Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
See www.routerboard.com for more information. Contact [email protected] for support questions. 7-May-2012 RouterBOARD 951-2n Quick Setup Guide and Warranty Information Connecting 1. Connect your WAN cable to port 1, and LAN PCs to ports 2-5 2. Set LAN computer IP configuration to automatic (DHCP) 3. Default IP address from LAN/WLAN is 192.168.88.1, open this address in your web browser to start configuration. The username is admin and there is no password (Alternatives are SSH, Telnet or Winbox tool) 4. Wireless AP mode is enabled by default, you can connect to the SSID “MikroTik”. Log into your router and configure a WPA password to secure your network Powering The device accepts powering from the power jack or from the first ethernet port (Passive PoE): DC power jack (5.5mm outside and 2mm inside diameter, female, pin positive plug) accepts 8-30V DC The first ethernet port accepts passive Power over Ethernet accepts 8-30V DC Under maximum load, the power consumption of this device is 7W Booting process RouterOS is the operating system of all RouterBOARD routers. Please see detailed configuration guide here http://wiki.mikrotik.com/wiki/Category:Manual This device doesn't come fitted with a Serial Port connector, so initial connection has to be done via the Ethernet cable, using the MikroTik Winbox utility. Winbox should be used to connect to the default IP address of 192.168.88.1 with the username admin and no password. In case you wish to boot the device from network, for example to use MikroTik Netinstall, hold the RESET button of the device when starting it until the LED light turns off, and Groove will start to look for Netinstall servers. In case IP connection is not available, Winbox can also be used to connect to the MAC address of the device. More information here: http://wiki.mikrotik.com/wiki/First_time_startup Extension Slots and Ports Five individual 10/100 Ethernet ports, supporting automatic cross/straight cable correction (Auto MDI/X), so you can use either straight or cross-over cables for connecting to other network devices. The First Ethernet port accepts 8-30V DC powering from a passive PoE injector. One Integrated Wireless 2.4GHz 802.11b/g/n, 1x1 MIMO with two onboard PIF antennas, max gain 1.5dBi One USB 2.0 port See www.routerboard.com for more information. Contact [email protected] for support questions. 7-May-2012 Buttons and Jumpers RouterOS reset jumper hole (on the bottom of case, behind one of the rubber feet) – resets RouterOS software to defaults. Must short circuit the metallic sides of the hole (with a screwdriver, for example) and boot the device. Hold screwdriver in place until RouterOS configuration is cleared. RouterBOOT reset button (RESET, front panel) has two functions: o Hold this button during boot time until LED light starts flashing, release the button to reset RouterOS configuration (same result as with RouterOS reset hole) o Hold this button during boot time longer, until LED turns off, then release it to make the RouterBOARD look for Netinstall servers. Operating System Support Currently tested operating system is MikroTik RouterOS starting from version v5.15 Copyright and Trademarks. Copyright MikroTikls SIA. This manual contains information protected by copyright law. No part of it may be reproduced or transmitted in any form without prior written permission from the copyright holder. RouterBOARD, RouterOS, RouterBOOT and MikroTik are trademarks of MikroTikls SIA. All trademarks and registered trademarks appearing in this manual are the property of their respective holders. Hardware. MikroTik warrants all RouterBOARD series equipment for the term of fifteen (15) months from the shipping date to be free of defects in materials and workmanship under normal use and service, except in case of damage caused by mechanical, electrical or other accidental or intended damages caused by improper use or due to wind, rain, fire or other acts of nature. To return failed units to MikroTik, you must perform the following RMA (Return Merchandise Authorization) procedure. Follow the instructions below to save time, efforts, avoid costs, and improve the speed of the RMA process. 1. If you have purchased your product from a MikroTik Reseller, please contact the Reseller company regarding all warranty and repair issues, the following instructions apply ONLY if you purchased your equipment directly from MikroTik in Latvia. 2. We do not offer repairs for products that are not covered by warranty. Exceptions can be made for RB1000 series. 3. Out-of-warranty devices and devices not covered by warranty sent to Mikrotikls will be returned to the sender at sender's cost. RMA Instructions are located on our webpage here: http://rma.mikrotik.com Manual. This manual is provided “as is” without a warranty of any kind, expressed or implied, including, but not limited to, the implied warranty of merchantability and fitness for a particular purpose. The manufacturer has made every effort to ensure the accuracy of the contents of this manual, however, it is possible that it may contain technical inaccuracies, typographical or other errors. No liability is assumed for any inaccuracy found in this publication, nor for direct or indirect, incidental, consequential or other damages that may result from such an inaccuracy, including, but not limited to, loss of data or profits. Please report any inaccuracies found to [email protected] See www.routerboard.com for more information. Contact [email protected] for support questions. 7-May-2012 Federal Communication Commission Interference Statement (FCC ID: TV7RB951-2N) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not install…
Text truncated - open the document above for the full version.
November 23, 2011 Federal Communications Commission Equipment Approval Services Post Office Box 358315 Pittsburgh, Pennsylvania 15215-5315 To Whom It May Concern: Please be advised that SIA "Mikrotikls" has authorized Scot Rogers of Rogers Labs, Inc. to act on behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters and submittals. All acts carried out by Rogers Labs, Inc. on our behalf shall have the same effects as our own. Rogers Labs, Inc. is authorized to receive and exchange data between our company and the Commission. This Authorization is made pursuant to Paragraph 2.911 of FCC Rules CFR 47. This Authorization is in effect until otherwise notified in writing. Name: Edmunds Zvegincevs Title: Project Engineer Signature of applicant: SIA "Mikrotīkls" VAT # LV40003286799 Billing addr.: Aizkraukles iela 23, LV-1006, Rīga Office addr.: Pērnavas iela 46, LV-1009, Rīga Phone: +371 7317700 Fax: +371 7317701
May 2, 2012 Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Office of Engineering and Technology Federal Communications Commission Columbia, MD 21046 Applicant: Mikrotikls SIA Pernavas 46 Riga, Latvia LV-1009 Re: Confidentiality for submittal information regarding FCC ID number TV7RB951-2N PRODUCT: Broadband Digital Transmission System operating under CFR47 part 15.247 Dear Sirs: Mikrotikls SIA requests that the material in the Schematics, Operational Description, Block diagram, and parts list be withheld from public disclosure pursuant to Sections 0.457 and 0.459 of the Commission’s Rules following grant of the application. In support of this request, Mikrotikls submits the following: Long Term Confidential Files Include Schematics File Name Conf Schem RB951 2N.pdf Block diagram File Name Conf BlkDia RB951 2N.pdf Operational Description File Name Conf OpDes RB951 2N.pdf 1. Identification of the specific information for which confidential treatment is sought: The materials set forth in the Operational Description, block diagram, and Schematics, which are segregated from the non-confidential exhibits of the application, are those for which confidentiality is sought. 2. Identification of the Commission proceeding in which the information was submitted or a description of the circumstances giving rise to the submission: The proceeding is that involving the application for equipment authorization (certification) under FCC ID No: TV7RB951-2N 3. Explanation of the degree to which the information is commercial or financial, or contains a trade secret or is privileged: This material includes a detailed theory of operation, circuit diagrams, (schematic diagrams) and any detail Parts List. As such, this material is treated as highly confidential business information. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 4. Explanation of the degree to which the information concerns a service that is subject to competition: The material for which confidentiality is sought is employed in the design and manufacture of this transmitting equipment that is offered on a highly competitive basis. Customers for this equipment have a variety of competing sources. 5. Explanation of how disclosure of the information could result in substantial competitive harm: Disclosure would, in effect, give away the fruits of the labors of Mikrotik engineering personnel, who have designed the equipment and the manufacturing process. Disclosure would also offer competitors additional unwarranted insight into the state of the product development, thereby allowing competitors an advantage, not available to Mikrotikls SIA 6. Identification of any measures taken by the submitting party to prevent unauthorized disclosure: The information for which confidential treatment is sought is kept confidential by Mikrotikls SIA and not made available to third parties except pursuant to non-disclosure agreements. 7. Identification of whether the information is available to the public and the extent of any previous disclosure of the information to third parties: To the knowledge of those preparing this application, the information has not been disclosed publicly heretofore. While the general theory of operation of this equipment has been the subject of numerous disclosures in industry and standards groups as well as in rule making proceedings of the FCC, the protection sought is narrowly drawn and pertains to certain specific implementations of this radio technology. 8. Justification of the period during which the submitting party asserts that the material should not be available for public disclosure: This material should not be disclosed for at least 25 years. While improvements in design are made relatively frequently, disclosure of the design information would lead to insights into both design and manufacturing techniques that could have an adverse competitive effect for many years to come. As such, it is important that the design not be made available to unauthorized persons who might attempt to use knowledge of the design to compromise the applications for which the equipment will be employed. Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers
May 2, 2012 Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Federal Communications Commission Equipment Approval Services P.O. Box 35815 Pittsburgh, PA 15251-3315 Applicant: Mikrotikls SIA Pernavas 46 Riga, Latvia LV-1009 Equipment: FCC ID: TV7RB951-2N FCC Rules: Part 15.247 Digital Transmission System approval Men: The form 731 and application have been electronically submitted and any attachments will be up loaded to your site to be used in obtaining grant of certification. Permanent Mikrotikls SIA requests that the material in the Schematics, Operational Description, Block diagram, and parts list be withheld from public disclosure pursuant to Sections 0.457 and 0.459 of the Commission’s Rules following grant of the application. Schematics File Name Conf Schem RB951 2N.pdf Block diagram File Name Conf BlkDia RB951 2N.pdf Operational Description File Name Conf OpDes RB951 2N.pdf Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers Rogers Labs, Inc. Enclosures ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214
Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RouterBoard 951-2n FCC ID#: TV7RB951-2N Louisburg, KS 66053 Test #: 120314 SN: 35D70283C9DA/207 Phone/Fax: (913) 837-3214 Test to: FCC (15.247) Date: April 17, 2012 Revision 1 File: ExtPho RB951 2n Page 1 of 2 External photographs of equipment under test Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RouterBoard 951-2n FCC ID#: TV7RB951-2N Louisburg, KS 66053 Test #: 120314 SN: 35D70283C9DA/207 Phone/Fax: (913) 837-3214 Test to: FCC (15.247) Date: April 17, 2012 Revision 1 File: ExtPho RB951 2n Page 2 of 2
Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RouterBoard 951-2n FCC ID#: TV7RB951-2N Louisburg, KS 66053 Test #: 120314 SN: 35D70283C9DA/207 Phone/Fax: (913) 837-3214 Test to: FCC (15.247) Date: May 2, 2012 Revision 1 File: LabelSmpl RB951 2n Page 1 of 1 Label and Placement Label
Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RouterBoard 951-2n FCC ID#: TV7RB951-2N Louisburg, KS 66053 Test #: 120314 SN: 35D70283C9DA/207 Phone/Fax: (913) 837-3214 Test to: FCC (15.247) Date: April 17, 2012 Revision 1 File: IntPho RB951 2n Page 1 of 1 Internal photographs of equipment under test (inside enclosure)
RouterBOARD 951-2n 802.11b/g/n WLAN router Tuning procedure Each units TX and RX functionality is tested and judged with a pass/fail criteria during production. Units meeting the criteria continue through production and others are returned for diagnostics.
Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RouterBoard 951-2n FCC ID#: TV7RB951-2N Louisburg, KS 66053 Test #: 120314 SN: 35D70283C9DA/207 Phone/Fax: (913) 837-3214 Test to: FCC (15.247) Date: May 2, 2012 Revision 1 File: RFExp RB951 2n Page 1 of 1 MikrotikModel: RouterBOARD 951-2nTest Number:120314 MPE CalculatorMPE uses EIRP for calculation. EIRP is based on TX power added to the antenna gain in dBi. dBi = dB gain compared to an isotropic radiator. S = power density in mW/cm^2 Antenna Gain (dBi)0 Output PowerdBd + 2.17 = dBidBi to dBd2.2 Tx Frequency (MHz)2437Maximum (Watts)0.063000Antenna Gain (dBd)-2.17 Cable Loss (dB)0.0(dBm)17.99Antenna minus cable (dBi)0.00 Calculated ERP (mw)38.224EIRP = Po(dBM) + Gain (dB) Calculated EIRP (mw)63.000Radiated (EIRP) dBm17.993 ERP = EIRP - 2.17 dB Occupational Limit Radiated (ERP) dBm15.823 5.00000 mW/cm 2 50.00000 W/m 2 General Public Limit 1.00000 mW/cm 2 10.00000 W/m 2 Frequency (MHz)Occupational LimitPublic Limit 300-1,500f/300f/1500 1,500-10,00051 Frequency (MHz)Occupational LimitPublic Limit 300-1,500 (mW/cm2)8.1233333331.624666667 300-1,500 (W/m2)81.2333333316.24666667 1,500-10,000 (mW/cm2)51 1,500-10,000 (W/m2)5010 EIRPSSDistanceDistanceDistanceDistance milliwatts mW/cm 2 W/m 2 cmmeterinchesFeet 63.0000.000020.00020500.005.00196.850.42 63.0000.000030.00031400.004.00157.480.33 63.0000.000060.00056300.003.00118.110.25 63.0000.000130.00125200.002.0078.740.17 63.0000.000500.00501100.001.0039.370.08 63.0000.000620.0061990.000.9035.430.08 63.0000.000780.0078380.000.8031.500.07 63.0000.001020.0102370.000.7027.560.06 63.0000.001390.0139360.000.6023.620.05 63.0000.002010.0200550.000.5019.690.04 63.0000.003130.0313340.000.4015.750.03 63.0000.005570.0557030.000.3011.810.03 63.0000.012530.1253320.000.207.870.02 63.0000.050130.5013410.000.103.940.01 63.0000.200542.005355.000.051.970.00 63.0001.0358210.358222.200.020.870.00 63.0005.0133850.133811.000.010.390.00 Frequency (MHz) Occupational Limit minimum Distance (meters) Occupational Limit minimum Distance (cm / inches) Public Limit minimum distance (meters) Public Limit minimum distance (cm / inches) 300-1,500N/AN/AN/AN/A 1,500-10,0000.011.0 / 0.40.022.2 / 0.9 FCC radio frequency radiation exposure limits per 1.1310 (mW/cm2) FCC radio frequency radiation exposure limits per 1.1310 Power density (S) EIRP -------= mW/cm^2 4 p r^2 r (cm) EIRP (mW)
NVLAP Lab Code 200087-0 Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RouterBoard 951-2n SN: 35D70283C9DA/207 Louisburg, KS 66053 Test #: 120314 FCC ID#: TV7RB951-2N Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: May 8, 2012 Revision 1 File: Mikrotikls RB951 2n TstRpt 120314 Page 1 of 31 SUBMITTAL APPLICATION REPORT FOR GRANT OF CERTIFICATION FOR Model: RouterBoard 951-2n 2412-2462 MHz Broadband Digital Transmission System FCC ID: TV7RB951-2N FOR MIKROTIKLS SIA Pernavas 46 Riga, Latvia LV-1009 Test Report Number: 120314 Authorized Signatory: Scot D. Rogers NVLAP Lab Code 200087-0 Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RouterBoard 951-2n SN: 35D70283C9DA/207 Louisburg, KS 66053 Test #: 120314 FCC ID#: TV7RB951-2N Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: May 8, 2012 Revision 1 File: Mikrotikls RB951 2n TstRpt 120314 Page 2 of 31 Engineering Test Report For Grant of Certification Application FOR CFR 47, PART 15C - Intentional Radiators CFR 47 Paragraph 15.247 License Exempt Intentional Radiator For MIKROTIKLS SIA Pernavas 46 Riga, Latvia LV-1009 Broadband Digital Transmission System Model: RouterBoard 951-2n Frequency Range 2412-2462 MHz FCC ID#: TV7RB951-2N Test Date: March 14, 2012 Certifying Engineer: Scot D. Rogers Rogers Labs, Inc. 4405 West 259 th Terrace Louisburg, KS 66053 Telephone/Facsimile: (913) 837-3214 This report shall not be reproduced except in full, without the written approval of the laboratory. This report must not be used by the client to claim product endorsement by NVLAP, NIST, or any agency of the U.S. Government. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214 NVLAP Lab Code 200087-0 Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RouterBoard 951-2n SN: 35D70283C9DA/207 Louisburg, KS 66053 Test #: 120314 FCC ID#: TV7RB951-2N Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: May 8, 2012 Revision 1 File: Mikrotikls RB951 2n TstRpt 120314 Page 3 of 31 Table Of Contents TABLE OF CONTENTS .................................................................................................. 3 FORWARD ..................................................................................................................... 5 OPINION / INTERPRETATION OF RESULTS ............................................................... 5 ENVIRONMENTAL CONDITIONS.................................................................................. 5 EQUIPMENT TESTED .................................................................................................... 5 APPLICATION FOR CERTIFICATION ........................................................................... 6 APPLICABLE STANDARDS & TEST PROCEDURES .................................................. 7 EQUIPMENT FUNCTION AND CONFIGURATION........................................................ 7 Equipment Configuration.................................................................................................................................... 8 TEST SITE LOCATIONS ................................................................................................ 8 UNITS OF MEASUREMENTS ........................................................................................ 8 TEST PROCEDURES ..................................................................................................... 9 AC Line Conducted Emission Test Procedure .................................................................................................. 9 Radiated Emission Test Procedure ..................................................................................................................... 9 LIST OF TEST EQUIPMENT ........................................................................................ 10 INTENTIONAL RADIATORS ........................................................................................ 11 Antenna Requirements ...................................................................................................................................... 11 Restricted Bands of Operation .......................................................................................................................... 11 General Radiated Emissions in Restricted Bands Data (General) ..................................................................... 12 Harmonic Radiated Emissions in Restricted Bands Data .................................................................................. 12 Summary of Results for Radiated Emissions in Restricted Bands ................................................................ 13 AC Line Conducted Emissions Procedure ....................................................................................................... 13 NVLAP Lab Code 200087-0 Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RouterBoard 951-2n SN: 35D70283C9DA/207 Louisburg, KS 66053 Test #: 120314 FCC ID#: TV7RB951-2N Phone/Fax: (913) 837-3214 Test to: CFR47 (15.247) Date: May 8, 2012 Revision 1 File: Mikrotikls RB951 2n TstRpt 120314 Page 4 of 31 Figure One AC Line Conducted Emissions Line 1 ........................................................................................... 14 Figure Two AC Line Conducted Emissions Line 2 ........................................................................................... 14 AC Line Conducted Emissions Data (Highest Emissions) ................................................................................ 15 Summary of Results for AC Line Conducted Emissions ................................................................................ 15 General Radiated Emissions Procedure ........................................................................................................... 16 General Radiated Emissions from EUT Data (Highest Emissions all antenna options) .................................... 17 Summary of Results for General Radiated Emiss…
Text truncated - open the document above for the full version.
Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RouterBoard 951-2n FCC ID#: TV7RB951-2N Louisburg, KS 66053 Test #: 120314 SN: 35D70283C9DA/207 Phone/Fax: (913) 837-3214 Test to: FCC (15.247) Date: April 17, 2012 Revision 1 File: TSup RB951 2n Page 1 of 2 Test setup photographs AC Line Conducted Emissions Rogers Labs, Inc. Mikrotikls SIA 4405 W. 259th Terrace Model: RouterBoard 951-2n FCC ID#: TV7RB951-2N Louisburg, KS 66053 Test #: 120314 SN: 35D70283C9DA/207 Phone/Fax: (913) 837-3214 Test to: FCC (15.247) Date: April 17, 2012 Revision 1 File: TSup RB951 2n Page 2 of 2 Radiated Emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.42 GHz - 2.45 GHz | 20.00 mW |
hAP be lite
Equipment Class
NII - Unlicensed National Information Infrastructure TXMA53UG+HbeH
Equipment Class
6ID - 15E 6 GHz Low Power Indoor Access PointTG-LR92
Equipment Class
DTS - Digital Transmission SystemwAP ax
Equipment Class
JAB - Part 15 Class B Digital Device
R11e-LR2
Equipment Class
DTS - Digital Transmission System