FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Cognex Germany Aachen GmbH/
  3. TXH-DM7550

TXH-DM7550Handheld Reader for Industrial ID

Cognex Germany Aachen GmbH
Handheld Reader for Industrial ID - FCC ID TXH-DM7550 - Cognex Germany Aachen GmbH
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Feb 06, 2006
Application Purpose
Original Equipment
Date of Application
Feb 06, 2006
Equipment Note
Handheld Reader for Industrial ID
Frequency Range
2402.00000000 - 2480.00000000
Company
Cognex Germany Aachen GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

7500 7550 7550 1 2 3 4 5 6 1 Status: Red: read failed Green: read succeeded Blue: cordless link up Blinking red: low battery Trigger (press and hold to read) Charge: Steady green: fully charged Blinking green: charging Status: Steady red: connected to power Blinking red: data transfer Power Data (RS-232, USB, PS/2 Keyboard) Cable release (corded unit) Inserting device in base establishes Bluetooth® link and charges battery. Scan USB Serial or RS-232 Serial configuration code from the back of this document. Allow the Windows Found New Hardware Wizard to run. Select Automatic driver installation. When prompted during driver load, click Continue Anyway. 1. 2. Use setup tool to configure reader (shortcut on desktop) Common tasks Controls and information Question and Answer help 1. 2. 3. 2 2 1 2 3 Install Software Connect Device Place in Base (Cordless Only) Load USB Driver (USB Only) Scan Connection Code Start Setup Tool 1 USB: 42206416-01 RS-232: 42206139-04 USB: 42206161-01 RS-232: 42203758-03S Insert CD-ROM and install software (follow prompts). Run setup.exe if installer does not start automatically. You must have Administrator privileges to install. .NET Framework is installed if required. When prompted, click Continue Anyway. 1. • • • 2. Connect base or device to PC using USB or Serial cable (PS/2 keyboard cable is not supported by setup tool.) Connect base or device to power supply. 1. 2. i Copyright © 2006 Cognex Corporation All Rights Reserved This document may not be copied in whole or in part, nor transferred to any other media or language, without the written permission of Cognex Corporation. The hardware and portions of the software described in this document may be covered by one or more of the U.S. patents listed on the Cognex web site http://www.cognex.com/patents. asp. Other U.S. and foreign patents are pending. Cognex, the Cognex logo, and DataMan are trademarks, or registered trademarks, of Cognex Corporation. DataMan 590-6608 7500 ID Reader 7550 Cordless ID Reader Quick Reference 7500 Corded7550 Cordless Product support: http://support.cognex.com RS-232 Serial Weight270g (9.5 oz)330g (11.6 oz) Base: 250g (8.8 oz) Operating Temperature -10ºC — 50ºC (14ºF — 122ºF)0ºC — 50ºC (32ºF — 122ºF) Storage Temperature -40ºC — 70ºC (-40ºF — 158ºF)-40ºC — 60ºC (-40ºF — 140ºF) Charging Temperature 0ºC — 40ºC (32ºF — 104ºF) Maximum Humidity 95% (non-condensing) EnvironmentalIP52IP52 Base: IP41 Drop (Impact) 50 drops from 2m (6.5’) to concrete25 drops from 2m (6.5’) to concrete Codes Data Matrix TM (ECC 0, 50, 80, 100, 140, and 200) QR Code UPC/EAN/JAN Interleaved 2 of 5 Code 39, Code 128, and Code 93 Power Consumption 1000 mA @ 5 VDCBase: 800 mA @ 9 VDC Battery Life at 25ºC (77ºF)8h (normal use) PS/2 Keyboard Wedge USB Serial USB Keyboard Soft reset (save settings)Hard reset (discard settings) US EnglishFrench German Connection Keyboard Commands Setups CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. The battery should be disposed of by a qualified recycler or hazardous materials handler. Do not incinerate the battery or dispose of the battery with general waste materials. NOTE: Any modifications to this device not expressly approved by COGNEX CORPORATION may void your authority to operate it. Unlink base station Enable Setup 3 onlyEnable Setup 4 only Enable Setup 1 onlyEnable Setup 2 only See Configuration Codes in setup tool for more languages. 5 mil 10 mil 20 mil 0 - 35 mm (0 - 1.4 in) 13 mil0 - 62mm (0 - 2.4 in) 0 - 55 mm (0 - 2.1 in) 0 - 85 mm (0 - 3.3 in) 20 123 406080mm in Notes Reading Distance 1D Codes 2D Codes

Cover Letter(s)

1                                           ! "   #    $     ! "   # # # # % % % &      &  '  Letter of Confidentiality Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission ́s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential documents from public disclosure indefinitely. Operational Description Block Diagram Schematics Above mentioned documents contain detailed system and equipment description that are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitors an unfair advantage in the market Aachen, 31.01.2006 Guido Schützeichel, ID Products

External Photos

1                                           ! "   #    $     ! "   # # # # % % % &      &  '  External photographs: DM7550 from side DM7550 from front side 2                                           ! "   #    $     ! "   # # # # % % % &      &  '  DM7550 from top Battery is inserted here 3                                           ! "   #    $     ! "   # # # # % % % &      &  '  DM7550 from bottom DM7550 from back side DM7550 with released battery Battery is inserted here

ID Label/Location Info

F r t a L i e P g S e k o P n e t i t s ng Cognex Corp. www.cognex.com E 2 96 3 4 6 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la Class A est conforme a la norme NMB-003 du Canada. ITEM PART S/N IC: 6315A-DM7550 FCC ID: TXH-DM7550 DM7550 808-0005-1 C6XXYYYYY HW REV XX M 2:1 M 1:1 LABEL INFORMATION

Internal Photos

1                                           ! "   #    $     ! "   # # # # % % % &      &  '  Internal photographs: Open DM7550 with imager, illumination and main board Main board DM7550 top side 2                                           ! "   #    $     ! "   # # # # % % % &      &  '  Main board DM7550 rear side (w/ Bluetooth module) Open DM7550 with main board (rear side) Bluetooth antenna 3                                           ! "   #    $     ! "   # # # # % % % &      &  '  Open Bluetooth module with antenna

Test Report

The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-06-006-V01.00 Page 1 of 61 Date of issue: 03.02.06 Signature: Issue-No.: 01 Author: J.Steinbinder Test engineer Date of delivery: 5.01.06 Checked: W.Zapf Operational manager Testdates: 10.01. – 03.02.06 Pages: 61 ECL-EMC Test Report No.: 06-006 Equipment under test: COGNEX DataMan 7550 FCC ID: TXH-DM7550 IC: 6315A-DM7550 Type of test: FCC Part 15.247 for FHSS systems and Canada RSS-210 Measurement Procedures: ANSI C63.4 (2001) Test result: Passed EMC-Test Report No.: 06-006 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-06-006-V01.00 Page 2 of 61 Client: COGNEX Ltd. Vaalser Strasse 259 52074 Aachen Germany Manufacturer: Hand Held Products, Inc. 700 Visions Drive Skaneateles Falls, NY 13153 USA Testhouse: HERBERG Service Plus GmbH European Compliance Laboratory (ECL) Nordostpark 51 D-90411 Nürnberg Tel.: +49 0911 59835 91 Fax: +49 0911 59835 90 General: The purpose of the performed inspections and tests was to demonstrate that an equipment under defined environmental conditions can survive without irreversible failures and perform according to requirements. This report informs about the results of the EMC tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. EMC-Test Report No.: 06-006 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-06-006-V01.00 Page 3 of 61 Table of contents 1 INTRODUCTION..............................................................................................................................5 1.1 PURPOSE....................................................................................................................................5 1.2 TEST RESULTS SUMMARY.............................................................................................................5 2 EQUIPMENT UNDER TEST.............................................................................................................6 2.1 EUT DESIGNATION.......................................................................................................................6 2.2 DESCRIPTION...............................................................................................................................6 2.3 CONFIGURATION..........................................................................................................................6 2.3.1 CONNECTIONS......................................................................................................................6 2.3.2 ADDITIONAL INFORMATION......................................................................................................6 2.3.3 USED SOFTWARE..................................................................................................................6 3 NORMATIVE REFERENCES............................................................................................................8 4 DESCRIPTION OF THE EMC TEST CENTRE..................................................................................9 4.1 REGISTRATIONS...........................................................................................................................9 4.2 SEMI ANECHOIC CHAMBER (SAC) W ITH MAXIMUM 10M MEASUREMENT DISTANCE..............................10 4.3 FULLY ANECHOIC CHAMBER (FAC) W ITH MAXIMUM 5M MEASUREMENT DISTANCE...............................11 4.4 FULLY ANECHOIC CHAMBER (FAC2) W ITH MAXIMUM 3M MEASUREMENT DISTANCE.............................12 4.5 FULLY ANECHOIC CHAMBER (STRIPLINE) .......................................................................................13 4.6 SHIELDED TEST CABINS...............................................................................................................14 4.7 INSTRUMENT ROOM....................................................................................................................15 4.8 MEASUREMENT UNCERTAINTY.....................................................................................................16 4.9 GROUND PLAN...........................................................................................................................17 5 MEASUREMENTS..........................................................................................................................19 5.1 CARRIER FREQUENCY SEPARATION §15.247(A) ...............................................................19 5.1.1 RESULTS............................................................................................................................19 5.2 NUMBER OF HOPPING CHANNELS §15.247(A) ..................................................................20 5.2.1 RESULTS............................................................................................................................20 5.3 TIME OF OCCUPANCY (DWELL TIME) §15.247(A) ...............................................................21 5.3.1 RESULTS............................................................................................................................21 5.4 SPECTRUM BANDWITH OF FHSS SYSTEM §15.247(A).......................................................22 5.4.1 RESULTS............................................................................................................................23 5.5 MAXIMUM PEAK OUTPUT POWER(CONDUCTED) §15.247(B)(1).............................................26 5.5.1 RESULTS............................................................................................................................27 5.6 MXIMUM PEAK OUTPUT POWER (RADIATED) §15.247 (B)(1).................................................30 5.6.1 RESULTS..........................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Setup photos : Radiated emission up to 1000 MHz Radiated emission up to 26 GHz EIRP

Contact Information

Applicant

Simon Juenger(Compliance Engineer)
[email protected]+49-241-9426-3559Fax: +49-241-9426-3544

Test Firm

Bureau Veritas Consumer Products Services GermanyMario Lehmann
[email protected]49-40-74041-2702Fax: 49-175-575-4778

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz780.00 µW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter.

Other Applications from Cognex Germany Aachen GmbH

50165 - FCC ID TXH-50165 - Cognex Germany Aachen GmbH
TXH-50165

50165

Jan 17, 2022

Equipment Class

DTS - Digital Transmission System
Wireless Module 50164 - FCC ID TXH-50164 - Cognex Germany Aachen GmbH
TXH-50164

Wireless Module 50164

Sep 21, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Barcode Scanner - FCC ID TXH-DM8000 - Cognex Germany Aachen GmbH
TXH-DM8000

Barcode Scanner

Dec 18, 2011

Equipment Class

DTS - Digital Transmission System
Bar code scanner base station - FCC ID TXH-IBASE - Cognex Germany Aachen GmbH
TXH-IBASE

Bar code scanner base station

Dec 18, 2011

Equipment Class

DTS - Digital Transmission System