COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. Copyright Β© 2011 Pepwave Ltd. All Rights Reserved. Pepwave and the Pepwave logo are trademarks of Pepwave Ltd. Other brands or products mentioned may be trademarks or registered trademarks of their respective owners. Pepwave MAX Series: MAX 600 / 700 / HD2 Document Rev. 5.2 September-11 http://www.pepwave.com 2 Copyright @ 2011 Pepwave Table of Contents 1 INTRODUCTION AND SCOPE ........................................................................................... 4 2 GLOSSARY ....................................................................................................................... 5 3 PRODUCT FEATURES ....................................................................................................... 6 3.1 SUPPORTED NETWORK FEATURES ........................................................................................................ 6 3.2 OTHER SUPPORTED FEATURES ............................................................................................................ 7 4 PEPWAVE MAX MOBILE ROUTER OVERVIEW ................................................................. 8 4.1 MAX 600 ..................................................................................................................................... 8 4.2 MAX 700 ..................................................................................................................................... 8 4.3 MAX HD2 .................................................................................................................................. 10 5 INSTALLATION ............................................................................................................... 14 5.1 PREPARATION ............................................................................................................................... 14 5.2 CONSTRUCTING THE NETWORK ......................................................................................................... 14 5.3 CONFIGURING THE NETWORK ENVIRONMENT ....................................................................................... 15 5.4 MOUNTING THE UNIT .................................................................................................................... 15 6 CONNECTING TO WEB ADMIN INTERFACE .................................................................... 17 7 CONFIGURATION OF LAN INTERFACE(S) ....................................................................... 19 7.1 BASIC SETTINGS............................................................................................................................. 19 7.2 WI-FI AP .................................................................................................................................... 22 8 CONFIGURATION OF WAN INTERFACE(S) ..................................................................... 24 8.1 ETHERNET WAN ..................................................................................................................... 25 8.2 EXPRESS CARD / PC CARD / USB1 / USB2 .................................................................... 32 8.3 WI-FI WAN ........................................................................................................................... 34 8.4 WAN HEALTH CHECK ..................................................................................................................... 37 8.5 BANDWIDTH ALLOWANCE MONITOR .................................................................................................. 39 9 WI-FI SETTINGS ............................................................................................................. 40 9.1 STP (SPANNING TREE PROTOCOL) ..................................................................................................... 42 10 SITE-TO-SITE VPN .......................................................................................................... 43 10.1 CONFIGURING A SITE-TO-SITE VPN PROFILE ........................................................................................ 43 10.2 LINK FAILURE DETECTION................................................................................................................. 45 10.3 PEPWAVE MAX BEHIND NAT ROUTER ............................................................................................... 47 10.4 VPN STATUS ................................................................................................................................ 48 11 MANAGEMENT OF OUTBOUND TRAFFIC TO WAN........................................................ 49 11.1 OUTBOUND POLICY ........................................................................................................................ 50 11.2 CUSTOM RULES FOR OUTBOUND POLICY ............................................................................................. 51 http://www.pepwave.com 3 Copyright @ 2011 Pepwave 12 PORT FORWARDING ..................................................................................................... 58 12.1 PORT FORWARDING SERVICE ............................................................................................................ 58 12.2 UPNP / NAT-PMP SETTINGS .......................................................................................................... 60 13 NAT MAPPINGS ............................................................................................................. 61 14 QOS .......................................................................................................................... 63 14.1 USER GROUPS .............................................................................................................................. 63 14.2 BANDWIDTH CONTROL .................................................................................................................... 64 14.3 APPLICATION .......................β¦
Text truncated - open the document above for the full version.
Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3 Page 4 Model No.: TQC-2400CI Page 5 Model No.: GPS-01 Page 6 Model No.: GSM-01 Page 7 Model No.: S040EM1200300 (Supply to DC Jack) Page 8 Page 9 Page 10 Model No.: S040EM1200300 (Supply to Terminal Block) Page 11 Page 12
(Fig.1) FCC ID: U8G-P1820 FCC LABEL LOCATION The label will be permanently affixed at a conspicuous location on the device. Back Side : LABEL
Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14
Report No.: SA110615E06B Report Format Version 4.0.0 Reference No.110906E04 1 RF EXPOSURE REPORT REPORT NO.: SA110615E06B MODEL NO.: MAX HD2, Device Connector M1, Express, AP Pro Duo, Air Connector Duo, Air Switch FCC ID: U8G-P1820 APPLICANT: Pismo Labs Technology Limited ADDRESS: 1703A, 17/F, Park Building 476 Castle Peak Road, Cheung Sha Wan, Kowloon, Hong Kong ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS: No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan This test report consists of 6 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced, except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval or endorsement by any government agency. The test results in the report only apply to the tested sample. Report No.: SA110615E06B Report Format Version 4.0.0 Reference No.110906E04 2 TABLE OF CONTENTS RELEASE CONTROL RECORD....................................................................................3 1. CERTIFICATION..............................................................................................4 2. RF EXPOSURE LIMIT.....................................................................................5 3. MPE CALCULATION FORMULA.....................................................................5 4. CLASSIFICATION............................................................................................5 5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER...................6 Report No.: SA110615E06B Report Format Version 4.0.0 Reference No.110906E04 3 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED SA110615E06B Original release Sep. 08, 2011 Report No.: SA110615E06B Report Format Version 4.0.0 Reference No.110906E04 4 1. CERTIFICATION PRODUCT: Pepwave Wireless Product BRAND NAME: Pepwave MODEL: MAX HD2, Device Connector M1, Express, AP Pro Duo, Air Connector Duo, Air Switch TEST SAMPLE: R&D SAMPLE APPLICANT: Pismo Labs Technology Limited STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (Model: MAX HD2) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sampleβs EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE: Sep. 08, 2011 ( Midoli Peng, Specialist ) APPROVED BY : , DATE: Sep. 08, 2011 ( May Chen, Deputy Manager ) Report No.: SA110615E06B Report Format Version 4.0.0 Reference No.110906E04 5 2. RF EXPOSURE LIMIT LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 1.34-30 824/f 2.19/f *(180/f 2 ) 30 30-300 27.5 0.073 0.2 30 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 3. MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r2) where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm Pd is the limit of MPE. If we know the maximum Gain of the antenna and the total power input to the antenna, through the calculation, we will know the MPE value at distance 20cm. Ref. : David K. Cheng, Field and Wave Electromagnetics, Second Edition, Page 640, Eq. (11-133). 4. CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Report No.: SA110615E06B Report Format Version 4.0.0 Reference No.110906E04 6 5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER For FCC Part 22H: Channel Channel Frequency (MHz) Output Power to Antenna (mW) ANTENNA GAIN (dBi) DISTANCE (cm) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 251 848.8 1258.9 3 20 0.500 0.566 Note: Limit of Electric field=F/1500 For FCC Part 24E: Channel Channel Frequency (MHz) Output Power to Antenna (mW) ANTENNA GAIN (dBi) DISTANCE (cm) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) 512 1850.2 707.9 3 20 0.281 1 Note: Limit of Electric field=F/1500 CONCLUSION: Both of the RFID and 2G/3G can transmit simultaneously, the formula of calculated the MPE is: CPD 1 / LPD 1 + CPD 2 / LPD 2 + ......etc. < 1 CPD = Calculation power density LPD = Limit of power density --- END ---
Report No.:RF110615E06 1 Report Format Version 4.0.0 FCC TEST REPORT (PART 22) REPORT NO.: RF110615E06 MODEL NO.: MAX HD2, Device Connector M1, Express, AP Pro Duo, Air Connector Duo, Air Switch FCC ID: U8G-P1820 RECEIVED: June 15, 2011 TESTED: Aug. 04 to 05, 2011 ISSUED: Aug. 23, 2011 APPLICANT: Pismo Labs Technology Limited ADDRESS: 1703A, 17/F, Park Building 476 Castle Peak Road, Cheung Sha Wan, Kowloon, Hong Kong ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS : No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan This test report consists of 111 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by any government agencies. The test results in the report only apply to the tested sample. Report No.:RF110615E06 2 Report Format Version 4.0.0 TABLE OF CONTENTS RELEASE CONTROL RECORD............................................................................................4 1 CERTIFICATION......................................................................................................5 2 SUMMARY OF TEST RESULTS..............................................................................6 2.1 MEASUREMENT UNCERTAINTY............................................................................7 3 GENERAL INFORMATION.......................................................................................8 3.1 GENERAL DESCRIPTION OF EUT.........................................................................8 3.2 DESCRIPTION OF TEST MODES.........................................................................12 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL..........................15 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS.........................................23 3.4 DESCRIPTION OF SUPPORT UNITS....................................................................24 3.5 CONFIGURATION OF SYSTEM UNDER TEST.....................................................25 4 TEST TYPES AND RESULTS................................................................................26 4.1 OUTPUT POWER MEASUREMENT......................................................................26 4.1.1 LIMITS OF OUTPUT POWER MEASUREMENT....................................................26 4.1.2 TEST INSTRUMENTS............................................................................................27 4.1.3 TEST PROCEDURES............................................................................................28 4.1.4 TEST SETUP.........................................................................................................29 4.1.5 EUT OPERATING CONDITIONS...........................................................................30 4.1.6 TEST RESULTS.....................................................................................................31 4.2 FREQUENCY STABILITY MEASUREMENT..........................................................42 4.2.1 LIMITS OF FREQUENCY STABILIITY MEASUREMENT.......................................42 4.2.2 TEST INSTRUMENTS............................................................................................42 4.2.3 TEST PROCEDURE...............................................................................................43 4.2.4 TEST SETUP.........................................................................................................43 4.2.5 TEST RESULTS.....................................................................................................44 4.3 OCCUPIED BANDWIDTH MEASUREMENT..........................................................47 4.3.1 LIMITS OF OCCUPIED BANDWIDTH MEASUREMENT.......................................47 4.3.2 TEST INSTRUMENTS............................................................................................47 4.3.3 TEST SETUP.........................................................................................................47 4.3.4 TEST PROCEDURES............................................................................................48 4.3.5 EUT OPERATING CONDITION..............................................................................48 4.3.6 TEST RESULTS.....................................................................................................49 4.4 BAND EDGE MEASUREMENT..............................................................................58 4.4.1 LIMITS OF BAND EDGE MEASUREMENT............................................................58 4.4.2 TEST INSTRUMENTS............................................................................................58 4.4.3 TEST SETUP.........................................................................................................58 4.4.4 TEST PROCEDURES............................................................................................59 4.4.5 EUT OPERATING CONDITION..............................................................................59 4.4.6 TEST RESULTS.....................................................................................................60 4.5 CONDUCTED SPURIOUS EMISSIONS.................................................................69 4.5.1 LIMITS OF CONDUCTED SPURIOUS EMISSIONS MEASUREMENT..................69 4.5.2 TEST INSTRUMENTS............................................................................................69 4.5.3 TEST PROCEDURE...............................................................................................70 Report No.:RF110615E06 3 Report Format Version 4.0.0 4.5.4 TEST SETUP.........................................................................................................70 4.5.5 EUT OPERATING CONDITIONS.................................................β¦
Text truncated - open the document above for the full version.
Report No.:RF110615E06-1 1 Report Format Version 4.0.0 FCC TEST REPORT (Part 24) REPORT NO.: RF110615E06-1 MODEL NO.: MAX HD2, Device Connector M1, Express, AP Pro Duo, Air Connector Duo, Air Switch FCC ID: U8G-P1820 RECEIVED: June 15, 2011 TESTED: Aug. 04 to 05, 2011 ISSUED: Aug. 23, 2011 APPLICANT: Pismo Labs Technology Limited ADDRESS: 1703A, 17/F, Park Building 476 Castle Peak Road, Cheung Sha Wan, Kowloon, Hong Kong ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan This test report consists of 111 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by any government agencies. The test results in the report only apply to the tested sample. Report No.:RF110615E06-1 2 Report Format Version 4.0.0 TABLE OF CONTENTS RELEASE CONTROL RECORD.................................................................................4 1 CERTIFICATION...........................................................................................5 2 SUMMARY OF TEST RESULTS...................................................................6 2.1 MEASUREMENT UNCERTAINTY.................................................................7 3 GENERAL INFORMATION............................................................................8 3.1 GENERAL DESCRIPTION OF EUT..............................................................8 3.2 DESCRIPTION OF TEST MODES..............................................................12 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL..............14 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS.............................23 3.4 DESCRIPTION OF SUPPORT UNITS........................................................24 3.5 CONFIGURATION OF SYSTEM UNDER TEST.........................................25 4 TEST TYPES AND RESULTS.....................................................................26 4.1 OUTPUT POWER MEASUREMENT...........................................................26 4.1.1 LIMITS OF OUTPUT POWER MEASUREMENT........................................26 4.1.2 TEST INSTRUMENTS.................................................................................27 4.1.3 TEST PROCEDURES.................................................................................28 4.1.4 TEST SETUP..............................................................................................29 4.1.5 EUT OPERATING CONDITIONS................................................................30 4.1.6 TEST RESULTS..........................................................................................31 4.2 FREQUENCY STABILITY MEASUREMENT...............................................42 4.2.1 LIMITS OF FREQUENCY STABILIITY MEASUREMENT...........................42 4.2.2 TEST INSTRUMENTS.................................................................................42 4.2.3 TEST PROCEDURE....................................................................................43 4.2.4 TEST SETUP..............................................................................................43 4.2.5 TEST RESULTS..........................................................................................44 4.3 OCCUPIED BANDWIDTH MEASUREMENT..............................................47 4.3.1 LIMITS OF OCCUPIED BANDWIDTH MEASUREMENT............................47 4.3.2 TEST INSTRUMENTS.................................................................................47 4.3.3 TEST SETUP..............................................................................................47 4.3.4 TEST PROCEDURES.................................................................................48 4.3.5 EUT OPERATING CONDITION...................................................................48 4.3.6 TEST RESULTS..........................................................................................49 4.4 BAND EDGE MEASUREMENT...................................................................58 4.4.1 LIMITS OF BAND EDGE MEASUREMENT................................................58 4.4.2 TEST INSTRUMENTS.................................................................................58 4.4.3 TEST SETUP..............................................................................................58 4.4.4 TEST PROCEDURES.................................................................................59 4.4.5 EUT OPERATING CONDITION...................................................................59 4.4.6 TEST RESULTS..........................................................................................60 4.5 CONDUCTED SPURIOUS EMISSIONS.....................................................69 Report No.:RF110615E06-1 3 Report Format Version 4.0.0 4.5.1 LIMITS OF CONDUCTED SPURIOUS EMISSIONS MEASUREMENT......69 4.5.2 TEST INSTRUMENTS.................................................................................69 4.5.3 TEST PROCEDURE....................................................................................70 4.5.4 TEST SETUP..............................................................................................70 4.5.5 EUT OPERATING CONDITIONS................................................................70 4.5.6 TEST RESULTS..........................................................................................71 4.6 RADIATED EMISSION MEASUREMENT (BELOW 1GHZ).........................89 4.6.1 LIMITS OF RADIATED EMISSION MEASUREMENT.................................89 4.6.2 TEST INSTRUMENTS.................................................................................90 4.6.3 TEST PROCEDURES..........................................................................β¦
Text truncated - open the document above for the full version.
1 PHOTOGRAPHS OF THE TEST CONFIGURATION RADIATED EMISSION TEST
81-1, Lu Laio Keng, 9th Ling, Wu Lung Tsuen, Chiun Β· Hsinchu Hsien Β· Taiwan
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 24E | 1.85 GHz - 1.91 GHz | 100.00 mW | 1M30F9W | 2.5 ppm |

Peplink Pepwave Wireless Product
Equipment Class
JAD - Part 15 Class A Digital Device
Peplink Pepwave Wireless Product
Equipment Class
JAD - Part 15 Class A Digital Device
Peplink Pepwave Wireless Product
Equipment Class
JAB - Part 15 Class B Digital Device
Peplink Pepwave Wireless Product
Equipment Class
JAD - Part 15 Class A Digital DevicePeplink Pepwave Wireless Product
Equipment Class
JAD - Part 15 Class A Digital Device