Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Ruoey Lung Enterprise Corp. NO.17, LU-KUNG SOUTH 2 ROAD,CHANG-PIN INDUSTRIAL PARK LU-KANG CHANGHUA TAIWAN, R.O.C. TEL:04-781-0208 FAX:04-781-0209 Federal Communications Commission FCC ID: TRURC-N3-16 Product Name: Remote control Model Name: RC-N3-16+1, RC-N3-16, RC-N2-16+1, RC-N2-16 (RC-WP-100), RC-N1-10+1, RC-N1-10 (RC-NP-100), RC-N1-05+1, RC-N1-05 (RC-NP-100) Trade Name: OKO Dear Sir: In accordance with 47 C.F.R. Section 0.459, we would like to request confidentiality on some exhibits we submitted for above application for the reason of trade secret. If those exhibits are available for public inspection, any person who once gets the information contained in those exhibits will be able to design and to make the same products very easily. This is a very serious problem and huge loss for us, because we did invest so much on it. Please be not made the Exhibit Types listed below routinely available for public inspection: Block Diagram and Schematics. By: Sophia Yang By: Title : Business manager Applicant : Ruoey Lung Enterprise Corp. Address : No.17,Lu-kung south 2 Road.Chang-Pin, Industrial park lu-kang, changhua, Taiwan, R.O.C
http://mail.google.com/mail/?view=page&name=gp&ver=sh3fib53pgpk Ruoey Lung Enterprise Corp., FCC ID: TRURC-N3-16, Assessment NO.: AN07T6907, Notice#2 Inbox Reply from "[email protected]" <[email protected]> hide details Jun 18 (2 days ago) to [email protected] cc [email protected], [email protected] date Jun 18, 2007 10:04 PM subject Ruoey Lung Enterprise Corp., FCC ID: TRURC-N3-16, Assessment NO.: AN07T6907, Notice#2 Dear S.S., The review is complete. There is only one small item. 1. The bandwidth plot shows a measured bandwidth of 50 kHz but on test report sheet 18 of 21, the value listed is 128 kHz. In both cases, the limit is met so there is no compliance issue, but please confirm which one is correct. If the 128 kHz is correct, please revise the report with a new plot. If the 50 kHz is correct, your email statement will be sufficient. Best regards, Tim Dwyer CCS TCB Reviewer The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information within 30 days of the original e-mail date may result in application dismissal and forfeiture of the filing fee. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the e-mail address listed below the name of the sender. Reply Reply to all Forward Invite [email protected] to Gmail Reply from Iris Lin <[email protected]> hide details 8:42 pm (1 hour ago) to [email protected], [email protected] cc Mike Kuo <[email protected]> date Jun 20, 2007 8:42 PM subject Re: Ruoey Lung Enterprise Corp., FCC ID: TRURC-N3-16, Assessment NO.: AN07T6907, Notice#2 Dear Tim, Please refer to the updated report as attachment for your reference. Would you please help us to issue the grant today? Your response will be appreciated. ELECTRONICS TESTING CENTER, TAIWAN IRIS LIN () TEL: 886-2-26023052 ext.10 FAX: 886-2-26010910 ----- Original Message ----- From: < [email protected]> To: < [email protected]> Cc: < [email protected]>; <[email protected]> Sent: Tuesday, June 19, 2007 10:04 AM Subject: Ruoey Lung Enterprise Corp., FCC ID: TRURC-N3-16, Assessment NO.: AN07T6907, Notice#2 > Dear S.S., > > The review is complete. There is only one small item. > > 1. The bandwidth plot shows a measured bandwidth of 50 kHz but on test report sheet 18 of 21, the value listed is 128 kHz. In both cases, the limit is met so there is no compliance issue, but please confirm which one is correct. If the 128 kHz is correct, please revise the report with a new http://mail.google.com/mail/?view=page&name=gp&ver=sh3fib53pgpk (1 of 2)6/20/2007 10:32:10 PM http://mail.google.com/mail/?view=page&name=gp&ver=sh3fib53pgpk plot. If the 50 kHz is correct, your email statement will be sufficient. Question #2: The FCC ID label format, Form 731, and request for confidentiality letter all show FCC ID: TRURC-N3-16. But the test report as well as all photo exhibits all show a different FCC ID: TRURC-N123. Please clarify and resubmit relevant exhibits. - Show quoted text - Exhibit-C-Test-Report-REV.pdf 223K View as HTML Download http://mail.google.com/mail/?view=page&name=gp&ver=sh3fib53pgpk (2 of 2)6/20/2007 10:32:10 PM
ETC Report No.:07-04-RBF-110 FCC ID.: TRURC-N123 Rev. No 1.0 CONSTRUCTED PHOTOS of EUT Model: RC-N3-16+1 Front View of EUT Rear View of EUT ETC Report No.:07-04-RBF-110 FCC ID.: TRURC-N123 Rev. No 1.0 CONSTRUCTED PHOTOS of EUT Model: RC-N3-16+1 Side View of EUT Side View of EUT ETC Report No.:07-04-RBF-110 FCC ID.: TRURC-N123 Rev. No 1.0 CONSTRUCTED PHOTOS of EUT Model: RC-N3-16+1 Top View of EUT Bottom View of EUT
LABELβS LOCATION 29mm 20mm
ETC Report No.:07-04-RBF-110 FCC ID.: TRURC-N123 Rev. No 1.0 CONSTRUCTED PHOTOS of EUT Model: RC-N3-16+1 Internal View of EUT ETC Report No.:07-04-RBF-110 FCC ID.: TRURC-N123 Rev. No 1.0 CONSTRUCTED PHOTOS of EUT Model: RC-N3-16+1 Component View of Main PCB Solder View of Main PCB
RF Specification 1. Rating DC 3 V, 5 mA 2. Frequency Band UHF Carrier Frequency 433.92 MHz 3. Modulation Type ASK 4. Duty Cycle 50 % 5. Bit Rate of Transmission 1000bps 6. Antenna gain < 0 dBi
Rev. No 1.0 FCC Part 15 EMI TEST REPORT of E.U.T. : Remote Control FCC ID. : TRURC-N3-16 Model : RC-N3-16+1 Working Frequency : 433.92MHz for APPLICANT : Ruoey Lung Enterprise Corp. ADDRESS : No.17,Lu-kung south 2 Road.Chang-Pin, Industrial park lu-kang, changhua, Taiwan, R.O.C Test Performed by ELECTRONICS TESTING CENTER, TAIWAN NO. 34, LIN 5, DING FU TSUN, LINKOU HSIANG TAIPEI HSIEN, TAIWAN, R.O.C. Tel : (02)26023052 Fax : (02)26010910 http://www.etc.org.tw ; e-mail: [email protected] Report Number : 07-04-RBF-110 ETC Report No.:07-04-RBF-110 FCC ID.: TRURC-N3-16 Rev. No 1.0 TEST REPORT CERTIFICATION Applicant : Ruoey Lung Enterprise Corp. No.17,Lu-kung south 2 Road.Chang-Pin, Industrial park lu-kang, changhua, Taiwan, R.O.C Manufacture : Ruoey Lung Enterprise Corp. No.17,Lu-kung south 2 Road.Chang-Pin, Industrial park lu-kang, changhua, Taiwan, R.O.C Description of EUT : a) Type of EUT : Remote control b) Trade Name : OKO c) Model No. : RC-N3-16+1 d) Serial Model No. : RC-N3-16, RC-N2-16+1, RC-N2-16, RC-N1-10+1, RC-N1-10, RC-N1-05+1, RC-N1-05 e) FCC ID : TRURC-N3-16 f) Working Frequency : 433.92 MHz g) Power Supply : DC Battery 1.5V*2 Regulation Applied : FCC Rules and Regulations Part 15 Subpart C (2006) I HEREBY CERTIFY THAT; The data shown in this report were made in accordance with the procedures given in ANSI C63.4 and the energy emitted by the device was founded to be within the limits applicable. I assume full responsibility for accuracy and completeness of these data. Note : 1. The results of the testing report relate only to the items tested. 2. The testing report shall not be reproduced except in full, without the written approval of ETC. Date Test Item Received : Apr. 25, 2007 Date Test Campaign Completed : May. 03, 2007 Date of Issue : May. 23, 2007 Test Engineer : ( Max Wu ) Approve & Authorized : Will Yauo, Manager EMC Dept. II of ELECTRONICS TESTING CENTER, TAIWAN ETC Report No.:07-04-RBF-110 FCC ID.: TRURC-N3-16 Rev. No 1.0 Table of Contents Page 1. GENERAL INFORMATION.....................................................................................................................................................1 1.1 PRODUCT DESCRIPTION...........................................................................................................................................................1 1.2 CHARACTERISTICS OF DEVICE:................................................................................................................................................1 1.3 TEST METHODOLOGY...............................................................................................................................................................1 1.4 TEST FACILITY...........................................................................................................................................................................1 2. DEFINITION AND LIMITS......................................................................................................................................................2 2.1 DEFINITION.................................................................................................................................................................................2 2.2 RESTRICTED BANDS OF OPERATION......................................................................................................................................2 2.3 LIMITATION................................................................................................................................................................................2 2.4 LABELING REQUIREMENT........................................................................................................................................................4 2.5 USER INFORMATION..................................................................................................................................................................4 3 SYSTEM TEST CONFIGURATION........................................................................................................................................5 3.1 JUSTIFICATION...........................................................................................................................................................................5 3.2 DEVICES FOR TESTED SYSTEM................................................................................................................................................5 4. RADIATED EMISSION MEASUREMENT............................................................................................................................6 4.1 APPLICABLE STANDARD.........................................................................................................................................................6 4.2 MEASUREMENT PROCEDURE...................................................................................................................................................6 4.3 TEST DATA.................................................................................................................................................................................8 4.4 FIELD STRENGTH CALCULATION.........................................................................................................................................10 4.5 ACTIVATE TIME......................................................................................................................................................................10 4.6 CALCULATION OF DUTY FACTOR........................................................................................................................................10 4.7 RADIATED TEST EQUIPMENT...............................................................................................................................................16 4.8 MEASURING INSTRUMENT SETUP...................................................β¦
Text truncated - open the document above for the full version.
ETC Report No.:07-04-RBF-110 FCC ID.: TRURC-N123 Rev. No 1.0 4.9 Radiated Measurement Photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.74 MHz - 433.74 MHz | - |

Remote Controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Controller
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
REMOTE CONTROL
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote control
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter