
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Quick Start Guide WatchGuard ® AP AP102 WatchGuard® Technologies, Inc. Guide de démarrage rapide Kurzanleitung Guida introduttiva Guía Rápida Guia de início rápido 快速設定手冊 1. Loosen the two screws on the rear cover of the AP device and remove the cover. 2. If you plan to use an AC power adapter, remove the plug from the right gasket opening. Then, connect the power adapter and push the cord into the right gasket opening. Note: If you use PoE, do not remove the plug from the right gasket opening. 3. Connect an Ethernet cable and push the cable into the left gasket opening. 4. Put the gasket cover over the gasket opening and push it in place. 5. Replace the AP device cover and tighten the screws. 6. Connect the other end of the Ethernet cable to your network. 7. Connect your power supply. The device powers on. The light on the front of the device flashes amber while the device boots up and then changes to steady green when the device is ready. Assign an IP Address to the WatchGuard AP Device There are two ways the WatchGuard AP device can get an IP address: • Automatic IP Address Configuration by DHCP - When first powered on, the WatchGuard AP device automatically requests an IP address from a DHCP server on your network. • Manual IP Address Configuration - If you do not use DHCP on your network, you must directly connect to the WatchGuard AP device to assign a static IP address. To set the IP address on your WatchGuard AP device: • Connect an Ethernet cable from the AP device to your computer. • Configure your computer to use these settings: IP Address: 192.168.1.2, Subnet mask: 255.255.255.0, Gateway: 192.168.1.1. • Open a web browser and type https://192.168.1.1. • To log in to the WatchGuard AP web UI, type the default password: wgwap. • Set the IP address of the AP device to an IP address on the same network as your XTM device. Connect the WatchGuard AP Device English 1 Pair the AP Device You can now pair the WatchGuard AP device with a Firebox or XTM device. 1. Use Policy Manager or the Fireware XTM Web UI to edit the Firebox or XTM device configuration. 2. Select Network > Gateway Wireless Controller. 3. Enable the Gateway Wireless Controller, and save the configuration to the Firebox or XTM device. 4. In the Gateway Wireless Controller configuration, on the Access Points tab, click Refresh to discover the AP device. 5. Select the unpaired Access Point and click Pair. 6. In the Pairing Passphrase dialog box, type the passphrase of the AP device. The default passphrase is wgwap. For detailed information about WatchGuard AP pairing, management, and configuration with your Firebox or XTM device, see the WatchGuard AP Device Setup section of the product Help at http:www.watchguard.com/help/documentation/xtm.asp 2 Package Contents • AP device and mounting kit • Quick Start Guide 1. 拧松 AP 设备后盖上的两个螺钉,卸下后盖。 2. 如果您打算使用交流电源适配器,请取下右侧密封口的塞子。然后,连接电 源适配器并将线缆推入右侧密封口。注意:如果您使用 PoE,请勿取下右侧 密封口的塞子。 3. 请连接以太网线缆并将其插入左侧密封口。 4. 将密封盖置于密封口上并将其推入到位。 5. 装上 AP 设备盖,然后拧紧螺钉。 6. 将以太网线缆的另一端连接到网络。 7. 连接电源。 这时设备处于开机状态。在启动期间,设备正面的 灯会呈琥珀色闪烁;设备准备就绪后,该指示 灯呈绿色常亮状态。 为 WatchGuard AP 设备分配 IP 地址 可通过两种方式为 WatchGuard AP 设备分配 IP 地址: • 通过 DHCP 自动配置 IP 地址 - 首次开机时,WatchGuard AP 设备会自动从您网络上的 DHCP 服 务器申请 IP 地址。 • 手动配置 IP 地址 - 如果您的网络中未使用 DHCP,则必须直接连接到 WatchGuard AP 设备以分 配静态 IP 地址。 要在 WatchGuard AP 设备上设置 IP 地址,请执行以下操作: • 通过以太网线缆将 AP 设备连接到您的计算机。 • 将您的计算机配置为使用以下设置:IP 地址:192.168.1.2,子网掩码:255.255.255.0, 网关:192.168.1.1。 • 打开 Web 浏览器并输入 https://192.168.1.1。 • 要登录 WatchGuard AP Web 用户界面,请输入默认密码:wgwap。 • 将 AP 设备的 IP 地址设置为相同网络上 XTM 设备使用的 IP 地址。 连接 WatchGuard AP 设备 简体中文 3 AP 设备配对 现在,您可以将 WatchGuard AP 设备与 Firebox 或 XTM 设备配对。 1. 使用 Policy Manager 或 Fireware XTM Web 用户界面编辑 Firebox 或 XTM 设备的配置。 2. 选择 Network> Gateway Wireless Controller。 3. 启用“Gateway Wireless Controller”,并将配置保存到 Firebox 或 XTM 设备。 4. 在“Gateway Wireless Controller”配置中,找到 Access Points 选项卡,然后单击 Refresh以查 找 AP 设备。 5. 选择未配对的接入点并单击 Pair。 6. 在 Pairing Passphrase 对话框中,输入 AP 设备的密码。默认密码为 wgwap。 有关 WatchGuard AP 配对、管理以及 Firebox 或 XTM 设备配置的详细信息,请参阅产品“Help” 中的“WatchGuard AP Device Setup”(WatchGuard AP 设备设置)部分,网址为 http://www.watchguard.com/help/documentation/xtm.asp 4 包装内容 • AP 设备和安装工具包 • 快速入门指南 1. Dévissez les deux vis situées sur le panneau arrière du périphérique AP et retirez le panneau. 2. Si vous comptez utiliser un adaptateur secteur, retirez la prise de l'orifice droit de l'ouverture jointée. Ensuite, branchez l'adaptateur secteur et insérez le cordon dans l'orifice droit de l'ouverture jointée. Remarque : Si vous utilisez PoE, ne retirez pas la prise de l'orifice droit de l'ouverture jointée. 3. Branchez un câble Ethernet et insérez ce câble dans l'orifice gauche de l'ouverture jointée. 4. Remettez le couvercle de l'ouverture jointée en place. 5. Replacez le panneau du périphérique AP et serrez les vis. 6. Connectez l'autre extrémité du câble Ethernet à votre réseau. 7. Branchez votre alimentation. Le périphérique se met sous tension. Le voyant situé à l'avant du périphérique clignote en couleur ambre lorsque le périphérique s'allume et devient vert lorsqu'il est prêt à être utilisé. Attribuer une adresse IP au périphérique WatchGuard AP Il y a deux façons d'attribuer une adresse IP au périphérique WatchGuard AP : • Configuration automatique de l'adresse IP grâce au protocole DHCP - Lorsque vous l'allumez pour la première fois, le périphérique WatchGuard AP demande automatiquement une adresse IP au serveur DHCP de votre réseau. • Configuration manuelle de l'adresse IP - Si vous n'utilisez pas le protocole DHCP sur votre réseau, vous devez vous connecter directement au périphérique WatchGuard AP pour lui attribuer une adresse IP statique. Pour définir une adresse IP sur votre périphérique WatchGuard AP : • Connectez un câble Ethernet reliant le périphérique AP et votre ordinateur. • Configurez votre ordinateur avec les paramètres suivants : adresses IP : 192.168.1.2, masque de sous-réseau : 255.255.255.0, passerelle : 192.168.1.1. • Ouvrez votre navigateur Web et saisissez https://192.168.…
Text truncated - open the document above for the full version.
Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3 Page 4
Manufacturing SOP WatchGuard Technologies. 415-4805-277 Rev A Page 4 of 9 Authorization and Revision History for this document is available in the WatchGuard ECO system UNCONTROLLED COPY WHEN PRINTED 5.0 Required Labels Labels on Device QTY On Device QTY On Gift Box QTY On Shipper Box Cert/Serial Number 1 SKU Label 1 1 Serial Number Label 1 Shipping Label 1 RTTE label 1 1 6.0Bottom Side of Device Install serial number/certification label on back side of unit as shown below.
Manufacturing SOP WatchGuard Technologies. 415-4805-277 Rev A Page 8 of 9 Authorization and Revision History for this document is available in the WatchGuard ECO system UNCONTROLLED COPY WHEN PRINTED On Device Combined Cert & Serial Number Label On Gift Box: SKU Label On Gift Box: Serial Number On Gift Box: RTTE Label
Page 5 Page 6 Page 7 Page 8 Page 9 Page 10
FCC ID: U2M-AP102 Report No.: RF140102C03 Operational Description This device is a Wireless 802.11abgn Access Point, which operates in 2.4GHz & 5.0GHz band; the maximum data rate could be up to 300Mbps which OFDM technique. If the signal to noise radio is too poor which could not support 300Mbps, the 11Mbps data rate with DSSS technique will be applied. The transmitter of the EUT is powered by the 12Vdc from AC adapter or 48Vdc from POE. The EUT is used PIFA antenna with I-PEX connector. The other instruction, please have a look at the user’s manual.
Report No.: SA140102C03 1 of 5 Report Format Version 5.0.0 RF EXPOSURE REPORT REPORT NO.: SA140102C03 MODEL NO.: AP102 FCC ID: U2M-AP102 RECEIVED: Jan. 02, 2014 TESTED: Jan. 02 ~ Jan. 09, 2014 ISSUED: Feb. 14, 2014 APPLICANT: Senao Networks, Inc. ADDRESS: 3F, No. 529, Chung Cheng Rd., Hsintien, Taipei, Taiwan ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-com pliance to the specification. Report No.: SA140102C03 2 of 5 Report Format Version 5.0.0 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................................ 3 1. CERTIFICATION ............................................................................................................ 4 2. RF EXPOSURE .............................................................................................................. 5 2.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) ........................................ 5 2.2 MPE CALCULATION FORMULA ................................................................................... 5 2.3 CLASSIFICATION .......................................................................................................... 5 2.4 CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ................................. 5 Report No.: SA140102C03 3 of 5 Report Format Version 5.0.0 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED SA140102C03 Original release Feb. 14, 2014 Report No.: SA140102C03 4 of 5 Report Format Version 5.0.0 1. CERTIFICATION PRODUCT: Wireless 802.11abgn Access Point MODEL NO.: AP102 BRAND: WatchGuard APPLICANT: Senao Networks, Inc. TESTED: Jan. 02 ~ Jan. 09, 2014 TEST SAMPLE: ENGINEERING SAMPLE STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (model: AP102) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY :, DATE :Feb. 14, 2014 Celine Chou / Specialist APPROVED BY : , DATE :Feb. 14, 2014 Ken Liu / Senior Manager Report No.: SA140102C03 5 of 5 Report Format Version 5.0.0 2. RF EXPOSURE 2.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 2.2 MPE calculation Formula Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 2.3 Classification The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. 2.4 Calculation result of maximum conducted power FREQUENCY BAND (MHz) MAX POWER (dBm) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/cm 2 ) LIMIT (mW/cm 2 ) 2412-2462 27.25 6.51 20 0.473 1 5745-5825 25.32 9.01 20 0.539 1 NOTE: 1. 2.4CHz: Directional gain = 3.5dBi + 10log(2) = 6.51dBi 2. 5CHz: Directional gain = 6dBi + 10log(2) = 9.01dBi
Report No.: RF140102C03 1 of 100 Report Format Version 5.2.0 FCC TEST REPORT (15.247) REPORT NO.: RF140102C03 MODEL NO.: AP102 FCC ID: U2M-AP102 RECEIVED: Jan. 02, 2014 TESTED: Jan. 02 ~ Jan. 09, 2014 ISSUED: Feb. 14, 2014 APPLICANT: Senao Networks, Inc. ADDRESS: 3F, No. 529, Chung Cheng Rd., Hsintien, Taipei, Taiwan ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the com pliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF140102C03 2 of 100 Report Format Version 5.2.0 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................. 5 1. CERTIFICATION .......................................................................................................... 6 2. SUMMARY OF TEST RESULTS ................................................................................. 7 2.1 MEASUREMENT UNCERTAINTY ............................................................................... 7 3. GENERAL INFORMATION .......................................................................................... 8 3.1 GENERAL DESCRIPTION OF EUT ............................................................................ 8 3.2 DESCRIPTION OF TEST MODES ............................................................................ 10 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ............................ 11 3.3 DUTY CYCLE OF TEST SIGNAL .............................................................................. 15 3.4 DESCRIPTION OF SUPPORT UNITS ...................................................................... 17 3.4.1 CONFIGURATION OF SYSTEM UNDER TEST ....................................................... 17 3.5 GENERAL DESCRIPTION OF APPLIED STANDARDS ........................................... 19 4. TEST TYPES AND RESULTS (FOR 2.4GHz BAND) ................................................ 20 4.1 RADIATED EMISSION AND BANDEDGE MEASUREMENT .................................... 20 4.1.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT ................. 20 4.1.2 TEST INSTRUMENTS ............................................................................................... 21 4.1.3 TEST PROCEDURES ............................................................................................... 22 4.1.4 DEVIATION FROM TEST STANDARD...................................................................... 22 4.1.5 TEST SETUP ............................................................................................................. 23 4.1.6 EUT OPERATING CONDITIONS .............................................................................. 24 4.1.7 TEST RESULTS ........................................................................................................ 25 4.2 CONDUCTED EMISSION MEASUREMENT ............................................................ 39 4.2.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT .......................................... 39 4.2.2 TEST INSTRUMENTS ............................................................................................... 39 4.2.3 TEST PROCEDURES ............................................................................................... 40 4.2.4 DEVIATION FROM TEST STANDARD...................................................................... 40 4.2.5 TEST SETUP ............................................................................................................. 40 4.2.6 EUT OPERATING CONDITIONS .............................................................................. 40 4.2.7 TEST RESULTS ........................................................................................................ 41 4.3 6dB BANDWIDTH MEASUREMENT ......................................................................... 45 4.3.1 LIMITS OF 6dB BANDWIDTH MEASUREMENT ...................................................... 45 4.3.2 TEST SETUP ............................................................................................................. 45 4.3.3 TEST INSTRUMENTS ............................................................................................... 45 4.3.4 TEST PROCEDURE .................................................................................................. 45 4.3.5 DEVIATION FROM TEST STANDARD...................................................................... 45 4.3.6 EUT OPERATING CONDITION…
Text truncated - open the document above for the full version.
1 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST (TEST MODE A) 2 CONDUCTED EMISSION TEST (TEST MODE B) 3 RADIATED EMISSION TEST (TEST MODE A) 4 RADIATED EMISSION TEST (TEST MODE B)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 5.75 GHz - 5.83 GHz | 340.00 mW |

Ceiling Mount Access Point
Equipment Class
DTS - Digital Transmission SystemCloud Managed Wi-Fi 7 2x2 Wall-Plate Access Point
Equipment Class
NII - Unlicensed National Information Infrastructure TX
WiFi 7 Tri-radio concurrent indoor ceiling mount AP, Cloud Lite 802.11be 2x3x3 Tri-Band Managed Indoor Wireless Access Point
Equipment Class
NII - Unlicensed National Information Infrastructure TX
AX3000 Indoor Ceiling/Wall Mount AP, AX1800 Dual Band PoE WiFi 6 Access Point
Equipment Class
DTS - Digital Transmission SystemWiFi 7 Tri-radio concurrent indoor ceiling mount AP
Equipment Class
NII - Unlicensed National Information Infrastructure TX