FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. IDS GeoRadar s.r.l./
  3. UFW-IBIS-SU

UFW-IBIS-SUIBIS Supply Unit

IDS GeoRadar s.r.l.
IBIS Supply Unit - FCC ID UFW-IBIS-SU - IDS GeoRadar s.r.l.
Click to zoom

Application Details

Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Date of Grant
Jun 20, 2010
Application Purpose
Original Equipment
Date of Application
Jun 20, 2010
Equipment Note
IBIS Supply Unit
Company
IDS GeoRadar s.r.l.
Country
Italy

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Tot. N° pages = 48 - PRO/010/M1 Rev 4 - INGEGNERIA DEI SISTEMI S.p.A. R ev. 1.1 N°doc: MN/2009/071 Config.: IBIS-S-PRCS-OUT-MN IBIS-S System IMAGE BY INTERFEROMETRIC SURVEY Pisa, June 2010 IBIS-S v. 1.0 - User Manual IDS Ingegneria Dei Sistemi S.p.A. N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN 2 / 48 All information contained in this document is property of IDS. All rights reserved. KEY WORDS IBIS-S, INTERFEROMETER, INSTALLATION SUMMARY IBIS-S system user manual. This document illustrates the contents of the package and the procedures the operator must perform to set up and dismantle the IBIS-S system. Document Evolution Revision Date Reason for change Rev. 1.0 October 2009 First Edition with Battery information (according to DL 188 dated 20/11/2008) Rev. 1.1 June 2010 Document revision for declarations for US and Canada (see RNC 201005097) Document change record RNC References Change description 201005097 Before index Declarations for US and Canadian customers HW and SW versions covered by this document IBIS-S apparatus v. 1.0. Warnings IDS will not be held responsible for the consequences of an improper use of the equipment. IDS will not be held responsible for the consequences of an improper use of the software All information contained in this document is property of IDS. IDS Ingegneria Dei Sistemi S.p.A. N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN 3 / 48 All information contained in this document is property of IDS. All rights reserved. Contacts IDS Ingegneria Dei Sistemi S.p.A. Via Sterpulino, 20 56121 PISA (Loc. Ospedaletto) Tel: +3905096711 Fax: +39050961721 IDS Ingegneria Dei Sistemi S.p.A. N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN 4 / 48 All information contained in this document is property of IDS. All rights reserved. DISCLAIMER IDS WILL NOT BE HELD RESPONSIBLE F OR THE CONSEQUENCES OF AN IMPROPER USE OF THE EQUIPMENT AND/ OR THE SOFTWARE. THIS SOFTWARE MAY INCLUDE AUTOMATED DATA PROCESSING AND ANALYSIS TOOLS. WHILE EVERY EFFORT IS MADE TO ENSURE THE ACCURACY OF THE INFORMATION PROVIDED BY THOS E TOOLS, THEY MUST NOT BE INTENDED AS A SUBSTITUTE FOR INTE LLIGENT ANALYSIS; RATHER, THEY HAVE TO BE INTEND ED AS AN ADVISOR AND THE USER MUST NOT COMPLETELY RELY ON THE RESULTS PROVIDED BY THEM TO GIVE THE COM PLETE ANSWER. IDS INGEGNERIA DEI SISTEMI SPA AS SUMES NO LIABILITY FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR INJURIES CAUSED BY SUCH RELIANCE ON THE ACCURACY, RELIABILITY, OR TIMELESS OF THE INFORMATION PROVIDED BY THOSE TOOLS. ANY PERSON OR ENTITY WHO RELIES ON INFORMATI ON OBTAINED FROM THE AUTOMATED DATA PROCESSING/ANALYSIS TOOLS ONLY , DOES SO AT HIS OR HER OWN RISK. IDS Ingegneria Dei Sistemi S.p.A. N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN 5 / 48 All information contained in this document is property of IDS. All rights reserved. SAFETY INFORMATION IDS Ingegneria Dei Sistemi S.p.A. N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN 6 / 48 All information contained in this document is property of IDS. All rights reserved. Warning: this equipment is destined for use in industrial environments (Class A apparatus). In residential, commercial and light industry environments, this apparatus may generate radio interference: in this case, the user may be required to operate while taking appropriate countermeasures. The apparatus is sensitive to the presence of external electromagnetic fields, which may reduce its performance. IDS Ingegneria Dei Sistemi S.p.A. N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN 7 / 48 All information contained in this document is property of IDS. All rights reserved. IMPORTANT NOTE FOR THE US CUSTOMERS Model No.: IBIS-KU FCC ID: UFW-IBIS-KU This device complies with part 90 of the FCC Rules. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum 20 cm between the radiator and your body. This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter unless authorized to do so by the FCC. IMPORTANT NOTE FOR THE CANADIAN CUSTOMERS Model No.: IBIS-KU IC ID: 8991A-IBISKU This device has been designed to operate with the antennas listed below, and having a maximum gain of 22 dB. Antennas not included in this list or having a gain greater than 22 dB are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. IBIS-ANT1-H38V18 IBIS-ANT2-H29V25 IBIS-ANT3-H17V15 IBIS-ANT4-H11V10 IBIS-ANT5-H12V39 IBIS-ANT6-H51V20 Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. IDS Ingegneria Dei Sistemi S.p.A. N doc: MN/2009/071 - Rev. 1.1 IBIS-S v. 1.0 - User Manual Config.: IBIS-S-PRCS-OUT-MN 8 / 48 All information contained in this document is property of IDS. All rights reserved. ! WARNING CLEANING INFORMATION Before cleaning any external parts of the apparatus, make sure that all cables have been disconnected, including the power supply cable. If a damp cloth is used, make sure it is not too wet, to avoid any damage to the electrical components of the equipment. Wait until the equipment is totally dry before reconnecting the cables. The IBIS-S should be cleaned periodically using a damp c…

Text truncated - open the document above for the full version.

Cover Letter(s)

INGEGNERIA DEI SISTEMI S.p.A. PISA Branch Office Via Sterpulino, 20 - 56121 PISA (Italy) Tel. +39.050.9671.11 - Fax +39.050.9671.21 e-mail: [email protected] www.idscompany.it PISA Headquarters Via Livornese, 1019 56122 PISA (Italy) Tel. +39.050.3124.1 Fax +39.050.3124.201 e-mail: [email protected] PISA Branch Office Via Sterpulino, 20 56121 PISA (Italy) Tel. +39.050.9671.11 Fax +39.050.9671.21 e-mail: [email protected] ROMA Branch Office Via Flaminia, 1068 00189 ROMA (Italy) Tel. +39.06.33217.11 Fax +39.06.33217.402 e-mail: [email protected] Capitale Sociale 5.000.000 Euro i.v. – C.C.I.A.A. Pisa, R.E.A. n° 77042 - C.F. 00672210507 – P. IVA (VAT) IT 00672210507 Share Capital 5.000.000 euro fully paid – registered at the Pisa Chamber of Commerce, R.E.A. n. 77042 – Tax number and VAT code (IT) 00672210507 02/06/2010 To: SIEMIC, INC. 2206 Ringwood Avenue, San Jose, CA 95131 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, _______Ingegneria dei Sistemi S.p.A._________hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): IBIS sensor IBIS Supply Unit IBIS Linear scanner We affirm that between SIEMIC and __ Ingegneria dei Sistemi S.p.A ___, any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Guido Manacorda, Engineering Manager Via Sterpulino 20, 56100 Pisa Italy

Cover Letter(s)

INGEGNERIA DEI SISTEMI S.p.A. PISA Branch Office Via Sterpulino, 20 - 56121 PISA (Italy) Tel. +39.050.9671.11 - Fax +39.050.9671.21 e-mail: [email protected] www.idscompany.it PISA Headquarters Via Livornese, 1019 56122 PISA (Italy) Tel. +39.050.3124.1 Fax +39.050.3124.201 e-mail: [email protected] PISA Branch Office Via Sterpulino, 20 56121 PISA (Italy) Tel. +39.050.9671.11 Fax +39.050.9671.21 e-mail: [email protected] ROMA Branch Office Via Flaminia, 1068 00189 ROMA (Italy) Tel. +39.06.33217.11 Fax +39.06.33217.402 e-mail: [email protected] Capitale Sociale 5.000.000 Euro i.v. – C.C.I.A.A. Pisa, R.E.A. n° 77042 - C.F. 00672210507 – P. IVA (VAT) IT 00672210507 Share Capital 5.000.000 euro fully paid – registered at the Pisa Chamber of Commerce, R.E.A. n. 77042 – Tax number and VAT code (IT) 00672210507 02/06/2010 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: UFW-IBIS-SU We hereby request confidential treatment of information accompanying this application as outlined below: - Schematics - Block Diagram - Operational description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Guido Manacorda, Engineering Manager Via Sterpulino 20, 56121 Pisa Italy INGEGNERIA DEI SISTEMI S.p.A. 02/06/2010 To: Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: Short Term Confidentiality Request for FCC ID: UFW-IBIS-SU To Whom It May Concern: Pursuant to sections 0.457 and 0.459 of CFR 47 and to avoid premature release of sensitive information prior to marketing or release of the product to the public, the applicant requests the following documents contained in this certification application be temporarily withheld from public disclosure for an initial period of 180 days: - User Manual - Internal Photo The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Sincerely, Sincerely, Client’s signature : Client’s name / title :Guido Manacorda, Engineering Manager Contact information / address : email: [email protected] Via Sterpulino 20, 56100 Pisa Italy

Cover Letter(s)

2206 Ringwood Avenue, San Jose, CA 95131, USA Tel: +1(408) 526 1188, Fax: +1(408) 526 1088, Email: [email protected], URL: www.siemic.com June 23, 2009 To: FCC From: SIEMIC, INC. RE: Applicant: Ingegneria dei Sistemi S.p.A, FCC ID: UFW-IBIS-SU, Request for supercede of test report exhibits Per customer’s request, There is some inappropriate information of EUT in the test report exhibits. These are very important information to customer for marketing purpose, therefore, we are asking to kindly replace the test report with revised copies. Thank you, Annie Jiang SIEMIC, INC. 2206 Ringwood Ave., San Jose, CA 95131 Tel: 408-526-1188 Ext 209 Fax: 408-526-1088

External Photos

MODEL: IBIS-SU-M EUT – Top View EUT - Front View-1 EUT - Front View-2 EUT – Rear View EUT - Port View

ID Label/Location Info

1.5” 2,5” FCC ID: UFW-IBIS-SU This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Model No: IBIS-SU-STD IBIS-SU- ADV

ID Label/Location Info

1.5” 2,5”

Internal Photos

IBIS Supply Unit Internal Pictures Fig. 1: Supply Unit Top View (PC housing) Fig. 2: Supply Unit Top View (PC housing) DC/DC converters Switches Power line filter Fig. 3: Supply Unit Front part Battery pack Battery charger Supply controller board DC/DC converters Fig. 4: Supply Unit Back part (connectors housing) Fig. 5: Supply Controller Board External View Fig. 6: Supply Controller Board Box view Fig. 7: Supply Controller Board (Top side) Fig. 8: Supply Controller Board (bottom side) Fig. 9: Battery Charger STD 482 (Top Side) Fig. 10: Battery Charger STD 482 (Bottom Side) Fig. 11: DC/DC converters (top side) Fig. 12: DC/DC converters (bottom side)

Test Report

INGEGNERIA DEI SISTEMI S.P.A POWER SUPPLY MODULE Model: IBIS-SU-STD, IBIS-SU-ADV June 13th 2010 Report No.: SL10050401-IDS-001_FCC(IBIS-SU-STD,IBIS-SU-ADV) Rev1.0 (This report supersedes SL10050401-IDS-001_FCC(IBIS-SU-STD,IBIS-SU-ADV)) Title: EMC Test Report of Power Supply Module To FCC Part 15B : 2009 Serial# SL10050401-IDS-001_FCC(IBIS-SU-STD,IBIS-SU-ADV) Rev1.0 Issue Date June 13th 2010 Page 2 of 44 www.siemic.com CERTIFICATE OF TEST Date of Issue : June 13th 2010 Company Name : Ingegneria dei Sistemi S.P.A Product Name/Model : Power Supply Module / IBIS-SU-STD, IBIS-SU-ADV Stipulated Standard: (1) FCC Part 15B : 2009 Equipment complied with the specification [X ] Equipment did not comply with the specification [ ] The submission documentation to a National Regulatory Body for type approval purposes shall consist of two parts; Part one: Application Form; Part two: Test Report; Modifications made to the product : None This Test Report is Issued Under the Authority of: David Zhang Compliance Engineer Leslie Bai Director of Certification This test report may be reproduced in full only. Title: EMC Test Report of Power Supply Module To FCC Part 15B : 2009 Serial# SL10050401-IDS-001_FCC(IBIS-SU-STD,IBIS-SU-ADV) Rev1.0 Issue Date June 13th 2010 Page 3 of 44 www.siemic.com Laboratory Introduction SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent testing and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications. In addition to testing and certification, SIEMIC provides initial design reviews and compliance management through out a project. Our extensive experience with China, Asia Pacific, North America, European, and international compliance requirements, assures the fastest, most cost effective way to attain regulatory compliance for the global markets . Accreditations for Conformity Assessment Country/Region Accreditation Body Scope USA FCC, A2LA EMC , RF/Wireless , Telecom Canada IC, A2LA, NIST EMC, RF/Wireless , Telecom Taiwan BSMI , NCC , NIST EMC, RF, Telecom , Safety Hong Kong OFTA , NIST RF/Wireless ,Telecom Australia NATA, NIST EMC, RF, Telecom , Safety Korea KCC/RRA, NIST EMI, EMS, RF , Telecom, Safety Japan VCCI, JATE, TELEC, RFT EMI, RF/Wireless, Telecom Mexico NOM, COFETEL, Caniety Safety, EMC , RF/Wireless, Telecom Europe A2LA, NIST EMC, RF, Telecom , Safety Accreditations for Product Certifications Country Accreditation Body Scope USA FCC TCB, NIST EMC , RF , Telecom Canada IC FCB , NIST EMC , RF , Telecom Singapore iDA, NIST EMC , RF , Telecom Title: EMC Test Report of Power Supply Module To FCC Part 15B : 2009 Serial# SL10050401-IDS-001_FCC(IBIS-SU-STD,IBIS-SU-ADV) Rev1.0 Issue Date June 13th 2010 Page 4 of 44 www.siemic.com This page has been left blank intentionally. Title: EMC Test Report of Power Supply Module To FCC Part 15B : 2009 Serial# SL10050401-IDS-001_FCC(IBIS-SU-STD,IBIS-SU-ADV) Rev1.0 Issue Date June 13th 2010 Page 5 of 44 www.siemic.com CONTENTS 1 EXECUTIVE SUMMARY & EUT INFORMATION..................................................................................................................... 7 2 TECHNICAL DETAILS........................................................................................................................................................... 8 3 MODIFICATION..................................................................................................................................................................... 9 4 TEST SUMMARY................................................................................................................................................................. 10 5 MEASUREMENTS, EXAMINATION AND DERIVED RESULTS.............................................................................................. 11 ANNEX A. TEST INSTRUMENT & METHOD.................................................................................................................................. 16 ANNEX B. TEST SETUP PHOTOGRAPHS................................................................................................................................... 19 ANNEX C. TEST SETUP AND SUPPORTING EQUIPMENT............................................................................................................ 22 ANNEX D USER MANUAL, BLOCK & CIRCUIT DIAGRAM............................................................................................................ 27 ANNEX E. SIEMIC ACCREDITATION CERTIFICATES.................................................................................................................... 28 Title: EMC Test Report of Power Supply Module To FCC Part 15B : 2009 Serial# SL10050401-IDS-001_FCC(IBIS-SU-STD,IBIS-SU-ADV) Rev1.0 Issue Date June 13th 2010 Page 6 of 44 www.siemic.com This page has been left blank intentionally. Title: EMC Test Report of Power Supply Module To FCC Part 15B : 2009 Serial# SL10050401-IDS-001_FCC(IBIS-SU-STD,IBIS-SU-ADV) Rev1.0 Issue Date June 13th 2010 Page 7 of 44 www.siemic.com 1 Executive Summary & EUT information The purpose of this test program was to demonstrate compliance of the Ingegneria dei Sistemi S.P.A Power Supply Module, and model: IBIS-SU-STD, IBIS-SU-ADV against the current Stipulated Standards. The IBIS-SU- STD, IBIS-SU-ADV have demonstrated compliance with the FCC Part 15B : 2009, . EUT Information EUT Description : The IBIS Supply Unit is a part of the IBIS-L system. The IBIS-L system is designed to remotely measure slow displacements with an accuracy as great as a tenth of a millimetre. The IBIS-L system is particularly suitable for terrain and structural monitoring applications, with the aim of detecting quasi-static displacements over long time periods. The power supply module supplies electric power to the system, in detail its function is to: Receive power from the mains electricity or from a generator …

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Emission (30MHz to 1GHz) Radiated Emission Test Setup - Front View Radiated Emission Test Setup – Rear View Conducted Emission Conducted Emission Test Setup – Front View Conducted Emission Test Setup – Rear View

Contact Information

Applicant

Alessandro Simi(R & D Director)
[email protected]00390508934245Fax: 00390508934258

Test Firm

Bureau Veritas Consumer Products Services, Inc.Sarb Shelopal
[email protected]+1 925 963 4420

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from IDS GeoRadar s.r.l.

High Definition Ground Based SAR - FCC ID UFW-HYDRA2 - IDS GeoRadar s.r.l.
UFW-HYDRA2

High Definition Ground Based SAR

Aug 11, 2026

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Ku-band radar sensor - FCC ID UFW-IBIS-KU-ETH3 - IDS GeoRadar s.r.l.
UFW-IBIS-KU-ETH3

Ku-band radar sensor

Aug 05, 2024

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Cable locator transmitter - FCC ID UFW-DA300 - IDS GeoRadar s.r.l.
UFW-DA300

Cable locator transmitter

Jul 30, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Chaser XR GPR CHASERXR - FCC ID UFW-CHASERXR - IDS GeoRadar s.r.l.
UFW-CHASERXR

Chaser XR GPR CHASERXR

Sep 25, 2023

Equipment Class

UWB - Ultra Wideband Transmitter
UFW-AM201

GPR AM201

Jul 31, 2022

Equipment Class

UWB - Ultra Wideband Transmitter