FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Mikrotikls SIA/
  3. TV7RB751-2HND

TV7RB751-2HND2X2 MIMO 802.11B/G/N DIGITAL TRANSMISSION SYSTEM ROUTER

Mikrotikls SIA
2X2 MIMO 802.11B/G/N DIGITAL TRANSMISSION SYSTEM ROUTER - FCC ID TV7RB751-2HND - Mikrotikls SIA
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 05, 2011
Application Purpose
Original Equipment
Date of Application
Sep 05, 2011
Equipment Note
2X2 MIMO 802.11B/G/N DIGITAL TRANSMISSION SYSTEM ROUTER
Frequency Range
2422.00000000 - 2452.00000000
Company
Mikrotikls SIA
Country
Latvia

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

August 29, 2011 Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Office of Engineering and Technology Federal Communications Commission Columbia, MD 21046 Applicant: Mikrotikls SIA Pernavas 46 Riga, Latvia LV-1009 Re: Confidentiality for submittal information regarding FCC ID number TV7RB751-2HND PRODUCT: 2x2 MIMO 802.11 b/g/n Broadband Digital Transmission System operating under CFR47 part 15.247 Dear Sirs: Mikrotikls SIA requests that the material in the Schematic, block diagram, and Operational Description is withheld from public disclosure in accordance with Sections0.457 and 0.459 of the Commission’s Rules, 47 C.F.R., following grant of the application. In support of this request, Mikrotikls submits the following: Long Term Confidential Files Include Schematics File Name Conf Schem RB751U2HND.pdf Block diagram File Name Conf BlkDia RB751U2HND.pdf Operational Description File Name Conf OpDes RB751U2HND.pdf 1. Identification of the specific information for which confidential treatment is sought: The materials set forth in the Operational Description, block diagram, and Schematics, which are segregated from the non-confidential exhibits of the application, are those for which confidentiality is sought. 2. Identification of the Commission proceeding in which the information was submitted or a description of the circumstances giving rise to the submission: The proceeding is that involving the application for equipment authorization (certification) under FCC ID No: TV7RB751-2HND 3. Explanation of the degree to which the information is commercial or financial, or contains a trade secret or is privileged: ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 This material includes a detailed theory of operation, circuit diagrams, (schematic diagrams) and any detail Parts List. As such, this material is treated as highly confidential business information. 4. Explanation of the degree to which the information concerns a service that is subject to competition: The material for which confidentiality is sought is employed in the design and manufacture of this transmitting equipment that is offered on a highly competitive basis. Customers for this equipment have a variety of competing sources. 5. Explanation of how disclosure of the information could result in substantial competitive harm: Disclosure would, in effect, give away the fruits of the labors of Mikrotik engineering personnel, who have designed the equipment and the manufacturing process. Disclosure would also offer competitors additional unwarranted insight into the state of the product development, thereby allowing competitors an advantage, not available to Mikrotikls SIA 6. Identification of any measures taken by the submitting party to prevent unauthorized disclosure: The information for which confidential treatment is sought is kept confidential by Mikrotikls SIA and not made available to third parties except pursuant to non-disclosure agreements. 7. Identification of whether the information is available to the public and the extent of any previous disclosure of the information to third parties: To the knowledge of those preparing this application, the information has not been disclosed publicly heretofore. While the general theory of operation of this equipment has been the subject of numerous disclosures in industry and standards groups as well as in rule making proceedings of the FCC, the protection sought is narrowly drawn and pertains to certain specific implementations of this radio technology. 8. Justification of the period during which the submitting party asserts that the material should not be available for public disclosure: This material should not be disclosed for at least 25 years. While improvements in design are made relatively frequently, disclosure of the design information would lead to insights into both design and manufacturing techniques that could have an adverse competitive effect for many years to come. As such, it is important that the design not be made available to unauthorized persons who might attempt to use knowledge of the design to compromise the applications for which the equipment will be employed. Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers

Cover Letter(s)

SIA "Mikrotīkls" Aizkraukles iela 23, Rīga, LV-1006, Latvia Phone: +371 67317700 Fax: +371 67317701 September 4, 2008 Federal Communications Commission Equipment Approval Services Post Office Box 358315 Pittsburgh, Pennsylvania 15215-5315 To Whom It May Concern: Please be advised that SIA "Mikrotikls" has authorized Scot Rogers of Rogers Labs, Inc. to act on behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters and submittals. All acts carried out by Rogers Labs, Inc. on our behalf shall have the same effects as our own. Rogers Labs, Inc. is authorized to receive and exchange data between our company and the Commission. This Authorization is made pursuant to Paragraph 2.911 of FCC Rules CFR 47. This Authorization is in effect until otherwise notified in writing. Āris Jurkāns engineer, R&D SIA "Mikrotikls"

Cover Letter(s)

Mikrotikls SIA 46 Pernavas str., Riga LV-1009, LATVIA Tel: +371 6 7317700Fax:+371 6 7317701 DoC Attestation Letter Date:2011/8/19 We Mikrotikls SIA, as the grantee of this project FCC ID:TV7RB751-2HND, would like to declare that the composite portion catagorized as computer peripheral has been authorized under the Declaration of Conformity procedures. Regards, FCC Grantee contract person information. Applicant's company name : Mikrotikls SIA Applicant's company address : 46 Pernavas str., Riga LV-1009, LATVIA Signature : Job Tittle and Dept. : Zvegincevs Edmunds / Engineer, R&D E-Mail : [email protected] Tel. : +371 6 7317700

Cover Letter(s)

August 29, 2011 Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Federal Communications Commission Equipment Approval Services P.O. Box 35815 Pittsburgh, PA 15251-3315 Applicant: Mikrotikls SIA Pernavas 46 Riga, Latvia LV-1009 Equipment: FCC ID: TV7RB751-2HND FCC Rules: CFR47, 15.247 2x2 MIMO 802.11 b/g/n Digital Transmission System Gentlemen: The form 731 and application have been electronically submitted and any attachments will be up loaded to your site to be used in obtaining grant of certification. Permanent Mikrotikls SIA requests that the material in the following files be withheld from public disclosure in accordance with Sections 0.457 and 0.459 of the Commission’s Rules, 47 CFR following grant of the application. Schematics File Name Conf Schem RB751U2HND.pdf Block diagram File Name Conf BlkDia RB751U2HND.pdf Operational Description File Name Conf OpDes RB751U2HND.pdf Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers Rogers Labs, Inc. Enclosures ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214

External Photos

Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 1, 2011 Revision 1 File: ExtPho RB751U2HnD Page 1 of 3 External photographs of equipment under test Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 1, 2011 Revision 1 File: ExtPho RB751U2HnD Page 2 of 3 Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 1, 2011 Revision 1 File: ExtPho RB751U2HnD Page 3 of 3

ID Label/Location Info

Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: August 29, 2011 Revision 1 File: LabelSmpl RB751U2HnD Page 1 of 1 Label and Placement

Internal Photos

Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: August 29, 2011 Revision 1 File: IntPho RB751U2HnD Page 1 of 2 Internal photographs of equipment under test (shield in place) Shield removed for photograph Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: August 29, 2011 Revision 1 File: IntPho RB751U2HnD Page 2 of 2 Back side of EUT PCB (heat sink in place – No components placed under heat sink)

Parts List/Tune Up Info

RouterBOARD 751-2HnD 802.11b/g/n WLAN router Tuning procedure Each units TX and RX functionality is tested and judged with a pass/fail criteria during production. Units meeting the criteria continue through production and others are returned for diagnostics.

RF Exposure Info

Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: August 29, 2011 Revision 1 File: RFExp RB751U2HnD Page 1 of 1

Test Report

NVLAP Lab Code 200087-0 Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 1, 2011 Revision 1 File: Mikrotikls RB51U 2HnD 110802 TstRpt Page 1 of 49 SUBMITTAL APPLICATION REPORT FOR GRANT OF CERTIFICATION FOR Model: RB751U-2HnD 2412-2462 MHz 2422-2452 MHz (802.11n Mode) 2x2 MIMO 802.11 b/g/n Broadband Digital Transmission System FCC ID: TV7RB751-2HND FOR MIKROTIKLS SIA Pernavas 46 Riga, Latvia LV-1009 Test Report Number: 110802 Authorized Signatory: Scot D. Rogers NVLAP Lab Code 200087-0 Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 1, 2011 Revision 1 File: Mikrotikls RB51U 2HnD 110802 TstRpt Page 2 of 49 Engineering Test Report For Grant of Certification Application FOR CFR 47, PART 15C - Intentional Radiators CFR 47 Paragraph 15.247 License Exempt Intentional Radiator For MIKROTIKLS SIA Pernavas 46 Riga, Latvia LV-1009 2x2 MIMO 802.11 b/g/n Broadband Digital Transmission System Model: RB751U-2HnD Frequency Range 2412-2462 MHz, 2422-2452 MHz (802.11n mode) FCC ID#: TV7RB751-2HND Test Date: August 2, 2011 Certifying Engineer: Scot D. Rogers Rogers Labs, Inc. 4405 West 259 th Terrace Louisburg, KS 66053 Telephone/Facsimile: (913) 837-3214 This report shall not be reproduced except in full, without the written approval of the laboratory. This report must not be used by the client to claim product endorsement by NVLAP, NIST, or any agency of the U.S. Government. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214 NVLAP Lab Code 200087-0 Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 1, 2011 Revision 1 File: Mikrotikls RB51U 2HnD 110802 TstRpt Page 3 of 49 Table Of Contents TABLE OF CONTENTS .................................................................................................. 3 FORWARD ..................................................................................................................... 6 OPINION / INTERPRETATION OF RESULTS ............................................................... 6 ENVIRONMENTAL CONDITIONS.................................................................................. 6 EQUIPMENT TESTED .................................................................................................... 6 APPLICATION FOR CERTIFICATION ........................................................................... 7 APPLICABLE STANDARDS & TEST PROCEDURES .................................................. 8 EQUIPMENT FUNCTION AND CONFIGURATION ........................................................ 8 Equipment Configuration.................................................................................................................................... 9 TEST SITE LOCATIONS ................................................................................................ 9 UNITS OF MEASUREMENTS ........................................................................................ 9 TEST PROCEDURES ................................................................................................... 10 AC Line Conducted Emission Test Procedure ................................................................................................ 10 Radiated Emission Test Procedure ................................................................................................................... 10 LIST OF TEST EQUIPMENT ........................................................................................ 11 INTENTIONAL RADIATORS ........................................................................................ 12 Antenna Requirements ...................................................................................................................................... 12 Restricted Bands of Operation .......................................................................................................................... 12 Radiated Emissions in Restricted Bands Data (worst-case configuration presented) ........................................ 12 Summary of Results for Radiated Emissions in Restricted Bands ................................................................ 13 AC Line Conducted Emissions Procedure ....................................................................................................... 13 Figure 1 AC Line Conducted Emissions Line 1 ................................................................................................ 14 Figure 2 AC Line Conducted Emissions Line 2 ................................................................................................ 14 AC Line Conducted Emissions Data (Highest Emissions) ................................................................................ 15 Summary of Results for AC Line Conducted Emissions ................................................................................ 15 NVLAP Lab Code 200087-0 Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: September 1, 2011 Revision 1 File: Mikrotikls RB51U 2HnD 110802 TstRpt Page 4 of 49 General Radiated Emissions Procedure ........................................................................................................... 16 Figure 3 General Radiated Emissions taken at 1 meter in screen room ............................................................. 17 Figure 4 General Radiated Emissions taken at 1 meter in screen room .....................…

Text truncated - open the document above for the full version.

Test Setup Photos

Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: August 29, 2011 Revision 1 File: TSup RB751U2HnD Page 1 of 4 Test setup photographs AC Line Conducted Emissions Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: August 29, 2011 Revision 1 File: TSup RB751U2HnD Page 2 of 4 Radiated Emissions Internal Antenna Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: August 29, 2011 Revision 1 File: TSup RB751U2HnD Page 3 of 4 Omni Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RB751U-2HnD SN: 2B67011CE826 Louisburg, KS 66053 Test #: 110802 FCC ID#: TV7RB751-2HND Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: August 29, 2011 Revision 1 File: TSup RB751U2HnD Page 4 of 4 Panel

Contact Information

Applicant

Edmunds Zvegincevs(engineer, R&D)
[email protected]+371 67317700Fax: +371 67317701

Test Firm

Rogers Labs, Inc.Scot Rogers
[email protected]913-837-3214Fax: 913-837-3214

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.42 GHz - 2.45 GHz200.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is combined conducted output power. Professional installation is required. This device is supplied with specific antennas as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 75 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and Installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Device is operating in 2x2 Spatial Multiplexing/Cyclic Delay Diversity MIMO configurations and single-stream legacy modes as described in this filing. When operating in the 40 MHz mode, the operating frequency segment is limited to 2422-2452 MHz

Other Applications from Mikrotikls SIA

TV7A42BE52

hAP be lite

Jul 16, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
TV7MA53BE652

MA53UG+HbeH

May 16, 2026

Equipment Class

6ID - 15E 6 GHz Low Power Indoor Access Point
TV7-TGLR92

TG-LR92

Feb 05, 2026

Equipment Class

DTS - Digital Transmission System
TV7WAPGR52AX

wAP ax

Sep 03, 2024

Equipment Class

JAB - Part 15 Class B Digital Device
R11e-LR2 - FCC ID TV7LR2 - Mikrotikls SIA
TV7LR2

R11e-LR2

May 16, 2023

Equipment Class

DTS - Digital Transmission System