
Application Purpose
Original Equipment
Date of Application
Jan 11, 2006
Equipment Note
Parking Sensor Display
Frequency Range
915.11000000 - 916.58000000
Company
COLIGEN Corp.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Operational Description

Page 1 of 1    Product Operation Description of RFDP4841 This product is the display part of a parking sensor system, which is designed with ultrasonic technology to assist the driver to parking or reversing the vehicle. This product will be placed on the dashboard of the vehicle for display. It would be operated with the controller part of the parking sensor system. See below picture for the installation information of the system. This product is powered by the same power source, which would be DC 12V or DC 24V from the vehicle lead-acid batteries, as the reverse lights. The main function of the product is to receive the RF signal from controller part of the same system, demodulate the signal and display the distance reading in the LED display segments. RF link is setup between the product and the controller part in 2FSK half-duplex form. While in the power on handshake period, RF signal for controller ID confirmation would be transmitted from the product to the controller. Also while the ‘link’ button is pressed, RF signal for inquiry of the controller part ID will be sent out. It only happens on the first-time operation, and there is no need to press the ‘link’ button again next time unless the controller part is replaced with a new one. Integral antenna is used. The frequency range of the product is 915.11MHz, 915.85MHz and 916.58MHz. The half-duplex RF link of the system will be auto tuned to one of above channel that is available. What is more, audible beeping would be emitted from the buzzer of the product to alarm the driver of the distance of an object up to 1.5 meters.

Schematics

AVDD 1 AGND 2 RF-IN 3 RF-OUT 4 AVDD 5 AGND 6 AGND 7 AGND 8 AVDD 9 L1 10 L2 11 CHP-OUT 12 R-BIAS 13 AGND 14 AVDD 15 AGND 16 XT-OUT 17 XT-IN 18 AGND 19 DGND 20 DVDD 21 DGND 22 DIO 23 DCLK 24 PCLK 25 PDATA 26 PALE 27 RSSI/IF 28 U4 CC1000 R1 2K L41 2.5nH L62 2.5nH L91 4.7nH L42 120nH C41 10Pf C13 1Kp C2 5Pf C524pf C1 5Pf C15 27p C3 1Kp ANT C5 27P XT5 8.0MHz C4 27P C14 27p XT4 14.745MHz L210 1KnH C11 10u/6.3V PD3/INT1 1 PD4/XCK/T0 2 GND 3 VCC 4 GND 5 VCC 6 PB6/XTAL1/TOSC1 7 PB7/XTAL2/TOSC2 8 PD5/T1 9 PD6/AN0 10 PD7/AN1 11 PB0/ICP 12 PB1/OC1A 13 PB2/OC1B 14 PB3OC2/MOSI 15 PB4/MISO 16 SCK/PB5 17 AVCC 18 ADC6 19 AREF 20 GND 21 ADC7 22 ADC0/PC0 23 ADC1/PC1 24ADC2/PC2 25 ADC3/PC3 26 SDA/ADC4/PC4 27 SCL/ADC5/PC5 28 RESET/PC6 29 RXD/PD0 30 TXD/PD1 31 INT0/PD2 32 U3 ATMEGA8 1 2 3 4 J4 L2 10uH(0 OH) C8 100uF/6.3V R9 27k C28 1000Pf 3.6VD RESET MISO MOSI SCK GND +5V L1 10uH(0 OH) C7 104P C6 104P C110 104 1 2 KEY KEY R131 82K C131 5Pf PALET DIOT 1 2 3 D1 BAV99 3.6v RSSIT PDATAT PCLKT DCLKT MISO MOSI SCK RST C120 104 DVCC 3.6VD C32 1Kp C210 1Kp RXD Q3 A1126 Q8 A1162 Q9 A1162 Q6 A1126 Q4 A1162 Q5 A1162 BUZZER/+12V R11 56 OH R12 3.9K R17 3.9K R18 3.9K R15 3.9K R13 3.9K R14 3.9K R13.9K R2 3.9K Q1 C2712 Q2 C2712 RxD/P3.0 5 NC 6 TxD/P3.1 7 INT/P3.2 8 INT/P3.3 9 T0/P3.4 10 T1/P3.5 11 WR/P3.6 12 RD/P3.7 13 XTAL2 14 XTAL1 15 Vss 16 NC 17 P2.0/A8 18 P2.1/A9 19 P2.2/A10 20 P2.3/A11 21 P2.4/A12 22 P2.5/A13 23 P2.6/A14 24 P2.7/A15 25 PSEN 26 ALE/PROG 27 NC 28 EA/Vpp 29 P0.7/AD7 30 P0.6/AD6 31 P0.5/AD5 32 P0.4/AD4 33 P0.3/AD3 34 P0.2/AD2 35 P0.1/AD1 36 P0.0/AD0 37 Vcc 38 NC 39 P1.0/T2 40 P1.3 43 P1.4 44 P1.2 42 P1.1/T2EX 41 P1.5 1 P1.6 2 RESET 4 P1.7 3 U1 AT89S51/24AI R4 56 OH R556 OH R656 OH R7 56 OH R8 56 OH R9 56 OH R10 56 OH +5V +5V LED-1 LED-2 LED-3 LED-4 LED-5 LED-6 LED-7 LED-8 LED-14LED-10LED-9 LED-11 LED-15 C6 30p C5 30p XT1 14.318MHz RFDP4841 1 2 3 POWER R20 5R/1W C10 47uF/35V +12 +5 C1 104 +5 MCU Vin 1 GND 2 Vout 3 U2 7805 C2 100uF/6.3V C33 1Kp C31 1Kp C9 104 R16 3.9K R3 8.2k R19 3.9k Q7 A1162 U1-4 U1-4 +5V U1-5 U1-5 LED-13LED-12 a bf c g d e CH2 a bf c g d e CH3 dp CH6CH7CH4CH5 a bf c g d e CH1 f dp CH1 CH2 CH3 CH4CH5CH6 CH7 C4 10uF/6.3V 12345 6 78 9101112 1314 15 LED

Test Report

Produktsicherheit und –qualität Product Safety and Quality Prüfbericht - Nr.: Test Report No.: 16006196 001 Seite 2 von 15 Page 2 of 15 TEST SUMMARY 5.1 RADIATED EMISSION FOR FCC PART 15 PER SECTION 15.109(A) RESULT: ok 5.2 RADIATED EMISSION FOR FCC PART 15 PER SECTION 15.209(A) RESULT: ok 5.3 FUNDAMENTAL AND HARMONICS RADIATED EMISSION FOR FCC PART 15 PER SECTION 15.249(A) RESULT: ok Produktsicherheit und –qualität Product Safety and Quality Prüfbericht - Nr.: Test Report No.: 16006196 001 Seite 3 von 15 Page 3 of 15 Contents 1 GENERAL REMARKS........................................................................................................... 4 1.1 COMPLEMENTARY MATERIALS......................................................................................... 4 2 TEST SITES.......................................................................................................................... 4 2.1 T EST FACILITIES................................................................................................................ 4 2.2 LIST OF TEST AND MEASUREMENT INSTRUMENTS........................................................... 5 2.3 TRACE ABILITY................................................................................................................... 5 2.4 CALIBRATION..................................................................................................................... 5 2.5 MEASUREMENT UNCERTAINTY......................................................................................... 6 2.6 LOCATION OF ORIGINAL DATA........................................................................................... 6 2.7 S TATUS OF FACILITY USED FOR TESTING........................................................................... 6 3 GENERAL PRODUCT INFORMATION................................................................................... 6 3.1 PRODUCT FUNCTION AND INTENDED USE......................................................................... 7 3.2 R ATINGS AND SYSTEM DETAILS........................................................................................ 7 3.3 INDEPENDENT OPERATION MODES................................................................................... 7 3.4 S UBMITTED DOCUMENTS................................................................................................... 8 4 TEST SET-UP AND OPERATION MODE............................................................................... 8 4.1 P RINCIPLE OF CONFIGURATION SELECTION..................................................................... 8 4.2 TEST OPERATION AND TEST SOFTWARE........................................................................... 8 4.3 S PECIAL ACCESSORIES AND AUXILIARY EQUIPMENT...................................................... 8 4.4 COUNTERMEASURES TO ACHIEVE EMC COMPLIANCE.................................................... 8 4.5 TEST SET-UP........................................................................................................................ 9 5 TEST RESULTS E MI S S I ON..................................................................................... 10 5.1 RADIATED EMISSION FOR FCC PART 15 PER SECTION 15.109(A)................................. 10 5.2 RADIATED EMISSION FOR FCC PART 15 PER SECTION 15.209(A)................................. 11 5.3 F UNDAMENTAL AND HARMONICS RADIATED EMISSION FOR FCC PART 15 PER SECTION 15.249(A)....................................................................................................................................... 12 6 PHOTOGRAPHS OF THE TEST SET-UP.............................................................................. 13 7 L IST OF TABLES................................................................................................................ 15 8 LIST OF PHOTOGRAPHS.................................................................................................... 15 Produktsicherheit und –qualität Product Safety and Quality Prüfbericht - Nr.: Test Report No.: 16006196 001 Seite 4 von 15 Page 4 of 15 1 General Remarks 1.1 Complementary Materials All attachments are integral parts of this test report. This applies especially to the following appendix: Appendix 1: Test result 2 Test Sites 2.1 Test Facilities Shenzhen SMQ Shenzhen Bureau of Quality Technical Supervision Shenzhen Academy of Metrology and Quality Inspection Bldg, of Shenzhen Academy of Metrology and Quality Inspection Longzhu Road, Nanshan, Shenzhen, P.R. China Produktsicherheit und –qualität Product Safety and Quality Prüfbericht - Nr.: Test Report No.: 16006196 001 Seite 5 von 15 Page 5 of 15 2.2 List of Test and Measurement Instruments Table 1: List of Test and Measurement Equipment Kind of Equipment Manufacturer Type S/N Calibrated until BilogAntenna Chase CBL6112B 2591 29.01.2006 Horn Antenna Rohde & Schwarz HF906 100014 29.01.2006 3m Semi-anechoic chamber Albatross Projects 9X6X6 ---- 29.01.2006 EMI Test Receiver Rohde & Schwarz ESI26 838786/013 29.01.2006 Communications Test Set Rohde & Schwarz CMU200 1100.0008.02 29.01.2006 Communications Test Set HP HP8920A 3438A05187 29.01.2006 EMI Test Receiver Rohde & Schwarz ESCS30 100003 29.01.2006 AMN Rohde & Schwarz ESH3-Z5 100002 29.01.2006 2.3 Trace ability All measurement equipment calibrations are traceable to NIST or where calibration is performed outside the United States, to equivalent nationally recognized standards organizations 2.4 Calibration Equipment requiring calibration is calibrated periodically by the manufacturer or according to manufacturer’s specifications. Additionally all equipment is verified for proper performance on a regular basis using in house standards or comparisons. Produktsicherheit und –qualität Product Safety and Quality Prüfbericht - Nr.: Test Report No.: 16006196 001 Seite 6 von 15 Page 6 of 15 2.5 Measurement Uncertainty The estimated combined standard uncertainty for conducted emissions measurements is ± 3 dB.…

Text truncated - open the document above for the full version.

Test Setup Photos

Produktsicherheit und –qualität Product Safety and Quality Prüfbericht - Nr.: Test Report No.: 16006196 001 Seite 13 von 15 Page 13 of 15 6 Photographs of the Test Set-Up Photograph 1: Set-up for Radiation Measurement Below 1GHz Produktsicherheit und –qualität Product Safety and Quality Prüfbericht - Nr.: Test Report No.: 16006196 001 Seite 14 von 15 Page 14 of 15 Photograph 2: Set-up for Radiation Measurement Above 1GHz

Contact Information

Applicant

Wittman Lee(Project MGR)
[email protected]+8867563395166Fax: +8867563391399

Test Firm

Shenzhen Academy of Metrology & Quality InspectionPeter Lin
[email protected]86-755-6941635Fax: 86-755-6941615

Technical Specifications

#Rule PartsFrequency RangePower Output
115C915.11 MHz - 916.58 MHz-

Other Applications from COLIGEN Corp.

Parking sensor - FCC ID TFKRFDP8807 - COLIGEN Corp.
TFKRFDP8807

Parking sensor

Sep 11, 2006

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Parking sensor - FCC ID TFKRF001DTX - COLIGEN Corp.
TFKRF001DTX

Parking sensor

Sep 11, 2006

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Parking sensor - FCC ID TFKRFDP4852 - COLIGEN Corp.
TFKRFDP4852

Parking sensor

Sep 11, 2006

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Parking Sensor Controller - FCC ID TFKFWO48R41 - COLIGEN Corp.
TFKFWO48R41

Parking Sensor Controller

Jan 10, 2006

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified