Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Apr 09, 2014
Application Purpose
Original Equipment
Date of Application
Apr 09, 2014
Equipment Note
WLP Special
Frequency Range
3.84000000 - 3.84000000
Company
Oticon A/S
Country
Denmark

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PEOPLE FIRST Oticon A/S Kongebakken 9 DK-2765 Smørum www.oticon.com Main +45 39 17 71 00 Fax +45 39 27 79 00 Denmark CVR-no. 42334219 1 Oticon Radio Model - Quick Installation Guide Radio Model Name: WLP Special The WLP Special Radio Module is a module intended for WireLess Programming devices (WLPs) and completely equipped with both a microprocessor host and a short range low power radio system on board the same Printed-Circuit-Board (PCB). Besides the host and the radio system the module also includes a power management circuit, EEPROM memory, USB connector, battery connector, two neck loop connectors and small discrete components. When the WLP Special radio module is mounted inside plastic shells for a wireless programming device with a neck loop antenna attached, then the whole product shall normally be placed on the neck of an end user with one or two wireless hearing aids on the ears, also running at a radio frequency of 3.84 MHz. The end product shall be operated by a trained hearing care professional via a PC with Oticon certified SW controlling the product through an USB cable. The radio system inside the module is a low power, inductive radio transceiver working at 3.84 MHz and consisting of (see illustrations next page): - A radio transmitter controller - A radio receiver circuit - A frequency generating circuit and - A 16 MHz crystal The low power, inductive radio transmitter is consisting of a Complex Programmable Logic Device (CPLD) fed with data from the host, a clock oscillator and two switching transistors feeding the modulated RF signal at 3.84MHz to a dedicated neck loop antenna. The module mounted inside a plastic shell and with its loop antenna attached is depicted to the right: NB: The WLP Special radio module is ONLY intended for Oticon and OEM branded products intended for wireless programming of hearing aids at 3.84 MHz. If used for other types of products or systems, Oticon cannot guarantee continued conformance with FCC part 15 regulations. Because of this and due to limited shielding of the module, the WLP Special radio module is only approved with a limited modular approval. PEOPLE FIRST Oticon A/S Kongebakken 9 DK-2765 Smørum www.oticon.com Main +45 39 17 71 00 Fax +45 39 27 79 00 Denmark CVR-no. 42334219 2 Oticon Radio Model - Quick Installation Guide Radio Model Name: WLP Special The WLP Special Radio Module with all its mounted components is intended to be installed as a module into Oticons WireLess Programming devices (WLPs), (e.g. the FittingLINK WP-1) or similar OEM branded products (like Bernafon). The module requires only a battery to be mounted together with its neck loop antenna in an external plastic shell (as shown on the previous page). The module requires no microphones or speakers as no sound only data is streamed wirelessly to connected devices (e.g. Oticons wireless hearing aids). The module has its power management subsystem including all voltage regulators and the charging circuit on board. Also all data interfaces (input-output) on the board are buffered. The module PCB is depicted to the right with its main components and connections: WLP Special Radio Module PCB (Top side) WLP Special Radio Module PCB (Bottom side) PEOPLE FIRST Oticon A/S Kongebakken 9 DK-2765 Smørum www.oticon.com Main +45 39 17 71 00 Fax +45 39 27 79 00 Denmark CVR-no. 42334219 3 Oticon Radio Model - Regulatory Label Information Radio Model Name: WLP Special Contains: FCC ID: U28WLPS10 NOTICE: This device complies with Part 15 of the FCC Rules (hereunder §15.107/207, §15.109/209 and §15.223). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this equipment not expressly approved by Oticon A/S may void the FCC authorization to operate this equipment.

Cover Letter(s)

PEOPLE FIRST CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 8 th of April 2014. TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the following products: FCC ID Model name U28WLPS10 WLP Special For the product stated above, we request that the following information be held confidential: 1. Circuit diagrams, Bill-Of-Material (BOM), and PCBs submitted as Equipment Authorization Electronic Filing attachment: “Bill_Of_Material”, “Circuit Diagram” and “PCB_Layout”. 2. Block diagram submitted as Equipment Authorization Electronic Filing attachment: “Block diagram”. 3. Operational description submitted as Equipment Authorization Electronic Filing attachment: “Brief_Product_description” and “Datasheet”. The above exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Lars Bresler, QM-manager Oticon A/S Kongebakken 9 2765 Smorum DK-Denmark Phone: +45 3913 7100

Cover Letter(s)

PEOPLE FIRST SHORT-TERM CONFIDENTIALITY REQUEST Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 8 th of April 2014. TO WHOM IT MAY CONCERN Pursuant to the recent upgrade to the Office of Engineering and Technology’s (OET) Equipment Authorization System on 6/15/04 (ref. DA 04 –1705), Oticon A/S requests temporarily confidentiality for the following product: FCC ID Number Product Title/Model U28WLPS10 WLP Special For the product stated above, we request that the following information be held confidential: 1. External and Internal Photographs 2. Test Setup Photos 3. User Manual We request this confidentiality on the basis of ensuring that business sensitive information remains confidential for 90 days. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Lars Bresler, QM-manager Oticon A/S Kongebakken 9 2765 Smorum DK-Denmark Phone: +45 3913 7100

Cover Letter(s)

PEOPLE FIRST www.oticon.com Main +45 39 17 71 00 Fax +45 39 27 79 00 CVR-no. 42334219 Oticon A/S Kongebakken 9 DK-2765 Smørum Denmark Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road, Columbia, MD 21048 8 th of April 2014. Oticon ’WLP Special’ radio module with FCC ID: U28WLPS10 Limited Modular Approval Request We hereby request to approve the above product as a Limited Modular Approval in accordance with FCC Public Notice KDB 996369 D01 Transmitter Module Equipment Authorization Guide v01r04, released October 2013, and the rules of the Commission regarding modular transmitters (§15.212) operating under FCC’s part 15 about RF Devices. The requirements are met as follows:  15.212(a)(1)(i) The radio part of the module has no own RF shielding. Therefore we apply only for a Limited Modular Approval (See also §15.212(b)). The module is also constrained to be used by Oticon A/S or its affiliates or sold to Original Equipment Manufactures (OEM) only. The module contains a weak RF transmitter and therefore fulfils Part 15 emission limits without any additional RF shielding. The module is a fully integrated radio module for short range wireless programming of hearing aids, including microcontroller host and radio circuits on board and intended for Oticons and affiliates wireless hearing aids only. Therefore the module cannot be used directly by end users. The behaviour of the wireless module is locked by the design and can only be changed by Oticon A/S or its affiliates, so the compliance of the end product is always ensured.  15.212(a)(1)(ii) The module includes buffer stages for its external data/programming inputs.  15.212(a)(1)(iii) The wireless parts of the radio module share the power supply with digital parts, like the microprocessor host. Therefore we apply for a Limited Modular Approval with the same argumentation as in point 15.212(a)(1)(i).  15.212(a)(1)(iv) The low power inductive radio part of the WLP Special module has only a dedicated loop antenna connected to it and is mounted together with its battery in a fixed plastic shell, which is normally not interchangable by the end user.  15.212(a)(1)(v) The radio parts are included together with the microcontroller host inside the WLP Special module, which was tested in a stand-alone configuration as can be seen in the CETECOM test report no. 1- 7410/13-01-07. The module requires no external host, only some external plastic parts e.g. holding the battery and the loop antenna in fixed locations.  15.212(a)(1)(vi) The size of the module is big enough for the regulatory FCC label in its short form to be placed on the side of the plastic shell holding it, besides also to be found in user manuals and the installation guide.  15.212(a)(1)(vii) The module is compliant with all applicable FCC rules. Maintenance of compliance is always ensured as only Oticon A/S or its affiliates are able to alter the antenna or other wireless related behaviours.  15.212(a)(1)(viii) The module is compliant with all applicable RF exposure requirements. This is always ensured as only Oticon A/S or its affiliates are able to alter the antenna or other wireless related behaviours. If you have any questions, please feel free to contact us at the address shown below Sincerely, Lars Bresler, QM-manager Oticon A/S Kongebakken 9 2765 Smorum - DK-Denmark Phone: +45 3913 7100

External Photos

Test report no.: 1-7410/13-01-01_AnnexB 2014-04-02 Page 1 of 5 Annex B This test report annex is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report annex authorised: Marco Bertolino Testing Manager Test report no.: 1-7410/13-01-01_AnnexB 2014-04-02 Page 2 of 5 Inter nal p ho tos of the E UT Photo documentation: Photo 1: Photo 2: Test report no.: 1-7410/13-01-01_AnnexB 2014-04-02 Page 3 of 5 Photo 3: Photo 4: Test report no.: 1-7410/13-01-01_AnnexB 2014-04-02 Page 4 of 5 Photo 5: Test report no.: 1-7410/13-01-01_AnnexB 2014-04-02 Page 5 of 5 Docu men t his to r y Version Applied changes Date of release Initial release 2014-04-02

ID Label/Location Info

PEOPLE FIRST Oticon A/S Kongebakken 9 DK-2765 Smørum www.oticon.com Main +45 39 17 71 00 Fax +45 39 27 79 00 Denmark CVR-no. 42334219 1 Oticon Radio Model - Regulatory Label Information Radio Model Name: WLP Special Contains: FCC ID: U28WLPS10 NOTICE: This device complies with Part 15 of the FCC Rules (hereunder §15.107/207, §15.109/209 and §15.223). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this equipment not expressly approved by Oticon A/S may void the FCC authorization to operate this equipment.

Internal Photos

Test report no.: 1-7410/13-01-01_AnnexB 2014-04-02 Page 1 of 5 Annex B This test report annex is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report annex authorised: Marco Bertolino Testing Manager Test report no.: 1-7410/13-01-01_AnnexB 2014-04-02 Page 2 of 5 Inter nal p ho tos of the E UT Photo documentation: Photo 1: Photo 2: Test report no.: 1-7410/13-01-01_AnnexB 2014-04-02 Page 3 of 5 Photo 3: Photo 4: Test report no.: 1-7410/13-01-01_AnnexB 2014-04-02 Page 4 of 5 Photo 5: Test report no.: 1-7410/13-01-01_AnnexB 2014-04-02 Page 5 of 5 Docu men t his to r y Version Applied changes Date of release Initial release 2014-04-02

Test Report

2014-04-10 Page 1 of 28 TEST REPORT Test report no.: 1-7410/13-01-07-B Testing laboratory Applicant CETECOM ICT Services GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.cetecom.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2005) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12076-01-01 Area of Testing: Radio Communications & EMC (RCE) Oticon A/S Kongebakken 9 2765 Smørum / DENMARK Phone: +45 39 17 71 00 Fax: -/- Contact: Jørgen Peter Hanuscheck e-mail: [email protected] Phone: +45 39 13 85 38 Manufacturer Oticon A/S Kongebakken 9 2765 Smørum / DENMARK Test standard/s 47 CFR Part 15 Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency devices For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: WireLess Programming device (WLP) for hearing aids Model name: WLP Special FCC ID: U28WLPS10 IC: -/- Frequency: 3.84 MHz Technology tested: Modulated carrier Antenna: External loop antenna Power supply: 5.00 V DC by USB power supply PSAC05R-050T Temperature: +20 °C This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorised: Test performed: p.o. Stefan Bös Marco Bertolino Senior Testing Manager Testing Manager Test report no.: 1-7410/13-01-07-B 2014-04-10 Page 2 of 28 1 Table of contents 1 Table of contents ............................................................................................................................................ 2 2 General information ....................................................................................................................................... 3 2.1 Notes and disclaimer .......................................................................................................................... 3 2.2 Application details ............................................................................................................................... 3 3 Test standard/s ............................................................................................................................................... 3 4 Test environment ............................................................................................................................................ 4 5 Test item .......................................................................................................................................................... 4 5.1 Additional information ........................................................................................................................ 4 6 Test laboratories sub-contracted ................................................................................................................. 4 7 Description of the test setup ......................................................................................................................... 5 7.1 Radiated measurements ..................................................................................................................... 5 7.2 Open area site ...................................................................................................................................... 6 7.3 AC conducted ...................................................................................................................................... 7 7.4 Conducted measurements ................................................................................................................. 8 8 Summary of measurement results ............................................................................................................... 9 9 Additional comments ................................................................................................................................... 10 10 Measurement results ............................................................................................................................ 13 10.1 Field strength of the fundamental ................................................................................................ 13 10.2 Emission bandwidth ...................................................................................................................... 14 10.3 Occupied bandwidth ...................................................................................................................... 15 10.4 Field strength of the harmonics and spurious ........................................................................... 17 10.5 Spurious emissions conducted < 30 MHz ................................................................................... 22 11 Test equipment and ancillaries used for tests ................................................................................... 25 12 Observations ......................................................................................................................................... 26 Annex A Document history .......................................................................................................................... 27 Annex B Further information ........................................................................................................................ 27 Annex C Accreditation Certificate ............................................................................................................... 28 Test report no.: 1-7410/13-01-07-B 2014-04-10 Page 3 of 28 2 General information 2.1 Notes and disclaimer The test results of this test report relate exclusively…

Text truncated - open the document above for the full version.

Test Setup Photos

Test report no.: 1-7410/13-01-01_AnnexD 2014-04-02 Page 1 of 6 Annex D This test report annex is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report annex authorised: Marco Bertolino Testing Manager Test report no.: 1-7410/13-01-01_AnnexD 2014-04-02 Page 2 of 6 Test se tup ph o tos Photo documentation: Photo 1: Photo 2: Test report no.: 1-7410/13-01-01_AnnexD 2014-04-02 Page 3 of 6 Photo 3: Photo 4: Test report no.: 1-7410/13-01-01_AnnexD 2014-04-02 Page 4 of 6 Photo 5: Photo 6: Test report no.: 1-7410/13-01-01_AnnexD 2014-04-02 Page 5 of 6 Photo 7: Photo 8: Test report no.: 1-7410/13-01-01_AnnexD 2014-04-02 Page 6 of 6 Docu men t his to r y Version Applied changes Date of release Initial release 2014-04-02

Contact Information

Applicant

Per Klaus Nielsen(Certification Manager)
[email protected]+45 3917 7100Fax: +45 3927 7900

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]49-681-598-0Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115C3.84 MHz - 3.84 MHz-
Modular Type
Limited Single Modular Approval
Confidentiality
Long Term
Grant Notes
Limited Modular Approval. This module can only be installed in the end devices of the grantee under their control as described in this filing

Other Applications from Oticon A/S

hearing instrument with short range low power wireless radio - FCC ID U28FU2BTEPP - Oticon A/S
U28FU2BTEPP

hearing instrument with short range low power wireless radio

Jun 29, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Hearing Aid Module - FCC ID U28FU2DRIT - Oticon A/S
U28FU2DRIT

Hearing Aid Module

Aug 10, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Hearing Aid - FCC ID U28FU2CICWL - Oticon A/S
U28FU2CICWL

Hearing Aid

Jun 22, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
TV Adapter 2.0 - FCC ID U28TVBOX03 - Oticon A/S
U28TVBOX03

TV Adapter 2.0

Aug 19, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Audio Streaming Module - FCC ID U28CL2STRM - Oticon A/S
U28CL2STRM

Audio Streaming Module

Dec 19, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter