FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Giesecke-Devrient Mobile Security GmbH/
  3. TIJ-BTM31

TIJ-BTM31USB Electronic Key

Giesecke-Devrient Mobile Security GmbH
USB Electronic Key - FCC ID TIJ-BTM31 - Giesecke-Devrient Mobile Security GmbH
Click to zoom

Application Details

Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Date of Grant
Nov 08, 2007
Application Purpose
Original Equipment
Date of Application
Nov 08, 2007
Equipment Note
USB Electronic Key
Company
Giesecke-Devrient Mobile Security GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

StarSign ® Bio Token 3.1 M USB Token Reference Manual Edition 07.2007 ID No. 30023721 © Copyright 2007 by Giesecke & Devrient GmbH Prinzregentenstr. 159 Postfach 80 07 29 D-81607 München This document as well as the information or material contained is copyrighted. Any use not explicitly per- mitted by copyright law requires prior consent of Giesecke & Devrient GmbH. This applies to any repro- duction, revision, translation, storage on microfilm as well as its import and processing in electronical systems, in particular. Subject to technical changes. StarSign ® Bio Token is a registered trademark of Giesecke & Devrient GmbH. © Copyright 2007 by Giesecke & Devrient GmbH - Germany – Prinzregentenstr. 159, P.O. Box 80 07 29, D-81607 München © 2007 Giesecke & Devrient GmbH. All rights reserved The names of the other products mentioned are trademarks of their respective owners. This hardware key is in compliance with the following test specification: CEI EN 61000-4-2; CEI EN 61000-4-3; CISPR22 as required by: CEI EN 61000-6-1, CEI EN 61000-6-2, CEI EN 61000-6-3, CEI EN 61000-6-4 which are specified for the following test: • “ESD Immunity test” • “Radiated radio-frequency and electromagnetic field immunity test” • “Radiated Emission Verification” In compliance with the “Essential Requisites” for the EMC Directives 89/336/EEC & 2004/108/EEC. FCC ID: TIJ-BTM31 Giesecke & Devrient GmbH StarSign® Bio Token 3.1 Supply: 5V DC Absorption: 250 mA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Caution: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. IMPORTANT REMARKS Due to the limited space o n the product shell, all FCC certification references are on this technical manual Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Contents Reference Manual StarSign Bio Token 3.1 M/Edition 07.2007 ID No. 30023721 Contents About StarSign Bio Token 3.1 M .......................................................................................... 1 About the Document ........................................................................................................... 2 1Basics3 1.1General Introduction to Biometrics............................................................................. 4 1.2Biometrics, Smart Cards and Tokens .......................................................................... 5 1.3LED Status ................................................................................................................. 6 2 Commands9 2.1ENROLL FINGERPRINT............................................................................................... 10 2.2VERIFY FINGERPRINT ................................................................................................ 12 2.3VERSION INFO.......................................................................................................... 14 Appendix15 AOverview of Status Bytes.......................................................................................... 16 BTechnical Specifications............................................................................................ 18 CReference Literature................................................................................................. 19 DGlossary................................................................................................................... 20 Index ............................................................................................................................... 23 Contents Reference Manual StarSign Bio Token 3.1 M/Edition 07.2007 ID No. 30023721 About StarSign Bio Token 3.1 M Reference Manual StarSign Bio Token 3.1 M/Edition 07.2007 1 of 23 ID No. 30023721 About StarSign Bio Token 3.1 M Characteristics StarSign Bio Token 3.1 M is a USB-PKI token based on the STARCOS 3.0 operating system. The token comprises a fingerprint sensor and on-to- ken fingerprint verification functionality. The biometric data never leaves the token. StarSign Bio Token 3.1 M is supported by StarSign middleware and can therefore be used for all public key applications supporting MS CAPI (CSP) or PKCS#11. Fingerprint verification can be used instead of – or in addition to – PIN verification, granting a higher user convenience and a real tie between user and token. This is particularly of interest in applications that require non-repudiation. StarSign Bio Token 3.1 M also comprises an independent flash drive. Features StarSign Bio Token 3.1 M features: – Based on STARCOS 3.0 operating system – On-toke…

Text truncated - open the document above for the full version.

External Photos

EXTERNAL PHOTOGRAPH FRONT WIEV EXTERNAL PHOTOGRAPH REAR WIEV

ID Label/Location Info

WHERE ARE THE LABELS Real Manufacturer & Product Name Label Label Place (this label is demonstrative only)

Internal Photos

INTERNAL PHOTOGRAPH BIOTOKEN M TOP INTERNAL PHOTOGRAPH BIOTOKEN M BOTTOM

Test Report

FCC.TR. TEST REPORT 07.581 Prima Ricerca & SviluppoSrl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309 Edition: 1.0 Issue date: 14/05/2007 sheet 1 of 20 EQUIPMENT UNDER TEST : APPARECCHIO IN PROVA : USB ELECTRONIC KEY MODEL: STARSIGN BIO TOKEN 3.1 M REFERENCE STANDARDS : NORME DI RIFERIMENTO : FCC 47 CFR Part 15 CUSTOMER: RICHIEDENTE: • Dept. / Firm : Ente / Società’: GIESECKE & DEVRIENT GMBH • Mr.: Sig.: Walter Hinz • Address: Indirizzo: PRINZREGENTENSTRASSE 159 – 81677 MUNCHEN – GERMANY • Tel. : Telefono : ++49 89 4119-1906 • Telefax Fax : ++49 89 4119-1905 • E-mail: e-mail [email protected] Site of test execution: Via Campagna, 92 - 22020 Gaggino Faloppio (CO) LocalitĂ  esecuzione prove: Date of test samples receipt: 14/05/2007 Date of start test: 14/05/2007 Data ricevimento campioni: Data inizio prove: Date of end test: 14/05/2007 Data fine prove: Witness to the test: Presenti alle prove: Signature of the engineers: Firma esecutore prove: Approved by: Approvato da: Sig. Gianluca Maffioli Sig. Nicola Albergati ......................................................... .......................................................... Massimo Maltempi ......................................................... G. Molteni The test results recorded in this Test Report are exclusively referred to the tested samples. I risultati del presente rapporto di prova si riferiscono esclusivamente al campione sottoposto a prova. Reproduction of this EMC-Test Report in whole or in part is prohibited without the written authorization of the Laboratory Director La riproduzione di questo Rapporto in modo parziale o totale è PROIBITO senza l’autorizzazione scritta della Direzione del Laboratorio FCC.TR. TEST REPORT 07.581 Prima Ricerca & SviluppoSrl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309 Edition: 1.0 Issue date: 14/05/2007 sheet 2 of 20 0. CONTENTS Page Rev Date 0. CONTENTS .............................................................................................. 2 1. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT) ..... 3 1.1 Identification ...................................................................................... 3 1.2 Technical data ................................................................................... 3 1.3 Modifications incorporated in E.U.T................................................... 3 1.4 Derived models.................................................................................. 4 1.5 Auxiliary equipment........................................................................... 5 2. TEST CONDITIONS ................................................................................. 6 2.1 Operating test modes and test conditions......................................... 6 2.2 Test overview .................................................................................... 6 3. REFERENCE STANDARD FOR PERFORMED TESTS .......................... 7 4. Summary of test results ............................................................................ 8 4.1 Emission tests ................................................................................... 8 5. TEST RESULTS ....................................................................................... 9 6. EUT TECHNICAL DOCUMENTATION................................................... 17 6.1 Wiring diagrams............................................................................... 17 6.2 Technical manual .....................Errore. Il segnalibro non è definito. 6.3 Photographic documentation ........................................................... 18 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 14/05/07 14/05/07 14/05/07 14/05/07 14/05/07 14/05/07 14/05/07 14/05/07 14/05/07 14/05/07 14/05/07 14/05/07 14/05/07 14/05/07 14/05/07 14/05/07 14/05/07 14/05/07 FCC.TR. TEST REPORT 07.581 Prima Ricerca & SviluppoSrl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309 Edition: 1.0 Issue date: 14/05/2007 sheet 3 of 20 1. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT) 1.1 Identification Brand name: GIESECKE & DEVRIENT GmbH Manufacturer: EUTRONSEC S.P.A. Equipment : USB KEY Model name or No. : STARSIGN BIO TOKEN 3.1 M Serial number : Not present FCC ID : TIJ-BTM31 Country of manufacturer: ITALY 1.2 Technical data FCC class: Unintentional radiators, Class B Supply voltage: +5 V dc supplied by USB PC connector Input Power / Current : 250 mA max. Maximum internal frequency generated by EUT Oscillator: 24 MHz; Data Exchange Rate:480Mbit/s Typical usage : Document encrypting and storing EUT single or system: Single EUT dimensions : 8,4 x 4,0 x 1,7 cm 1.3 Modifications incorporated in E.U.T. The following items are the modifications introduced in the equipment under test : • None FCC.TR. TEST REPORT 07.581 Prima Ricerca & SviluppoSrl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309 Edition: 1.0 Issue date: 14/05/2007 sheet 4 of 20 1.4 Derived models On each product it is also possible to mount one…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Alexander Summerer(Director Product Management)
[email protected]49-89-4119-2418Fax: 49-89-4119-781510

Test Firm

Prima Ricerca & Sviluppo S.r.l.Enrico Banfi
[email protected]39-031-3500011Fax: 39-031-991309

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from Giesecke-Devrient Mobile Security GmbH

USB Electronic Key - FCC ID TIJ-BT31 - Giesecke-Devrient Mobile Security GmbH
TIJ-BT31

USB Electronic Key

Nov 08, 2007

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
StarSign Bio Token 3.0 M - FCC ID TIJ-BIOTOKEN-M - Giesecke-Devrient Mobile Security GmbH
TIJ-BIOTOKEN-M

StarSign Bio Token 3.0 M

Dec 22, 2005

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
StarSign Bio Token - FCC ID TIJ-BIOTOKEN - Giesecke-Devrient Mobile Security GmbH
TIJ-BIOTOKEN

StarSign Bio Token

Dec 06, 2005

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral