FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sierra Wireless, ULC/
  3. TWV192513307X

TWV192513307XNetwork Access Device

Sierra Wireless, ULC
Network Access Device - FCC ID TWV192513307X - Sierra Wireless, ULC
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Feb 08, 2006
Application Purpose
Original Equipment
Date of Application
Feb 08, 2006
Equipment Note
Network Access Device
Frequency Range
824.20000000 - 848.80000000
Company
Sierra Wireless, ULC
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

DIGICELL ® ANYNET NETWORK ACCESS MODULE Product ID # 19-25133-070/-071 INSTALLATION AND USER’S GUIDE Network Status Service Comm Activity Input 1 Standard S3 off, S4 off Input 1 Pulse Ctr S3 off, S4 on Input 1 Timed Bell S3 on, S4 off Input 1 Sampled Siren S3 on, S4 on Network Interface Network Service Cellemetry ® GPRS SMS 1xRTT TCP/IP RS-232 Ethernet CDMA GSM AMPS Network Access Module DigiCell ® AnyNET IN 1IN 2IN 3IN 4 + -+ -+ -+ - OUTPUT 1 OUTPUT 2 12 VDC + - NETWORK S/N9200920999 19-25133-070 307V100B Revision 1 Dtd 12/30/05 © 2005 by Numerex No part of this publication may be reproduced or used in any form without permission in writing from Numerex. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice. Numerex reserves the right to make changes to any software or product to improve reliability, function or design. Uplink is a servicemark, DigiCell AnyNet, Cellemetry, and CellemetryXG are registered trademarks of Numerex Corp. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. TABLE OF CONTENTS Table of Contents ........................................................ 1 Warranty Information & Liability Waiver ..................... 1 Technical Support ........................................................ 2 Description .................................................................. 3 Installation Steps ........................................................ 4 Unit Wiring .................................................................. 6 Antenna Specification .................................................. 9 FCC & Industry Canada Regulatory Compliance ......... 10 1 WARRANTY INFORMATION & LIABILITY WAIVER The Company's Products Are Subject To The Following Limited Warranty: The company's products are warranted against defects in materials and workmanship for a period of one (1) year following the date of purchase, under normal use and ser- vice. The company's obligation under this limited warranty is limited to repairing or re- placing with reconditioned parts, at its option, any product proven to be defective in materials or workmanship under normal use and service. The company shall have no obligation if its products are altered or improperly repaired or serviced by any party other than the company. Except as set forth herein, the company's products are deliv- ered without warranty of any kind, whether express or implied, including any warranty of merchantability and any warranty that the company's products are fit for any partic - ular purpose. In no event shall company be liable for actions of third parties which may affect the performance of its products or other factors outside company's control which may require installation of additional equipment or affect the performance of the products. THE EXTERNAL ANTENNAS USED FOR THIS MODULE MUST PROVIDE A SEPARATION DISTANCE OF AT LEAST 20 CM FROM ALL PERSONS AND MUST NOT BE CO-LOCATED OR OPERATING IN CONJUNCTION WITH ANY OTHER ANTENNA OR TRANSMITTER . WARNING: Unauthorized antennas, modifications, or attachments could impair call quality, damage the Module, or result in violation of FCC regulations. Do not use the Module with a damaged antenna. Please contact your local authorized dealer for an- tenna replacement. IMPORTANT! Read these safety guidelines prior to using your Module. Failure to follow these rules and guidelines may be dangerous and/or illegal. 2 TECHNICAL SUPPORT Technical support is available Monday through Friday 8:00 AM to 8:00 PM ET excluding hol- idays. Before calling technical support please ensure you have read the installation guide com- pletely. Technical support requires you to provide: • Login name •Password •Serial number of the unit These items are required in order to assist you. UPLINK Technical Support 1600 Parkwood Circle, Suite 500 Atlanta, GA 30339 888-9-Uplink Fax: 770-693-3501 For Customer Support, call 888-987-5465, or visit www.uplink.com 3 DESCRIPTION DigiCell AnyNET ® Network Access Modules are comprised of various radio modules support- ing multiple analog and digital radio technologies. Supported technologies include GSM, CDMA, and AMPS. Supported services include Cellemetry ® and SMS for either GSM or CDMA. Support is also provided for expansion to broadband wireless. In addition, the Module can also be optionally ordered and configured with an IP communications module providing 10/100 Ethernet connectivity. All modules feature an RS-232 serial port that can be used to program the unit and execute firmware flash upgrades in the field. The port also provides serial connectivity to auxiliary devices, including SCADA systems and alarm panels. This AnyNET Module is an always on multi-purpose FCC certified device capable of sending and receiving digital data over the GSM Network. The operating frequencies are in the 850 MHz and 1900 MHz bands. The Module can be powered using a nominal 12 VDC supply and the transmitter is capable of operating as a class 4 (2 W output) on 850 MHz and Class 1 (1 Watt output) on 1900 MHz transmitter. The unit typically comes with a dual band quarter-wave antenna with frequency bands of 850 MHz and 1900 MHz. The Module’s four discrete inputs are triggered by DC voltage signals. The pulse counter can be set to report on demand, or it can be set to report and reset. The pulse counter automatically reports when the counter overflows and the power input reports a low battery condition of less than 10.2 VDC. CellemetryXG Network Operations Center Multi-mode/ Multi-path Network Access Module security monitoring mobile tracking environmental alarms vending intelligence asset management M2M Fixed and Mobile Applications M2M Customers Internet M2M Solution Partners Cellular Network 4 INSTALLATION STEPS 1.For new customers, establish an acco…

Text truncated - open the document above for the full version.

External Photos

ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 1 of 16 Appendix A. Pictures ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 2 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 3 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 4 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 5 of 16

ID Label/Location Info

00-25594-002 D Rev A AnyNet GSM Jan 23, 2006 Sheet 1 of 1 Size Label, Unit Bottom B ACDE 1234 1234 B ACDE General Notes 1 - All measurements are +/- 0.010 inches Rev AB Date 11/9/05 ECN 0035 Reason Initial Release Eng Revision History Correct for new NMRX address 2.30 Notes:1. Print to scale on clear mylar with mat finish2. Black Ink with protective coating3. Type Font - Arial4. Do not print border Scale: 2:1 2.42 This device complies with Part 15 of the FCCrules. Operation is subject to the following twoconditions: (1) this device may not cause harmfulinterference, and (2) this device must accept anyinterference received, including interference thatmay cause undesired operation. Certified tocomply with Class B limitsThis Class B digital apparatus complies withCanadian ICES-003. Made in USA Numerex 1600 Parkwood Circle Suite 500 Atlanta, GA 30339 770-693-5950 FCC ID: TWV192513307XIC: 6322A-2513307X C 1/18/06 Added IC field D 1/23/06 Added FCC and IC numbers

Internal Photos

ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 6 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 7 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 8 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 9 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 10 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 11 of 16

RF Exposure Info

___________________________________________________________________________________ ETS Handelsregister: Bankverbindung: Electronic Technology Systems Dr. Genz GmbH Amtsgericht Frankfurt/Oder HRB 5151 Sparkasse Oder-Spree Storkower Strasse 38c Geschäftsführung: Dr. Dietmar Genz BLZ 170 550 50 D-15526 Reichenwalde b. Berlin Norbert Kaspar Kto. Nr. 3105165974 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH RF Exposure Calculation Applicant: Numerex Corporation FCC ID: TWV192513307X The internal / external antennas used for this mobile transmitter must provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. A safety statement concerning minimum separation distances from enclosure of the Network Access Device will be integrated in the user’s manual to provide end-users with transmitter operating conditions for satisfying RF exposure compliance. The appropriate Max conducted power can be drawn from the test report no. G0M20512- 0056-P-2224. For transmitter operating in the 824-849 MHz range, paragraph 1.1310 Table 1 limits maximum permissible exposure (MPE) to 0.549 mW/cm² for uncontrolled environments and 2.75 mW/cm² for controlled environments. For transmitter operating in the 1850-1910 MHz range, paragraph 1.1310 Table 1 limits maximum permissible exposure (MPE) to 1 mW/cm² for uncontrolled environments and 5 mW/cm² for controlled environments. The far field on-axis power flux density (W/m²) is calculated using the following formula: S = Power density (mW/cm²) ERP = effective radiated power (mW) EIRP = isotropically radiated power (mW) r = Distance in cm Calculations ___________________________________________________________________________________ ETS Handelsregister: Bankverbindung: Electronic Technology Systems Dr. Genz GmbH Amtsgericht Frankfurt/Oder HRB 5151 Sparkasse Oder-Spree Storkower Strasse 38c Geschäftsführung: Dr. Dietmar Genz BLZ 170 550 50 D-15526 Reichenwalde b. Berlin Norbert Kaspar Kto. Nr. 3105165974 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ___________________________________________________________________________________ ETS Handelsregister: Bankverbindung: Electronic Technology Systems Dr. Genz GmbH Amtsgericht Frankfurt/Oder HRB 5151 Sparkasse Oder-Spree Storkower Strasse 38c Geschäftsführung: Dr. Dietmar Genz BLZ 170 550 50 D-15526 Reichenwalde b. Berlin Norbert Kaspar Kto. Nr. 3105165974 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH

Test Report

ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH FCC - TEST - REPORT FCC RULES PARTS 22 and 24 FCC ID: TWV192513307X Test report no.: G0M20512-0056-P-2224 Certificate 1983-01 ELECTRONIC TECHNOLOGY SYSTEMS STORKOWER STRASSE 38C, D-15526 REICHENWALDE B. BERLIN DR. GENZ GMBH PHONE +49-33631-888 00 FAX +49-33631-888 660 ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 1 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH TABLE OF CONTENTS 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of approval holder 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test environment 2.3 Test equipment utilized 2.4 General Test Procedure 3 Test Results 4 RF Power Output, FCC 2.1046 4.1 Test Procedure 4.2 Test Results 5 Radiated Power FCC 22.913, FCC 24.232 5.1 Test Procedure 5.2 Test Results 6 Modulation Deviation Limiting, FCC 2.1047, 22.915(b)(c) 6.1 Test Procedure 6.2 Test Results 7 Audio Filter Characteristics, FCC 22.915(d) 7.1 Test Procedure 7.2 Test Results 8 Emission Limitations, , FCC 2.1049 8.1 Test Procedure 8.2 Test Results 9 Occupied Bandwidth FCC 22.917(b)(d); FCC 2.1049 9.1 Test Procedure 9.2 Test Results 10 Out of Band Emissions at Antenna Terminals, FCC 24.238(a) 10.1 Test Procedure 10.2 Test results 11 Spurious Radiation, FCC 2.1053, 24.236 11.1 Test Procedure 11.2 Test Results ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 2 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 12 Line Conducted Emissions, FCC 15.207 12.1 Test Procedure 12.2 Test Results 13 Frequency Stability vs Temperature, FCC 2.1055, 22.355, 24. 235 13.1 Test Procedure 13.2 Test Equipment 14 Frequency Stability vs Voltage, FCC 2.1055, 22.355, 24.235 14.1 Test Procedure 14.2 Test Equipment ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 3 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH. Tester: 04.01.2006 M. Handrik Date ETS-Lab. Name Signature Technical responsibility for area of testing: 04.01.2006 N. Kaspar Date ETS Name Signature ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 4 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.2 Testing laboratory 1.2.1 Location ELECTRONIC TECHNOLOGY SYSTEM DR. GENZ GMBH (ETS) Storkower Straße 38c D-15526 Reichenwalde b. Berlin Germany Telephone : +49 33631 888 00 Telefax : +49 33631 888 66 1.2.2 Details of accreditation status A CCREDITED TESTING LABORATORY DAR-REGISTRATION NUMBER: TTI-P-G 126/96 A CCREDITED COMPETENT BODY DAR-REGISTRATION NUMBER: BPT-ZE-026/96 FCC FILED TEST LABORATORY REG. NO. 96970 BLUETOOTH QUALIFICATION TEST FACILITY (BQTF) ACCREDITED BY: BLUETOOTH QUALIFICATION REVIEW BOARD (BQRF) I NDUSTRY CANADA FILED TEST LABORATORY REG. NO. IC 3470 A2LA ACCREDITED Certificate Number: 1983-01 1.3 Details of approval holder Name : Numerex Corporation Street : 1600 Parkwood Circle, Suite 500 Town : Atlanta, GA 30339 Country : USA Telephone : 770.635.0730 Fax : 770.635.0731 Contact : Mr. Ed Jansson E-Mail : [email protected] ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 5 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.4 Application details Date of receipt of application : 12.12.2005 Date of receipt of test item : 12.12.2005 Date of test : 19.12.2005 - 29.12.2005; 24.01.2006 - 25.01.2006 1.5 Test item Description of test item : AnyNet Network Access Module Type identification : 19-225133-070 and 19-25133-071 Serial number : Test model without serial number. Photos : See annex A. Technical data Frequency range Tx – GSM 850 : 824.2 – 848.80 MHz Frequency range Tx – PCS : 1850.2 – 1909.8 MHz Frequency range Rx - GSM 850 : 869.2 – 893.8 MHz Frequency range Rx - PCS : 1930.2 – 1989.8 MHz Antenna Type Antenna 1 : Jinchang GSM-JC001 Dual Band ¼ Wave magnetic base antenna Antenna 2 : Jinchang GSM-JC000 Dual band ¼ wave antenna Antenna Gain, Antenna 1 : 3.5 dBi Antenna Gain, Antenna 2 : 3.0 dBi Power supply : 12.0 V DC Operating mode : duplex Type of modulation : GMSK (GSM modulation) Emission : GXW ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 6 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH Manufacturer: (if applicable) Name : Street : Town : Country : 1.6 Test standards Technical standard : FCC Parts 22, 24, 2, 15 Additional information : Because of using the GSM 850 as an alternative technology in 850 MHz band, not all test cases of FCC Part 22 are required. 2 Technical test 2.1 Summary of test results No deviations from the technical specification(s) were ascertained in the course : of the tests performed. or The deviations as specified in 2.5 were ascertained in the course of the tests … performed. 2.2 Test environment Temperature : 25 o C Relative humidity content : 20 ... 75 % Air pressure : 86 ... 103 kPa ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page…

Text truncated - open the document above for the full version.

Test Setup Photos

ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 12 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 13 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 14 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 15 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20512-0056-P-2224 Page 16 of 16

Contact Information

Applicant

YING WANG(Sr. Manager, Regulatory Compliance)
[email protected]6042311100Fax: 6042311109

Test Firm

Eurofins Product Service GmbHRobert Kschiwan-Kaspar
[email protected]49-33631-888-000Fax: 49-33631-888-660

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
222H824.2 MHz - 848.8 MHz1.68 W232KGXW47 Hz
Confidentiality
Long Term
Grant Notes
Power output listed is conducted for Part 22(GSM) and Part 24(PCS). The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical exclusion Requirements of �2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not exceed a gain of 3.5 dBi.

Other Applications from Sierra Wireless, ULC

WIRELESS FLEX TRANSMITTER - FCC ID TWV-FLEXSI - Sierra Wireless, ULC
TWV-FLEXSI

WIRELESS FLEX TRANSMITTER

Mar 05, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
SATELLITE TRANSMITTER - FCC ID TWV-SXL1FLEX - Sierra Wireless, ULC
TWV-SXL1FLEX

SATELLITE TRANSMITTER

Jun 16, 2011

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
WIRELESS PROGRAMMER - FCC ID TWV-SXL1 - Sierra Wireless, ULC
TWV-SXL1

WIRELESS PROGRAMMER

Apr 11, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
WIRELESS PROGRAMMER - FCC ID TWV-SXL1-P - Sierra Wireless, ULC
TWV-SXL1-P

WIRELESS PROGRAMMER

Feb 15, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Network Access Module - FCC ID TWV002557X - Sierra Wireless, ULC
TWV002557X

Network Access Module

Oct 30, 2007

Equipment Class

PCB - PCS Licensed Transmitter