Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Federal Communication Commission Interference Statement (FCC ID: TV7R5SHPN) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: ● Reorient or relocate the receiving antenna. ● Increase the separation between the equipment and receiver. ● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ● Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device and its antenna must not be co-located or operation in conjunction with any other antenna or transmitter. IMPORTANT: Exposure to Radio Frequency Radiation. 157 cm minimum distance has to be maintained between the antenna and the occupational user and 350 cm to general public. Under such configuration, the FCC radiation exposure limits set forth for an population/uncontrolled environment can be satisfied. List of approved antennas: ●Omni Directional, MT-482016NA, 9 dBi; ●Panel, PA 58-24, 24 dBi; ●Dish, HDDA 5W-32-DP2, 32 dBi ; Antennas of same type and lower gain than those listed above may be used in compliance with certification. Antenna Installation. WARNING: It is installer's responsibility to ensure that when using the authorized antennas in the United States (or where FCC rules apply); only those antennas certified with the product are used. The use of any antenna other than those certified with the product is expressly forbidden in accordance to FCC rules CFR47 part 15.204. The installer should configure the output power level of antennas, according to country regulations and per antenna type. Professional installation is required of equipment with connectors to ensure compliance with health and safety issues.
SIA "Mikrotīkls" Aizkraukles iela 23, Rīga, LV-1006, Latvia Phone: +371 67317700 Fax: +371 67317701 September 4, 2008 Federal Communications Commission Equipment Approval Services Post Office Box 358315 Pittsburgh, Pennsylvania 15215-5315 To Whom It May Concern: Please be advised that SIA "Mikrotikls" has authorized Scot Rogers of Rogers Labs, Inc. to act on behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters and submittals. All acts carried out by Rogers Labs, Inc. on our behalf shall have the same effects as our own. Rogers Labs, Inc. is authorized to receive and exchange data between our company and the Commission. This Authorization is made pursuant to Paragraph 2.911 of FCC Rules CFR 47. This Authorization is in effect until otherwise notified in writing. Āris Jurkāns engineer, R&D SIA "Mikrotikls"
September 26, 2011 Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Office of Engineering and Technology Federal Communications Commission Columbia, MD 21046 Applicant: Mikrotikls SIA Pernavas 46 Riga, Latvia LV-1009 Re: Confidentiality for submittal information regarding FCC ID number TV7R5SHPN PRODUCT: Broadband Digital Transmission System operating under CFR47 part 15.247 Dear Sirs: Mikrotikls SIA requests that the material in the Schematic, block diagram, and Operational Description is withheld from public disclosure in accordance with Section 0.459 of the Commission’s Rules, 47 C.F.R., following grant of the application. In support of this request, Mikrotikls submits the following: Long Term Confidential Files Include Schematics File Name Conf Schem R5SHPn.pdf Block diagram File Name Conf BlkDia R5SHPn.pdf Operational Description File Name Conf OpDes R5SHPn.pdf 1. Identification of the specific information for which confidential treatment is sought: The materials set forth in the Operational Description, block diagram, and Schematics, which are segregated from the non-confidential exhibits of the application, are those for which confidentiality is sought. 2. Identification of the Commission proceeding in which the information was submitted or a description of the circumstances giving rise to the submission: The proceeding is that involving the application for equipment authorization (certification) under FCC ID No: TV7R5SHPN 3. Explanation of the degree to which the information is commercial or financial, or contains a trade secret or is privileged: This material includes a detailed theory of operation, circuit diagrams, (schematic diagrams) and any detail Parts List. As such, this material is treated as highly confidential business information. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 4. Explanation of the degree to which the information concerns a service that is subject to competition: The material for which confidentiality is sought is employed in the design and manufacture of this transmitting equipment that is offered on a highly competitive basis. Customers for this equipment have a variety of competing sources. 5. Explanation of how disclosure of the information could result in substantial competitive harm: Disclosure would, in effect, give away the fruits of the labors of Mikrotik engineering personnel, who have designed the equipment and the manufacturing process. Disclosure would also offer competitors additional unwarranted insight into the state of the product development, thereby allowing competitors an advantage, not available to Mikrotikls SIA 6. Identification of any measures taken by the submitting party to prevent unauthorized disclosure: The information for which confidential treatment is sought is kept confidential by Mikrotikls SIA and not made available to third parties except pursuant to non-disclosure agreements. 7. Identification of whether the information is available to the public and the extent of any previous disclosure of the information to third parties: To the knowledge of those preparing this application, the information has not been disclosed publicly heretofore. While the general theory of operation of this equipment has been the subject of numerous disclosures in industry and standards groups as well as in rule making proceedings of the FCC, the protection sought is narrowly drawn and pertains to certain specific implementations of this radio technology. 8. Justification of the period during which the submitting party asserts that the material should not be available for public disclosure: This material should not be disclosed for at least 25 years. While improvements in design are made relatively frequently, disclosure of the design information would lead to insights into both design and manufacturing techniques that could have an adverse competitive effect for many years to come. As such, it is important that the design not be made available to unauthorized persons who might attempt to use knowledge of the design to compromise the applications for which the equipment will be employed. Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers
Mikrotikls SIA 46 Pernavas str., Riga LV-1009, LATVIA Tel: +371 6 7317700Fax:+371 6 7317701 DoC Attestation Letter Date:2011/9/23 We Mikrotikls SIA, as the grantee of this project FCC ID:TV7R5SHPN, would like to declare that the composite portion catagorized as computer peripheral has been authorized under the Declaration of Conformity procedures. Regards, FCC Grantee contract person information. Applicant's company name : Mikrotikls SIA Applicant's company address : 46 Pernavas str., Riga LV-1009, LATVIA Signature : Job Tittle and Dept. : Zvegincevs Edmunds / Engineer, R&D E-Mail : [email protected] Tel. : +371 6 7317700
September 26, 2011 Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Federal Communications Commission Equipment Approval Services P.O. Box 35815 Pittsburgh, PA 15251-3315 Applicant: Mikrotikls SIA Pernavas 46 Riga, Latvia LV-1009 Equipment: FCC ID: TV7R5SHPN FCC Rules: Part 15.247 Digital Transmission System approval Men: The form 731 and application have been electronically submitted and any attachments will be up loaded to your site to be used in obtaining grant of certification. Permanent Mikrotikls SIA requests that the material in the following files be withheld from public disclosure in accordance with Section 0.459 of the Commission’s Rules, 47 C.F.R. 0.459, following grant of the application. Schematics File Name Conf Schem R5SHPn.pdf Block diagram File Name Conf BlkDia R5SHPn.pdf Operational Description File Name Conf OpDes R5SHPn.pdf Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers Rogers Labs, Inc. Enclosures ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214
Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: ExtPho R5SHPn Page 1 of 2 External photographs of equipment under test Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: ExtPho R5SHPn Page 2 of 2
Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: LabelSmpl R5SHPn Page 1 of 1 Label and Placement
Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: IntPho R5SHPn Page 1 of 4 Internal photographs of equipment under test Internal photographs of equipment under test (inside enclosure) Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: IntPho R5SHPn Page 2 of 4 Bottom side of supporting circuit board EUT PCB (heat sink in place) Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: IntPho R5SHPn Page 3 of 4 Heat sink removed top side Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: IntPho R5SHPn Page 4 of 4 Heat sink removed bottom side Shield removed for photograph
Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: RFExp R5SHPn Page 1 of 1
NVLAP Lab Code 200087-0 Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: Mikrotikls R5SHPn 110826M TstRpt Page 1 of 54 SUBMITTAL APPLICATION REPORT FOR GRANT OF CERTIFICATION FOR Model: R5SHPn 5740-5830 MHz MIMO Broadband Digital Transmission System FCC ID: TV7R5SHPN FOR MIKROTIKLS SIA Pernavas 46 Riga, Latvia LV-1009 Test Report Number: 110826M Authorized Signatory: Scot D. Rogers NVLAP Lab Code 200087-0 Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: Mikrotikls R5SHPn 110826M TstRpt Page 2 of 54 Engineering Test Report For Grant of Certification Application FOR CFR 47, PART 15C - Intentional Radiators CFR 47 Paragraph 15.247 License Exempt Intentional Radiator For MIKROTIKLS SIA Pernavas 46 Riga, Latvia LV-1009 Broadband Digital Transmission System Model: R5SHPn Frequency Range 5740-5830 MHz FCC ID#: TV7R5SHPN Test Date: August 26, 2011 Certifying Engineer: Scot D. Rogers Rogers Labs, Inc. 4405 West 259 th Terrace Louisburg, KS 66053 Telephone/Facsimile: (913) 837-3214 This report shall not be reproduced except in full, without the written approval of the laboratory. This report must not be used by the client to claim product endorsement by NVLAP, NIST, or any agency of the U.S. Government. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214 NVLAP Lab Code 200087-0 Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: Mikrotikls R5SHPn 110826M TstRpt Page 3 of 54 Table Of Contents TABLE OF CONTENTS .................................................................................................. 3 FORWARD ..................................................................................................................... 6 OPINION / INTERPRETATION OF RESULTS ............................................................... 6 ENVIRONMENTAL CONDITIONS.................................................................................. 6 EQUIPMENT TESTED .................................................................................................... 6 APPLICATION FOR CERTIFICATION ........................................................................... 7 APPLICABLE STANDARDS & TEST PROCEDURES .................................................. 8 EQUIPMENT FUNCTION AND CONFIGURATION ........................................................ 8 Equipment Configuration.................................................................................................................................... 9 TEST SITE LOCATIONS ................................................................................................ 9 UNITS OF MEASUREMENTS ........................................................................................ 9 TEST PROCEDURES ................................................................................................... 10 AC Line Conducted Emission Test Procedure ................................................................................................ 10 Radiated Emission Test Procedure ................................................................................................................... 10 LIST OF TEST EQUIPMENT ........................................................................................ 11 INTENTIONAL RADIATORS ........................................................................................ 12 Antenna Requirements ...................................................................................................................................... 12 Restricted Bands of Operation .......................................................................................................................... 12 General Radiated Emissions in Restricted Bands Data (all configurations) ...................................................... 12 Harmonic Radiated Emissions in Restricted Bands Data (2dBi Dipole) ........................................................... 13 Harmonic Radiated Emissions in Restricted Bands Data (9dBi Omni) ............................................................. 13 Harmonic Radiated Emissions in Restricted Bands Data (24dBi Panel) ........................................................... 13 Harmonic Radiated Emissions in Restricted Bands Data (32dBi Dish) ............................................................ 14 Summary of Results for Radiated Emissions in Restricted Bands ................................................................ 14 AC Line Conducted Emissions Procedure ....................................................................................................... 15 Figure One AC Line Conducted Emissions Line 1............................................................................................ 16 NVLAP Lab Code 200087-0 Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: Mikrotikls R5SHPn 110826M TstRpt Page 4 of 54 Figure Two AC Line Conducted Emissions Line 2 ........................................................................................... 16 AC Line Conducted Emissions Data (Highest Emissions) ................................................................................ 17 Summary of Results for AC Line Conducted Emissions ................................................................................ 18 Gene…
Text truncated - open the document above for the full version.
Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: TSup R5SHPn Page 1 of 4 Test setup photographs AC Line Conducted Emissions Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: TSup R5SHPn Page 2 of 4 Radiated Emissions Omni Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: TSup R5SHPn Page 3 of 4 Panel Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: R5SHPn SN: 2B7301BF7D81 Louisburg, KS 66053 Test #: 110826M FCC ID#: TV7R5SHPN Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 26, 2011 Revision 1 File: TSup R5SHPn Page 4 of 4 Dish
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 3 | 15C | 5.75 GHz - 5.82 GHz | 743.00 mW |
hAP be lite
Equipment Class
NII - Unlicensed National Information Infrastructure TXMA53UG+HbeH
Equipment Class
6ID - 15E 6 GHz Low Power Indoor Access PointTG-LR92
Equipment Class
DTS - Digital Transmission SystemwAP ax
Equipment Class
JAB - Part 15 Class B Digital Device
R11e-LR2
Equipment Class
DTS - Digital Transmission System